PCam
11 papers · 25 extracted observations · image classification · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | LoTeNet SOTA frontier | 0.943 | 2020-01-01 | layers=3 · kernel-size=2 · bond-dimension=5 · Independent test set; LoTeNet evaluated with L=3, kernel size k=2, and bond dimension… | Tensor Networks for Medical Image ClassificationSource quote{LoTeNet (ours)} │ 0.8 │ 0.943 |
| 2 | Student Head I | 0.9216 | 2022-01-01 | model=Student Head I · Classification performance on the PCam test set. | Toward Scalable and Unified Example-Based Explanation and Outlier DetectionSource quoteStudent Head I \ │ 83.3 │ 0.9216 |
| 3 | BiomedCLIP structured weak labels, DenseNet-121 | 0.844 | 2026-01-01 | seeds=3 · backbone=DenseNet-121 · gold_count=10 · weak_labels=50K · Gold count 10; nw=50K; matched-rate structured-versus-random comparison; 3-seed mean. | From Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging BenchmarksSource quote.844 |
Metricauc (8)accuracy (8)negative log likelihood nll (2)gpu memory utilization (2)percentage of images with the same prediction re (2)f1 (1)
Splittest (12)
Regimelinear-probe (1)
Showing 25 of 25 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | BiomedCLIP structured weak labels, DenseNet-121 proposed | AUC | .844 | seeds=3 · backbone=DenseNet-121 · gold_count=10 · weak_labels=50K | From Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging BenchmarksSource quoteL222: .844 |
| 2026 | Matched-rate random noise, DenseNet-121 baseline | AUC | .946 | seeds=3 · backbone=DenseNet-121 · gold_count=10 · noise_type=matched-rate random · weak_labels=50K | From Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging BenchmarksSource quoteL223: .946 |
| 2025 | CLIP-IT (ViT-B/8) proposed | accuracy gain | +4.4% | backbone=CLIP | CLIP-IT: CLIP-based Pairing for Histology Images ClassificationSource quoteL95: \autoref{tab:perf} presents the average classification accuracy and standard deviation (std) across several state-of-the-art vision backbones, trained either as a unimodal baseline, or with the proposed \texttt{CLIP-IT}\xspace method. Evaluation is performed on three histopathology datasets: PCAM, BACH, and CRC. \texttt{CLIP-IT}\xspace improves the unimodal baselines in most settings and maintains performance in a few other settings. For example, on PCAM, \texttt{CLIP-IT}\xspace yields gains as high as +4.4% for ViT-B/8. On BACH, performance improvements are most notable for models like UNI and ViT-S/16, with gains up to +2.9%. The variance in BACH stems from the base vision model's instability on this small dataset. Our method consistently improves or matches performance despite this variance, showing robustness to backbone fluctuations. Although CRC has strong unimodal baselines (e.g., ViT-B/16 with 95.9%), \texttt{CLIP-IT}\xspace still offers modest improvements or preserves parity in most cases. No unimodal backbone experiences significant performance degradation when enhanced with \texttt{CLIP-IT}\xspace. These results have a combined p-value of 2.65×10 (-5), indicating a highly significant overall effect. |
| 2025 | FTCFormer proposed | classification accuracy | 87.49 | resolution=64×64 | FTCFormer: Fuzzy Token Clustering Transformer for Image ClassificationSource quoteL229: FTCFormer │ 87.49 |
| 2025 | TCFormer baseline | classification accuracy | 86.47 | resolution=64×64 | FTCFormer: Fuzzy Token Clustering Transformer for Image ClassificationSource quoteL228: TCFormer \cite{tcformer} │ 86.47 |
| 2024 | GUD real-space column-wise schedule (b=0.3) proposed | negative log-likelihood (NLL) | 3.90 bits/dim | schedule=real-space column-wise, b=0.3 · resolution=32×32 | GUD: Generation with Unified DiffusionSource quoteL352: We trained separate score networks at b=0.3 and b=0.5 on the PCAM dataset \citep{Veeling2018-qh}, downscaled to 32 × 32 pixels, obtaining negative log-likelihoods of 3.90 and 3.94\,bits/dim, respectively. |
| 2024 | GUD real-space column-wise schedule (b=0.5) proposed | negative log-likelihood (NLL) | 3.94 bits/dim | schedule=real-space column-wise, b=0.5 · resolution=32×32 | GUD: Generation with Unified DiffusionSource quoteL352: We trained separate score networks at b=0.3 and b=0.5 on the PCAM dataset \citep{Veeling2018-qh}, downscaled to 32 × 32 pixels, obtaining negative log-likelihoods of 3.90 and 3.94\,bits/dim, respectively. |
| 2024 | CAMP-Phikon proposed | F1 | 0.985 | split: test · backbone=Phikon · evaluation-level=patch | CAMP: Continuous and Adaptive Learning Model in PathologySource quoteL331: Overall, CAMP was able to conduct the 11 different classification tasks in an accurate and consistent manner (Fig. \ref{fig_camp_vs_full_ft}), achieving 0.756\sim0.861 F1, 0.809 F1, 0.488\sim0.905 F1, 0.478\sim0.998 F1, 0.961 F1, 0.915 F1, 0.895 F1, 0.782 F1, 0.985 F1, 0.486 F1, and 0.838 F1 for colorectal cancer grading (Colon-1 and Colon-2), gastric cancer grading, prostate cancer grading (UHU, UBC, AGGC, and PANDA), colorectal tissue sub-typing (K19, K16, and HunCRC-P), liver cancer grading, kidney cancer grading, bladder cancer grading, breast cancer sub-typing, breast metastasis detection, colorectal polyp sub-typing and lung cancer detection, respectively. |
| 2024 | CWT-Net proposed | Acc | 80.85 | backbone=ResNet-50 · sr-scale=2× | CWT-Net: Super-resolution of Histopathology Images Using a Cross-scale Wavelet-based TransformerSource quoteL344: CWT-Net │ 88.12 │ 80.85 |
| 2024 | SWD-Net baseline | Acc | 80.48 | backbone=ResNet-50 · sr-scale=2× | CWT-Net: Super-resolution of Histopathology Images Using a Cross-scale Wavelet-based TransformerSource quoteL343: SWD-Net\cite{bib27} │ 86.47 │ 80.48 |
| 2024 | DenseNet121 baseline | Recall drop | 0.40 | context-manipulation=black border | Does context matter in digital pathology?Source quoteL106: It is observed that the metric that is the most affected by limiting the amount of contextual information available at the prediction time is recall. This metric is especially important in healthcare where false negatives are of the greatest concern. The biggest drop in recall (0.84) occurs in the case of MoCo\xspace model which starts to predict mostly one class - normal. At the~same time, in the case of this model, the precision curve slightly increases with the decrease of context size (up to 0.016 when context\_size=0) even though the reference value was already very high (0.9617). The two models that experience the~smallest drop of recall are Swin\xspace (0.41) and \DenseNet121 (0.40). |
| 2024 | DenseNet121 baseline | Precision drop | 0.14 | context-manipulation=black border | Does context matter in digital pathology?Source quoteL108: Note that precision seems to be the least impacted metric by the limitation of contextual information. The~most considerable decrease is observed in the~case of \DenseNet121 (0.14) and MAE\xspace (0.11), however, in the~first case, the~significant drop is observed even when the~amount of context is only slightly limited. |
| 2024 | Swin baseline | Percentage of images with the same prediction regardless of context size | 72.41% | Evaluated across different context sizes. | Does context matter in digital pathology?Source quoteL123: 54.66 │ 52.39 │ 72.41 │ 69.06 │ 60.76 │ 58.20 |
| 2024 | DenseNet121 baseline | Percentage of images with the same prediction regardless of context size | 52.39% | Evaluated across different context sizes. | Does context matter in digital pathology?Source quoteL123: 54.66 │ 52.39 │ 72.41 │ 69.06 │ 60.76 │ 58.20 |
| 2023 | Linear probing baseline | test accuracy | 83.5% | split: test · linear-probe · params=2B · backbone=ViT-B/32 · pretraining=OpenCLIP LAION-2B | On the Benefits of Public Representations for Private Transfer Learning under Distribution ShiftSource quoteL260: Linear probing │ 83.5 │ 42.1 │ 91.7 |
| 2020 | Student Head I proposed | AUC | 0.9216 | split: test · model=Student Head I | Toward Scalable and Unified Example-Based Explanation and Outlier DetectionSource quoteL369: Student Head I \ │ 83.3 │ 0.9216 |
| 2020 | LoTeNet proposed | AUC | 0.943 | split: test · layers=3 · kernel-size=2 · bond-dimension=5 | Tensor Networks for Medical Image ClassificationSource quoteL141: {LoTeNet (ours)} │ 0.8 │ 0.943 |
| 2020 | LoTeNet proposed | GPU memory utilization | 0.8 GB | split: test · layers=3 · kernel-size=2 · bond-dimension=5 | Tensor Networks for Medical Image ClassificationSource quoteL141: {LoTeNet (ours)} │ 0.8 │ 0.943 |
| 2020 | Teacher (baseline) baseline | AUC | 0.9142 | split: test · model=Teacher | Toward Scalable and Unified Example-Based Explanation and Outlier DetectionSource quoteL368: \ Teacher (baseline) \ │ 80.5 │ 0.9142 \hhline{|=|=|=|} |
| 2020 | Rotation Eq-CNN baseline | AUC | 0.963 | split: test | Tensor Networks for Medical Image ClassificationSource quoteL139: Rotation Eq-CNN │ 11.0 │ 0.963 |
| 2020 | DenseNet baseline | AUC | 0.962 | split: test · layers=4 · growth-rate=12 | Tensor Networks for Medical Image ClassificationSource quoteL140: {DenseNet} │ 10.5 │ 0.962 |
| 2020 | Tensor Net-X (β=10) baseline | AUC | 0.908 | split: test · architecture=single-layer MPS · bond-dimension=10 | Tensor Networks for Medical Image ClassificationSource quoteL142: {Tensor Net-X (\beta=10)} │ 5.2 │ 0.908 |
| 2020 | DenseNet baseline | GPU memory utilization | 10.5 GB | split: test · layers=4 · growth-rate=12 | Tensor Networks for Medical Image ClassificationSource quoteL140: {DenseNet} │ 10.5 │ 0.962 |
| 2019 | CELNet proposed | Acc | 91.87 | split: test | Evidence Localization for Pathology Images Using Weakly Supervised LearningSource quoteL100: CELNet │ 91.87 │ 97.72 │ 297K |
| 2019 | P4M-DenseNet baseline | Acc | 89.80 | split: test | Evidence Localization for Pathology Images Using Weakly Supervised LearningSource quoteL99: P4M-DenseNet │ 89.80 │ 96.30 │ 119K |