PCam

11 papers · 25 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.80.90.91.0202020232026LoTeNet: 0.943 (2020)Student Head I: 0.9216 (2022)BiomedCLIP structured weak labels, DenseNet-121: 0.844 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 11 of 11 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026BiomedCLIP structured weak labels, DenseNet-121 proposedAUC.844seeds=3 · backbone=DenseNet-121 · gold_count=10 · weak_labels=50KFrom Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging Benchmarks
Source quote
L222: .844
2025CLIP-IT (ViT-B/8) proposedaccuracy gain+4.4%backbone=CLIPCLIP-IT: CLIP-based Pairing for Histology Images Classification
Source quote
L95: \autoref{tab:perf} presents the average classification accuracy and standard deviation (std) across several state-of-the-art vision backbones, trained either as a unimodal baseline, or with the proposed \texttt{CLIP-IT}\xspace method. Evaluation is performed on three histopathology datasets: PCAM, BACH, and CRC. \texttt{CLIP-IT}\xspace improves the unimodal baselines in most settings and maintains performance in a few other settings. For example, on PCAM, \texttt{CLIP-IT}\xspace yields gains as high as +4.4% for ViT-B/8. On BACH, performance improvements are most notable for models like UNI and ViT-S/16, with gains up to +2.9%. The variance in BACH stems from the base vision model's instability on this small dataset. Our method consistently improves or matches performance despite this variance, showing robustness to backbone fluctuations. Although CRC has strong unimodal baselines (e.g., ViT-B/16 with 95.9%), \texttt{CLIP-IT}\xspace still offers modest improvements or preserves parity in most cases. No unimodal backbone experiences significant performance degradation when enhanced with \texttt{CLIP-IT}\xspace. These results have a combined p-value of 2.65×10 (-5), indicating a highly significant overall effect.
2025FTCFormer proposedclassification accuracy87.49resolution=64×64FTCFormer: Fuzzy Token Clustering Transformer for Image Classification
Source quote
L229: FTCFormer │ 87.49
2024GUD real-space column-wise schedule (b=0.3) proposednegative log-likelihood (NLL)3.90 bits/dimschedule=real-space column-wise, b=0.3 · resolution=32×32GUD: Generation with Unified Diffusion
Source quote
L352: We trained separate score networks at b=0.3 and b=0.5 on the PCAM dataset \citep{Veeling2018-qh}, downscaled to 32 × 32 pixels, obtaining negative log-likelihoods of 3.90 and 3.94\,bits/dim, respectively.
2024GUD real-space column-wise schedule (b=0.5) proposednegative log-likelihood (NLL)3.94 bits/dimschedule=real-space column-wise, b=0.5 · resolution=32×32GUD: Generation with Unified Diffusion
Source quote
L352: We trained separate score networks at b=0.3 and b=0.5 on the PCAM dataset \citep{Veeling2018-qh}, downscaled to 32 × 32 pixels, obtaining negative log-likelihoods of 3.90 and 3.94\,bits/dim, respectively.
2024CAMP-Phikon proposedF10.985split: test · backbone=Phikon · evaluation-level=patchCAMP: Continuous and Adaptive Learning Model in Pathology
Source quote
L331: Overall, CAMP was able to conduct the 11 different classification tasks in an accurate and consistent manner (Fig. \ref{fig_camp_vs_full_ft}), achieving 0.756\sim0.861 F1, 0.809 F1, 0.488\sim0.905 F1, 0.478\sim0.998 F1, 0.961 F1, 0.915 F1, 0.895 F1, 0.782 F1, 0.985 F1, 0.486 F1, and 0.838 F1 for colorectal cancer grading (Colon-1 and Colon-2), gastric cancer grading, prostate cancer grading (UHU, UBC, AGGC, and PANDA), colorectal tissue sub-typing (K19, K16, and HunCRC-P), liver cancer grading, kidney cancer grading, bladder cancer grading, breast cancer sub-typing, breast metastasis detection, colorectal polyp sub-typing and lung cancer detection, respectively.
2024CWT-Net proposedAcc80.85backbone=ResNet-50 · sr-scale=2×CWT-Net: Super-resolution of Histopathology Images Using a Cross-scale Wavelet-based Transformer
Source quote
L344: CWT-Net │ 88.12 │ 80.85
2020Student Head I proposedAUC0.9216split: test · model=Student Head IToward Scalable and Unified Example-Based Explanation and Outlier Detection
Source quote
L369: Student Head I \ │ 83.3 │ 0.9216
2020LoTeNet proposedAUC0.943split: test · layers=3 · kernel-size=2 · bond-dimension=5Tensor Networks for Medical Image Classification
Source quote
L141: {LoTeNet (ours)} │ 0.8 │ 0.943
2020LoTeNet proposedGPU memory utilization0.8 GBsplit: test · layers=3 · kernel-size=2 · bond-dimension=5Tensor Networks for Medical Image Classification
Source quote
L141: {LoTeNet (ours)} │ 0.8 │ 0.943
2019CELNet proposedAcc91.87split: testEvidence Localization for Pathology Images Using Weakly Supervised Learning
Source quote
L100: CELNet │ 91.87 │ 97.72 │ 297K