PCam
11 papers · 25 extracted observations · image classification · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | LoTeNet SOTA frontier | 0.943 | 2020-01-01 | layers=3 · kernel-size=2 · bond-dimension=5 · Independent test set; LoTeNet evaluated with L=3, kernel size k=2, and bond dimension… | Tensor Networks for Medical Image ClassificationSource quote{LoTeNet (ours)} │ 0.8 │ 0.943 |
| 2 | Student Head I | 0.9216 | 2022-01-01 | model=Student Head I · Classification performance on the PCam test set. | Toward Scalable and Unified Example-Based Explanation and Outlier DetectionSource quoteStudent Head I \ │ 83.3 │ 0.9216 |
| 3 | BiomedCLIP structured weak labels, DenseNet-121 | 0.844 | 2026-01-01 | seeds=3 · backbone=DenseNet-121 · gold_count=10 · weak_labels=50K · Gold count 10; nw=50K; matched-rate structured-versus-random comparison; 3-seed mean. | From Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging BenchmarksSource quote.844 |
Metricauc (8)accuracy (8)negative log likelihood nll (2)gpu memory utilization (2)percentage of images with the same prediction re (2)f1 (1)
Splittest (12)
Regimelinear-probe (1)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | CLIP-IT (ViT-B/8) proposed | accuracy gain | +4.4% | backbone=CLIP | CLIP-IT: CLIP-based Pairing for Histology Images ClassificationSource quoteL95: \autoref{tab:perf} presents the average classification accuracy and standard deviation (std) across several state-of-the-art vision backbones, trained either as a unimodal baseline, or with the proposed \texttt{CLIP-IT}\xspace method. Evaluation is performed on three histopathology datasets: PCAM, BACH, and CRC. \texttt{CLIP-IT}\xspace improves the unimodal baselines in most settings and maintains performance in a few other settings. For example, on PCAM, \texttt{CLIP-IT}\xspace yields gains as high as +4.4% for ViT-B/8. On BACH, performance improvements are most notable for models like UNI and ViT-S/16, with gains up to +2.9%. The variance in BACH stems from the base vision model's instability on this small dataset. Our method consistently improves or matches performance despite this variance, showing robustness to backbone fluctuations. Although CRC has strong unimodal baselines (e.g., ViT-B/16 with 95.9%), \texttt{CLIP-IT}\xspace still offers modest improvements or preserves parity in most cases. No unimodal backbone experiences significant performance degradation when enhanced with \texttt{CLIP-IT}\xspace. These results have a combined p-value of 2.65×10 (-5), indicating a highly significant overall effect. |
| 2025 | FTCFormer proposed | classification accuracy | 87.49 | resolution=64×64 | FTCFormer: Fuzzy Token Clustering Transformer for Image ClassificationSource quoteL229: FTCFormer │ 87.49 |
| 2024 | CWT-Net proposed | Acc | 80.85 | backbone=ResNet-50 · sr-scale=2× | CWT-Net: Super-resolution of Histopathology Images Using a Cross-scale Wavelet-based TransformerSource quoteL344: CWT-Net │ 88.12 │ 80.85 |
| 2019 | CELNet proposed | Acc | 91.87 | split: test | Evidence Localization for Pathology Images Using Weakly Supervised LearningSource quoteL100: CELNet │ 91.87 │ 97.72 │ 297K |