LIDC-IDRI

51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.50.70.81.0202120232025SIB (single Inpainting Block): 0.941 (2021)2D LS-AAE: 0.944 (2021)MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet): 0.924 (2022)OW-CNFs: 0.819 (2024)DVG-Diffusion (without new-view input): 0.532 (2025)DVG-Diffusion (90° synthesized view): 0.541 (2025)VPGE-Diffusion: 0.667 (2025)DVG-Diffusion: 0.679 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 161 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Volumetric Directional Diffusion (VDD) proposed95% Hausdorff Distance (HD95)1.36split_ratio=8:1:1 · dimensionality=3DVolumetric Directional Diffusion: Anchoring Uncertainty Quantification in Anatomical Consensus for Ambiguous Medical Image Segmentation
Source quote
L123: As shown in Table~\ref{tab:comprehensive_results}, while deterministic baselines (e.g., nnU-Net 3D) achieve high structural precision (e.g., 0.7671 Dice on LIDC-IDRI ), they fail to capture inter-reader variability. Conversely, slice-wise 2D diffusion models exhibit catastrophic topological degradation, with HD95 scores soaring to 18.05 on LIDC-IDRI and 21.34 on KiTS21. By anchoring the generative trajectory to a 3D structural prior, VDD successfully resolves this trade-off, restoring consistency and slashing HD95 to 1.36 on LIDC-IDRI. Remarkably, VDD remains highly competitive in Dice accuracy and even outperforms nnU-Net 3D on ISBI 2015 (0.6989 vs. 0.6914), proving that residual exploration can refine macroscopic consensus.
2026Harmonizer Network (Harmonizer, ours) proposedDSC84.27split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L416: 89.37 │ 1.44 │ 87.92 │ 2.88 │ 84.27 │ 6.53
2026VIVID-Med proposedAUC0.8413modality=CT slices · pretraining-modality=chest X-rayVIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTs
Source quote
L4: Vision-language pretraining has driven significant progress in medical image analysis. However, current methods typically supervise visual encoders using one-hot labels or free-form text, neither of which effectively captures the complex semantic relationships among clinical findings. In this study, we introduce VIVID-Med, a novel framework that leverages a frozen large language model (LLM) as a structured semantic teacher to pretrain medical vision transformers (ViTs). VIVID-Med translates clinical findings into verifiable JSON field-state pairs via a Unified Medical Schema (UMS), utilizing answerability-aware masking to focus optimization. It then employs Structured Prediction Decomposition (SPD) to partition cross-attention into orthogonality-regularized query groups, extracting complementary visual aspects. Crucially, the LLM is discarded post-training, yielding a lightweight, deployable ViT-only backbone. We evaluated VIVID-Med across multiple settings: on CheXpert linear probing, it achieves a macro-AUC of 0.8588, outperforming BiomedCLIP by {+}6.65 points while using 500× less data. It also demonstrates robust zero-shot cross-domain transfer to NIH ChestX-ray14 (0.7225 macro-AUC) and strong cross-modality generalization to CT, achieving 0.8413 AUC on LIDC-IDRI lung nodule classification and 0.9969 macro-AUC on OrganAMNIST 11-organ classification. VIVID-Med offers a highly efficient, scalable alternative to deploying resource-heavy vision-language models in clinical settings.
2026D-PersonaDSC71.11split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L411: 85.74 │ 3.43 │ 81.80 │ 7.37 │ 71.11 │ 18.06
2026Harmonizer NetworkDSC85.30split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L616: 85.30 │ 5.48
2026D-PersonaDSC83.02split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L613: 83.02 │ 6.15
2026PRDiT-128^{\text{scratch}}MMD0.1853128^3; trained directly at 128^3 (Scratch).Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume Generation
Source quote
L456: PRDiT-128^{\text{\;scratch}} │ 2.04 │ 0.1853 │ 80 GPUh
2026PRDiT-64 ↑ (128)FID2.89128^3; progressive strategy reuses a pretrained 64^3 model and extends it to 128^3; FID…Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume Generation
Source quote
L457: PRDiT-64\,\uparrow (128) │ 2.89 │ 0.1893 │ 12 GPUh
2026PRDiT-64 ↑ (128)MMD0.1893128^3; progressive strategy reuses a pretrained 64^3 model and extends it to 128^3.Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume Generation
Source quote
L457: PRDiT-64\,\uparrow (128) │ 2.89 │ 0.1893 │ 12 GPUh
2026Slice-wise 2D diffusion models baseline95% Hausdorff Distance (HD95)18.05split_ratio=8:1:1 · dimensionality=2D · inference_style=slice-wiseVolumetric Directional Diffusion: Anchoring Uncertainty Quantification in Anatomical Consensus for Ambiguous Medical Image Segmentation
Source quote
L123: As shown in Table~\ref{tab:comprehensive_results}, while deterministic baselines (e.g., nnU-Net 3D) achieve high structural precision (e.g., 0.7671 Dice on LIDC-IDRI ), they fail to capture inter-reader variability. Conversely, slice-wise 2D diffusion models exhibit catastrophic topological degradation, with HD95 scores soaring to 18.05 on LIDC-IDRI and 21.34 on KiTS21. By anchoring the generative trajectory to a 3D structural prior, VDD successfully resolves this trade-off, restoring consistency and slashing HD95 to 1.36 on LIDC-IDRI. Remarkably, VDD remains highly competitive in Dice accuracy and even outperforms nnU-Net 3D on ISBI 2015 (0.6989 vs. 0.6914), proving that residual exploration can refine macroscopic consensus.
2025TV(Ens, CAE) proposedAAC27.7 ×10−4Results averaged over four experimental setups. CAE is trained on expert soft labels an…Improving Uncertainty Estimation with Confidence-Aware Training Data
Source quote
L404: 27.7
2025ProSona (table label: Pro Sona (ours)) proposedGeneralized Energy Distance (GED) ↓0.120LIDC–IDRI results; GED as reported in the comparison table.ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image Segmentation
Source quote
L150: Pro\,Sona (ours) │ 0.120 │ 91.56 │ 92.29 │ 90.26 │ 90.26
2025ProSona (table label: Pro Sona (ours)) proposedMean Dice ↑90.26LIDC–IDRI results; Mean Dice across annotators or institutions.ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image Segmentation
Source quote
L150: Pro\,Sona (ours) │ 0.120 │ 91.56 │ 92.29 │ 90.26 │ 90.26
2025DiffOSeg proposedGED_10 (Generalized Energy Distance)0.0915split: val · samples=10 · evaluation=4-fold-cross-validationDiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion Model
Source quote
L119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358).
2025DiffOSeg proposedGED_30 (Generalized Energy Distance)0.0773split: val · samples=30 · evaluation=4-fold-cross-validationDiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion Model
Source quote
L119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358).
2025DiffOSeg proposedGED_50 (Generalized Energy Distance)0.0745split: val · samples=50 · evaluation=4-fold-cross-validationDiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion Model
Source quote
L119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358).
2025LungNoduleAgent proposedLungDLC-score83.5Public benchmark; localized CT report generation. LungDLC evaluates whether description…LungNoduleAgent: A Collaborative Multi-Agent System for Precision Diagnosis of Lung Nodules
Source quote
L259: As demonstrated in \textbf{Table \ref{tab:1}}, LungNoduleAgent exhibits state-of-the-art performance across all three benchmark datasets, with significant improvements on the Qwen and LLaVA base models. Compared with the highest score among other methods, on the PrivateA dataset, it achieves a LungDLC-score of 81.9, reflecting an increase of 6.3. For the PrivateB dataset, the model attains a score of 80.3, marking an improvement of 4.1. This performance advantage is also evident on the public LIDC-IDRI benchmark, where the model scores 83.5, representing 8.3 increasing.
2025CLS with Med3D proposedECR0.8137alpha=0.2 · backbone=Med3DConformal Lesion Segmentation for 3D Medical Images
Source quote
L282: After applying CLS calibration at a risk level of \alpha = 0.2, ECR improves substantially and consistently, achieving gains of over +0.45 absolute improvement on average. For example, the ECR of Med3D on LIDC-IDRI increases from 0.4783 to 0.8137, while Swin-UNETR on KiTS21 jumps from 0.4081 to 0.8289, indicating a near doubling in lesion coverage. These results confirm that CLS not only enforces failure rate constraints but also enhances practical segmentation quality.
2025CPYOLO proposedFPS137.4 f/sTable 2 LIDC-IDRI benchmark; no evaluation split is specified in the cited results.CPLOYO: A pulmonary nodule detection model with multi-scale feature fusion and nonlinear feature learning
Source quote
L343: 137.4
2025CLS-DM proposedPSNR27.36 dB2-view · views=frontal-and-lateral · hu-range=0-4095 · precision=12-bitLatent Space Consistency for Sparse-View CT Reconstruction
Source quote
L226: CLS-DM (ours) │ 23.02 │ 0.5931 │ 24.96 │ 0.6585 │ 27.36 │ 0.7058
2025CLS-DM proposedSSIM0.70582-view · views=frontal-and-lateral · hu-range=0-4095 · precision=12-bitLatent Space Consistency for Sparse-View CT Reconstruction
Source quote
L226: CLS-DM (ours) │ 23.02 │ 0.5931 │ 24.96 │ 0.6585 │ 27.36 │ 0.7058
2025ProSeg proposedGED0.1152Reported for ProSeg on LIDC-IDRI; the results prose does not specify a prior-sampling v…Probabilistic Modeling of Multi-rater Medical Image Segmentation for Diversity and Personalization
Source quote
L265: Table. ~\ref{tab_lidc} reports the performance of the different methods in terms of diversity, personalization, and personalized segmentation. Compared to generative methods, our ProSeg consistently achieves the best diversity performance with the lowest GED (0.1152) and the highest soft Dice score D-soft (91.53%), which demonstrates its ability to generate a wide range of meaningful segmentation variations that can significantly improve diversity while maintaining high-quality segmentation.
2025ProSeg proposedSoft Dice Score (D-soft)91.53%thresholds=0.1, 0.3, 0.5, 0.7, 0.9Probabilistic Modeling of Multi-rater Medical Image Segmentation for Diversity and Personalization
Source quote
L265: Table. ~\ref{tab_lidc} reports the performance of the different methods in terms of diversity, personalization, and personalized segmentation. Compared to generative methods, our ProSeg consistently achieves the best diversity performance with the lowest GED (0.1152) and the highest soft Dice score D-soft (91.53%), which demonstrates its ability to generate a wide range of meaningful segmentation variations that can significantly improve diversity while maintaining high-quality segmentation.
2025ProSeg proposedD-max91.03%Reported for ProSeg on LIDC-IDRI; multi-rater personalization metric.Probabilistic Modeling of Multi-rater Medical Image Segmentation for Diversity and Personalization
Source quote
L266: In terms of personalization performance, the D-max of ProSeg reaches 91.03%, as it is able to effectively capture expert-specific segmentation patterns in the latent space.
2025ProSeg proposedD-mean90.25%Reported as the average Dice similarity for ProSeg on LIDC-IDRI.Probabilistic Modeling of Multi-rater Medical Image Segmentation for Diversity and Personalization
Source quote
L267: In terms of personalized segmentation accuracy, ProSeg achieves state-of-the-art (SOTA) performance with the highest average dice similarity (D-mean = 90.25%) and consistently strong performance across annotators (D\textsubscript{A1} = 89.49%, D\textsubscript{A2} = 90.27%, D\textsubscript{A3} = 91.01%, D\textsubscript{A4} = 90.23%). Besides, by sampling the prior distribution of q(\tau), our ProSeg (prior) achieves a better GED score, since more expert preferences are sampled.
2025DVG-Diffusion (90° synthesized view) proposedPSNR22.54split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L273: PSNR \uparrow │ 22.29 │ 22.46 │ 22.47 │ 22.43 │ 22.48 │ 22.54 │ 22.47
2025DVG-Diffusion (90° synthesized view) proposedSSIM0.541split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537
2025TV(Ens, −) ablationAAC29.4 ×10−4Epistemic-only ensemble result, averaged over four experimental setups; scans were divi…Improving Uncertainty Estimation with Confidence-Aware Training Data
Source quote
L396: 29.4
2025Baseline (single-scale mask autoencoder with next-token prediction) ablationGED0.275Component ablation; GED subcolumn labeled 16.Autoregressive Medical Image Segmentation via Next-Scale Mask Prediction
Source quote
L146: Baseline │ 0.275 │ 0.310 │ 0.383 │ 0.814 │ 0.557
2025Baseline (single-scale mask autoencoder with next-token prediction) ablationHM-IoU0.557Component ablation; HM-IoU subcolumn labeled 16.Autoregressive Medical Image Segmentation via Next-Scale Mask Prediction
Source quote
L146: Baseline │ 0.275 │ 0.310 │ 0.383 │ 0.814 │ 0.557
2025AR-Seg (+ Next-scale autoregressive) ablationGED0.239Component ablation; next-scale autoregressive row; GED subcolumn labeled 16.Autoregressive Medical Image Segmentation via Next-Scale Mask Prediction
Source quote
L147: \quad+ Next-scale autoregressive │ 0.239 │ 0.277 │ 0.348 │ 0.745 │ 0.595
2025AR-Seg (+ Next-scale autoregressive) ablationHM-IoU0.595Component ablation; next-scale autoregressive row; HM-IoU subcolumn labeled 16.Autoregressive Medical Image Segmentation via Next-Scale Mask Prediction
Source quote
L147: \quad+ Next-scale autoregressive │ 0.239 │ 0.277 │ 0.348 │ 0.745 │ 0.595
2025AR-Seg (+ SVD-based adapter) ablationGED0.232Component ablation; next-scale autoregressive framework with SVD-based adapter; GED sub…Autoregressive Medical Image Segmentation via Next-Scale Mask Prediction
Source quote
L148: \quad\quad + SVD-based adapter │ 0.232 │ 0.267 │ 0.332 │ 0.736 │ 0.616
2025AR-Seg (+ SVD-based adapter) ablationHM-IoU0.616Component ablation; next-scale autoregressive framework with SVD-based adapter; HM-IoU …Autoregressive Medical Image Segmentation via Next-Scale Mask Prediction
Source quote
L148: \quad\quad + SVD-based adapter │ 0.232 │ 0.267 │ 0.332 │ 0.736 │ 0.616
2025w/o CLIP ablationPSNR25.37 dB2-view · views=frontal-and-lateral · variant=without-contrastive-learning · backbone=CLIP · hu-range=0-4095 · precision=12-bitLatent Space Consistency for Sparse-View CT Reconstruction
Source quote
L221: w/o CLIP │ 22.42 │ 0.5919 │ 25.17 │ 0.6591 │ 25.37 │ 0.6701
2025w/o CLIP ablationSSIM0.67012-view · views=frontal-and-lateral · variant=without-contrastive-learning · backbone=CLIP · hu-range=0-4095 · precision=12-bitLatent Space Consistency for Sparse-View CT Reconstruction
Source quote
L221: w/o CLIP │ 22.42 │ 0.5919 │ 25.17 │ 0.6591 │ 25.37 │ 0.6701
2025w/o CLIP, AR (LDM) ablationPSNR24.94 dB2-view · views=frontal-and-lateral · variant=without-contrastive-learning-and-autoregressive-constraint · backbone=LDM · hu-range=0-4095 · precision=12-bitLatent Space Consistency for Sparse-View CT Reconstruction
Source quote
L225: w/o CLIP,AR(LDM) │ 20.65 │ 0.5864 │ 24.73 │ 0.6473 │ 24.94 │ 0.6515
2025w/o CLIP, AR (LDM) ablationSSIM0.65152-view · views=frontal-and-lateral · variant=without-contrastive-learning-and-autoregressive-constraint · backbone=LDM · hu-range=0-4095 · precision=12-bitLatent Space Consistency for Sparse-View CT Reconstruction
Source quote
L225: w/o CLIP,AR(LDM) │ 20.65 │ 0.5864 │ 24.73 │ 0.6473 │ 24.94 │ 0.6515
2025DVG-Diffusion ablationSSIM0.679split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L228: DVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35
2025VPGE-Diffusion ablationSSIM0.667split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L227: \checkmark │ 26.47 │ 0.667 │ 28.11
2025DVG-Diffusion (without new-view input) ablationPSNR22.29split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L273: PSNR \uparrow │ 22.29 │ 22.46 │ 22.47 │ 22.43 │ 22.48 │ 22.54 │ 22.47
2025DVG-Diffusion (without new-view input) ablationSSIM0.532split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537
2025SSB++GED0.208split: testAmbiguous Medical Image Segmentation Using Diffusion Schrödinger Bridge
Source quote
L160: SSB++ (Ours) │ 50 │ \bf 0.208
2025TV(Ens, Exps) baselineAAC15.0 ×10−4Results averaged over four experimental setups. Expert assessments supply aleatoric unc…Improving Uncertainty Estimation with Confidence-Aware Training Data
Source quote
L408: 15.0
2025TV(Ens, Ens) baselineAAC24.3 ×10−4Ensemble estimates are used for both epistemic and aleatoric uncertainty; results avera…Improving Uncertainty Estimation with Confidence-Aware Training Data
Source quote
L400: 24.3
2025DPersona baselineGeneralized Energy Distance (GED) ↓0.144LIDC–IDRI results; GED as reported in the comparison table.ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image Segmentation
Source quote
L149: DPersona~\cite{wu2024diversified} │ 0.144 │ 90.31 │ 90.38 │ 89.17 │ 89.17
2025DPersona baselineMean Dice ↑89.17LIDC–IDRI results; Mean Dice across annotators or institutions.ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image Segmentation
Source quote
L149: DPersona~\cite{wu2024diversified} │ 0.144 │ 90.31 │ 90.38 │ 89.17 │ 89.17
2025second-best method baselineGED_10 (Generalized Energy Distance)0.1461split: val · samples=10 · evaluation=4-fold-cross-validationDiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion Model
Source quote
L119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358).
2025second-best method baselineGED_30 (Generalized Energy Distance)0.1375split: val · samples=30 · evaluation=4-fold-cross-validationDiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion Model
Source quote
L119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358).
2025second-best method baselineGED_50 (Generalized Energy Distance)0.1358split: val · samples=50 · evaluation=4-fold-cross-validationDiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion Model
Source quote
L119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358).
2025Med3D with fixed threshold baselineECR0.4783backbone=Med3D · threshold=fixedConformal Lesion Segmentation for 3D Medical Images
Source quote
L282: After applying CLS calibration at a risk level of \alpha = 0.2, ECR improves substantially and consistently, achieving gains of over +0.45 absolute improvement on average. For example, the ECR of Med3D on LIDC-IDRI increases from 0.4783 to 0.8137, while Swin-UNETR on KiTS21 jumps from 0.4081 to 0.8289, indicating a near doubling in lesion coverage. These results confirm that CLS not only enforces failure rate constraints but also enhances practical segmentation quality.
2024OSEM-CPNN proposedPSNR36.49 dBsplit: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50A Low-dose CT Reconstruction Network Based on TV-regularized OSEM Algorithm
Source quote
L374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M
2024OSEM-CPNN proposedSSIM0.950split: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50A Low-dose CT Reconstruction Network Based on TV-regularized OSEM Algorithm
Source quote
L374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M
2024CcCL-assisted CdTransformer proposedAUC improvement4.55%Table 5 reports the improvement on LIDC-IDRI relative to the baseline; the text does no…Class-consistent Contrastive Learning Driven Cross-dimensional Transformer for 3D Medical Image Classification
Source quote
L685: Table 5. The CcCL assists CdTransformer to obtain an improvement on AUC, ACC, Precision, and F1-Score on the six 3D medical datasets. The CcCL assists CdTransformer in obtaining a 4.55%, 4.82%, 8.18%, and 4.39% improvement on AUC, ACC, Precision, and F1-Score on LIDC-IDRI dataset. What’s more, in the five 3D MedMNIST, CcCL also improved the performance of model.
2024CcCL-assisted CdTransformer proposedACC improvement4.82%Table 5 reports the improvement on LIDC-IDRI relative to the baseline; the text does no…Class-consistent Contrastive Learning Driven Cross-dimensional Transformer for 3D Medical Image Classification
Source quote
L685: Table 5. The CcCL assists CdTransformer to obtain an improvement on AUC, ACC, Precision, and F1-Score on the six 3D medical datasets. The CcCL assists CdTransformer in obtaining a 4.55%, 4.82%, 8.18%, and 4.39% improvement on AUC, ACC, Precision, and F1-Score on LIDC-IDRI dataset. What’s more, in the five 3D MedMNIST, CcCL also improved the performance of model.
2024UA-SAM (Uncertainty-aware Adapter) proposedDice Score0.887split: test · prompt=single-point · samples=4 · backbone=SAM ViT-B · resolution=128×128 · aggregation=majority-voteUncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image Segmentation
Source quote
L110: \multicolumn{1}{c|}{} │ UA-SAM(ours) │ 0.887 │ 0.856
2024OW-CNFs proposedPSNR33.14 dBsplit: test · I0=1×10^4Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing Flows
Source quote
L272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819
2024OW-CNFs proposedSSIM0.819split: test · I0=1×10^4Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing Flows
Source quote
L272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819
2024Lung nodule detection model non-standard sliceAP@IoU=0.565.63split: val · subset=201 CTs; 399 solid nodulesEXACT-Net: EHR-guided lung tumor auto-segmentation for non-small cell lung cancer radiotherapy
Source quote
L189: Lung Nodule │ 65.63 │ 59.15
2024Lung nodule detection model non-standard sliceAP@IoU=0.759.15split: val · subset=201 CTs; 399 solid nodulesEXACT-Net: EHR-guided lung tumor auto-segmentation for non-small cell lung cancer radiotherapy
Source quote
L189: Lung Nodule │ 65.63 │ 59.15
2024D-Persona (Stage I, #50)GED ↓0.1358split: valDiversified and personalized multi-rater medical image segmentation
Source quote
L215: D-Persona (Stage \uppercase\expandafter{\romannumeral1}, \#50) │ 0.1358 │ 90.45 │ 91.37 │ 91.33 │ CM-Global \cite{tanno2019learning} │ 0.2432 │ 88.53 │ 87.51 │ 87.51 │ 86.13 │ 88.76 │ 88.99 │ 86.18 │ 87.51
2024S\textsuperscript{3}TU-NetDSC89.04%LIDC-IDRI nodules annotated by at least two radiologists; 1,303 nodules across 6,474 CT…S3TU-Net: Structured Convolution and Superpixel Transformer for Lung Nodule Segmentation
Source quote
L331: Key components such as DWF-Conv and D\textsuperscript{2}BR-Conv blocks improve global information representation and mitigate overfitting, while RM-SViT captures long-range dependencies efficiently through sparse correlation and multi-branch attention. Furthermore, the S\textsuperscript{2}-MLP Link module facilitates multi-scale feature transmission and minimizes information loss. On the LIDC-IDRI dataset, S\textsuperscript{3}TU-Net achieved a DSC of 89.04%, precision of 90.73%, IoU of 90.70%, and sensitivity of 93.70%. On the EPDB dataset, it achieved a DSC of 86.40% and an accuracy of 98.53%, demonstrating robust segmentation performance and strong generalization ability.
2024S\textsuperscript{3}TU-Netprecision90.73%LIDC-IDRI nodules annotated by at least two radiologists; 1,303 nodules across 6,474 CT…S3TU-Net: Structured Convolution and Superpixel Transformer for Lung Nodule Segmentation
Source quote
L331: Key components such as DWF-Conv and D\textsuperscript{2}BR-Conv blocks improve global information representation and mitigate overfitting, while RM-SViT captures long-range dependencies efficiently through sparse correlation and multi-branch attention. Furthermore, the S\textsuperscript{2}-MLP Link module facilitates multi-scale feature transmission and minimizes information loss. On the LIDC-IDRI dataset, S\textsuperscript{3}TU-Net achieved a DSC of 89.04%, precision of 90.73%, IoU of 90.70%, and sensitivity of 93.70%. On the EPDB dataset, it achieved a DSC of 86.40% and an accuracy of 98.53%, demonstrating robust segmentation performance and strong generalization ability.
2024S\textsuperscript{3}TU-NetIoU90.70%LIDC-IDRI nodules annotated by at least two radiologists; 1,303 nodules across 6,474 CT…S3TU-Net: Structured Convolution and Superpixel Transformer for Lung Nodule Segmentation
Source quote
L331: Key components such as DWF-Conv and D\textsuperscript{2}BR-Conv blocks improve global information representation and mitigate overfitting, while RM-SViT captures long-range dependencies efficiently through sparse correlation and multi-branch attention. Furthermore, the S\textsuperscript{2}-MLP Link module facilitates multi-scale feature transmission and minimizes information loss. On the LIDC-IDRI dataset, S\textsuperscript{3}TU-Net achieved a DSC of 89.04%, precision of 90.73%, IoU of 90.70%, and sensitivity of 93.70%. On the EPDB dataset, it achieved a DSC of 86.40% and an accuracy of 98.53%, demonstrating robust segmentation performance and strong generalization ability.
2024S\textsuperscript{3}TU-Netsensitivity93.70%LIDC-IDRI nodules annotated by at least two radiologists; 1,303 nodules across 6,474 CT…S3TU-Net: Structured Convolution and Superpixel Transformer for Lung Nodule Segmentation
Source quote
L331: Key components such as DWF-Conv and D\textsuperscript{2}BR-Conv blocks improve global information representation and mitigate overfitting, while RM-SViT captures long-range dependencies efficiently through sparse correlation and multi-branch attention. Furthermore, the S\textsuperscript{2}-MLP Link module facilitates multi-scale feature transmission and minimizes information loss. On the LIDC-IDRI dataset, S\textsuperscript{3}TU-Net achieved a DSC of 89.04%, precision of 90.73%, IoU of 90.70%, and sensitivity of 93.70%. On the EPDB dataset, it achieved a DSC of 86.40% and an accuracy of 98.53%, demonstrating robust segmentation performance and strong generalization ability.
2024SCA-VNet baselineDSC87.50%split: testMedical artificial intelligence for early detection of lung cancer: A survey
Source quote
L296: Liu et al. {\cite{liu2024multiscale}} │ 2024 │ LIDC-IDRI │ SCA-VNet │ Residual edge enhancement │ PyTorch 1.12.1 │ DSC: 87.50% ; Sensitivity: 86.80% ; Precision: 88.32%
2024DCNN (Suresh et al.) baselineACC97.80%Benign-versus-malignant classification; the cited table does not specify a split.Medical artificial intelligence for early detection of lung cancer: A survey
Source quote
L379: Suresh et al. {\cite{suresh2022nroi}} │ 2022 │ LIDC-IDRI │ benign or Malignant │ DCNN │ Non-cancerous, malignant classification │ MATLAB 2018b; GTX 960, 8 GB │ ACC: 97.80% ; SEN: 97.10% ; AUC: 0.9956 ; SPE: 97.20%
2024Deterministic baselineDice0.710split: test · folds=4 · epochs=50 · patch-size=128×128 · resolution=128x128Sparse Bayesian Networks: Efficient Uncertainty Quantification in Medical Image Analysis
Source quote
L77: Deterministic │ \multicolumn{1}{l|}{0.899} │ \multicolumn{1}{l|}{0.098} │ 0.493 │ \multicolumn{1}{l|}{0.710} │ \multicolumn{1}{l|}{0.075} │ 0.007 │ \multicolumn{1}{l|}{0.801} │ \multicolumn{1}{l|}{0.110} │ 0.151 │ 1×
2024Deterministic baselineBrier0.075split: test · folds=4 · epochs=50 · patch-size=128×128 · resolution=128x128Sparse Bayesian Networks: Efficient Uncertainty Quantification in Medical Image Analysis
Source quote
L77: Deterministic │ \multicolumn{1}{l|}{0.899} │ \multicolumn{1}{l|}{0.098} │ 0.493 │ \multicolumn{1}{l|}{0.710} │ \multicolumn{1}{l|}{0.075} │ 0.007 │ \multicolumn{1}{l|}{0.801} │ \multicolumn{1}{l|}{0.110} │ 0.151 │ 1×
2024MRNet baselineDice Score0.878split: test · resolution=128×128Uncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image Segmentation
Source quote
L109: \multicolumn{1}{c|}{} │ MRNet \cite{ji2021learning} │ 0.878 │ 0.849
2024Adapter-SAM baselineDice Score0.861split: test · resolution=128×128Uncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image Segmentation
Source quote
L104: \multicolumn{1}{c|}{} │ Adapter-SAM │ 0.861 │ 0.823
2023UGMCS-Net proposedDSC59.55%split: val · subset=nodules with U-Net DSC ≤60%Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention Mechanism
Source quote
L484: \makecell[l]{UGMCS-Net} │ 70.42 │ 55.5 │ 56.95 │ 41.57 │ 63.17 │ 47.68 │ 46.64 │ 32.52 │ 60.59 │ 44.94 │ 59.55\textcolor{green}{\uparrow5.45} │ 44.44\textcolor{green}{\uparrow5.61}
2023UGMCS-Net proposedDSC70.39%split: val · subset=nodules with U-Net DSC ≤70%Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention Mechanism
Source quote
L492: \makecell[l]{UGMCS-Net} │ 74.09 │ 60.02 │ 69.32 │ 54.74 │ 72.02 │ 57.62 │ 65.90 │ 50.99 │ 70.60 │ 56.05 │ 70.39\textcolor{green}{\uparrow5.07} │ 55.88\textcolor{green}{\uparrow5.79}
2023UGMCS-Net proposedDSC77.08%split: val · subset=nodules with U-Net DSC ≤80%Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention Mechanism
Source quote
L500: \makecell[l]{UGMCS-Net} │ 79.11 │ 66.21 │ 77.16 │ 63.63 │ 77.27 │ 63.70 │ 74.49 │ 60.64 │ 77.53 │ 64.00 │ 77.08\textcolor{green}{\uparrow1.64} │ 63.64\textcolor{green}{\uparrow2.04}
2023VAE U-net (Proposed) proposed non-standard sliceGED0.2888split: test · subset=cases where all four experts agreed a lung lesion was presentHierarchical Uncertainty Estimation for Medical Image Segmentation Networks
Source quote
L102: VAE U-net (Proposed) │ 0.2888 │ 0.7087 │ 20.08 M
2023VAE U-net (Proposed) proposed non-standard sliceNCC0.7087split: test · subset=cases where all four experts agreed a lung lesion was presentHierarchical Uncertainty Estimation for Medical Image Segmentation Networks
Source quote
L102: VAE U-net (Proposed) │ 0.2888 │ 0.7087 │ 20.08 M
2023CIMD (Collectively Intelligent Medical Diffusion) proposedCI0.759CIMD ablation-study result; the cited table does not specify split or inference samplin…Ambiguous Medical Image Segmentation Using Diffusion Models
Source quote
L256: CIMD (Ours) │ 0.321 │ 0.759 │ 0.915
2023CIMD (Collectively Intelligent Medical Diffusion) proposedD-max0.915CIMD ablation-study result; the cited table does not specify split or inference samplin…Ambiguous Medical Image Segmentation Using Diffusion Models
Source quote
L256: CIMD (Ours) │ 0.321 │ 0.759 │ 0.915
2023Conditional VQ-code diffusion transformer proposedDensity (D)1.17modality=chest · evaluation-view=2D-MIPUnaligned 2D to 3D Translation with Conditional Vector-Quantized Code Diffusion using Transformers
Source quote
L246: 1.17 │ 0.91
2023P-PII (ours), PHiSeg proposedPixel-wise AUROC0.66split: testConfidence-Aware and Self-Supervised Image Anomaly Localisation
Source quote
L132: PHiSeg │ 0.76 │ 0.06 │ 0.63 │ 0.93 │ 0.55 │ 0.01 │ 0.55 │ 0.51 │ 0.66 │ 0.01 │ 0.41 │ 0.44
2023Scale-aware super-resolution network with dual affinity learning (proposed method) proposedaverage DSC75.7%split: test · implementation=3DScale-Aware Super-Resolution Network With Dual Affinity Learning for Lesion Segmentation From Medical Images
Source quote
L295: On the LIDC-IDRI dataset, our proposed method achieved an average DSC of 75.7% in the testing set, which was 3.1% higher in DSC, 2.9% higher in IOU than Unet, and 0.9% higher in DSC and 0.7% in IOU than DSRL.
2023OMBA-UNet proposedQ-score0.7576LIDC-IDRI model-comparison evaluation.Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural Networks
Source quote
L347: OMBA-UNet (ours) │ 0.7576 │ 0.3750 │ 0.2915 │ 0.4701
2023OMBA-UNet proposedD^2-GED0.3750LIDC-IDRI model-comparison evaluation.Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural Networks
Source quote
L347: OMBA-UNet (ours) │ 0.7576 │ 0.3750 │ 0.2915 │ 0.4701
2023OMBA-UNet proposedSample Similarity0.4701LIDC-IDRI model-comparison evaluation.Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural Networks
Source quote
L347: OMBA-UNet (ours) │ 0.7576 │ 0.3750 │ 0.2915 │ 0.4701
2023PII, PHiSegPixel-wise AUROC0.43split: testConfidence-Aware and Self-Supervised Image Anomaly Localisation
Source quote
L129: PHiSeg │ 0.67 │ 0.00 │ 0.51 │ 0.90 │ 0.41 │ 0.01 │ 0.47 │ 0.48 │ 0.43 │ 0.00 │ 0.52 │ 0.50
2023Noisy baselineMSE28.282split: test · evaluation=noisy-consensusMAGI: Multi-Annotated Explanation-Guided Learning
Source quote
L408: 28.282
2023Attention U-Net baselineDSC54.10%split: val · subset=nodules with U-Net DSC ≤60%Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention Mechanism
Source quote
L481: \makecell[l]{Attention U-Net} │ 64.30 │ 48.08 │ 58.07 │ 42.36 │ 53.13 │ 36.28 │ 53.28 │ 40.66 │ 41.74 │ 26.78 │ 54.10 │ 38.83
2023Attention U-Net baselineDSC65.32%split: val · subset=nodules with U-Net DSC ≤70%Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention Mechanism
Source quote
L489: \makecell[l]{Attention U-Net} │ 69.44 │ 54.26 │ 63.50 │ 47.93 │ 64.75 │ 48.64 │ 66.27 │ 52.33 │ 62.64 │ 47.28 │ 65.32 │ 50.09
2023Attention U-Net baselineDSC75.44%split: val · subset=nodules with U-Net DSC ≤80%Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention Mechanism
Source quote
L497: \makecell[l]{Attention U-Net} │ 75.55 │ 61.47 │ 74.11 │ 59.89 │ 76.45 │ 62.92 │ 76.02 │ 62.73 │ 75.06 │ 61.01 │ 75.44 │ 61.60
2023PHiSeg (L=5) baseline non-standard sliceGED0.3225split: test · subset=test subsetHierarchical Uncertainty Estimation for Medical Image Segmentation Networks
Source quote
L100: PHiSeg (L=5) \cite{PhiSeg2019} │ 0.3225 │ 0.7337 │ 54.37 M
2023PHiSeg (L=5) baseline non-standard sliceNCC0.7337split: test · subset=test subsetHierarchical Uncertainty Estimation for Medical Image Segmentation Networks
Source quote
L100: PHiSeg (L=5) \cite{PhiSeg2019} │ 0.3225 │ 0.7337 │ 54.37 M
2023X2CT-GAN baselineDensity (D)0.96modality=chest · evaluation-view=2D-MIPUnaligned 2D to 3D Translation with Conditional Vector-Quantized Code Diffusion using Transformers
Source quote
L234: 0.96 │ 0.85
2023PHiSeg (*) baselineQ-score0.7067LIDC-IDRI model-comparison evaluation; re-implemented by the authors.Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural Networks
Source quote
L342: PHiSeg (*) \citep{baumgartner2019phiseg} │ 0.7067 │ 0.3861 │ 0.4021 │ 0.4093
2023PHiSeg (*) baselineD^2-GED0.3861LIDC-IDRI model-comparison evaluation; re-implemented by the authors.Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural Networks
Source quote
L342: PHiSeg (*) \citep{baumgartner2019phiseg} │ 0.7067 │ 0.3861 │ 0.4021 │ 0.4093
2023PHiSeg (*) baselineSample Similarity0.4093LIDC-IDRI model-comparison evaluation; re-implemented by the authors.Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural Networks
Source quote
L342: PHiSeg (*) \citep{baumgartner2019phiseg} │ 0.7067 │ 0.3861 │ 0.4021 │ 0.4093
2022GIIR (Geometry-Informed Image Reconstruction) proposedNRMSE0.3684split: test · views=1 · projection=AP (0°)A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L294: 0.3684
2022GIIR (Geometry-Informed Image Reconstruction) proposedNRMSE0.3000split: test · views=2 · projections=AP and lateral (90°)A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L297: 0.3000
2022GIIR (Geometry-Informed Image Reconstruction) proposedNRMSE0.2740split: test · views=3 · projection_distribution=evenly distributed over 360°A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L300: 0.2740
2022MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposedMAE [HU]38.80 HUsplit: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1038: MAE [HU] │ 272.9 │ 38.80
2022MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposedSSIM0.924split: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1039: SSIM │ 0.362 │ 0.924
2022MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposedSNR [dB]20.50 dBsplit: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1040: SNR [dB] │ 6.00 │ 20.50
2022C,S,F,ad-CSL proposedAUC96.10%split: val · 5-fold-cross-validation · delta=0.5 · subset=unsure data · variant=ad-CSL · scenario=12/45Faithful learning with sure data for lung nodule diagnosis
Source quote
L624: \multicolumn{1}{l}{} │ C,S,F,ad-CSL │ 85.54 │ 96.81 │ 95.85 │ 88.85 │ 91.67 │ 96.10 │ 90.38
2022C,S,F,ad-CSL proposedF190.38%split: val · 5-fold-cross-validation · delta=0.5 · subset=unsure data · variant=ad-CSL · scenario=12/45Faithful learning with sure data for lung nodule diagnosis
Source quote
L624: \multicolumn{1}{l}{} │ C,S,F,ad-CSL │ 85.54 │ 96.81 │ 95.85 │ 88.85 │ 91.67 │ 96.10 │ 90.38
2022Baseline (without geometric priors) ablationNRMSE0.3961split: test · views=1 · projection=AP (0°)A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L264: 0.3961
2022Baseline (without geometric priors) ablationNRMSE0.3927split: test · views=2 · projections=AP and lateral (90°)A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L267: 0.3927
2022Baseline (without geometric priors) ablationNRMSE0.3841split: test · views=3 · projection_distribution=evenly distributed over 360°A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L270: 0.3841
2022FBP baselineMAE [HU]272.9 HUsplit: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1038: MAE [HU] │ 272.9 │ 38.80
2022FBP baselineSSIM0.362split: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1039: SSIM │ 0.362 │ 0.924
2022FBP baselineSNR [dB]6.00 dBsplit: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1040: SNR [dB] │ 6.00 │ 20.50
2021UAS-Net (Our Method) proposedDice0.8403annotation-target=intersectionUncertainty-Guided Lung Nodule Segmentation with Feature-Aware Attention
Source quote
L211: Our Method │ 0.8403
2021UAS-Net (Our Method) proposedDice0.8689annotation-target=unionUncertainty-Guided Lung Nodule Segmentation with Feature-Aware Attention
Source quote
L218: Our Method │ 0.8689
2021RNet proposedAUC95.21split: val · 5-fold-cross-validationInterpretative Computer-aided Lung Cancer Diagnosis: from Radiology Analysis to Malignancy Evaluation
Source quote
L191: RNet │ 95.50 │ 89.88 │ 91.01 │ 96.63 │ 95.21
2021R2MNet proposedAUC97.08split: val · 5-fold-cross-validationInterpretative Computer-aided Lung Cancer Diagnosis: from Radiology Analysis to Malignancy Evaluation
Source quote
L192: R2MNet │ 96.63 │ 92.13 │ 91.01 │ 97.75 │ 97.08
2021MOW-Net proposedrecall of the unsure class0.28split: testMeta ordinal weighting net for improving lung nodule classification
Source quote
L151: In our experiments, we mainly focus on the precision of benign class, recall of malignant and unsure classes~\cite{UDM}. We compared our MOW-Net with the state-of-the-art ordinal regression methods and the normal CE loss. In Table~\ref{tab:results}, we can see that the MOW-Net achieves the best accuracy by a large margin against other methods. Specifically, the MOW-Net significantly improves the recall of the unsure class by 0.28 over the previous best result. This is significant for the clinical diagnosis since a higher recall of the unsure class can encourage more follow-ups and reduce the probabilities of the nodules that are misdiagnosed as malignant or benign. In addition, the precision of benign and the recall of the malignant get a great improvement.
2021IG (Bayesian approach to prevalence-bias) proposed non-standard sliceAccHO0.86folds=3 · prevalence=0.075 · ground_truth=binarizedBayesian analysis of the prevalence bias: learning and predicting from imbalanced data
Source quote
L717: 0.86
2021IG (Bayesian approach to prevalence-bias) proposed non-standard sliceTNR0.82folds=3 · prevalence=0.075 · ground_truth=binarizedBayesian analysis of the prevalence bias: learning and predicting from imbalanced data
Source quote
L718: 0.82
2021IG (Bayesian approach to prevalence-bias) proposed non-standard sliceTPR0.89folds=3 · prevalence=0.075 · ground_truth=binarizedBayesian analysis of the prevalence bias: learning and predicting from imbalanced data
Source quote
L719: 0.89
2021IG (Bayesian approach to prevalence-bias) proposed non-standard sliceNPVHO0.90folds=3 · prevalence=0.075 · ground_truth=binarizedBayesian analysis of the prevalence bias: learning and predicting from imbalanced data
Source quote
L720: 0.90
2021IG (Bayesian approach to prevalence-bias) proposed non-standard slicePPVHO0.82folds=3 · prevalence=0.075 · ground_truth=binarizedBayesian analysis of the prevalence bias: learning and predicting from imbalanced data
Source quote
L721: 0.82
2021IG (Bayesian approach to prevalence-bias) proposed non-standard sliceAUC0.94folds=3 · prevalence=0.075 · ground_truth=binarizedBayesian analysis of the prevalence bias: learning and predicting from imbalanced data
Source quote
L722: 0.94
2021Medical Matting proposedSAD↓0.0447split: val · validation=four-fold-cross-validation · evaluation-region=uncertain-regions-onlyMedical Matting: A New Perspective on Medical Segmentation with Uncertainty
Source quote
L371: Medical Matting (Ours) │ \bf{0.0447} │ \bf{0.0215} │ \bf{0.0607} │ \bf{0.0378} │ \bf{1.0330} │ \bf{0.0093} │ \bf{0.1729} │ \bf{0.4989} │ \bf{0.4023} │ \bf{0.0451} │ \bf{0.5572} │ \bf{0.4255}
2021Medical Matting proposedMSE↓0.0215split: val · validation=four-fold-cross-validation · evaluation-region=uncertain-regions-onlyMedical Matting: A New Perspective on Medical Segmentation with Uncertainty
Source quote
L371: Medical Matting (Ours) │ \bf{0.0447} │ \bf{0.0215} │ \bf{0.0607} │ \bf{0.0378} │ \bf{1.0330} │ \bf{0.0093} │ \bf{0.1729} │ \bf{0.4989} │ \bf{0.4023} │ \bf{0.0451} │ \bf{0.5572} │ \bf{0.4255}
2021SIB (single Inpainting Block) ablationImage PSNR38.972variant=single Inpainting Block · projection-sampling-interval=4A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT Reconstruction
Source quote
L214: SIB │ 38.972 │ 0.941
2021SIB (single Inpainting Block) ablationImage SSIM0.941variant=single Inpainting Block · projection-sampling-interval=4A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT Reconstruction
Source quote
L214: SIB │ 38.972 │ 0.941
20212D LS-AAE ablationImage PSNR39.472convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT Reconstruction
Source quote
L230: 2D LS-AAE │ 39.472 │ 0.944
20212D LS-AAE ablationImage SSIM0.944convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT Reconstruction
Source quote
L230: 2D LS-AAE │ 39.472 │ 0.944
2021U-Net baselineDice0.8337annotation-target=intersectionUncertainty-Guided Lung Nodule Segmentation with Feature-Aware Attention
Source quote
L208: U-Net │ 0.8337
2021U-Net baselineDice0.8611annotation-target=unionUncertainty-Guided Lung Nodule Segmentation with Feature-Aware Attention
Source quote
L215: U-Net │ 0.8611
2021Dual-Branch U-Net baselineDice0.8698annotation-target=unionUncertainty-Guided Lung Nodule Segmentation with Feature-Aware Attention
Source quote
L216: Dual-Branch U-Net │ 0.8698
2020MCPM (Our MCPM row) proposedDice84.64Dilation-corrupted annotations; r=40% of training images contaminated. Models use the m…Meta Corrupted Pixels Mining for Medical Image Segmentation
Source quote
L185: Our MCPM │ 74.69 │ 84.64 │ 1.7198 │ 75.79 │ 84.99 │ 1.7053
2020MCPM (Our MCPM row) proposedDice84.99ElasticDeform-corrupted annotations; r=40% of training images contaminated. Models use …Meta Corrupted Pixels Mining for Medical Image Segmentation
Source quote
L185: Our MCPM │ 74.69 │ 84.64 │ 1.7198 │ 75.79 │ 84.99 │ 1.7053
2020MWNetDice81.17Dilation-corrupted annotations; r=40% of training images contaminated. Models use the m…Meta Corrupted Pixels Mining for Medical Image Segmentation
Source quote
L184: MWNet │ 71.56 │ 81.17 │ 1.7762 │ 71.89 │ 81.04 │ 1.7680
2020MWNetDice81.04ElasticDeform-corrupted annotations; r=40% of training images contaminated. Models use …Meta Corrupted Pixels Mining for Medical Image Segmentation
Source quote
L184: MWNet │ 71.56 │ 81.17 │ 1.7762 │ 71.89 │ 81.04 │ 1.7680
20203D Multi-Scale + RF [28] baselinemalignancy prediction accuracy86.84%split: valEncoding Visual Attributes in Capsules for Explainable Medical Diagnoses
Source quote
L96: 86.84
20203D Multi-Crop [29] baselinemalignancy prediction accuracy87.14%split: valEncoding Visual Attributes in Capsules for Explainable Medical Diagnoses
Source quote
L104: 87.14
2020CapsNet [25] baselinemalignancy prediction accuracy77.04%split: valEncoding Visual Attributes in Capsules for Explainable Medical Diagnoses
Source quote
L112: 77.04
20203D Dual-Path HSCNN [27] baselinesubtlety (sub) prediction accuracy71.9%split: valEncoding Visual Attributes in Capsules for Explainable Medical Diagnoses
Source quote
L115: 71.9
20203D Dual-Path HSCNN [27] baselinesphericity (sph) prediction accuracy55.2%split: valEncoding Visual Attributes in Capsules for Explainable Medical Diagnoses
Source quote
L116: 55.2
2019Med3D-pretrained 3D-ResNet18 proposedAccuracy88.89%split: test · fine-tuned · classes=binary · backbone=3D-ResNet18Med3D: Transfer Learning for 3D Medical Image Analysis
Source quote
L155: Med3D │ 87.26% │ 88.89%
2019SegCaps baseline non-standard slice3D Dice-score (median)0.9847split: test · test-scans=40 · training-scans=180LGAN: Lung segmentation in CT scans using generative adversarial network
Source quote
L323: SegCaps \cite{lalonde2018capsules} │ 0.9847
2019Kinetics-pretrained 3D-ResNet18 (Kin) baselineAccuracy82.83%split: test · fine-tuned · classes=binary · backbone=3D-ResNet18 · pretraining=KineticsMed3D: Transfer Learning for 3D Medical Image Analysis
Source quote
L154: Kin~\cite{hara3dcnns} │ 83.21% │ 82.83%
20183D CNN MTL with Trace norm proposed non-standard sliceAccuracy80.08%split: val · 10-fold-cross-validation · exclusion=nodules with mean malignancy score 3 · cross-validation=10-fold · correctness-tolerance=within ±1 of ground-truth scoreLung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning Approaches
Source quote
L235: 3D CNN MTL with Trace norm │ 80.08 │ 0.626
20183D ResNet-152 (Raw + Synthesis) proposedACC0.9171split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812
20183D ResNet-152 (Raw + Synthesis) proposedSPE0.9774split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812
20183D ResNet-152 (Raw + Synthesis) proposedAUC0.8812split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812
2018Mean across network architectures (Raw + Synthesis) proposedAUC0.8696split: test · backbone=mean across four 3D CNN architectures · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L139: Mean │ 0.8821 │ 0.6353 │ 0.9266 │ 0.8696
2018GA-SSD proposedCPM0.863Authors report a CPM comparison on the LIDC-IDRI dataset against Wang18.Group-Attention Single-Shot Detector (GA-SSD): Finding Pulmonary Nodules in Large-Scale CT Images
Source quote
L111: To better justify the effectiveness of the proposed method, we conduct experiments over the LIDC-IDRI dataset \cite{armato2011lung} and obtained the competitive result with the state-of-the-art (Wang18 \cite{inbook}) method (CPM scores: 0.863 vs 0.878).
2018Wang18 baselineCPM0.878Authors report a CPM comparison on the LIDC-IDRI dataset against GA-SSD.Group-Attention Single-Shot Detector (GA-SSD): Finding Pulmonary Nodules in Large-Scale CT Images
Source quote
L111: To better justify the effectiveness of the proposed method, we conduct experiments over the LIDC-IDRI dataset \cite{armato2011lung} and obtained the competitive result with the state-of-the-art (Wang18 \cite{inbook}) method (CPM scores: 0.863 vs 0.878).
2017End-to-end detector (proposed) proposedMean FROC score0.608noise=noiseless · projections-per-rotation=144End-to-End Abnormality Detection in Medical Imaging
Source quote
L110: 0.608
2017End-to-end detector (proposed) proposedMean FROC score0.615noise-level-N0=1 × 10^5 · projections-per-rotation=144End-to-End Abnormality Detection in Medical Imaging
Source quote
L115: 0.615