LIDC-IDRI
51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | 2D LS-AAE SOTA frontier (+1 variant) | 0.944 | 2021-01-01 | convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4 · Ablation study with projection-sampling interval 4 (the ablation default); 2D convolu… | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quote2D LS-AAE │ 39.472 │ 0.944 |
| 2 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) | 0.924 | 2022-01-01 | resolution=256×256 · projections=40 · Evaluation on patient datasets unseen during training and validation; images downsamp… | CNN-based regularisation for CT image reconstructionsSource quoteSSIM │ 0.362 │ 0.924 |
| 3 | OW-CNFs | 0.819 | 2024-10-01 | I0=1×10^4 · Average on the LIDC-IDRI test set (30 images); simulated low-dose projections at I0=1… | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteOW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 4 | DVG-Diffusion (+3 variants) | 0.679 | 2025-03-01 | Ablation result; biplanar X-ray inputs; evaluated on the 102-volume test split. | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteDVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35 |
Showing 150 of 161 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Volumetric Directional Diffusion (VDD) proposed | 95% Hausdorff Distance (HD95) | 1.36 | split_ratio=8:1:1 · dimensionality=3D | Volumetric Directional Diffusion: Anchoring Uncertainty Quantification in Anatomical Consensus for Ambiguous Medical Image SegmentationSource quoteL123: As shown in Table~\ref{tab:comprehensive_results}, while deterministic baselines (e.g., nnU-Net 3D) achieve high structural precision (e.g., 0.7671 Dice on LIDC-IDRI ), they fail to capture inter-reader variability. Conversely, slice-wise 2D diffusion models exhibit catastrophic topological degradation, with HD95 scores soaring to 18.05 on LIDC-IDRI and 21.34 on KiTS21. By anchoring the generative trajectory to a 3D structural prior, VDD successfully resolves this trade-off, restoring consistency and slashing HD95 to 1.36 on LIDC-IDRI. Remarkably, VDD remains highly competitive in Dice accuracy and even outperforms nnU-Net 3D on ISBI 2015 (0.6989 vs. 0.6914), proving that residual exploration can refine macroscopic consensus. |
| 2026 | Harmonizer Network (Harmonizer, ours) proposed | DSC | 84.27 | split: test | Harmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical SegmentationSource quoteL416: 89.37 │ 1.44 │ 87.92 │ 2.88 │ 84.27 │ 6.53 |
| 2026 | VIVID-Med proposed | AUC | 0.8413 | modality=CT slices · pretraining-modality=chest X-ray | VIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTsSource quoteL4: Vision-language pretraining has driven significant progress in medical image analysis. However, current methods typically supervise visual encoders using one-hot labels or free-form text, neither of which effectively captures the complex semantic relationships among clinical findings. In this study, we introduce VIVID-Med, a novel framework that leverages a frozen large language model (LLM) as a structured semantic teacher to pretrain medical vision transformers (ViTs). VIVID-Med translates clinical findings into verifiable JSON field-state pairs via a Unified Medical Schema (UMS), utilizing answerability-aware masking to focus optimization. It then employs Structured Prediction Decomposition (SPD) to partition cross-attention into orthogonality-regularized query groups, extracting complementary visual aspects. Crucially, the LLM is discarded post-training, yielding a lightweight, deployable ViT-only backbone. We evaluated VIVID-Med across multiple settings: on CheXpert linear probing, it achieves a macro-AUC of 0.8588, outperforming BiomedCLIP by {+}6.65 points while using 500× less data. It also demonstrates robust zero-shot cross-domain transfer to NIH ChestX-ray14 (0.7225 macro-AUC) and strong cross-modality generalization to CT, achieving 0.8413 AUC on LIDC-IDRI lung nodule classification and 0.9969 macro-AUC on OrganAMNIST 11-organ classification. VIVID-Med offers a highly efficient, scalable alternative to deploying resource-heavy vision-language models in clinical settings. |
| 2026 | D-Persona | DSC | 71.11 | split: test | Harmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical SegmentationSource quoteL411: 85.74 │ 3.43 │ 81.80 │ 7.37 │ 71.11 │ 18.06 |
| 2026 | Harmonizer Network | DSC | 85.30 | split: test | Harmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical SegmentationSource quoteL616: 85.30 │ 5.48 |
| 2026 | D-Persona | DSC | 83.02 | split: test | Harmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical SegmentationSource quoteL613: 83.02 │ 6.15 |
| 2026 | PRDiT-128^{\text{scratch}} | MMD | 0.1853 | 128^3; trained directly at 128^3 (Scratch). | Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume GenerationSource quoteL456: PRDiT-128^{\text{\;scratch}} │ 2.04 │ 0.1853 │ 80 GPUh |
| 2026 | PRDiT-64 ↑ (128) | FID | 2.89 | 128^3; progressive strategy reuses a pretrained 64^3 model and extends it to 128^3; FID… | Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume GenerationSource quoteL457: PRDiT-64\,\uparrow (128) │ 2.89 │ 0.1893 │ 12 GPUh |
| 2026 | PRDiT-64 ↑ (128) | MMD | 0.1893 | 128^3; progressive strategy reuses a pretrained 64^3 model and extends it to 128^3. | Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume GenerationSource quoteL457: PRDiT-64\,\uparrow (128) │ 2.89 │ 0.1893 │ 12 GPUh |
| 2026 | Slice-wise 2D diffusion models baseline | 95% Hausdorff Distance (HD95) | 18.05 | split_ratio=8:1:1 · dimensionality=2D · inference_style=slice-wise | Volumetric Directional Diffusion: Anchoring Uncertainty Quantification in Anatomical Consensus for Ambiguous Medical Image SegmentationSource quoteL123: As shown in Table~\ref{tab:comprehensive_results}, while deterministic baselines (e.g., nnU-Net 3D) achieve high structural precision (e.g., 0.7671 Dice on LIDC-IDRI ), they fail to capture inter-reader variability. Conversely, slice-wise 2D diffusion models exhibit catastrophic topological degradation, with HD95 scores soaring to 18.05 on LIDC-IDRI and 21.34 on KiTS21. By anchoring the generative trajectory to a 3D structural prior, VDD successfully resolves this trade-off, restoring consistency and slashing HD95 to 1.36 on LIDC-IDRI. Remarkably, VDD remains highly competitive in Dice accuracy and even outperforms nnU-Net 3D on ISBI 2015 (0.6989 vs. 0.6914), proving that residual exploration can refine macroscopic consensus. |
| 2025 | TV(Ens, CAE) proposed | AAC | 27.7 ×10−4 | Results averaged over four experimental setups. CAE is trained on expert soft labels an… | Improving Uncertainty Estimation with Confidence-Aware Training DataSource quoteL404: 27.7 |
| 2025 | ProSona (table label: Pro Sona (ours)) proposed | Generalized Energy Distance (GED) ↓ | 0.120 | LIDC–IDRI results; GED as reported in the comparison table. | ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image SegmentationSource quoteL150: Pro\,Sona (ours) │ 0.120 │ 91.56 │ 92.29 │ 90.26 │ 90.26 |
| 2025 | ProSona (table label: Pro Sona (ours)) proposed | Mean Dice ↑ | 90.26 | LIDC–IDRI results; Mean Dice across annotators or institutions. | ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image SegmentationSource quoteL150: Pro\,Sona (ours) │ 0.120 │ 91.56 │ 92.29 │ 90.26 │ 90.26 |
| 2025 | DiffOSeg proposed | GED_10 (Generalized Energy Distance) | 0.0915 | split: val · samples=10 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | DiffOSeg proposed | GED_30 (Generalized Energy Distance) | 0.0773 | split: val · samples=30 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | DiffOSeg proposed | GED_50 (Generalized Energy Distance) | 0.0745 | split: val · samples=50 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | LungNoduleAgent proposed | LungDLC-score | 83.5 | Public benchmark; localized CT report generation. LungDLC evaluates whether description… | LungNoduleAgent: A Collaborative Multi-Agent System for Precision Diagnosis of Lung NodulesSource quoteL259: As demonstrated in \textbf{Table \ref{tab:1}}, LungNoduleAgent exhibits state-of-the-art performance across all three benchmark datasets, with significant improvements on the Qwen and LLaVA base models. Compared with the highest score among other methods, on the PrivateA dataset, it achieves a LungDLC-score of 81.9, reflecting an increase of 6.3. For the PrivateB dataset, the model attains a score of 80.3, marking an improvement of 4.1. This performance advantage is also evident on the public LIDC-IDRI benchmark, where the model scores 83.5, representing 8.3 increasing. |
| 2025 | CLS with Med3D proposed | ECR | 0.8137 | alpha=0.2 · backbone=Med3D | Conformal Lesion Segmentation for 3D Medical ImagesSource quoteL282: After applying CLS calibration at a risk level of \alpha = 0.2, ECR improves substantially and consistently, achieving gains of over +0.45 absolute improvement on average. For example, the ECR of Med3D on LIDC-IDRI increases from 0.4783 to 0.8137, while Swin-UNETR on KiTS21 jumps from 0.4081 to 0.8289, indicating a near doubling in lesion coverage. These results confirm that CLS not only enforces failure rate constraints but also enhances practical segmentation quality. |
| 2025 | CPYOLO proposed | FPS | 137.4 f/s | Table 2 LIDC-IDRI benchmark; no evaluation split is specified in the cited results. | CPLOYO: A pulmonary nodule detection model with multi-scale feature fusion and nonlinear feature learningSource quoteL343: 137.4 |
| 2025 | CLS-DM proposed | PSNR | 27.36 dB | 2-view · views=frontal-and-lateral · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL226: CLS-DM (ours) │ 23.02 │ 0.5931 │ 24.96 │ 0.6585 │ 27.36 │ 0.7058 |
| 2025 | CLS-DM proposed | SSIM | 0.7058 | 2-view · views=frontal-and-lateral · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL226: CLS-DM (ours) │ 23.02 │ 0.5931 │ 24.96 │ 0.6585 │ 27.36 │ 0.7058 |
| 2025 | ProSeg proposed | GED | 0.1152 | Reported for ProSeg on LIDC-IDRI; the results prose does not specify a prior-sampling v… | Probabilistic Modeling of Multi-rater Medical Image Segmentation for Diversity and PersonalizationSource quoteL265: Table. ~\ref{tab_lidc} reports the performance of the different methods in terms of diversity, personalization, and personalized segmentation. Compared to generative methods, our ProSeg consistently achieves the best diversity performance with the lowest GED (0.1152) and the highest soft Dice score D-soft (91.53%), which demonstrates its ability to generate a wide range of meaningful segmentation variations that can significantly improve diversity while maintaining high-quality segmentation. |
| 2025 | ProSeg proposed | Soft Dice Score (D-soft) | 91.53% | thresholds=0.1, 0.3, 0.5, 0.7, 0.9 | Probabilistic Modeling of Multi-rater Medical Image Segmentation for Diversity and PersonalizationSource quoteL265: Table. ~\ref{tab_lidc} reports the performance of the different methods in terms of diversity, personalization, and personalized segmentation. Compared to generative methods, our ProSeg consistently achieves the best diversity performance with the lowest GED (0.1152) and the highest soft Dice score D-soft (91.53%), which demonstrates its ability to generate a wide range of meaningful segmentation variations that can significantly improve diversity while maintaining high-quality segmentation. |
| 2025 | ProSeg proposed | D-max | 91.03% | Reported for ProSeg on LIDC-IDRI; multi-rater personalization metric. | Probabilistic Modeling of Multi-rater Medical Image Segmentation for Diversity and PersonalizationSource quoteL266: In terms of personalization performance, the D-max of ProSeg reaches 91.03%, as it is able to effectively capture expert-specific segmentation patterns in the latent space. |
| 2025 | ProSeg proposed | D-mean | 90.25% | Reported as the average Dice similarity for ProSeg on LIDC-IDRI. | Probabilistic Modeling of Multi-rater Medical Image Segmentation for Diversity and PersonalizationSource quoteL267: In terms of personalized segmentation accuracy, ProSeg achieves state-of-the-art (SOTA) performance with the highest average dice similarity (D-mean = 90.25%) and consistently strong performance across annotators (D\textsubscript{A1} = 89.49%, D\textsubscript{A2} = 90.27%, D\textsubscript{A3} = 91.01%, D\textsubscript{A4} = 90.23%). Besides, by sampling the prior distribution of q(\tau), our ProSeg (prior) achieves a better GED score, since more expert preferences are sampled. |
| 2025 | DVG-Diffusion (90° synthesized view) proposed | PSNR | 22.54 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL273: PSNR \uparrow │ 22.29 │ 22.46 │ 22.47 │ 22.43 │ 22.48 │ 22.54 │ 22.47 |
| 2025 | DVG-Diffusion (90° synthesized view) proposed | SSIM | 0.541 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537 |
| 2025 | TV(Ens, −) ablation | AAC | 29.4 ×10−4 | Epistemic-only ensemble result, averaged over four experimental setups; scans were divi… | Improving Uncertainty Estimation with Confidence-Aware Training DataSource quoteL396: 29.4 |
| 2025 | Baseline (single-scale mask autoencoder with next-token prediction) ablation | GED | 0.275 | Component ablation; GED subcolumn labeled 16. | Autoregressive Medical Image Segmentation via Next-Scale Mask PredictionSource quoteL146: Baseline │ 0.275 │ 0.310 │ 0.383 │ 0.814 │ 0.557 |
| 2025 | Baseline (single-scale mask autoencoder with next-token prediction) ablation | HM-IoU | 0.557 | Component ablation; HM-IoU subcolumn labeled 16. | Autoregressive Medical Image Segmentation via Next-Scale Mask PredictionSource quoteL146: Baseline │ 0.275 │ 0.310 │ 0.383 │ 0.814 │ 0.557 |
| 2025 | AR-Seg (+ Next-scale autoregressive) ablation | GED | 0.239 | Component ablation; next-scale autoregressive row; GED subcolumn labeled 16. | Autoregressive Medical Image Segmentation via Next-Scale Mask PredictionSource quoteL147: \quad+ Next-scale autoregressive │ 0.239 │ 0.277 │ 0.348 │ 0.745 │ 0.595 |
| 2025 | AR-Seg (+ Next-scale autoregressive) ablation | HM-IoU | 0.595 | Component ablation; next-scale autoregressive row; HM-IoU subcolumn labeled 16. | Autoregressive Medical Image Segmentation via Next-Scale Mask PredictionSource quoteL147: \quad+ Next-scale autoregressive │ 0.239 │ 0.277 │ 0.348 │ 0.745 │ 0.595 |
| 2025 | AR-Seg (+ SVD-based adapter) ablation | GED | 0.232 | Component ablation; next-scale autoregressive framework with SVD-based adapter; GED sub… | Autoregressive Medical Image Segmentation via Next-Scale Mask PredictionSource quoteL148: \quad\quad + SVD-based adapter │ 0.232 │ 0.267 │ 0.332 │ 0.736 │ 0.616 |
| 2025 | AR-Seg (+ SVD-based adapter) ablation | HM-IoU | 0.616 | Component ablation; next-scale autoregressive framework with SVD-based adapter; HM-IoU … | Autoregressive Medical Image Segmentation via Next-Scale Mask PredictionSource quoteL148: \quad\quad + SVD-based adapter │ 0.232 │ 0.267 │ 0.332 │ 0.736 │ 0.616 |
| 2025 | w/o CLIP ablation | PSNR | 25.37 dB | 2-view · views=frontal-and-lateral · variant=without-contrastive-learning · backbone=CLIP · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL221: w/o CLIP │ 22.42 │ 0.5919 │ 25.17 │ 0.6591 │ 25.37 │ 0.6701 |
| 2025 | w/o CLIP ablation | SSIM | 0.6701 | 2-view · views=frontal-and-lateral · variant=without-contrastive-learning · backbone=CLIP · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL221: w/o CLIP │ 22.42 │ 0.5919 │ 25.17 │ 0.6591 │ 25.37 │ 0.6701 |
| 2025 | w/o CLIP, AR (LDM) ablation | PSNR | 24.94 dB | 2-view · views=frontal-and-lateral · variant=without-contrastive-learning-and-autoregressive-constraint · backbone=LDM · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL225: w/o CLIP,AR(LDM) │ 20.65 │ 0.5864 │ 24.73 │ 0.6473 │ 24.94 │ 0.6515 |
| 2025 | w/o CLIP, AR (LDM) ablation | SSIM | 0.6515 | 2-view · views=frontal-and-lateral · variant=without-contrastive-learning-and-autoregressive-constraint · backbone=LDM · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL225: w/o CLIP,AR(LDM) │ 20.65 │ 0.5864 │ 24.73 │ 0.6473 │ 24.94 │ 0.6515 |
| 2025 | DVG-Diffusion ablation | SSIM | 0.679 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL228: DVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35 |
| 2025 | VPGE-Diffusion ablation | SSIM | 0.667 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL227: \checkmark │ 26.47 │ 0.667 │ 28.11 |
| 2025 | DVG-Diffusion (without new-view input) ablation | PSNR | 22.29 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL273: PSNR \uparrow │ 22.29 │ 22.46 │ 22.47 │ 22.43 │ 22.48 │ 22.54 │ 22.47 |
| 2025 | DVG-Diffusion (without new-view input) ablation | SSIM | 0.532 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537 |
| 2025 | SSB++ | GED | 0.208 | split: test | Ambiguous Medical Image Segmentation Using Diffusion Schrödinger BridgeSource quoteL160: SSB++ (Ours) │ 50 │ \bf 0.208 |
| 2025 | TV(Ens, Exps) baseline | AAC | 15.0 ×10−4 | Results averaged over four experimental setups. Expert assessments supply aleatoric unc… | Improving Uncertainty Estimation with Confidence-Aware Training DataSource quoteL408: 15.0 |
| 2025 | TV(Ens, Ens) baseline | AAC | 24.3 ×10−4 | Ensemble estimates are used for both epistemic and aleatoric uncertainty; results avera… | Improving Uncertainty Estimation with Confidence-Aware Training DataSource quoteL400: 24.3 |
| 2025 | DPersona baseline | Generalized Energy Distance (GED) ↓ | 0.144 | LIDC–IDRI results; GED as reported in the comparison table. | ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image SegmentationSource quoteL149: DPersona~\cite{wu2024diversified} │ 0.144 │ 90.31 │ 90.38 │ 89.17 │ 89.17 |
| 2025 | DPersona baseline | Mean Dice ↑ | 89.17 | LIDC–IDRI results; Mean Dice across annotators or institutions. | ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image SegmentationSource quoteL149: DPersona~\cite{wu2024diversified} │ 0.144 │ 90.31 │ 90.38 │ 89.17 │ 89.17 |
| 2025 | second-best method baseline | GED_10 (Generalized Energy Distance) | 0.1461 | split: val · samples=10 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | second-best method baseline | GED_30 (Generalized Energy Distance) | 0.1375 | split: val · samples=30 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | second-best method baseline | GED_50 (Generalized Energy Distance) | 0.1358 | split: val · samples=50 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | Med3D with fixed threshold baseline | ECR | 0.4783 | backbone=Med3D · threshold=fixed | Conformal Lesion Segmentation for 3D Medical ImagesSource quoteL282: After applying CLS calibration at a risk level of \alpha = 0.2, ECR improves substantially and consistently, achieving gains of over +0.45 absolute improvement on average. For example, the ECR of Med3D on LIDC-IDRI increases from 0.4783 to 0.8137, while Swin-UNETR on KiTS21 jumps from 0.4081 to 0.8289, indicating a near doubling in lesion coverage. These results confirm that CLS not only enforces failure rate constraints but also enhances practical segmentation quality. |
| 2024 | OSEM-CPNN proposed | PSNR | 36.49 dB | split: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50 | A Low-dose CT Reconstruction Network Based on TV-regularized OSEM AlgorithmSource quoteL374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M |
| 2024 | OSEM-CPNN proposed | SSIM | 0.950 | split: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50 | A Low-dose CT Reconstruction Network Based on TV-regularized OSEM AlgorithmSource quoteL374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M |
| 2024 | CcCL-assisted CdTransformer proposed | AUC improvement | 4.55% | Table 5 reports the improvement on LIDC-IDRI relative to the baseline; the text does no… | Class-consistent Contrastive Learning Driven Cross-dimensional Transformer for 3D Medical Image ClassificationSource quoteL685: Table 5. The CcCL assists CdTransformer to obtain an improvement on AUC, ACC, Precision, and F1-Score on the six 3D medical datasets. The CcCL assists CdTransformer in obtaining a 4.55%, 4.82%, 8.18%, and 4.39% improvement on AUC, ACC, Precision, and F1-Score on LIDC-IDRI dataset. What’s more, in the five 3D MedMNIST, CcCL also improved the performance of model. |
| 2024 | CcCL-assisted CdTransformer proposed | ACC improvement | 4.82% | Table 5 reports the improvement on LIDC-IDRI relative to the baseline; the text does no… | Class-consistent Contrastive Learning Driven Cross-dimensional Transformer for 3D Medical Image ClassificationSource quoteL685: Table 5. The CcCL assists CdTransformer to obtain an improvement on AUC, ACC, Precision, and F1-Score on the six 3D medical datasets. The CcCL assists CdTransformer in obtaining a 4.55%, 4.82%, 8.18%, and 4.39% improvement on AUC, ACC, Precision, and F1-Score on LIDC-IDRI dataset. What’s more, in the five 3D MedMNIST, CcCL also improved the performance of model. |
| 2024 | UA-SAM (Uncertainty-aware Adapter) proposed | Dice Score | 0.887 | split: test · prompt=single-point · samples=4 · backbone=SAM ViT-B · resolution=128×128 · aggregation=majority-vote | Uncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image SegmentationSource quoteL110: \multicolumn{1}{c|}{} │ UA-SAM(ours) │ 0.887 │ 0.856 |
| 2024 | OW-CNFs proposed | PSNR | 33.14 dB | split: test · I0=1×10^4 | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteL272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 2024 | OW-CNFs proposed | SSIM | 0.819 | split: test · I0=1×10^4 | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteL272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 2024 | Lung nodule detection model non-standard slice | AP@IoU=0.5 | 65.63 | split: val · subset=201 CTs; 399 solid nodules | EXACT-Net: EHR-guided lung tumor auto-segmentation for non-small cell lung cancer radiotherapySource quoteL189: Lung Nodule │ 65.63 │ 59.15 |
| 2024 | Lung nodule detection model non-standard slice | AP@IoU=0.7 | 59.15 | split: val · subset=201 CTs; 399 solid nodules | EXACT-Net: EHR-guided lung tumor auto-segmentation for non-small cell lung cancer radiotherapySource quoteL189: Lung Nodule │ 65.63 │ 59.15 |
| 2024 | D-Persona (Stage I, #50) | GED ↓ | 0.1358 | split: val | Diversified and personalized multi-rater medical image segmentationSource quoteL215: D-Persona (Stage \uppercase\expandafter{\romannumeral1}, \#50) │ 0.1358 │ 90.45 │ 91.37 │ 91.33 │ CM-Global \cite{tanno2019learning} │ 0.2432 │ 88.53 │ 87.51 │ 87.51 │ 86.13 │ 88.76 │ 88.99 │ 86.18 │ 87.51 |
| 2024 | S\textsuperscript{3}TU-Net | DSC | 89.04% | LIDC-IDRI nodules annotated by at least two radiologists; 1,303 nodules across 6,474 CT… | S3TU-Net: Structured Convolution and Superpixel Transformer for Lung Nodule SegmentationSource quoteL331: Key components such as DWF-Conv and D\textsuperscript{2}BR-Conv blocks improve global information representation and mitigate overfitting, while RM-SViT captures long-range dependencies efficiently through sparse correlation and multi-branch attention. Furthermore, the S\textsuperscript{2}-MLP Link module facilitates multi-scale feature transmission and minimizes information loss. On the LIDC-IDRI dataset, S\textsuperscript{3}TU-Net achieved a DSC of 89.04%, precision of 90.73%, IoU of 90.70%, and sensitivity of 93.70%. On the EPDB dataset, it achieved a DSC of 86.40% and an accuracy of 98.53%, demonstrating robust segmentation performance and strong generalization ability. |
| 2024 | S\textsuperscript{3}TU-Net | precision | 90.73% | LIDC-IDRI nodules annotated by at least two radiologists; 1,303 nodules across 6,474 CT… | S3TU-Net: Structured Convolution and Superpixel Transformer for Lung Nodule SegmentationSource quoteL331: Key components such as DWF-Conv and D\textsuperscript{2}BR-Conv blocks improve global information representation and mitigate overfitting, while RM-SViT captures long-range dependencies efficiently through sparse correlation and multi-branch attention. Furthermore, the S\textsuperscript{2}-MLP Link module facilitates multi-scale feature transmission and minimizes information loss. On the LIDC-IDRI dataset, S\textsuperscript{3}TU-Net achieved a DSC of 89.04%, precision of 90.73%, IoU of 90.70%, and sensitivity of 93.70%. On the EPDB dataset, it achieved a DSC of 86.40% and an accuracy of 98.53%, demonstrating robust segmentation performance and strong generalization ability. |
| 2024 | S\textsuperscript{3}TU-Net | IoU | 90.70% | LIDC-IDRI nodules annotated by at least two radiologists; 1,303 nodules across 6,474 CT… | S3TU-Net: Structured Convolution and Superpixel Transformer for Lung Nodule SegmentationSource quoteL331: Key components such as DWF-Conv and D\textsuperscript{2}BR-Conv blocks improve global information representation and mitigate overfitting, while RM-SViT captures long-range dependencies efficiently through sparse correlation and multi-branch attention. Furthermore, the S\textsuperscript{2}-MLP Link module facilitates multi-scale feature transmission and minimizes information loss. On the LIDC-IDRI dataset, S\textsuperscript{3}TU-Net achieved a DSC of 89.04%, precision of 90.73%, IoU of 90.70%, and sensitivity of 93.70%. On the EPDB dataset, it achieved a DSC of 86.40% and an accuracy of 98.53%, demonstrating robust segmentation performance and strong generalization ability. |
| 2024 | S\textsuperscript{3}TU-Net | sensitivity | 93.70% | LIDC-IDRI nodules annotated by at least two radiologists; 1,303 nodules across 6,474 CT… | S3TU-Net: Structured Convolution and Superpixel Transformer for Lung Nodule SegmentationSource quoteL331: Key components such as DWF-Conv and D\textsuperscript{2}BR-Conv blocks improve global information representation and mitigate overfitting, while RM-SViT captures long-range dependencies efficiently through sparse correlation and multi-branch attention. Furthermore, the S\textsuperscript{2}-MLP Link module facilitates multi-scale feature transmission and minimizes information loss. On the LIDC-IDRI dataset, S\textsuperscript{3}TU-Net achieved a DSC of 89.04%, precision of 90.73%, IoU of 90.70%, and sensitivity of 93.70%. On the EPDB dataset, it achieved a DSC of 86.40% and an accuracy of 98.53%, demonstrating robust segmentation performance and strong generalization ability. |
| 2024 | SCA-VNet baseline | DSC | 87.50% | split: test | Medical artificial intelligence for early detection of lung cancer: A surveySource quoteL296: Liu et al. {\cite{liu2024multiscale}} │ 2024 │ LIDC-IDRI │ SCA-VNet │ Residual edge enhancement │ PyTorch 1.12.1 │ DSC: 87.50% ; Sensitivity: 86.80% ; Precision: 88.32% |
| 2024 | DCNN (Suresh et al.) baseline | ACC | 97.80% | Benign-versus-malignant classification; the cited table does not specify a split. | Medical artificial intelligence for early detection of lung cancer: A surveySource quoteL379: Suresh et al. {\cite{suresh2022nroi}} │ 2022 │ LIDC-IDRI │ benign or Malignant │ DCNN │ Non-cancerous, malignant classification │ MATLAB 2018b; GTX 960, 8 GB │ ACC: 97.80% ; SEN: 97.10% ; AUC: 0.9956 ; SPE: 97.20% |
| 2024 | Deterministic baseline | Dice | 0.710 | split: test · folds=4 · epochs=50 · patch-size=128×128 · resolution=128x128 | Sparse Bayesian Networks: Efficient Uncertainty Quantification in Medical Image AnalysisSource quoteL77: Deterministic │ \multicolumn{1}{l|}{0.899} │ \multicolumn{1}{l|}{0.098} │ 0.493 │ \multicolumn{1}{l|}{0.710} │ \multicolumn{1}{l|}{0.075} │ 0.007 │ \multicolumn{1}{l|}{0.801} │ \multicolumn{1}{l|}{0.110} │ 0.151 │ 1× |
| 2024 | Deterministic baseline | Brier | 0.075 | split: test · folds=4 · epochs=50 · patch-size=128×128 · resolution=128x128 | Sparse Bayesian Networks: Efficient Uncertainty Quantification in Medical Image AnalysisSource quoteL77: Deterministic │ \multicolumn{1}{l|}{0.899} │ \multicolumn{1}{l|}{0.098} │ 0.493 │ \multicolumn{1}{l|}{0.710} │ \multicolumn{1}{l|}{0.075} │ 0.007 │ \multicolumn{1}{l|}{0.801} │ \multicolumn{1}{l|}{0.110} │ 0.151 │ 1× |
| 2024 | MRNet baseline | Dice Score | 0.878 | split: test · resolution=128×128 | Uncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image SegmentationSource quoteL109: \multicolumn{1}{c|}{} │ MRNet \cite{ji2021learning} │ 0.878 │ 0.849 |
| 2024 | Adapter-SAM baseline | Dice Score | 0.861 | split: test · resolution=128×128 | Uncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image SegmentationSource quoteL104: \multicolumn{1}{c|}{} │ Adapter-SAM │ 0.861 │ 0.823 |
| 2023 | UGMCS-Net proposed | DSC | 59.55% | split: val · subset=nodules with U-Net DSC ≤60% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL484: \makecell[l]{UGMCS-Net} │ 70.42 │ 55.5 │ 56.95 │ 41.57 │ 63.17 │ 47.68 │ 46.64 │ 32.52 │ 60.59 │ 44.94 │ 59.55\textcolor{green}{\uparrow5.45} │ 44.44\textcolor{green}{\uparrow5.61} |
| 2023 | UGMCS-Net proposed | DSC | 70.39% | split: val · subset=nodules with U-Net DSC ≤70% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL492: \makecell[l]{UGMCS-Net} │ 74.09 │ 60.02 │ 69.32 │ 54.74 │ 72.02 │ 57.62 │ 65.90 │ 50.99 │ 70.60 │ 56.05 │ 70.39\textcolor{green}{\uparrow5.07} │ 55.88\textcolor{green}{\uparrow5.79} |
| 2023 | UGMCS-Net proposed | DSC | 77.08% | split: val · subset=nodules with U-Net DSC ≤80% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL500: \makecell[l]{UGMCS-Net} │ 79.11 │ 66.21 │ 77.16 │ 63.63 │ 77.27 │ 63.70 │ 74.49 │ 60.64 │ 77.53 │ 64.00 │ 77.08\textcolor{green}{\uparrow1.64} │ 63.64\textcolor{green}{\uparrow2.04} |
| 2023 | VAE U-net (Proposed) proposed non-standard slice | GED | 0.2888 | split: test · subset=cases where all four experts agreed a lung lesion was present | Hierarchical Uncertainty Estimation for Medical Image Segmentation NetworksSource quoteL102: VAE U-net (Proposed) │ 0.2888 │ 0.7087 │ 20.08 M |
| 2023 | VAE U-net (Proposed) proposed non-standard slice | NCC | 0.7087 | split: test · subset=cases where all four experts agreed a lung lesion was present | Hierarchical Uncertainty Estimation for Medical Image Segmentation NetworksSource quoteL102: VAE U-net (Proposed) │ 0.2888 │ 0.7087 │ 20.08 M |
| 2023 | CIMD (Collectively Intelligent Medical Diffusion) proposed | CI | 0.759 | CIMD ablation-study result; the cited table does not specify split or inference samplin… | Ambiguous Medical Image Segmentation Using Diffusion ModelsSource quoteL256: CIMD (Ours) │ 0.321 │ 0.759 │ 0.915 |
| 2023 | CIMD (Collectively Intelligent Medical Diffusion) proposed | D-max | 0.915 | CIMD ablation-study result; the cited table does not specify split or inference samplin… | Ambiguous Medical Image Segmentation Using Diffusion ModelsSource quoteL256: CIMD (Ours) │ 0.321 │ 0.759 │ 0.915 |
| 2023 | Conditional VQ-code diffusion transformer proposed | Density (D) | 1.17 | modality=chest · evaluation-view=2D-MIP | Unaligned 2D to 3D Translation with Conditional Vector-Quantized Code Diffusion using TransformersSource quoteL246: 1.17 │ 0.91 |
| 2023 | P-PII (ours), PHiSeg proposed | Pixel-wise AUROC | 0.66 | split: test | Confidence-Aware and Self-Supervised Image Anomaly LocalisationSource quoteL132: PHiSeg │ 0.76 │ 0.06 │ 0.63 │ 0.93 │ 0.55 │ 0.01 │ 0.55 │ 0.51 │ 0.66 │ 0.01 │ 0.41 │ 0.44 |
| 2023 | Scale-aware super-resolution network with dual affinity learning (proposed method) proposed | average DSC | 75.7% | split: test · implementation=3D | Scale-Aware Super-Resolution Network With Dual Affinity Learning for Lesion Segmentation From Medical ImagesSource quoteL295: On the LIDC-IDRI dataset, our proposed method achieved an average DSC of 75.7% in the testing set, which was 3.1% higher in DSC, 2.9% higher in IOU than Unet, and 0.9% higher in DSC and 0.7% in IOU than DSRL. |
| 2023 | OMBA-UNet proposed | Q-score | 0.7576 | LIDC-IDRI model-comparison evaluation. | Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural NetworksSource quoteL347: OMBA-UNet (ours) │ 0.7576 │ 0.3750 │ 0.2915 │ 0.4701 |
| 2023 | OMBA-UNet proposed | D^2-GED | 0.3750 | LIDC-IDRI model-comparison evaluation. | Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural NetworksSource quoteL347: OMBA-UNet (ours) │ 0.7576 │ 0.3750 │ 0.2915 │ 0.4701 |
| 2023 | OMBA-UNet proposed | Sample Similarity | 0.4701 | LIDC-IDRI model-comparison evaluation. | Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural NetworksSource quoteL347: OMBA-UNet (ours) │ 0.7576 │ 0.3750 │ 0.2915 │ 0.4701 |
| 2023 | PII, PHiSeg | Pixel-wise AUROC | 0.43 | split: test | Confidence-Aware and Self-Supervised Image Anomaly LocalisationSource quoteL129: PHiSeg │ 0.67 │ 0.00 │ 0.51 │ 0.90 │ 0.41 │ 0.01 │ 0.47 │ 0.48 │ 0.43 │ 0.00 │ 0.52 │ 0.50 |
| 2023 | Noisy baseline | MSE | 28.282 | split: test · evaluation=noisy-consensus | MAGI: Multi-Annotated Explanation-Guided LearningSource quoteL408: 28.282 |
| 2023 | Attention U-Net baseline | DSC | 54.10% | split: val · subset=nodules with U-Net DSC ≤60% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL481: \makecell[l]{Attention U-Net} │ 64.30 │ 48.08 │ 58.07 │ 42.36 │ 53.13 │ 36.28 │ 53.28 │ 40.66 │ 41.74 │ 26.78 │ 54.10 │ 38.83 |
| 2023 | Attention U-Net baseline | DSC | 65.32% | split: val · subset=nodules with U-Net DSC ≤70% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL489: \makecell[l]{Attention U-Net} │ 69.44 │ 54.26 │ 63.50 │ 47.93 │ 64.75 │ 48.64 │ 66.27 │ 52.33 │ 62.64 │ 47.28 │ 65.32 │ 50.09 |
| 2023 | Attention U-Net baseline | DSC | 75.44% | split: val · subset=nodules with U-Net DSC ≤80% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL497: \makecell[l]{Attention U-Net} │ 75.55 │ 61.47 │ 74.11 │ 59.89 │ 76.45 │ 62.92 │ 76.02 │ 62.73 │ 75.06 │ 61.01 │ 75.44 │ 61.60 |
| 2023 | PHiSeg (L=5) baseline non-standard slice | GED | 0.3225 | split: test · subset=test subset | Hierarchical Uncertainty Estimation for Medical Image Segmentation NetworksSource quoteL100: PHiSeg (L=5) \cite{PhiSeg2019} │ 0.3225 │ 0.7337 │ 54.37 M |
| 2023 | PHiSeg (L=5) baseline non-standard slice | NCC | 0.7337 | split: test · subset=test subset | Hierarchical Uncertainty Estimation for Medical Image Segmentation NetworksSource quoteL100: PHiSeg (L=5) \cite{PhiSeg2019} │ 0.3225 │ 0.7337 │ 54.37 M |
| 2023 | X2CT-GAN baseline | Density (D) | 0.96 | modality=chest · evaluation-view=2D-MIP | Unaligned 2D to 3D Translation with Conditional Vector-Quantized Code Diffusion using TransformersSource quoteL234: 0.96 │ 0.85 |
| 2023 | PHiSeg (*) baseline | Q-score | 0.7067 | LIDC-IDRI model-comparison evaluation; re-implemented by the authors. | Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural NetworksSource quoteL342: PHiSeg (*) \citep{baumgartner2019phiseg} │ 0.7067 │ 0.3861 │ 0.4021 │ 0.4093 |
| 2023 | PHiSeg (*) baseline | D^2-GED | 0.3861 | LIDC-IDRI model-comparison evaluation; re-implemented by the authors. | Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural NetworksSource quoteL342: PHiSeg (*) \citep{baumgartner2019phiseg} │ 0.7067 │ 0.3861 │ 0.4021 │ 0.4093 |
| 2023 | PHiSeg (*) baseline | Sample Similarity | 0.4093 | LIDC-IDRI model-comparison evaluation; re-implemented by the authors. | Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural NetworksSource quoteL342: PHiSeg (*) \citep{baumgartner2019phiseg} │ 0.7067 │ 0.3861 │ 0.4021 │ 0.4093 |
| 2022 | GIIR (Geometry-Informed Image Reconstruction) proposed | NRMSE | 0.3684 | split: test · views=1 · projection=AP (0°) | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL294: 0.3684 |
| 2022 | GIIR (Geometry-Informed Image Reconstruction) proposed | NRMSE | 0.3000 | split: test · views=2 · projections=AP and lateral (90°) | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL297: 0.3000 |
| 2022 | GIIR (Geometry-Informed Image Reconstruction) proposed | NRMSE | 0.2740 | split: test · views=3 · projection_distribution=evenly distributed over 360° | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL300: 0.2740 |
| 2022 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposed | MAE [HU] | 38.80 HU | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1038: MAE [HU] │ 272.9 │ 38.80 |
| 2022 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposed | SSIM | 0.924 | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1039: SSIM │ 0.362 │ 0.924 |
| 2022 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposed | SNR [dB] | 20.50 dB | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1040: SNR [dB] │ 6.00 │ 20.50 |
| 2022 | C,S,F,ad-CSL proposed | AUC | 96.10% | split: val · 5-fold-cross-validation · delta=0.5 · subset=unsure data · variant=ad-CSL · scenario=12/45 | Faithful learning with sure data for lung nodule diagnosisSource quoteL624: \multicolumn{1}{l}{} │ C,S,F,ad-CSL │ 85.54 │ 96.81 │ 95.85 │ 88.85 │ 91.67 │ 96.10 │ 90.38 |
| 2022 | C,S,F,ad-CSL proposed | F1 | 90.38% | split: val · 5-fold-cross-validation · delta=0.5 · subset=unsure data · variant=ad-CSL · scenario=12/45 | Faithful learning with sure data for lung nodule diagnosisSource quoteL624: \multicolumn{1}{l}{} │ C,S,F,ad-CSL │ 85.54 │ 96.81 │ 95.85 │ 88.85 │ 91.67 │ 96.10 │ 90.38 |
| 2022 | Baseline (without geometric priors) ablation | NRMSE | 0.3961 | split: test · views=1 · projection=AP (0°) | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL264: 0.3961 |
| 2022 | Baseline (without geometric priors) ablation | NRMSE | 0.3927 | split: test · views=2 · projections=AP and lateral (90°) | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL267: 0.3927 |
| 2022 | Baseline (without geometric priors) ablation | NRMSE | 0.3841 | split: test · views=3 · projection_distribution=evenly distributed over 360° | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL270: 0.3841 |
| 2022 | FBP baseline | MAE [HU] | 272.9 HU | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1038: MAE [HU] │ 272.9 │ 38.80 |
| 2022 | FBP baseline | SSIM | 0.362 | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1039: SSIM │ 0.362 │ 0.924 |
| 2022 | FBP baseline | SNR [dB] | 6.00 dB | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1040: SNR [dB] │ 6.00 │ 20.50 |
| 2021 | UAS-Net (Our Method) proposed | Dice | 0.8403 | annotation-target=intersection | Uncertainty-Guided Lung Nodule Segmentation with Feature-Aware AttentionSource quoteL211: Our Method │ 0.8403 |
| 2021 | UAS-Net (Our Method) proposed | Dice | 0.8689 | annotation-target=union | Uncertainty-Guided Lung Nodule Segmentation with Feature-Aware AttentionSource quoteL218: Our Method │ 0.8689 |
| 2021 | RNet proposed | AUC | 95.21 | split: val · 5-fold-cross-validation | Interpretative Computer-aided Lung Cancer Diagnosis: from Radiology Analysis to Malignancy EvaluationSource quoteL191: RNet │ 95.50 │ 89.88 │ 91.01 │ 96.63 │ 95.21 |
| 2021 | R2MNet proposed | AUC | 97.08 | split: val · 5-fold-cross-validation | Interpretative Computer-aided Lung Cancer Diagnosis: from Radiology Analysis to Malignancy EvaluationSource quoteL192: R2MNet │ 96.63 │ 92.13 │ 91.01 │ 97.75 │ 97.08 |
| 2021 | MOW-Net proposed | recall of the unsure class | 0.28 | split: test | Meta ordinal weighting net for improving lung nodule classificationSource quoteL151: In our experiments, we mainly focus on the precision of benign class, recall of malignant and unsure classes~\cite{UDM}. We compared our MOW-Net with the state-of-the-art ordinal regression methods and the normal CE loss. In Table~\ref{tab:results}, we can see that the MOW-Net achieves the best accuracy by a large margin against other methods. Specifically, the MOW-Net significantly improves the recall of the unsure class by 0.28 over the previous best result. This is significant for the clinical diagnosis since a higher recall of the unsure class can encourage more follow-ups and reduce the probabilities of the nodules that are misdiagnosed as malignant or benign. In addition, the precision of benign and the recall of the malignant get a great improvement. |
| 2021 | IG (Bayesian approach to prevalence-bias) proposed non-standard slice | AccHO | 0.86 | folds=3 · prevalence=0.075 · ground_truth=binarized | Bayesian analysis of the prevalence bias: learning and predicting from imbalanced dataSource quoteL717: 0.86 |
| 2021 | IG (Bayesian approach to prevalence-bias) proposed non-standard slice | TNR | 0.82 | folds=3 · prevalence=0.075 · ground_truth=binarized | Bayesian analysis of the prevalence bias: learning and predicting from imbalanced dataSource quoteL718: 0.82 |
| 2021 | IG (Bayesian approach to prevalence-bias) proposed non-standard slice | TPR | 0.89 | folds=3 · prevalence=0.075 · ground_truth=binarized | Bayesian analysis of the prevalence bias: learning and predicting from imbalanced dataSource quoteL719: 0.89 |
| 2021 | IG (Bayesian approach to prevalence-bias) proposed non-standard slice | NPVHO | 0.90 | folds=3 · prevalence=0.075 · ground_truth=binarized | Bayesian analysis of the prevalence bias: learning and predicting from imbalanced dataSource quoteL720: 0.90 |
| 2021 | IG (Bayesian approach to prevalence-bias) proposed non-standard slice | PPVHO | 0.82 | folds=3 · prevalence=0.075 · ground_truth=binarized | Bayesian analysis of the prevalence bias: learning and predicting from imbalanced dataSource quoteL721: 0.82 |
| 2021 | IG (Bayesian approach to prevalence-bias) proposed non-standard slice | AUC | 0.94 | folds=3 · prevalence=0.075 · ground_truth=binarized | Bayesian analysis of the prevalence bias: learning and predicting from imbalanced dataSource quoteL722: 0.94 |
| 2021 | Medical Matting proposed | SAD↓ | 0.0447 | split: val · validation=four-fold-cross-validation · evaluation-region=uncertain-regions-only | Medical Matting: A New Perspective on Medical Segmentation with UncertaintySource quoteL371: Medical Matting (Ours) │ \bf{0.0447} │ \bf{0.0215} │ \bf{0.0607} │ \bf{0.0378} │ \bf{1.0330} │ \bf{0.0093} │ \bf{0.1729} │ \bf{0.4989} │ \bf{0.4023} │ \bf{0.0451} │ \bf{0.5572} │ \bf{0.4255} |
| 2021 | Medical Matting proposed | MSE↓ | 0.0215 | split: val · validation=four-fold-cross-validation · evaluation-region=uncertain-regions-only | Medical Matting: A New Perspective on Medical Segmentation with UncertaintySource quoteL371: Medical Matting (Ours) │ \bf{0.0447} │ \bf{0.0215} │ \bf{0.0607} │ \bf{0.0378} │ \bf{1.0330} │ \bf{0.0093} │ \bf{0.1729} │ \bf{0.4989} │ \bf{0.4023} │ \bf{0.0451} │ \bf{0.5572} │ \bf{0.4255} |
| 2021 | SIB (single Inpainting Block) ablation | Image PSNR | 38.972 | variant=single Inpainting Block · projection-sampling-interval=4 | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quoteL214: SIB │ 38.972 │ 0.941 |
| 2021 | SIB (single Inpainting Block) ablation | Image SSIM | 0.941 | variant=single Inpainting Block · projection-sampling-interval=4 | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quoteL214: SIB │ 38.972 │ 0.941 |
| 2021 | 2D LS-AAE ablation | Image PSNR | 39.472 | convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4 | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quoteL230: 2D LS-AAE │ 39.472 │ 0.944 |
| 2021 | 2D LS-AAE ablation | Image SSIM | 0.944 | convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4 | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quoteL230: 2D LS-AAE │ 39.472 │ 0.944 |
| 2021 | U-Net baseline | Dice | 0.8337 | annotation-target=intersection | Uncertainty-Guided Lung Nodule Segmentation with Feature-Aware AttentionSource quoteL208: U-Net │ 0.8337 |
| 2021 | U-Net baseline | Dice | 0.8611 | annotation-target=union | Uncertainty-Guided Lung Nodule Segmentation with Feature-Aware AttentionSource quoteL215: U-Net │ 0.8611 |
| 2021 | Dual-Branch U-Net baseline | Dice | 0.8698 | annotation-target=union | Uncertainty-Guided Lung Nodule Segmentation with Feature-Aware AttentionSource quoteL216: Dual-Branch U-Net │ 0.8698 |
| 2020 | MCPM (Our MCPM row) proposed | Dice | 84.64 | Dilation-corrupted annotations; r=40% of training images contaminated. Models use the m… | Meta Corrupted Pixels Mining for Medical Image SegmentationSource quoteL185: Our MCPM │ 74.69 │ 84.64 │ 1.7198 │ 75.79 │ 84.99 │ 1.7053 |
| 2020 | MCPM (Our MCPM row) proposed | Dice | 84.99 | ElasticDeform-corrupted annotations; r=40% of training images contaminated. Models use … | Meta Corrupted Pixels Mining for Medical Image SegmentationSource quoteL185: Our MCPM │ 74.69 │ 84.64 │ 1.7198 │ 75.79 │ 84.99 │ 1.7053 |
| 2020 | MWNet | Dice | 81.17 | Dilation-corrupted annotations; r=40% of training images contaminated. Models use the m… | Meta Corrupted Pixels Mining for Medical Image SegmentationSource quoteL184: MWNet │ 71.56 │ 81.17 │ 1.7762 │ 71.89 │ 81.04 │ 1.7680 |
| 2020 | MWNet | Dice | 81.04 | ElasticDeform-corrupted annotations; r=40% of training images contaminated. Models use … | Meta Corrupted Pixels Mining for Medical Image SegmentationSource quoteL184: MWNet │ 71.56 │ 81.17 │ 1.7762 │ 71.89 │ 81.04 │ 1.7680 |
| 2020 | 3D Multi-Scale + RF [28] baseline | malignancy prediction accuracy | 86.84% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL96: 86.84 |
| 2020 | 3D Multi-Crop [29] baseline | malignancy prediction accuracy | 87.14% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL104: 87.14 |
| 2020 | CapsNet [25] baseline | malignancy prediction accuracy | 77.04% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL112: 77.04 |
| 2020 | 3D Dual-Path HSCNN [27] baseline | subtlety (sub) prediction accuracy | 71.9% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL115: 71.9 |
| 2020 | 3D Dual-Path HSCNN [27] baseline | sphericity (sph) prediction accuracy | 55.2% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL116: 55.2 |
| 2019 | Med3D-pretrained 3D-ResNet18 proposed | Accuracy | 88.89% | split: test · fine-tuned · classes=binary · backbone=3D-ResNet18 | Med3D: Transfer Learning for 3D Medical Image AnalysisSource quoteL155: Med3D │ 87.26% │ 88.89% |
| 2019 | SegCaps baseline non-standard slice | 3D Dice-score (median) | 0.9847 | split: test · test-scans=40 · training-scans=180 | LGAN: Lung segmentation in CT scans using generative adversarial networkSource quoteL323: SegCaps \cite{lalonde2018capsules} │ 0.9847 |
| 2019 | Kinetics-pretrained 3D-ResNet18 (Kin) baseline | Accuracy | 82.83% | split: test · fine-tuned · classes=binary · backbone=3D-ResNet18 · pretraining=Kinetics | Med3D: Transfer Learning for 3D Medical Image AnalysisSource quoteL154: Kin~\cite{hara3dcnns} │ 83.21% │ 82.83% |
| 2018 | 3D CNN MTL with Trace norm proposed non-standard slice | Accuracy | 80.08% | split: val · 10-fold-cross-validation · exclusion=nodules with mean malignancy score 3 · cross-validation=10-fold · correctness-tolerance=within ±1 of ground-truth score | Lung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning ApproachesSource quoteL235: 3D CNN MTL with Trace norm │ 80.08 │ 0.626 |
| 2018 | 3D ResNet-152 (Raw + Synthesis) proposed | ACC | 0.9171 | split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patches | Class-Aware Adversarial Lung Nodule Synthesis In CT ImagesSource quoteL137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812 |
| 2018 | 3D ResNet-152 (Raw + Synthesis) proposed | SPE | 0.9774 | split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patches | Class-Aware Adversarial Lung Nodule Synthesis In CT ImagesSource quoteL137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812 |
| 2018 | 3D ResNet-152 (Raw + Synthesis) proposed | AUC | 0.8812 | split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patches | Class-Aware Adversarial Lung Nodule Synthesis In CT ImagesSource quoteL137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812 |
| 2018 | Mean across network architectures (Raw + Synthesis) proposed | AUC | 0.8696 | split: test · backbone=mean across four 3D CNN architectures · training-data=original patches + 463 synthesized malignant patches | Class-Aware Adversarial Lung Nodule Synthesis In CT ImagesSource quoteL139: Mean │ 0.8821 │ 0.6353 │ 0.9266 │ 0.8696 |
| 2018 | GA-SSD proposed | CPM | 0.863 | Authors report a CPM comparison on the LIDC-IDRI dataset against Wang18. | Group-Attention Single-Shot Detector (GA-SSD): Finding Pulmonary Nodules in Large-Scale CT ImagesSource quoteL111: To better justify the effectiveness of the proposed method, we conduct experiments over the LIDC-IDRI dataset \cite{armato2011lung} and obtained the competitive result with the state-of-the-art (Wang18 \cite{inbook}) method (CPM scores: 0.863 vs 0.878). |
| 2018 | Wang18 baseline | CPM | 0.878 | Authors report a CPM comparison on the LIDC-IDRI dataset against GA-SSD. | Group-Attention Single-Shot Detector (GA-SSD): Finding Pulmonary Nodules in Large-Scale CT ImagesSource quoteL111: To better justify the effectiveness of the proposed method, we conduct experiments over the LIDC-IDRI dataset \cite{armato2011lung} and obtained the competitive result with the state-of-the-art (Wang18 \cite{inbook}) method (CPM scores: 0.863 vs 0.878). |
| 2017 | End-to-end detector (proposed) proposed | Mean FROC score | 0.608 | noise=noiseless · projections-per-rotation=144 | End-to-End Abnormality Detection in Medical ImagingSource quoteL110: 0.608 |
| 2017 | End-to-end detector (proposed) proposed | Mean FROC score | 0.615 | noise-level-N0=1 × 10^5 · projections-per-rotation=144 | End-to-End Abnormality Detection in Medical ImagingSource quoteL115: 0.615 |