LIDC-IDRI
51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | 2D LS-AAE SOTA frontier (+1 variant) | 0.944 | 2021-01-01 | convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4 · Ablation study with projection-sampling interval 4 (the ablation default); 2D convolu… | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quote2D LS-AAE │ 39.472 │ 0.944 |
| 2 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) | 0.924 | 2022-01-01 | resolution=256×256 · projections=40 · Evaluation on patient datasets unseen during training and validation; images downsamp… | CNN-based regularisation for CT image reconstructionsSource quoteSSIM │ 0.362 │ 0.924 |
| 3 | OW-CNFs | 0.819 | 2024-10-01 | I0=1×10^4 · Average on the LIDC-IDRI test set (30 images); simulated low-dose projections at I0=1… | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteOW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 4 | DVG-Diffusion (+3 variants) | 0.679 | 2025-03-01 | Ablation result; biplanar X-ray inputs; evaluated on the 102-volume test split. | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteDVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35 |
Showing 30 of 30 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | DiffOSeg proposed | GED_10 (Generalized Energy Distance) | 0.0915 | split: val · samples=10 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | DiffOSeg proposed | GED_30 (Generalized Energy Distance) | 0.0773 | split: val · samples=30 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | DiffOSeg proposed | GED_50 (Generalized Energy Distance) | 0.0745 | split: val · samples=50 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | second-best method baseline | GED_10 (Generalized Energy Distance) | 0.1461 | split: val · samples=10 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | second-best method baseline | GED_30 (Generalized Energy Distance) | 0.1375 | split: val · samples=30 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2025 | second-best method baseline | GED_50 (Generalized Energy Distance) | 0.1358 | split: val · samples=50 · evaluation=4-fold-cross-validation | DiffOSeg: Omni Medical Image Segmentation via Multi-Expert Collaboration Diffusion ModelSource quoteL119: As shown in Table~\ref{tab:diversity_performance}, on LIDC-IDRI (4-fold cross-validation average), DiffOSeg achieves superior improvements in GED metrics across all sample sizes (10/30/50), outperforming the second-best method by 37.4% for GED-10 (0.0915 vs. 0.1461), 43.8% for GED-30 (0.0773 vs. 0.1375), and 45.2% for GED-50 (0.0745 vs. 0.1358). |
| 2024 | Lung nodule detection model non-standard slice | AP@IoU=0.5 | 65.63 | split: val · subset=201 CTs; 399 solid nodules | EXACT-Net: EHR-guided lung tumor auto-segmentation for non-small cell lung cancer radiotherapySource quoteL189: Lung Nodule │ 65.63 │ 59.15 |
| 2024 | Lung nodule detection model non-standard slice | AP@IoU=0.7 | 59.15 | split: val · subset=201 CTs; 399 solid nodules | EXACT-Net: EHR-guided lung tumor auto-segmentation for non-small cell lung cancer radiotherapySource quoteL189: Lung Nodule │ 65.63 │ 59.15 |
| 2024 | D-Persona (Stage I, #50) | GED ↓ | 0.1358 | split: val | Diversified and personalized multi-rater medical image segmentationSource quoteL215: D-Persona (Stage \uppercase\expandafter{\romannumeral1}, \#50) │ 0.1358 │ 90.45 │ 91.37 │ 91.33 │ CM-Global \cite{tanno2019learning} │ 0.2432 │ 88.53 │ 87.51 │ 87.51 │ 86.13 │ 88.76 │ 88.99 │ 86.18 │ 87.51 |
| 2023 | UGMCS-Net proposed | DSC | 59.55% | split: val · subset=nodules with U-Net DSC ≤60% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL484: \makecell[l]{UGMCS-Net} │ 70.42 │ 55.5 │ 56.95 │ 41.57 │ 63.17 │ 47.68 │ 46.64 │ 32.52 │ 60.59 │ 44.94 │ 59.55\textcolor{green}{\uparrow5.45} │ 44.44\textcolor{green}{\uparrow5.61} |
| 2023 | UGMCS-Net proposed | DSC | 70.39% | split: val · subset=nodules with U-Net DSC ≤70% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL492: \makecell[l]{UGMCS-Net} │ 74.09 │ 60.02 │ 69.32 │ 54.74 │ 72.02 │ 57.62 │ 65.90 │ 50.99 │ 70.60 │ 56.05 │ 70.39\textcolor{green}{\uparrow5.07} │ 55.88\textcolor{green}{\uparrow5.79} |
| 2023 | UGMCS-Net proposed | DSC | 77.08% | split: val · subset=nodules with U-Net DSC ≤80% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL500: \makecell[l]{UGMCS-Net} │ 79.11 │ 66.21 │ 77.16 │ 63.63 │ 77.27 │ 63.70 │ 74.49 │ 60.64 │ 77.53 │ 64.00 │ 77.08\textcolor{green}{\uparrow1.64} │ 63.64\textcolor{green}{\uparrow2.04} |
| 2023 | Attention U-Net baseline | DSC | 54.10% | split: val · subset=nodules with U-Net DSC ≤60% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL481: \makecell[l]{Attention U-Net} │ 64.30 │ 48.08 │ 58.07 │ 42.36 │ 53.13 │ 36.28 │ 53.28 │ 40.66 │ 41.74 │ 26.78 │ 54.10 │ 38.83 |
| 2023 | Attention U-Net baseline | DSC | 65.32% | split: val · subset=nodules with U-Net DSC ≤70% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL489: \makecell[l]{Attention U-Net} │ 69.44 │ 54.26 │ 63.50 │ 47.93 │ 64.75 │ 48.64 │ 66.27 │ 52.33 │ 62.64 │ 47.28 │ 65.32 │ 50.09 |
| 2023 | Attention U-Net baseline | DSC | 75.44% | split: val · subset=nodules with U-Net DSC ≤80% | Lung Nodule Segmentation and Uncertain Region Prediction With an Uncertainty-Aware Attention MechanismSource quoteL497: \makecell[l]{Attention U-Net} │ 75.55 │ 61.47 │ 74.11 │ 59.89 │ 76.45 │ 62.92 │ 76.02 │ 62.73 │ 75.06 │ 61.01 │ 75.44 │ 61.60 |
| 2022 | C,S,F,ad-CSL proposed | AUC | 96.10% | split: val · 5-fold-cross-validation · delta=0.5 · subset=unsure data · variant=ad-CSL · scenario=12/45 | Faithful learning with sure data for lung nodule diagnosisSource quoteL624: \multicolumn{1}{l}{} │ C,S,F,ad-CSL │ 85.54 │ 96.81 │ 95.85 │ 88.85 │ 91.67 │ 96.10 │ 90.38 |
| 2022 | C,S,F,ad-CSL proposed | F1 | 90.38% | split: val · 5-fold-cross-validation · delta=0.5 · subset=unsure data · variant=ad-CSL · scenario=12/45 | Faithful learning with sure data for lung nodule diagnosisSource quoteL624: \multicolumn{1}{l}{} │ C,S,F,ad-CSL │ 85.54 │ 96.81 │ 95.85 │ 88.85 │ 91.67 │ 96.10 │ 90.38 |
| 2021 | RNet proposed | AUC | 95.21 | split: val · 5-fold-cross-validation | Interpretative Computer-aided Lung Cancer Diagnosis: from Radiology Analysis to Malignancy EvaluationSource quoteL191: RNet │ 95.50 │ 89.88 │ 91.01 │ 96.63 │ 95.21 |
| 2021 | R2MNet proposed | AUC | 97.08 | split: val · 5-fold-cross-validation | Interpretative Computer-aided Lung Cancer Diagnosis: from Radiology Analysis to Malignancy EvaluationSource quoteL192: R2MNet │ 96.63 │ 92.13 │ 91.01 │ 97.75 │ 97.08 |
| 2021 | Medical Matting proposed | SAD↓ | 0.0447 | split: val · validation=four-fold-cross-validation · evaluation-region=uncertain-regions-only | Medical Matting: A New Perspective on Medical Segmentation with UncertaintySource quoteL371: Medical Matting (Ours) │ \bf{0.0447} │ \bf{0.0215} │ \bf{0.0607} │ \bf{0.0378} │ \bf{1.0330} │ \bf{0.0093} │ \bf{0.1729} │ \bf{0.4989} │ \bf{0.4023} │ \bf{0.0451} │ \bf{0.5572} │ \bf{0.4255} |
| 2021 | Medical Matting proposed | MSE↓ | 0.0215 | split: val · validation=four-fold-cross-validation · evaluation-region=uncertain-regions-only | Medical Matting: A New Perspective on Medical Segmentation with UncertaintySource quoteL371: Medical Matting (Ours) │ \bf{0.0447} │ \bf{0.0215} │ \bf{0.0607} │ \bf{0.0378} │ \bf{1.0330} │ \bf{0.0093} │ \bf{0.1729} │ \bf{0.4989} │ \bf{0.4023} │ \bf{0.0451} │ \bf{0.5572} │ \bf{0.4255} |
| 2020 | 3D Multi-Scale + RF [28] baseline | malignancy prediction accuracy | 86.84% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL96: 86.84 |
| 2020 | 3D Multi-Crop [29] baseline | malignancy prediction accuracy | 87.14% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL104: 87.14 |
| 2020 | CapsNet [25] baseline | malignancy prediction accuracy | 77.04% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL112: 77.04 |
| 2020 | 3D Dual-Path HSCNN [27] baseline | subtlety (sub) prediction accuracy | 71.9% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL115: 71.9 |
| 2020 | 3D Dual-Path HSCNN [27] baseline | sphericity (sph) prediction accuracy | 55.2% | split: val | Encoding Visual Attributes in Capsules for Explainable Medical DiagnosesSource quoteL116: 55.2 |
| 2018 | 3D CNN MTL with Trace norm proposed non-standard slice | Accuracy | 80.08% | split: val · 10-fold-cross-validation · exclusion=nodules with mean malignancy score 3 · cross-validation=10-fold · correctness-tolerance=within ±1 of ground-truth score | Lung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning ApproachesSource quoteL235: 3D CNN MTL with Trace norm │ 80.08 │ 0.626 |
| 2015 | Discovery radiomics framework proposed | average accuracy | 77.52% | split: val · subset=pathologically-proven data from 97 patients · evaluation=10-fold cross-validation | Discovery Radiomics for Pathologically-Proven Computed Tomography Lung Cancer PredictionSource quoteL8: Lung cancer is the leading cause for cancer related deaths. As such, there is an urgent need for a streamlined process that can allow radiologists to provide diagnosis with greater efficiency and accuracy. A powerful tool to do this is radiomics: a high-dimension imaging feature set. In this study, we take the idea of radiomics one step further by introducing the concept of discovery radiomics for lung cancer prediction using CT imaging data. In this study, we realize these custom radiomic sequencers as deep convolutional sequencers using a deep convolutional neural network learning architecture. To illustrate the prognostic power and effectiveness of the radiomic sequences produced by the discovered sequencer, we perform cancer prediction between malignant and benign lesions from 97 patients using the pathologically-proven diagnostic data from the LIDC-IDRI dataset. Using the clinically provided pathologically-proven data as ground truth, the proposed framework provided an average accuracy of 77.52% via 10-fold cross-validation with a sensitivity of 79.06% and specificity of 76.11%, surpassing the state-of-the art method. |
| 2015 | Discovery radiomics framework proposed | sensitivity | 79.06% | split: val · subset=pathologically-proven data from 97 patients · evaluation=10-fold cross-validation | Discovery Radiomics for Pathologically-Proven Computed Tomography Lung Cancer PredictionSource quoteL8: Lung cancer is the leading cause for cancer related deaths. As such, there is an urgent need for a streamlined process that can allow radiologists to provide diagnosis with greater efficiency and accuracy. A powerful tool to do this is radiomics: a high-dimension imaging feature set. In this study, we take the idea of radiomics one step further by introducing the concept of discovery radiomics for lung cancer prediction using CT imaging data. In this study, we realize these custom radiomic sequencers as deep convolutional sequencers using a deep convolutional neural network learning architecture. To illustrate the prognostic power and effectiveness of the radiomic sequences produced by the discovered sequencer, we perform cancer prediction between malignant and benign lesions from 97 patients using the pathologically-proven diagnostic data from the LIDC-IDRI dataset. Using the clinically provided pathologically-proven data as ground truth, the proposed framework provided an average accuracy of 77.52% via 10-fold cross-validation with a sensitivity of 79.06% and specificity of 76.11%, surpassing the state-of-the art method. |
| 2015 | Discovery radiomics framework proposed | specificity | 76.11% | split: val · subset=pathologically-proven data from 97 patients · evaluation=10-fold cross-validation | Discovery Radiomics for Pathologically-Proven Computed Tomography Lung Cancer PredictionSource quoteL8: Lung cancer is the leading cause for cancer related deaths. As such, there is an urgent need for a streamlined process that can allow radiologists to provide diagnosis with greater efficiency and accuracy. A powerful tool to do this is radiomics: a high-dimension imaging feature set. In this study, we take the idea of radiomics one step further by introducing the concept of discovery radiomics for lung cancer prediction using CT imaging data. In this study, we realize these custom radiomic sequencers as deep convolutional sequencers using a deep convolutional neural network learning architecture. To illustrate the prognostic power and effectiveness of the radiomic sequences produced by the discovered sequencer, we perform cancer prediction between malignant and benign lesions from 97 patients using the pathologically-proven diagnostic data from the LIDC-IDRI dataset. Using the clinically provided pathologically-proven data as ground truth, the proposed framework provided an average accuracy of 77.52% via 10-fold cross-validation with a sensitivity of 79.06% and specificity of 76.11%, surpassing the state-of-the art method. |