LIDC-IDRI
51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | 2D LS-AAE SOTA frontier (+1 variant) | 0.944 | 2021-01-01 | convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4 · Ablation study with projection-sampling interval 4 (the ablation default); 2D convolu… | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quote2D LS-AAE │ 39.472 │ 0.944 |
| 2 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) | 0.924 | 2022-01-01 | resolution=256×256 · projections=40 · Evaluation on patient datasets unseen during training and validation; images downsamp… | CNN-based regularisation for CT image reconstructionsSource quoteSSIM │ 0.362 │ 0.924 |
| 3 | OW-CNFs | 0.819 | 2024-10-01 | I0=1×10^4 · Average on the LIDC-IDRI test set (30 images); simulated low-dose projections at I0=1… | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteOW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 4 | DVG-Diffusion (+3 variants) | 0.679 | 2025-03-01 | Ablation result; biplanar X-ray inputs; evaluated on the 102-volume test split. | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteDVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35 |
Showing 53 of 53 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Harmonizer Network (Harmonizer, ours) proposed | DSC | 84.27 | split: test | Harmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical SegmentationSource quoteL416: 89.37 │ 1.44 │ 87.92 │ 2.88 │ 84.27 │ 6.53 |
| 2026 | D-Persona | DSC | 71.11 | split: test | Harmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical SegmentationSource quoteL411: 85.74 │ 3.43 │ 81.80 │ 7.37 │ 71.11 │ 18.06 |
| 2026 | Harmonizer Network | DSC | 85.30 | split: test | Harmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical SegmentationSource quoteL616: 85.30 │ 5.48 |
| 2026 | D-Persona | DSC | 83.02 | split: test | Harmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical SegmentationSource quoteL613: 83.02 │ 6.15 |
| 2025 | DVG-Diffusion (90° synthesized view) proposed | PSNR | 22.54 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL273: PSNR \uparrow │ 22.29 │ 22.46 │ 22.47 │ 22.43 │ 22.48 │ 22.54 │ 22.47 |
| 2025 | DVG-Diffusion (90° synthesized view) proposed | SSIM | 0.541 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537 |
| 2025 | DVG-Diffusion ablation | SSIM | 0.679 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL228: DVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35 |
| 2025 | VPGE-Diffusion ablation | SSIM | 0.667 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL227: \checkmark │ 26.47 │ 0.667 │ 28.11 |
| 2025 | DVG-Diffusion (without new-view input) ablation | PSNR | 22.29 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL273: PSNR \uparrow │ 22.29 │ 22.46 │ 22.47 │ 22.43 │ 22.48 │ 22.54 │ 22.47 |
| 2025 | DVG-Diffusion (without new-view input) ablation | SSIM | 0.532 | split: test | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteL275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537 |
| 2025 | SSB++ | GED | 0.208 | split: test | Ambiguous Medical Image Segmentation Using Diffusion Schrödinger BridgeSource quoteL160: SSB++ (Ours) │ 50 │ \bf 0.208 |
| 2024 | OSEM-CPNN proposed | PSNR | 36.49 dB | split: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50 | A Low-dose CT Reconstruction Network Based on TV-regularized OSEM AlgorithmSource quoteL374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M |
| 2024 | OSEM-CPNN proposed | SSIM | 0.950 | split: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50 | A Low-dose CT Reconstruction Network Based on TV-regularized OSEM AlgorithmSource quoteL374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M |
| 2024 | UA-SAM (Uncertainty-aware Adapter) proposed | Dice Score | 0.887 | split: test · prompt=single-point · samples=4 · backbone=SAM ViT-B · resolution=128×128 · aggregation=majority-vote | Uncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image SegmentationSource quoteL110: \multicolumn{1}{c|}{} │ UA-SAM(ours) │ 0.887 │ 0.856 |
| 2024 | OW-CNFs proposed | PSNR | 33.14 dB | split: test · I0=1×10^4 | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteL272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 2024 | OW-CNFs proposed | SSIM | 0.819 | split: test · I0=1×10^4 | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteL272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 2024 | SCA-VNet baseline | DSC | 87.50% | split: test | Medical artificial intelligence for early detection of lung cancer: A surveySource quoteL296: Liu et al. {\cite{liu2024multiscale}} │ 2024 │ LIDC-IDRI │ SCA-VNet │ Residual edge enhancement │ PyTorch 1.12.1 │ DSC: 87.50% ; Sensitivity: 86.80% ; Precision: 88.32% |
| 2024 | Deterministic baseline | Dice | 0.710 | split: test · folds=4 · epochs=50 · patch-size=128×128 · resolution=128x128 | Sparse Bayesian Networks: Efficient Uncertainty Quantification in Medical Image AnalysisSource quoteL77: Deterministic │ \multicolumn{1}{l|}{0.899} │ \multicolumn{1}{l|}{0.098} │ 0.493 │ \multicolumn{1}{l|}{0.710} │ \multicolumn{1}{l|}{0.075} │ 0.007 │ \multicolumn{1}{l|}{0.801} │ \multicolumn{1}{l|}{0.110} │ 0.151 │ 1× |
| 2024 | Deterministic baseline | Brier | 0.075 | split: test · folds=4 · epochs=50 · patch-size=128×128 · resolution=128x128 | Sparse Bayesian Networks: Efficient Uncertainty Quantification in Medical Image AnalysisSource quoteL77: Deterministic │ \multicolumn{1}{l|}{0.899} │ \multicolumn{1}{l|}{0.098} │ 0.493 │ \multicolumn{1}{l|}{0.710} │ \multicolumn{1}{l|}{0.075} │ 0.007 │ \multicolumn{1}{l|}{0.801} │ \multicolumn{1}{l|}{0.110} │ 0.151 │ 1× |
| 2024 | MRNet baseline | Dice Score | 0.878 | split: test · resolution=128×128 | Uncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image SegmentationSource quoteL109: \multicolumn{1}{c|}{} │ MRNet \cite{ji2021learning} │ 0.878 │ 0.849 |
| 2024 | Adapter-SAM baseline | Dice Score | 0.861 | split: test · resolution=128×128 | Uncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image SegmentationSource quoteL104: \multicolumn{1}{c|}{} │ Adapter-SAM │ 0.861 │ 0.823 |
| 2023 | VAE U-net (Proposed) proposed non-standard slice | GED | 0.2888 | split: test · subset=cases where all four experts agreed a lung lesion was present | Hierarchical Uncertainty Estimation for Medical Image Segmentation NetworksSource quoteL102: VAE U-net (Proposed) │ 0.2888 │ 0.7087 │ 20.08 M |
| 2023 | VAE U-net (Proposed) proposed non-standard slice | NCC | 0.7087 | split: test · subset=cases where all four experts agreed a lung lesion was present | Hierarchical Uncertainty Estimation for Medical Image Segmentation NetworksSource quoteL102: VAE U-net (Proposed) │ 0.2888 │ 0.7087 │ 20.08 M |
| 2023 | P-PII (ours), PHiSeg proposed | Pixel-wise AUROC | 0.66 | split: test | Confidence-Aware and Self-Supervised Image Anomaly LocalisationSource quoteL132: PHiSeg │ 0.76 │ 0.06 │ 0.63 │ 0.93 │ 0.55 │ 0.01 │ 0.55 │ 0.51 │ 0.66 │ 0.01 │ 0.41 │ 0.44 |
| 2023 | Scale-aware super-resolution network with dual affinity learning (proposed method) proposed | average DSC | 75.7% | split: test · implementation=3D | Scale-Aware Super-Resolution Network With Dual Affinity Learning for Lesion Segmentation From Medical ImagesSource quoteL295: On the LIDC-IDRI dataset, our proposed method achieved an average DSC of 75.7% in the testing set, which was 3.1% higher in DSC, 2.9% higher in IOU than Unet, and 0.9% higher in DSC and 0.7% in IOU than DSRL. |
| 2023 | PII, PHiSeg | Pixel-wise AUROC | 0.43 | split: test | Confidence-Aware and Self-Supervised Image Anomaly LocalisationSource quoteL129: PHiSeg │ 0.67 │ 0.00 │ 0.51 │ 0.90 │ 0.41 │ 0.01 │ 0.47 │ 0.48 │ 0.43 │ 0.00 │ 0.52 │ 0.50 |
| 2023 | Noisy baseline | MSE | 28.282 | split: test · evaluation=noisy-consensus | MAGI: Multi-Annotated Explanation-Guided LearningSource quoteL408: 28.282 |
| 2023 | PHiSeg (L=5) baseline non-standard slice | GED | 0.3225 | split: test · subset=test subset | Hierarchical Uncertainty Estimation for Medical Image Segmentation NetworksSource quoteL100: PHiSeg (L=5) \cite{PhiSeg2019} │ 0.3225 │ 0.7337 │ 54.37 M |
| 2023 | PHiSeg (L=5) baseline non-standard slice | NCC | 0.7337 | split: test · subset=test subset | Hierarchical Uncertainty Estimation for Medical Image Segmentation NetworksSource quoteL100: PHiSeg (L=5) \cite{PhiSeg2019} │ 0.3225 │ 0.7337 │ 54.37 M |
| 2022 | GIIR (Geometry-Informed Image Reconstruction) proposed | NRMSE | 0.3684 | split: test · views=1 · projection=AP (0°) | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL294: 0.3684 |
| 2022 | GIIR (Geometry-Informed Image Reconstruction) proposed | NRMSE | 0.3000 | split: test · views=2 · projections=AP and lateral (90°) | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL297: 0.3000 |
| 2022 | GIIR (Geometry-Informed Image Reconstruction) proposed | NRMSE | 0.2740 | split: test · views=3 · projection_distribution=evenly distributed over 360° | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL300: 0.2740 |
| 2022 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposed | MAE [HU] | 38.80 HU | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1038: MAE [HU] │ 272.9 │ 38.80 |
| 2022 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposed | SSIM | 0.924 | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1039: SSIM │ 0.362 │ 0.924 |
| 2022 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposed | SNR [dB] | 20.50 dB | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1040: SNR [dB] │ 6.00 │ 20.50 |
| 2022 | Baseline (without geometric priors) ablation | NRMSE | 0.3961 | split: test · views=1 · projection=AP (0°) | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL264: 0.3961 |
| 2022 | Baseline (without geometric priors) ablation | NRMSE | 0.3927 | split: test · views=2 · projections=AP and lateral (90°) | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL267: 0.3927 |
| 2022 | Baseline (without geometric priors) ablation | NRMSE | 0.3841 | split: test · views=3 · projection_distribution=evenly distributed over 360° | A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstructionSource quoteL270: 0.3841 |
| 2022 | FBP baseline | MAE [HU] | 272.9 HU | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1038: MAE [HU] │ 272.9 │ 38.80 |
| 2022 | FBP baseline | SSIM | 0.362 | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1039: SSIM │ 0.362 │ 0.924 |
| 2022 | FBP baseline | SNR [dB] | 6.00 dB | split: test · resolution=256×256 · projections=40 | CNN-based regularisation for CT image reconstructionsSource quoteL1040: SNR [dB] │ 6.00 │ 20.50 |
| 2021 | MOW-Net proposed | recall of the unsure class | 0.28 | split: test | Meta ordinal weighting net for improving lung nodule classificationSource quoteL151: In our experiments, we mainly focus on the precision of benign class, recall of malignant and unsure classes~\cite{UDM}. We compared our MOW-Net with the state-of-the-art ordinal regression methods and the normal CE loss. In Table~\ref{tab:results}, we can see that the MOW-Net achieves the best accuracy by a large margin against other methods. Specifically, the MOW-Net significantly improves the recall of the unsure class by 0.28 over the previous best result. This is significant for the clinical diagnosis since a higher recall of the unsure class can encourage more follow-ups and reduce the probabilities of the nodules that are misdiagnosed as malignant or benign. In addition, the precision of benign and the recall of the malignant get a great improvement. |
| 2019 | Med3D-pretrained 3D-ResNet18 proposed | Accuracy | 88.89% | split: test · fine-tuned · classes=binary · backbone=3D-ResNet18 | Med3D: Transfer Learning for 3D Medical Image AnalysisSource quoteL155: Med3D │ 87.26% │ 88.89% |
| 2019 | SegCaps baseline non-standard slice | 3D Dice-score (median) | 0.9847 | split: test · test-scans=40 · training-scans=180 | LGAN: Lung segmentation in CT scans using generative adversarial networkSource quoteL323: SegCaps \cite{lalonde2018capsules} │ 0.9847 |
| 2019 | Kinetics-pretrained 3D-ResNet18 (Kin) baseline | Accuracy | 82.83% | split: test · fine-tuned · classes=binary · backbone=3D-ResNet18 · pretraining=Kinetics | Med3D: Transfer Learning for 3D Medical Image AnalysisSource quoteL154: Kin~\cite{hara3dcnns} │ 83.21% │ 82.83% |
| 2018 | 3D ResNet-152 (Raw + Synthesis) proposed | ACC | 0.9171 | split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patches | Class-Aware Adversarial Lung Nodule Synthesis In CT ImagesSource quoteL137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812 |
| 2018 | 3D ResNet-152 (Raw + Synthesis) proposed | SPE | 0.9774 | split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patches | Class-Aware Adversarial Lung Nodule Synthesis In CT ImagesSource quoteL137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812 |
| 2018 | 3D ResNet-152 (Raw + Synthesis) proposed | AUC | 0.8812 | split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patches | Class-Aware Adversarial Lung Nodule Synthesis In CT ImagesSource quoteL137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812 |
| 2018 | Mean across network architectures (Raw + Synthesis) proposed | AUC | 0.8696 | split: test · backbone=mean across four 3D CNN architectures · training-data=original patches + 463 synthesized malignant patches | Class-Aware Adversarial Lung Nodule Synthesis In CT ImagesSource quoteL139: Mean │ 0.8821 │ 0.6353 │ 0.9266 │ 0.8696 |
| 2016 | ReCTnet proposed | Sensitivity | 90.5% | split: test · test-scans=150 · training-scans=600 · operating-point=4.5 FPs/scan (p=0.75) · target-criterion=confirmed by all 4 radiologists | Recurrent Convolutional Networks for Pulmonary Nodule Detection in CT ImagingSource quoteL158: ReCTnet │ {\bf 90.5} % │ {\bf 4.5} │ 600 │ 150 |
| 2016 | ReCTnet proposed | False positives per scan | 4.5 FPs/scan | split: test · test-scans=150 · training-scans=600 · operating-point=paired with 90.5% sensitivity (p=0.75) · target-criterion=confirmed by all 4 radiologists | Recurrent Convolutional Networks for Pulmonary Nodule Detection in CT ImagingSource quoteL158: ReCTnet │ {\bf 90.5} % │ {\bf 4.5} │ 600 │ 150 |
| 2016 | Competing multi-channel CNN baseline | Sensitivity | 81.8% | split: test · method=competing multi-channel CNN · test-scans=150 · training-scans=600 · operating-point=paired with 6.8 FPs/scan · target-criterion=confirmed by all 4 radiologists | Recurrent Convolutional Networks for Pulmonary Nodule Detection in CT ImagingSource quoteL160: CNNs │ 81.8% │ 6.8 │ 600 │ 150 |
| 2016 | Competing multi-channel CNN baseline | False positives per scan | 6.8 FPs/scan | split: test · method=competing multi-channel CNN · test-scans=150 · training-scans=600 · operating-point=paired with 81.8% sensitivity · target-criterion=confirmed by all 4 radiologists | Recurrent Convolutional Networks for Pulmonary Nodule Detection in CT ImagingSource quoteL160: CNNs │ 81.8% │ 6.8 │ 600 │ 150 |