LIDC-IDRI

51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.50.70.81.0202120232025SIB (single Inpainting Block): 0.941 (2021)2D LS-AAE: 0.944 (2021)MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet): 0.924 (2022)OW-CNFs: 0.819 (2024)DVG-Diffusion (without new-view input): 0.532 (2025)DVG-Diffusion (90° synthesized view): 0.541 (2025)VPGE-Diffusion: 0.667 (2025)DVG-Diffusion: 0.679 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 26 of 26 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Harmonizer Network (Harmonizer, ours) proposedDSC84.27split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L416: 89.37 │ 1.44 │ 87.92 │ 2.88 │ 84.27 │ 6.53
2025DVG-Diffusion (90° synthesized view) proposedPSNR22.54split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L273: PSNR \uparrow │ 22.29 │ 22.46 │ 22.47 │ 22.43 │ 22.48 │ 22.54 │ 22.47
2025DVG-Diffusion (90° synthesized view) proposedSSIM0.541split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537
2024OSEM-CPNN proposedPSNR36.49 dBsplit: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50A Low-dose CT Reconstruction Network Based on TV-regularized OSEM Algorithm
Source quote
L374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M
2024OSEM-CPNN proposedSSIM0.950split: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50A Low-dose CT Reconstruction Network Based on TV-regularized OSEM Algorithm
Source quote
L374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M
2024UA-SAM (Uncertainty-aware Adapter) proposedDice Score0.887split: test · prompt=single-point · samples=4 · backbone=SAM ViT-B · resolution=128×128 · aggregation=majority-voteUncertainty-Aware Adapter: Adapting Segment Anything Model (SAM) for Ambiguous Medical Image Segmentation
Source quote
L110: \multicolumn{1}{c|}{} │ UA-SAM(ours) │ 0.887 │ 0.856
2024OW-CNFs proposedPSNR33.14 dBsplit: test · I0=1×10^4Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing Flows
Source quote
L272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819
2024OW-CNFs proposedSSIM0.819split: test · I0=1×10^4Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing Flows
Source quote
L272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819
2023VAE U-net (Proposed) proposed non-standard sliceGED0.2888split: test · subset=cases where all four experts agreed a lung lesion was presentHierarchical Uncertainty Estimation for Medical Image Segmentation Networks
Source quote
L102: VAE U-net (Proposed) │ 0.2888 │ 0.7087 │ 20.08 M
2023VAE U-net (Proposed) proposed non-standard sliceNCC0.7087split: test · subset=cases where all four experts agreed a lung lesion was presentHierarchical Uncertainty Estimation for Medical Image Segmentation Networks
Source quote
L102: VAE U-net (Proposed) │ 0.2888 │ 0.7087 │ 20.08 M
2023P-PII (ours), PHiSeg proposedPixel-wise AUROC0.66split: testConfidence-Aware and Self-Supervised Image Anomaly Localisation
Source quote
L132: PHiSeg │ 0.76 │ 0.06 │ 0.63 │ 0.93 │ 0.55 │ 0.01 │ 0.55 │ 0.51 │ 0.66 │ 0.01 │ 0.41 │ 0.44
2023Scale-aware super-resolution network with dual affinity learning (proposed method) proposedaverage DSC75.7%split: test · implementation=3DScale-Aware Super-Resolution Network With Dual Affinity Learning for Lesion Segmentation From Medical Images
Source quote
L295: On the LIDC-IDRI dataset, our proposed method achieved an average DSC of 75.7% in the testing set, which was 3.1% higher in DSC, 2.9% higher in IOU than Unet, and 0.9% higher in DSC and 0.7% in IOU than DSRL.
2022GIIR (Geometry-Informed Image Reconstruction) proposedNRMSE0.3684split: test · views=1 · projection=AP (0°)A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L294: 0.3684
2022GIIR (Geometry-Informed Image Reconstruction) proposedNRMSE0.3000split: test · views=2 · projections=AP and lateral (90°)A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L297: 0.3000
2022GIIR (Geometry-Informed Image Reconstruction) proposedNRMSE0.2740split: test · views=3 · projection_distribution=evenly distributed over 360°A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Source quote
L300: 0.2740
2022MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposedMAE [HU]38.80 HUsplit: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1038: MAE [HU] │ 272.9 │ 38.80
2022MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposedSSIM0.924split: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1039: SSIM │ 0.362 │ 0.924
2022MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposedSNR [dB]20.50 dBsplit: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1040: SNR [dB] │ 6.00 │ 20.50
2021MOW-Net proposedrecall of the unsure class0.28split: testMeta ordinal weighting net for improving lung nodule classification
Source quote
L151: In our experiments, we mainly focus on the precision of benign class, recall of malignant and unsure classes~\cite{UDM}. We compared our MOW-Net with the state-of-the-art ordinal regression methods and the normal CE loss. In Table~\ref{tab:results}, we can see that the MOW-Net achieves the best accuracy by a large margin against other methods. Specifically, the MOW-Net significantly improves the recall of the unsure class by 0.28 over the previous best result. This is significant for the clinical diagnosis since a higher recall of the unsure class can encourage more follow-ups and reduce the probabilities of the nodules that are misdiagnosed as malignant or benign. In addition, the precision of benign and the recall of the malignant get a great improvement.
2019Med3D-pretrained 3D-ResNet18 proposedAccuracy88.89%split: test · fine-tuned · classes=binary · backbone=3D-ResNet18Med3D: Transfer Learning for 3D Medical Image Analysis
Source quote
L155: Med3D │ 87.26% │ 88.89%
20183D ResNet-152 (Raw + Synthesis) proposedACC0.9171split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812
20183D ResNet-152 (Raw + Synthesis) proposedSPE0.9774split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812
20183D ResNet-152 (Raw + Synthesis) proposedAUC0.8812split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812
2018Mean across network architectures (Raw + Synthesis) proposedAUC0.8696split: test · backbone=mean across four 3D CNN architectures · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L139: Mean │ 0.8821 │ 0.6353 │ 0.9266 │ 0.8696
2016ReCTnet proposedSensitivity90.5%split: test · test-scans=150 · training-scans=600 · operating-point=4.5 FPs/scan (p=0.75) · target-criterion=confirmed by all 4 radiologistsRecurrent Convolutional Networks for Pulmonary Nodule Detection in CT Imaging
Source quote
L158: ReCTnet │ {\bf 90.5} % │ {\bf 4.5} │ 600 │ 150
2016ReCTnet proposedFalse positives per scan4.5 FPs/scansplit: test · test-scans=150 · training-scans=600 · operating-point=paired with 90.5% sensitivity (p=0.75) · target-criterion=confirmed by all 4 radiologistsRecurrent Convolutional Networks for Pulmonary Nodule Detection in CT Imaging
Source quote
L158: ReCTnet │ {\bf 90.5} % │ {\bf 4.5} │ 600 │ 150