LIDC-IDRI
51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | 2D LS-AAE SOTA frontier (+1 variant) | 0.944 | 2021-01-01 | convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4 · Ablation study with projection-sampling interval 4 (the ablation default); 2D convolu… | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quote2D LS-AAE │ 39.472 │ 0.944 |
| 2 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) | 0.924 | 2022-01-01 | resolution=256×256 · projections=40 · Evaluation on patient datasets unseen during training and validation; images downsamp… | CNN-based regularisation for CT image reconstructionsSource quoteSSIM │ 0.362 │ 0.924 |
| 3 | OW-CNFs | 0.819 | 2024-10-01 | I0=1×10^4 · Average on the LIDC-IDRI test set (30 images); simulated low-dose projections at I0=1… | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteOW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 4 | DVG-Diffusion (+3 variants) | 0.679 | 2025-03-01 | Ablation result; biplanar X-ray inputs; evaluated on the 102-volume test split. | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteDVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35 |
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2022 | C,S,F,ad-CSL proposed | AUC | 96.10% | split: val · 5-fold-cross-validation · delta=0.5 · subset=unsure data · variant=ad-CSL · scenario=12/45 | Faithful learning with sure data for lung nodule diagnosisSource quoteL624: \multicolumn{1}{l}{} │ C,S,F,ad-CSL │ 85.54 │ 96.81 │ 95.85 │ 88.85 │ 91.67 │ 96.10 │ 90.38 |
| 2022 | C,S,F,ad-CSL proposed | F1 | 90.38% | split: val · 5-fold-cross-validation · delta=0.5 · subset=unsure data · variant=ad-CSL · scenario=12/45 | Faithful learning with sure data for lung nodule diagnosisSource quoteL624: \multicolumn{1}{l}{} │ C,S,F,ad-CSL │ 85.54 │ 96.81 │ 95.85 │ 88.85 │ 91.67 │ 96.10 │ 90.38 |
| 2021 | RNet proposed | AUC | 95.21 | split: val · 5-fold-cross-validation | Interpretative Computer-aided Lung Cancer Diagnosis: from Radiology Analysis to Malignancy EvaluationSource quoteL191: RNet │ 95.50 │ 89.88 │ 91.01 │ 96.63 │ 95.21 |
| 2021 | R2MNet proposed | AUC | 97.08 | split: val · 5-fold-cross-validation | Interpretative Computer-aided Lung Cancer Diagnosis: from Radiology Analysis to Malignancy EvaluationSource quoteL192: R2MNet │ 96.63 │ 92.13 │ 91.01 │ 97.75 │ 97.08 |