| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | 2D LS-AAE SOTA frontier (+1 variant) | 0.944 | 2021-01-01 | convolution=2D · input-treatment=images as input channels · projection-sampling-interval=4 · Ablation study with projection-sampling interval 4 (the ablation default); 2D convolu… | A Lightweight Structure Aimed to Utilize Spatial Correlation for Sparse-View CT ReconstructionSource quote2D LS-AAE │ 39.472 │ 0.944 |
| 2 | MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) | 0.924 | 2022-01-01 | resolution=256×256 · projections=40 · Evaluation on patient datasets unseen during training and validation; images downsamp… | CNN-based regularisation for CT image reconstructionsSource quoteSSIM │ 0.362 │ 0.924 |
| 3 | OW-CNFs | 0.819 | 2024-10-01 | I0=1×10^4 · Average on the LIDC-IDRI test set (30 images); simulated low-dose projections at I0=1… | Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing FlowsSource quoteOW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819 |
| 4 | DVG-Diffusion (+3 variants) | 0.679 | 2025-03-01 | Ablation result; biplanar X-ray inputs; evaluated on the 102-volume test split. | DVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-RaysSource quoteDVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35 |
Showing 6 of 6 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | CLS-DM proposed | PSNR | 27.36 dB | 2-view · views=frontal-and-lateral · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL226: CLS-DM (ours) │ 23.02 │ 0.5931 │ 24.96 │ 0.6585 │ 27.36 │ 0.7058 |
| 2025 | CLS-DM proposed | SSIM | 0.7058 | 2-view · views=frontal-and-lateral · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL226: CLS-DM (ours) │ 23.02 │ 0.5931 │ 24.96 │ 0.6585 │ 27.36 │ 0.7058 |
| 2025 | w/o CLIP ablation | PSNR | 25.37 dB | 2-view · views=frontal-and-lateral · variant=without-contrastive-learning · backbone=CLIP · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL221: w/o CLIP │ 22.42 │ 0.5919 │ 25.17 │ 0.6591 │ 25.37 │ 0.6701 |
| 2025 | w/o CLIP ablation | SSIM | 0.6701 | 2-view · views=frontal-and-lateral · variant=without-contrastive-learning · backbone=CLIP · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL221: w/o CLIP │ 22.42 │ 0.5919 │ 25.17 │ 0.6591 │ 25.37 │ 0.6701 |
| 2025 | w/o CLIP, AR (LDM) ablation | PSNR | 24.94 dB | 2-view · views=frontal-and-lateral · variant=without-contrastive-learning-and-autoregressive-constraint · backbone=LDM · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL225: w/o CLIP,AR(LDM) │ 20.65 │ 0.5864 │ 24.73 │ 0.6473 │ 24.94 │ 0.6515 |
| 2025 | w/o CLIP, AR (LDM) ablation | SSIM | 0.6515 | 2-view · views=frontal-and-lateral · variant=without-contrastive-learning-and-autoregressive-constraint · backbone=LDM · hu-range=0-4095 · precision=12-bit | Latent Space Consistency for Sparse-View CT ReconstructionSource quoteL225: w/o CLIP,AR(LDM) │ 20.65 │ 0.5864 │ 24.73 │ 0.6473 │ 24.94 │ 0.6515 |