LIDC-IDRI

51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.50.70.81.0202120232025SIB (single Inpainting Block): 0.941 (2021)2D LS-AAE: 0.944 (2021)MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet): 0.924 (2022)OW-CNFs: 0.819 (2024)DVG-Diffusion (without new-view input): 0.532 (2025)DVG-Diffusion (90° synthesized view): 0.541 (2025)VPGE-Diffusion: 0.667 (2025)DVG-Diffusion: 0.679 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025DVG-Diffusion (90° synthesized view) proposedSSIM0.541split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537
2025DVG-Diffusion ablationSSIM0.679split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L228: DVG-Diffusion (Ours) │ \checkmark │ \checkmark │ \checkmark │ 26.84 │ 0.679 │ 27.35
2025VPGE-Diffusion ablationSSIM0.667split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L227: \checkmark │ 26.47 │ 0.667 │ 28.11
2025DVG-Diffusion (without new-view input) ablationSSIM0.532split: testDVG-Diffusion: Dual-View Guided Diffusion Model for CT Reconstruction from X-Rays
Source quote
L275: SSIM \uparrow │ 0.532 │ 0.537 │ 0.539 │ 0.540 │ 0.539 │ 0.541 │ 0.537
2024OSEM-CPNN proposedSSIM0.950split: test · fine-tuned · dose=I₀=1×10⁴ · resolution=256×256 · detector-cells=512 · projection-angles=360 · fine-tuning-epochs=50A Low-dose CT Reconstruction Network Based on TV-regularized OSEM Algorithm
Source quote
L374: OSEM-CPNN │ 40.86 │ 0.985 │ 36.49 │ 0.950 │ 3.63s │ 7.20M
2024OW-CNFs proposedSSIM0.819split: test · I0=1×10^4Unsupervised Low-dose CT Reconstruction with One-way Conditional Normalizing Flows
Source quote
L272: OW-CNFs │ 38.60 │ 0.972 │ 33.14 │ 0.819
2022MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet) proposedSSIM0.924split: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1039: SSIM │ 0.362 │ 0.924
2022FBP baselineSSIM0.362split: test · resolution=256×256 · projections=40CNN-based regularisation for CT image reconstructions
Source quote
L1039: SSIM │ 0.362 │ 0.924