LIDC-IDRI

51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.50.70.81.0202120232025SIB (single Inpainting Block): 0.941 (2021)2D LS-AAE: 0.944 (2021)MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet): 0.924 (2022)OW-CNFs: 0.819 (2024)DVG-Diffusion (without new-view input): 0.532 (2025)DVG-Diffusion (90° synthesized view): 0.541 (2025)VPGE-Diffusion: 0.667 (2025)DVG-Diffusion: 0.679 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 5 of 5 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Harmonizer Network (Harmonizer, ours) proposedDSC84.27split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L416: 89.37 │ 1.44 │ 87.92 │ 2.88 │ 84.27 │ 6.53
2026D-PersonaDSC71.11split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L411: 85.74 │ 3.43 │ 81.80 │ 7.37 │ 71.11 │ 18.06
2026Harmonizer NetworkDSC85.30split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L616: 85.30 │ 5.48
2026D-PersonaDSC83.02split: testHarmonized Feature Conditioning and Frequency-Prompt Personalization for Multi-Rater Medical Segmentation
Source quote
L613: 83.02 │ 6.15
2024SCA-VNet baselineDSC87.50%split: testMedical artificial intelligence for early detection of lung cancer: A survey
Source quote
L296: Liu et al. {\cite{liu2024multiscale}} │ 2024 │ LIDC-IDRI │ SCA-VNet │ Residual edge enhancement │ PyTorch 1.12.1 │ DSC: 87.50% ; Sensitivity: 86.80% ; Precision: 88.32%