LIDC-IDRI

51 papers · 161 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.50.70.81.0202120232025SIB (single Inpainting Block): 0.941 (2021)2D LS-AAE: 0.944 (2021)MC-S-P-ConvNet (measurement-consistent, sparsifying postprocess-ConvNet): 0.924 (2022)OW-CNFs: 0.819 (2024)DVG-Diffusion (without new-view input): 0.532 (2025)DVG-Diffusion (90° synthesized view): 0.541 (2025)VPGE-Diffusion: 0.667 (2025)DVG-Diffusion: 0.679 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 5 of 5 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024CcCL-assisted CdTransformer proposedACC improvement4.82%Table 5 reports the improvement on LIDC-IDRI relative to the baseline; the text does no…Class-consistent Contrastive Learning Driven Cross-dimensional Transformer for 3D Medical Image Classification
Source quote
L685: Table 5. The CcCL assists CdTransformer to obtain an improvement on AUC, ACC, Precision, and F1-Score on the six 3D medical datasets. The CcCL assists CdTransformer in obtaining a 4.55%, 4.82%, 8.18%, and 4.39% improvement on AUC, ACC, Precision, and F1-Score on LIDC-IDRI dataset. What’s more, in the five 3D MedMNIST, CcCL also improved the performance of model.
2019Med3D-pretrained 3D-ResNet18 proposedAccuracy88.89%split: test · fine-tuned · classes=binary · backbone=3D-ResNet18Med3D: Transfer Learning for 3D Medical Image Analysis
Source quote
L155: Med3D │ 87.26% │ 88.89%
20183D CNN MTL with Trace norm proposed non-standard sliceAccuracy80.08%split: val · 10-fold-cross-validation · exclusion=nodules with mean malignancy score 3 · cross-validation=10-fold · correctness-tolerance=within ±1 of ground-truth scoreLung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning Approaches
Source quote
L235: 3D CNN MTL with Trace norm │ 80.08 │ 0.626
20183D ResNet-152 (Raw + Synthesis) proposedACC0.9171split: test · backbone=3D ResNet-152 · training-data=original patches + 463 synthesized malignant patchesClass-Aware Adversarial Lung Nodule Synthesis In CT Images
Source quote
L137: ResNet-152 │ 0.9171 │ 0.5833 │ 0.9774 │ 0.8812
2015Discovery radiomics framework proposedaverage accuracy77.52%split: val · subset=pathologically-proven data from 97 patients · evaluation=10-fold cross-validationDiscovery Radiomics for Pathologically-Proven Computed Tomography Lung Cancer Prediction
Source quote
L8: Lung cancer is the leading cause for cancer related deaths. As such, there is an urgent need for a streamlined process that can allow radiologists to provide diagnosis with greater efficiency and accuracy. A powerful tool to do this is radiomics: a high-dimension imaging feature set. In this study, we take the idea of radiomics one step further by introducing the concept of discovery radiomics for lung cancer prediction using CT imaging data. In this study, we realize these custom radiomic sequencers as deep convolutional sequencers using a deep convolutional neural network learning architecture. To illustrate the prognostic power and effectiveness of the radiomic sequences produced by the discovered sequencer, we perform cancer prediction between malignant and benign lesions from 97 patients using the pathologically-proven diagnostic data from the LIDC-IDRI dataset. Using the clinically provided pathologically-proven data as ground truth, the proposed framework provided an average accuracy of 77.52% via 10-fold cross-validation with a sensitivity of 79.06% and specificity of 76.11%, surpassing the state-of-the art method.