CheXpert
131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | final model (ensemble of the best performing networks) SOTA frontier | 0.94 | 2021-01-01 | labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensemble · Mean over 5 selected pathologies; validation studies use the majority vote of 3 board… | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteThe chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2 | DenseNet121-MaxAUC | 0.935 | 2023-01-01 | subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGrad · Mean across Cardiomegaly, Edema, Consolidation, Atelectasis, and Pleural Effusion. Ma… | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteDenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935 |
| 3 | FDAM (DenseNet161) (+1 variant) | 0.9333 | 2021-01-01 | K=2; training uses CheXpert and ChestXray8 data. Evaluated on CheXpert validation dat… | Federated Deep AUC Maximization for Hetergeneous Data with a Constant Communication ComplexitySource quote0.9333 |
| 4 | Proposed MARL framework (Ours, ResNet) | 0.925 | 2023-01-01 | backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1 · Validation set; mean over the five competition-task pathologies. Uncertain labels map… | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925 |
| 5 | Proposed instrumental variable learning framework | 0.923 | 2023-01-01 | uncertain-labels=mapped-to-1 · Average across five competition-task pathologies; the evaluation section states uncer… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923 |
Showing 111 of 111 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.487 | split: test | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL307: both models (0.487 and 0.536, with intervals including 0.5). |
| 2026 | Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.536 | split: test · backbone=ViT-B/16 | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL307: both models (0.487 and 0.536, with intervals including 0.5). |
| 2026 | MedRAX + CRC-Router (TTA) proposed | Macro wrong-accept risk | 4.6% | split: test | CRC-Router: Risk-Constrained Routing for Medical Agentic AI SystemsSource quoteL186: Macro Risk │ 5.7% │ 4.8% │ 3.8% │ Macro Risk │ 20.9% │ 4.6% |
| 2026 | TENT baseline | mean AUROC | 77.4 | split: test · test-time-adaptation | Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray DiagnosisSource quoteL141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4 |
| 2026 | OMIB (Wu et al., 2025) baseline | mAUC | 89.3% | split: test · subset=five diseases | IBMA: Information Bottleneck-Based Multimodal AlignmentSource quoteL479: 89.3 |
| 2025 | DLDM (disentangled latent diffusion model) proposed | Effectiveness Accuracy | 88.7% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL558: DLDM │ 88.7 │ 91.8 │ 93.3 |
| 2025 | Synthetic+Real mix model proposed | AUROC | 0.730 | split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained · evaluation-view=PA | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733), |
| 2025 | RR-ClArC (ResNet50) proposed | Accuracy (biased) | 0.79 | split: test · artifact=brightness · backbone=ResNet-50 | Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated dataSource quoteL1119: RR-ClArC │ {0.86} \,|\, {0.97} \,|\, {0.82} │ 0.76 \,|\, 0.96 \,|\, 0.79 │ 0.42 \,|\, {0.34} \,|\, - │ 0.00 \,|\, 0.07 \,|\, 0.00 |
| 2025 | U-Net + Text Encoder fine-tuning proposed | Accuracy | 94.8% | split: test · subset=No Finding · resolution=512×512 | Pixels Under Pressure: Exploring Fine-Tuning Paradigms for Foundation Models in High-Resolution Medical ImagingSource quoteL156: When evaluated on real test images after training on synthetic data (Table~\ref{tab:model_accuracy}), models fine-tuned on both U-Net and Text Encoder achieve the highest accuracy across nearly all disease categories (e.g., 77.9% for Cardiomegaly, 94.8% for No Finding), highlighting strong generalization. BitFit also performs surprisingly well in this evaluation, suggesting that while it may underperform in generation quality, its generated images still retain enough semantic structure to be informative for downstream classification. LoRA and DoRA also demonstrate robust cross-domain transfer, particularly in high-signal classes such as Pneumothorax and No Finding, underscoring their utility as efficient yet effective fine-tuning alternatives. |
| 2025 | Diff3M (Ours_demo) proposed | AUPRC | 0.931 | split: test · variant=Ours_demo · sampling=600-step DDIM · demographics=used | Harnessing EHRs for Diffusion-Based Anomaly Detection on Chest X-RaysSource quoteL181: AUPRC │ 0.888 │ 0.719 │ 0.889 │ 0.917 │ 0.931 |
| 2025 | CLDM (standard conditional latent diffusion model) baseline | Effectiveness Accuracy | 83.5% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL557: CLDM │ 83.5 │ 87.2 │ 89.1 |
| 2025 | Real-only baseline baseline | AUROC | 0.700 | split: test · training-data=66k real MIMIC-CXR images · initialization=ImageNet-pretrained · evaluation-view=PA | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733), |
| 2025 | GLoRIA baseline | Average accuracy | 50.00% | split: test · fine-tuned · tasks=Consolidation; Pleural Effusion · image-view=frontal | Enhancing Biomedical Multi-modal Representation Learning with Multi-scale Pre-training and Perturbed Report DiscriminationSource quoteL142: GLoRIA \cite{huang2021gloria} │ 71.11% │ 28.89% │ 50.00% |
| 2025 | Vanilla (ResNet50) baseline | Accuracy (biased) | 0.44 | split: test · artifact=brightness · backbone=ResNet-50 | Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated dataSource quoteL1115: Vanilla │ {0.87} \,|\, {0.97} \,|\, {0.81} │ {0.28} \,|\, {0.62} \,|\, {0.44} │ {0.55} \,|\, {0.51} \,|\, - │ {0.17} \,|\, {0.30} \,|\, {0.33} |
| 2025 | Baseline (ResNet50) baseline | Worst-group accuracy (WGAcc) | 25.87% | split: test · folds=4 held-out · backbone=ResNet50 · evaluation=test-time attenuation | Localising Shortcut Learning in Pixel Space via Ordinal Scoring Correlations for Attribution Representations (OSCAR)Source quoteL590: ResNet50 │ CheXpert │ Baseline │ 65.61 │ 25.87 |
| 2025 | DiAD baseline | AUPRC | 0.917 | split: test | Harnessing EHRs for Diffusion-Based Anomaly Detection on Chest X-RaysSource quoteL181: AUPRC │ 0.888 │ 0.719 │ 0.889 │ 0.917 │ 0.931 |
| 2024 | MGCA with 2x synthetic augmentation using single-disease prompts proposed non-standard slice | mean F1 score | 0.289 | split: test · 1-shot · prompt=single-disease · backbone=MGCA · training-data=1% ground-truth · synthetic-augmentation=2x | Evaluating and Improving the Effectiveness of Synthetic Chest X-Rays for Medical Image AnalysisSource quoteL34: In multilabel classification on CheXpert dataset, we also found it was most effective to generate the synthetic data using single-disease prompts (e.g. "cardiomegaly"), and the synthetic data was used to balance all classes to the count of the most frequent disease class. At 1% ground truth data, the mean F1 score increased from 0.209 with real data to 0.289 with 2x synthetic data. At 10% ground truth data, the F1 score improved from 0.255 to 0.323 with 2x synthetic data. At 100% ground truth data, synthetic data provided marginal improvements, with the F1 score increasing from 0.310 to 0.354 with balanced 2x synthetic augmentation (Figure \ref{fig:results}, Plot 4). These results demonstrate that the strategic addition of synthetic data can address class imbalance and significantly improve multilabel classification performance, especially in low-resource scenarios. |
| 2024 | LLaVA-Med (PT2) proposed | F1 | 23.2 | split: test · prompt=PT2 · category=Edema | Prompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question AnsweringSource quoteL242: F1 │ 23.2 │ 42.6 |
| 2024 | LLaVA-Med (PT3) proposed | F1 | 42.6 | split: test · prompt=PT3 · category=Edema | Prompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question AnsweringSource quoteL242: F1 │ 23.2 │ 42.6 |
| 2024 | LLaVA-Med (PT2) proposed | false positive count | 410 count | split: test · prompt=PT2 · category=Edema | Prompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question AnsweringSource quoteL263: Edema │ 410 │ 88 |
| 2024 | LLaVA-Med (PT3) proposed | false positive count | 88 count | split: test · prompt=PT3 · category=Edema | Prompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question AnsweringSource quoteL263: Edema │ 410 │ 88 |
| 2024 | Attri-Net (unguided) proposed | Confounder sensitivity | 0.747 | split: test · unguided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samples | Attri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific CounterfactualsSource quoteL363: Since we have introduce a known shortcut behaviour on the tag signal, we expect a global explanation to correctly highlight the reliance on the tag signal in contaminated test images. To measure this we have previously introduced the confounder sensitivity metric~\citep{sun2023right}. Confounder sensitivity measures how many of the top 10% most significant pixels identified by the explanation fall on the synthetically added tag signal. We computed the confounder sensitivity using the positive class center of cardiomegaly, resulting in a score of 0.747. This indicates that 74.7% of |
| 2024 | Attri-Net (with guidance) proposed | Confounder sensitivity | 0.002 | split: test · guided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samples | Attri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific CounterfactualsSource quoteL366: To further verify that adding guidance can direct the model towards using the correct features, we added the guidance shown in Fig.~\ref{fig:guidance_shortcut}(c) to the model to encourage the model to avoid using spurious signals. After adding guidance, the confounder sensitivity of the new class center dropped to 0.002, which means that the most significant explanation pixels are not on the spurious signals anymore. |
| 2024 | Fair Diagnosis (ResNet50) proposed | ACC | 86.40% | split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34 |
| 2024 | Fair Diagnosis (ResNet50) proposed non-standard slice | ADF (column label: ADF-e-3) | 1.34 | split: test · η=0.2 · backbone=ResNet50 · metric_scale=e-3 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34 |
| 2024 | RadGazeGen proposed | AUC (Avg across 12 pathologies) | 71.33 | split: test · classes=12 pathologies · sample-size=500 | RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion ModelsSource quoteL207: RadGazeGen │ 80.71 │ 70.34 │ 77.67 │ 73.47 │ 66.57 │ 88.20 │ 78.31 │ 53.29 │ 77.46 │ 62.74 │ 52.32 │ 74.90 │ 71.33 |
| 2024 | \imgedit (white-box) proposed | EO_p | 28.5 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | \imgedit (white-box) proposed | DI disparity (|1−DI|) | 25.6 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | \imgedit (white-box) proposed | Acc | 75.1 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposed | AUC | 72.24 | split: test · training-data=10% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL289: 72.24 |
| 2024 | DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposed | AUC | 91.02 | split: test · training-data=40% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL292: 91.02 |
| 2024 | DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposed | AUC | 98.21 | split: test · training-data=100% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL298: 98.21 |
| 2024 | MSN+x-SM | AUROC | 0.766 | split: test · linear-probe · backbone=ViT-T | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL550: MSN+ x-SM │ 0.766 (0.745, 0.786) \color{green}\uparrow\uparrow │ 0.402 (0.387, 0.427) \color{green}\uparrow │ \color{blue}{0.716^* (0.712, 0.719)} \color{green}\uparrow\uparrow │ \color{blue}{0.241^* (0.236, 0.249)} \color{green}\uparrow\uparrow |
| 2024 | Subset 0 (approximately indistinguishable partition) non-standard slice | Share of evaluated patients | 29.6% | split: test · subset=0 · holdout-size=500 radiographs | Human Expertise in Algorithmic PredictionSource quoteL169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%. |
| 2024 | ResNet-18 baseline | Test loss | 0.7712 | split: test · backbone=ResNet-18 · training-size=9250 | The Effect of Intrinsic Dataset Properties on Generalization: Unraveling Learning Differences Between Natural and Medical ImagesSource quoteL484: 9250 │ 0.7712 │ 0.6370 │ 0.6789 │ 0.6014 │ 0.6014 │ 0.6016 |
| 2024 | ResNet-18 baseline | Test loss | 1.3479 | split: test · backbone=ResNet-18 · training-size=1000 | The Effect of Intrinsic Dataset Properties on Generalization: Unraveling Learning Differences Between Natural and Medical ImagesSource quoteL485: 1000 │ 1.3479 │ 0.7894 │ 0.9793 │ 0.6700 │ 0.7409 │ 0.6806 |
| 2024 | MGCA, real-only training baseline non-standard slice | mean F1 score | 0.209 | split: test · 1-shot · backbone=MGCA · augmentation=real-only · training-data=1% ground-truth | Evaluating and Improving the Effectiveness of Synthetic Chest X-Rays for Medical Image AnalysisSource quoteL34: In multilabel classification on CheXpert dataset, we also found it was most effective to generate the synthetic data using single-disease prompts (e.g. "cardiomegaly"), and the synthetic data was used to balance all classes to the count of the most frequent disease class. At 1% ground truth data, the mean F1 score increased from 0.209 with real data to 0.289 with 2x synthetic data. At 10% ground truth data, the F1 score improved from 0.255 to 0.323 with 2x synthetic data. At 100% ground truth data, synthetic data provided marginal improvements, with the F1 score increasing from 0.310 to 0.354 with balanced 2x synthetic augmentation (Figure \ref{fig:results}, Plot 4). These results demonstrate that the strategic addition of synthetic data can address class imbalance and significantly improve multilabel classification performance, especially in low-resource scenarios. |
| 2024 | MMCLIP baseline | AUC | 90.53 | split: test · 0-shot · subset=500 images | XLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-TrainingSource quoteL262: MMCLIP │ 90.53 │ 67.05 │ 86.04 │ 85.79 │ 33.50 │ 91.19 │ 86.16 │ 62.57 │ 80.46 |
| 2024 | MedKlip baseline | AUC | 89.97 | split: test · 0-shot · subset=500 images | XLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-TrainingSource quoteL260: MedKlip \cite{wu2023medklip} │ 89.97 │ 63.67 │ 84.32 │ 84.97 │ 35.17 │ 90.68 │ 86.94 │ 63.42 │ 80.02 |
| 2024 | MSN baseline | AUROC | 0.740 | split: test · linear-probe · backbone=ViT-T | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL534: MSN │ 0.740 (0.720, 0.763) │ 0.396 (0.382, 0.421) │ 0.676 (0.671, 0.68) │ 0.199 (0.197, 0.203) |
| 2024 | SD baseline | AUC (Avg across 12 pathologies) | 71.12 | split: test · classes=12 pathologies · sample-size=500 | RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion ModelsSource quoteL204: SD │ 72.57 │ 73.64 │ 73.77 │ 75.28 │ 64.24 │ 83.32 │ 74.59 │ 68.07 │ 59.24 │ 58.36 │ 71.70 │ 78.67 │ 71.12 |
| 2024 | MINE baseline | AUROC | 87.7 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=inverted | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4 |
| 2024 | Rebalance baseline | AUROC | 79.8 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=inverted | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8 |
| 2024 | MINE baseline | AUROC | 92.4 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balanced | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4 |
| 2024 | Rebalance baseline | AUROC | 90.0 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balanced | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8 |
| 2024 | Radiologist 1 baseline non-standard slice | True negative rate (TNR) | 42.9% | split: test · subset=0 · ground-truth=majority vote of five radiologists · holdout-size=500 radiographs | Human Expertise in Algorithmic PredictionSource quoteL169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%. |
| 2024 | Eight leaderboard algorithms baseline non-standard slice | True negative rate (TNR) | 0% | split: test · models=eight leaderboard algorithms · subset=0 · ground-truth=majority vote of five radiologists | Human Expertise in Algorithmic PredictionSource quoteL169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%. |
| 2024 | BiasAdv baseline | EO_p | 39.0 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL172: BiasAdv~\cite{lim2023biasadv} │ 39.0 │ 54.5 │ 58.2 │ 71.1 │ 36.0 │ 54.0 │ 77.1 │ 61.0 │ 39.0 │ 33.5 │ 36.6 │ 74.9 |
| 2024 | Batch Samp. baseline | DI disparity (|1−DI|) | 51.8 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0 |
| 2024 | Batch Samp. baseline | Acc | 74.3 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0 |
| 2024 | GESTALT baseline | AUC | 70.82 | split: test · training-data=10% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL277: 70.82 |
| 2024 | GESTALT baseline | AUC | 89.27 | split: test · training-data=40% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL280: 89.27 |
| 2024 | GESTALT baseline | AUC | 96.71 | split: test · training-data=100% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL286: 96.71 |
| 2024 | Previous image baseline non-standard slice | macro-average AUROC | 0.572 | split: test · subset=Diff subset | Towards Predicting Temporal Changes in a Patient's Chest X-ray Images based on Electronic Health RecordsSource quoteL482: Previous image │ 0.768 │ 0.846 │ 0.572 |
| 2023 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposed | AUC | 89.24% | split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2023 | ELIXR-C proposed | Mean AUC | 0.850 | split: test · 0-shot · findings=13 | ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encodersSource quoteL434: 0.850 |
| 2023 | ELIXR-B linear proposed | Mean AUC | 0.893 | split: test · linear-probe · findings=5 · training-data=1% (~2,200 images) | ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encodersSource quoteL449: 0.893 |
| 2023 | PIE proposed | final disease classification confidence score | 0.690 | split: test · seeds=5 · steps=10 · classes-averaged=5 | PIE: Simulating Disease Progression via Progressive Image EditingSource quoteL150: In order to demonstrate the superior performance of PIE in disease progression simulation over other single-step editing methods, we perform experiments on three datasets previously mentioned. For each disease in these datasets, we used 10 healthy samples in the test set as simulation start point and run PIE, SD Video, Extrapolation with 5 random seeds. We obtain at least 50 disease imaging trajectories for each patient. Table~\ref{tab:performance} showcases that PIE consistently surpasses both SD Video and Extrapolation in terms of disease confidence scores while maintaining high CLIP-I scores. For Chexpert dataset, the 0.690 final confidence score is the average score among 5 classes. For Diabetic Retinopathy and ISIC 2018 datasets, we compare PIE with SD Video, Extrapolation for editing image to the most common seen class since these datasets are highly imbalanced. Figure~\ref{fig:comp_plots} illustrates the evolution of disease confidence scores during the progression simulation in each step. We observe that PIE is able to produce more faithful and realistic progressive editing compared to the other two baselines. Interestingly, while the CLIP-I score of Extrapolation is comparable to that of PIE, it fails to effectively edit the key disease features of the input images as its confidence scores are low throughout and at the end of the progression. We also visualize the absolute differences between initial stage and each progression stage of Cardiomegaly in Figure.~\ref{fig:progression_heatmap_visualization}. |
| 2023 | KAD proposed | Matthews Correlation Coefficient (MCC) | 0.613 | split: test · 0-shot | Knowledge-enhanced visual-language pre-training on chest radiology imagesSource quoteL449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly. |
| 2023 | KAD proposed | Matthews Correlation Coefficient (MCC) | 0.666 | split: test · 0-shot | Knowledge-enhanced visual-language pre-training on chest radiology imagesSource quoteL449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly. |
| 2023 | KAD proposed | Matthews Correlation Coefficient (MCC) | 0.702 | split: test · 0-shot | Knowledge-enhanced visual-language pre-training on chest radiology imagesSource quoteL449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly. |
| 2023 | KAD-multi proposed | aAUC | 0.8819 | split: test · averaging=macro over diseases · evaluation=in-domain | UniChest: Conquer-and-Divide Pre-Training for Multi-Source Chest X-Ray ClassificationSource quoteL230: KAD-multi │ 0.8431 │ 0.4077 │ 0.8905 │ 0.3457 │ 0.8819 │ 0.5912 │ 0.8713 │ 0.5626 │ 0.8716 │ 0.3698 │ 0.9390 │ 0.3202 |
| 2023 | Group-DRO classifier baseline non-standard slice | Spurious Correlation Latching Score (SCLS), difference in classifier outputs | 0.54 | split: test · subset=healthy and pleural-effusion images | Debiasing Counterfactuals In the Presence of Spurious CorrelationsSource quoteL20: In this paper, we propose the first end-to-end training framework for the explainability of classifier and debiasing via counterfactual image generation. We seek to discover imaging markers that reflect underlying disease pathology and that generalize across subgroups. Extensive experiments are performed on two different publicly available datasets - (i) \textit{\href{https://www.kaggle.com/c/rsna-pneumonia-detection-challenge/}{RSNA Pneumonia Detection Challenge}} and (ii) CheXpert \cite{irvin2019chexpert}. To illustrate the goal, Figure~\ref{fig:intro_problem} shows an example from the contrived CheXpert dataset, where most of the sick subjects have medical device(s) (e.g. a pacemaker) in their images while most of the healthy subjects do not. As such, there exists a spurious correlation between a confounding visual artifact (the medical devices) and the disease. A classifier based on a standard optimization technique, empirical risk minimization (ERM), incorrectly indicates the medical device as a disease marker, as depicted by the counterfactual (CF). In this work, we propose replacing ERM with a popular debiasing method, Group-DRO (distributional robust optimization). This permits the classifier to focus on the pathological image markers of the disease rather than on spurious correlation(s). Additionally, we show that Group-DRO ignores the visual artifact when making its decision, and generalizes across subgroups without the spurious correlation. Since standard metrics to evaluate counterfactuals do not indicate the region where the classifier focuses, we also propose a novel metric, the Spurious Correlation Latching Score (SCLS), to measure the degree to which the classifier latches onto spurious correlations. Our experiments indicate an improvement (in terms of differences in classifier outputs) of 0.68 and 0.54 in the SCLS using the Group-DRO classifier over the ERM |
| 2023 | Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baseline | AUC | 89.97% | split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2023 | CheXzero ensemble baseline | Mean AUC | 0.838 | split: test · 0-shot · method=CheXzero ensemble · findings=13 | ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encodersSource quoteL431: 0.838 |
| 2023 | Three radiologists (mean) baseline | Matthews Correlation Coefficient (MCC) | 0.507 | split: test · 0-shot | Knowledge-enhanced visual-language pre-training on chest radiology imagesSource quoteL449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly. |
| 2022 | Stable Diffusion fine-tuned for 60k steps at lr 1e-4, with U-Net and text encoder unfrozen (PA training set) proposed | Pneumothorax class score (Pneux) | 59.8 | split: test · fine-tuned · class=Pneumothorax · model=Stable Diffusion · learning-rate=1e-4 · training-steps=60k · unfrozen-components=U-Net and text encoder | RoentGen: Vision-Language Foundation Model for Chest X-ray GenerationSource quoteL412: ~ lr 1e-4 │ 50 │ 6.4 │ 59.8 │ 34.4 |
| 2022 | FedKD (Cross-domain) proposed | test mAUC | 79.77% | split: test · classes=8 · local-nodes=2 · local-private-data=CXR14+Xpert | Preserving Privacy in Federated Learning with Ensemble Cross-Domain Knowledge DistillationSource quoteL263: CXR14+Xpert │ Xpert │ 79.77 │ 80.91 \\} |
| 2022 | FedKD (Cross-domain) proposed | test mAUC | 80.91% | split: test · classes=8 · local-nodes=6 · local-private-data=CXR14+Xpert | Preserving Privacy in Federated Learning with Ensemble Cross-Domain Knowledge DistillationSource quoteL263: CXR14+Xpert │ Xpert │ 79.77 │ 80.91 \\} |
| 2022 | HeartSpot (RH)Line+Heart with a two-layer MLP proposed | AUC ROC | .78 | split: test · classifier=two-layer MLP · resolution=320×320 · training-iterations=300 | HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly DetectionSource quoteL122: For the MLP, we observe that HeartSpot\xspace (RH)Line+Heart is preferred, giving 17 seconds per epoch (8x faster than DenseNet121) and .78 AUC ROC. |
| 2022 | HeartSpot MP+HLine with DenseNet121 proposed | ROC AUC | .84 | split: test · backbone=DenseNet121 · resolution=320×320 · compression=MP+HLine | HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly DetectionSource quoteL123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline. |
| 2022 | HeartSpot MP+HLine with DenseNet121 proposed | ROC AUC improvement | +0.01 | split: test · backbone=DenseNet121 · comparison=baseline DenseNet121 · compression=MP+HLine | HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly DetectionSource quoteL123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline. |
| 2022 | DOS proposed | testing AUC | 0.65 | split: test · federated-learning · setting=final-crafted-model-attack | Suppressing Poisoning Attacks on Federated Learning for Medical ImagingSource quoteL126: Figure \ref{fig3} compares all the aggregation rules under six different scenarios on the CheXpert dataset. In the No Attack case, the DOS method outperforms Krum and produces comparable results to the other methods including FedAvg, which was essentially designed for benign settings. When one of the clients was trained by flipping class label 0 to 1, all of the methods performed well with Krum having a marginal advantage. For the mixed attack case, DOS had a faster convergence rate in the beginning with a marginal drop in round 70 whereas FedAvg was compromised. When four clients transmitted random Gaussian noise, FedAvg and Trimmed Mean were compromised, whereas DOS and Coordinate-Wise-Median performed best. In the noise and scaled parameters attack, FedAvg and Trimmed Mean were compromised from the start while the Coordinate-Wise-Median's performance started deteriorating at round 60. The DOS method and Krum performed best in this scenario. In the final crafted model setting, we compared DOS only with Krum as this attack was specifcially designed against Krum. In this attack, we can clearly see that DOS significantly outperforms Krum with a testing AUC of 0.65 vs. 0.50. Table \ref{labcomp} summarizes the average AUC for all rounds and it can be observed that DOS aggregation rule performs consistently well against all attack scenarios. In contrast, all the other aggregation rules had lower accuracy values in one or more scenarios. Furthermore, it can be observed from Figure \ref{fig3} that the weights of the malicious clients (shown in red) are almost always close to zero, indicating that the DOS method is able to effectively suppress the parameter updates from malicious clients. |
| 2022 | Original Stable Diffusion text encoder (baseline) baseline | Pneumothorax class score (Pneux) | 48.6 | split: test · class=Pneumothorax · model=Original Stable Diffusion · evaluation=CheXpert@10 | RoentGen: Vision-Language Foundation Model for Chest X-ray GenerationSource quoteL403: ~ original SD │ 61.6 │ 2.9 │ 48.6 │ 40.5 |
| 2022 | DAM (deep AUC maximization; specific method not named in the survey table) baseline | AUC | 0.9305 | split: test · imbalance=natural | AUC Maximization in the Era of Big Data and AI: A SurveySource quoteL579: CheXpert │ Chest X-ray Image │ 10^5 │ Natural │ \cite{irvin2019chexpert} │ \cite{DBLP:journals/corr/abs-2012-03173,zhubenchmark} │ 0.9305 |
| 2021 | Equal Loss Train, α=100 proposed | AUC | 0.835 | split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=male · method-setting=Equal Loss Train, α=100 | Technical Challenges for Training Fair Neural NetworksSource quoteL704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016 |
| 2021 | Equal Loss Train, α=100 proposed | AUC | 0.819 | split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=female · method-setting=Equal Loss Train, α=100 | Technical Challenges for Training Fair Neural NetworksSource quoteL704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016 |
| 2021 | Proposed method (HAM), ResNet50 backbone proposed | Mean AUC | 0.888 | split: test · backbone=ResNet50 · ensemble=no · uncertainty-labels=U-Ones | Learning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and DiagnosisSource quoteL760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy. |
| 2021 | Proposed method (HAM), ResNet152 backbone proposed | Mean AUC | 0.895 | split: test · backbone=ResNet152 · ensemble=no · uncertainty-labels=U-Ones | Learning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and DiagnosisSource quoteL760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy. |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.892 | split: test · disease=Pleural Effusion · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.961 | split: test · disease=Consolidation · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.924 | split: test · disease=Edema · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard slice | Micro F1, relation extraction | 0.725 | split: test · backbone=PubMedBERT · architecture=DYGIE++ | RadGraph: Extracting Clinical Entities and Relations from Radiology ReportsSource quoteL179: RadGraph Benchmark │ 0.709 │ 0.779 │ 0.588 │ 0.725 │ 0.692 |
| 2021 | RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard slice | Micro F1, named entity recognition | 0.905 | split: test · backbone=PubMedBERT · architecture=DYGIE++ | RadGraph: Extracting Clinical Entities and Relations from Radiology ReportsSource quoteL161: RadGraph Benchmark │ 0.941 │ 0.884 │ 0.714 │ 0.910 │ 0.905 │ 0.862 |
| 2021 | Any Disease model + Random Forest on the Penultimate Layer proposed | mean AUC | 0.879 | split: test · features=penultimate-layer · classifier=random-forest | CheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-raysSource quoteL256: 0.879 (0.849,0.901) |
| 2021 | Any Disease model + Random Forest on the Final Prediction Layer proposed | mean AUC | 0.875 | split: test · features=final-prediction-layer · classifier=random-forest | CheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-raysSource quoteL245: 0.875 (0.848,0.899) |
| 2021 | CheXseg (CAM, p=0.9) proposed | mIoU (Avg. IoU across 10 pathologies) | 0.299 | split: test · semi-supervised · backbone=ResNet18 · annotated-training-images=200 · pixel-labeled-example-probabilit=0.9 | CheXseg: Combining Expert Annotations with DNN-generated Saliency Maps for X-ray SegmentationSource quoteL189: \multirow{2}{*}{Avg. IoU} │ CAM │ 0.163 │ 0.269 │ 0.274 │ 0.273 │ 0.290 │ 0.292 │ 0.299 │ \multirow{2}{*}{0.263} |
| 2021 | VisualCheXbert (BERT+LogReg on MIMIC-CXR, DenseNet labels) proposed | Average F1 score | 0.68 | split: test · evaluation=average across 8 conditions · training-data=MIMIC-CXR · training-labels=DenseNet labels | VisualCheXbert: Addressing the Discrepancy Between Radiology Report Labels and Image LabelsSource quoteL196: Average │ 0.61 │ 0.68 │ 0.61 │ 0.67 |
| 2021 | CheXpert symbol proposed | Accuracy | 77.35% | split: test · backbone=ResNet50 · test_samples=234 · vocabulary_size=100 | Emergent Symbolic Language Based Deep Medical Image ClassificationSource quoteL105: 77.35 |
| 2021 | CheXpert symbol proposed | F1-score | 0.697 | split: test · backbone=ResNet50 · test_samples=234 · vocabulary_size=100 | Emergent Symbolic Language Based Deep Medical Image ClassificationSource quoteL106: 0.697 |
| 2021 | All Diseases ablation | mean AUC | 0.851 | split: test · training-setting=all-images-all-labels | CheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-raysSource quoteL175: 0.851 (0.828,0.871) |
| 2021 | Subset-Unlabeled ablation non-standard slice | mean AUC | 0.888 | split: test · training-setting=all-images-unseen-disease-labels-removed | CheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-raysSource quoteL181: 0.888 (0.868,0.906) |
| 2021 | Subset-Unseen ablation non-standard slice | mean AUC | 0.861 | split: test · training-setting=images-without-unseen-diseases | CheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-raysSource quoteL187: 0.861 (0.839,0.881) |
| 2021 | CAM (weakly supervised, p=0) ablation | mIoU (Avg. IoU across 10 pathologies) | 0.163 | split: test · weakly-supervised · backbone=ResNet18 · pixel-labeled-example-probabilit=0 | CheXseg: Combining Expert Annotations with DNN-generated Saliency Maps for X-ray SegmentationSource quoteL189: \multirow{2}{*}{Avg. IoU} │ CAM │ 0.163 │ 0.269 │ 0.274 │ 0.273 │ 0.290 │ 0.292 │ 0.299 │ \multirow{2}{*}{0.263} |
| 2021 | CheXpert baseline ablation | Accuracy | 73.07% | split: test · test_samples=234 · representation=continuous 2048-dimensional ResNet | Emergent Symbolic Language Based Deep Medical Image ClassificationSource quoteL101: 73.07 |
| 2021 | CheXpert baseline ablation | F1-score | 0.677 | split: test · test_samples=234 · representation=continuous 2048-dimensional ResNet | Emergent Symbolic Language Based Deep Medical Image ClassificationSource quoteL102: 0.677 |
| 2021 | BiT-M-50x1, pre-trained | ACE | 0.617 | split: test | The impact of domain shift on the calibration of fine-tuned modelsSource quoteL129: 0.617 |
| 2021 | BiT-M-50x1, not pre-trained | ACE | 0.285 | split: test | The impact of domain shift on the calibration of fine-tuned modelsSource quoteL134: 0.285 |
| 2021 | Pham et al. six-model ensemble baseline | Mean AUC | 0.930 | split: test · backbone=DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, NASNetLarge · ensemble=six-model | Learning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and DiagnosisSource quoteL760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy. |
| 2021 | Radiologist Benchmark baseline | Micro F1, relation extraction | 0.745 | split: test · reference=radiologist benchmark | RadGraph: Extracting Clinical Entities and Relations from Radiology ReportsSource quoteL178: Radiologist Benchmark │ 0.741 │ 0.779 │ 0.592 │ 0.745 │ 0.704 |
| 2021 | Fully supervised segmentation (p=1) baseline | mIoU (Avg. IoU across 10 pathologies) | 0.263 | split: test · fully-supervised · backbone=ResNet18 · pixel-labeled-example-probabilit=1 | CheXseg: Combining Expert Annotations with DNN-generated Saliency Maps for X-ray SegmentationSource quoteL189: \multirow{2}{*}{Avg. IoU} │ CAM │ 0.163 │ 0.269 │ 0.274 │ 0.273 │ 0.290 │ 0.292 │ 0.299 │ \multirow{2}{*}{0.263} |
| 2021 | IRNet (weakly supervised, p=0) baseline | mIoU (Avg. IoU across 10 pathologies) | 0.151 | split: test · weakly-supervised · backbone=ResNet18 · weak-label-method=IRNet · pixel-labeled-example-probabilit=0 | CheXseg: Combining Expert Annotations with DNN-generated Saliency Maps for X-ray SegmentationSource quoteL190: IRNet │ 0.151 │ 0.250 │ 0.257 │ 0.263 │ 0.281 │ 0.281 │ 0.294 |
| 2021 | Clustering selection baseline baseline | AUROC | 0.693 | split: test · few-shot · selected-labels=K=10 · condition-subset=non-holdout | MedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement LearningSource quoteL70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}. |
| 2021 | Clustering selection baseline baseline | AUROC | 0.850 | split: test · few-shot · selected-labels=K=10 · condition-subset=holdout: Edema and Atelectasis | MedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement LearningSource quoteL70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}. |
| 2021 | Zero-One Baseline (CheXpert report-labeler output) baseline | Average F1 score | 0.54 | split: test · method=CheXpert report-labeler · label-mapping=better of uncertain-to-negative or uncertain-to-positive; blanks-to-negative | VisualCheXbert: Addressing the Discrepancy Between Radiology Report Labels and Image LabelsSource quoteL177: Average │ 0.54 │ 0.65 |
| 2020 | proposed method (deep learning algorithm) proposed | mean AUC | 0.930 | split: test · subset=independent competition reader-study test set · labeling=consensus of 5 board-certified radiologists · pathologies=5 · sample-size=500 CXR studies | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteL4: The chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2020 | MaxAUC proposed | AUC | 0.922 | split: test · subset=five diseases · evaluation=competition private testing set | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteL293: It is notable that the current winner~\cite{pham2019interpreting} use all diseases and conditional training that incorporates the hierarchical taxonomy of 14 diseases to train deep networks, and they use an ensemble of 6 networks. In contrast, we only use the 5 diseases and train deep networks for each disease separately without using the domain knowledge. The final results in Table~\ref{table:chexpert} show that our ensemble model by AUC maximization has a better validation AUC than the current winner, and also improves the ensemble of based models trained by Adam by 1% on average. From the table, we also see that our method achieves the highest AUC on Edema, Consolidation, Atelectasis, competitive AUC on Pleural Effusion and slightly worse AUC on Cardiomegaly. On August 4, 2020, we submitted our models (MaxAUC) for evaluation on private testing set and the results ranks 35th on the CheXpert competition with an AUC of 0.922 on private testing set. |
| 2020 | ConVIRT | AUC | 85.9 | split: test · linear-probe | Contrastive Learning of Medical Visual Representations from Paired Images and TextSource quoteL368: ConVIRT │ 90.7 │ 85.9 │ 42.9 |
| 2020 | MoCo v2 | AUC | 81.3 | split: test · linear-probe | Contrastive Learning of Medical Visual Representations from Paired Images and TextSource quoteL367: MoCo v2 │ 86.6 │ 81.3 │ 20.6 |
| 2020 | Input Mixup baseline | Mean AUROC | 0.6731 | split: test · semi-supervised · classes=14 · labeled-samples=300 | Semi-supervised Medical Image Classification with Global Latent MixingSource quoteL359: Input Mixup │ 0.6491 │ 0.6627 │ 0.6731 │ 0.6779 │ 0.6823 │ 0.8504 │ 0.8609 │ 0.9040 |
| 2020 | Latent-space self-ensembling baseline | Mean AUROC | 0.6697 | split: test · semi-supervised · classes=14 · labeled-samples=500 | Semi-supervised Medical Image Classification with Global Latent MixingSource quoteL380: Latent-space self-ensembling │ 0.6200 │ 0.6386 │ 0.6484 │ 0.6637 │ 0.6697 |