CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 56 of 56 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard sliceAUROCf (failure-detection AUROC)0.487split: testCan saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L307: both models (0.487 and 0.536, with intervals including 0.5).
2026Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard sliceAUROCf (failure-detection AUROC)0.536split: test · backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L307: both models (0.487 and 0.536, with intervals including 0.5).
2026MedRAX + CRC-Router (TTA) proposedMacro wrong-accept risk4.6%split: testCRC-Router: Risk-Constrained Routing for Medical Agentic AI Systems
Source quote
L186: Macro Risk │ 5.7% │ 4.8% │ 3.8% │ Macro Risk │ 20.9% │ 4.6%
2025DLDM (disentangled latent diffusion model) proposedEffectiveness Accuracy88.7%split: test · intervention=do(A=black)AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L558: DLDM │ 88.7 │ 91.8 │ 93.3
2025Synthetic+Real mix model proposedAUROC0.730split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained · evaluation-view=PAImproving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic Data
Source quote
L139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733),
2025RR-ClArC (ResNet50) proposedAccuracy (biased)0.79split: test · artifact=brightness · backbone=ResNet-50Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated data
Source quote
L1119: RR-ClArC │ {0.86} \,|\, {0.97} \,|\, {0.82} │ 0.76 \,|\, 0.96 \,|\, 0.79 │ 0.42 \,|\, {0.34} \,|\, - │ 0.00 \,|\, 0.07 \,|\, 0.00
2025U-Net + Text Encoder fine-tuning proposedAccuracy94.8%split: test · subset=No Finding · resolution=512×512Pixels Under Pressure: Exploring Fine-Tuning Paradigms for Foundation Models in High-Resolution Medical Imaging
Source quote
L156: When evaluated on real test images after training on synthetic data (Table~\ref{tab:model_accuracy}), models fine-tuned on both U-Net and Text Encoder achieve the highest accuracy across nearly all disease categories (e.g., 77.9% for Cardiomegaly, 94.8% for No Finding), highlighting strong generalization. BitFit also performs surprisingly well in this evaluation, suggesting that while it may underperform in generation quality, its generated images still retain enough semantic structure to be informative for downstream classification. LoRA and DoRA also demonstrate robust cross-domain transfer, particularly in high-signal classes such as Pneumothorax and No Finding, underscoring their utility as efficient yet effective fine-tuning alternatives.
2025Diff3M (Ours_demo) proposedAUPRC0.931split: test · variant=Ours_demo · sampling=600-step DDIM · demographics=usedHarnessing EHRs for Diffusion-Based Anomaly Detection on Chest X-Rays
Source quote
L181: AUPRC │ 0.888 │ 0.719 │ 0.889 │ 0.917 │ 0.931
2024MGCA with 2x synthetic augmentation using single-disease prompts proposed non-standard slicemean F1 score0.289split: test · 1-shot · prompt=single-disease · backbone=MGCA · training-data=1% ground-truth · synthetic-augmentation=2xEvaluating and Improving the Effectiveness of Synthetic Chest X-Rays for Medical Image Analysis
Source quote
L34: In multilabel classification on CheXpert dataset, we also found it was most effective to generate the synthetic data using single-disease prompts (e.g. "cardiomegaly"), and the synthetic data was used to balance all classes to the count of the most frequent disease class. At 1% ground truth data, the mean F1 score increased from 0.209 with real data to 0.289 with 2x synthetic data. At 10% ground truth data, the F1 score improved from 0.255 to 0.323 with 2x synthetic data. At 100% ground truth data, synthetic data provided marginal improvements, with the F1 score increasing from 0.310 to 0.354 with balanced 2x synthetic augmentation (Figure \ref{fig:results}, Plot 4). These results demonstrate that the strategic addition of synthetic data can address class imbalance and significantly improve multilabel classification performance, especially in low-resource scenarios.
2024LLaVA-Med (PT2) proposedF123.2split: test · prompt=PT2 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L242: F1 │ 23.2 │ 42.6
2024LLaVA-Med (PT3) proposedF142.6split: test · prompt=PT3 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L242: F1 │ 23.2 │ 42.6
2024LLaVA-Med (PT2) proposedfalse positive count410 countsplit: test · prompt=PT2 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L263: Edema │ 410 │ 88
2024LLaVA-Med (PT3) proposedfalse positive count88 countsplit: test · prompt=PT3 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L263: Edema │ 410 │ 88
2024Attri-Net (unguided) proposedConfounder sensitivity0.747split: test · unguided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samplesAttri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific Counterfactuals
Source quote
L363: Since we have introduce a known shortcut behaviour on the tag signal, we expect a global explanation to correctly highlight the reliance on the tag signal in contaminated test images. To measure this we have previously introduced the confounder sensitivity metric~\citep{sun2023right}. Confounder sensitivity measures how many of the top 10% most significant pixels identified by the explanation fall on the synthetically added tag signal. We computed the confounder sensitivity using the positive class center of cardiomegaly, resulting in a score of 0.747. This indicates that 74.7% of
2024Attri-Net (with guidance) proposedConfounder sensitivity0.002split: test · guided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samplesAttri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific Counterfactuals
Source quote
L366: To further verify that adding guidance can direct the model towards using the correct features, we added the guidance shown in Fig.~\ref{fig:guidance_shortcut}(c) to the model to encourage the model to avoid using spurious signals. After adding guidance, the confounder sensitivity of the new class center dropped to 0.002, which means that the most significant explanation pixels are not on the spurious signals anymore.
2024Fair Diagnosis (ResNet50) proposedACC86.40%split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34
2024Fair Diagnosis (ResNet50) proposed non-standard sliceADF (column label: ADF-e-3)1.34split: test · η=0.2 · backbone=ResNet50 · metric_scale=e-3 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34
2024RadGazeGen proposedAUC (Avg across 12 pathologies)71.33split: test · classes=12 pathologies · sample-size=500RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion Models
Source quote
L207: RadGazeGen │ 80.71 │ 70.34 │ 77.67 │ 73.47 │ 66.57 │ 88.20 │ 78.31 │ 53.29 │ 77.46 │ 62.74 │ 52.32 │ 74.90 │ 71.33
2024\imgedit (white-box) proposedEO_p28.5split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024\imgedit (white-box) proposedDI disparity (|1−DI|)25.6split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024\imgedit (white-box) proposedAcc75.1split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC72.24split: test · training-data=10%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L289: 72.24
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC91.02split: test · training-data=40%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L292: 91.02
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC98.21split: test · training-data=100%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L298: 98.21
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC89.24%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023ELIXR-C proposedMean AUC0.850split: test · 0-shot · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L434: 0.850
2023ELIXR-B linear proposedMean AUC0.893split: test · linear-probe · findings=5 · training-data=1% (~2,200 images)ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L449: 0.893
2023PIE proposedfinal disease classification confidence score0.690split: test · seeds=5 · steps=10 · classes-averaged=5PIE: Simulating Disease Progression via Progressive Image Editing
Source quote
L150: In order to demonstrate the superior performance of PIE in disease progression simulation over other single-step editing methods, we perform experiments on three datasets previously mentioned. For each disease in these datasets, we used 10 healthy samples in the test set as simulation start point and run PIE, SD Video, Extrapolation with 5 random seeds. We obtain at least 50 disease imaging trajectories for each patient. Table~\ref{tab:performance} showcases that PIE consistently surpasses both SD Video and Extrapolation in terms of disease confidence scores while maintaining high CLIP-I scores. For Chexpert dataset, the 0.690 final confidence score is the average score among 5 classes. For Diabetic Retinopathy and ISIC 2018 datasets, we compare PIE with SD Video, Extrapolation for editing image to the most common seen class since these datasets are highly imbalanced. Figure~\ref{fig:comp_plots} illustrates the evolution of disease confidence scores during the progression simulation in each step. We observe that PIE is able to produce more faithful and realistic progressive editing compared to the other two baselines. Interestingly, while the CLIP-I score of Extrapolation is comparable to that of PIE, it fails to effectively edit the key disease features of the input images as its confidence scores are low throughout and at the end of the progression. We also visualize the absolute differences between initial stage and each progression stage of Cardiomegaly in Figure.~\ref{fig:progression_heatmap_visualization}.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.613split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.666split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.702split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD-multi proposedaAUC0.8819split: test · averaging=macro over diseases · evaluation=in-domainUniChest: Conquer-and-Divide Pre-Training for Multi-Source Chest X-Ray Classification
Source quote
L230: KAD-multi │ 0.8431 │ 0.4077 │ 0.8905 │ 0.3457 │ 0.8819 │ 0.5912 │ 0.8713 │ 0.5626 │ 0.8716 │ 0.3698 │ 0.9390 │ 0.3202
2022Stable Diffusion fine-tuned for 60k steps at lr 1e-4, with U-Net and text encoder unfrozen (PA training set) proposedPneumothorax class score (Pneux)59.8split: test · fine-tuned · class=Pneumothorax · model=Stable Diffusion · learning-rate=1e-4 · training-steps=60k · unfrozen-components=U-Net and text encoderRoentGen: Vision-Language Foundation Model for Chest X-ray Generation
Source quote
L412: ~ lr 1e-4 │ 50 │ 6.4 │ 59.8 │ 34.4
2022FedKD (Cross-domain) proposedtest mAUC79.77%split: test · classes=8 · local-nodes=2 · local-private-data=CXR14+XpertPreserving Privacy in Federated Learning with Ensemble Cross-Domain Knowledge Distillation
Source quote
L263: CXR14+Xpert │ Xpert │ 79.77 │ 80.91 \\}
2022FedKD (Cross-domain) proposedtest mAUC80.91%split: test · classes=8 · local-nodes=6 · local-private-data=CXR14+XpertPreserving Privacy in Federated Learning with Ensemble Cross-Domain Knowledge Distillation
Source quote
L263: CXR14+Xpert │ Xpert │ 79.77 │ 80.91 \\}
2022HeartSpot (RH)Line+Heart with a two-layer MLP proposedAUC ROC.78split: test · classifier=two-layer MLP · resolution=320×320 · training-iterations=300HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L122: For the MLP, we observe that HeartSpot\xspace (RH)Line+Heart is preferred, giving 17 seconds per epoch (8x faster than DenseNet121) and .78 AUC ROC.
2022HeartSpot MP+HLine with DenseNet121 proposedROC AUC.84split: test · backbone=DenseNet121 · resolution=320×320 · compression=MP+HLineHeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline.
2022HeartSpot MP+HLine with DenseNet121 proposedROC AUC improvement+0.01split: test · backbone=DenseNet121 · comparison=baseline DenseNet121 · compression=MP+HLineHeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline.
2022DOS proposedtesting AUC0.65split: test · federated-learning · setting=final-crafted-model-attackSuppressing Poisoning Attacks on Federated Learning for Medical Imaging
Source quote
L126: Figure \ref{fig3} compares all the aggregation rules under six different scenarios on the CheXpert dataset. In the No Attack case, the DOS method outperforms Krum and produces comparable results to the other methods including FedAvg, which was essentially designed for benign settings. When one of the clients was trained by flipping class label 0 to 1, all of the methods performed well with Krum having a marginal advantage. For the mixed attack case, DOS had a faster convergence rate in the beginning with a marginal drop in round 70 whereas FedAvg was compromised. When four clients transmitted random Gaussian noise, FedAvg and Trimmed Mean were compromised, whereas DOS and Coordinate-Wise-Median performed best. In the noise and scaled parameters attack, FedAvg and Trimmed Mean were compromised from the start while the Coordinate-Wise-Median's performance started deteriorating at round 60. The DOS method and Krum performed best in this scenario. In the final crafted model setting, we compared DOS only with Krum as this attack was specifcially designed against Krum. In this attack, we can clearly see that DOS significantly outperforms Krum with a testing AUC of 0.65 vs. 0.50. Table \ref{labcomp} summarizes the average AUC for all rounds and it can be observed that DOS aggregation rule performs consistently well against all attack scenarios. In contrast, all the other aggregation rules had lower accuracy values in one or more scenarios. Furthermore, it can be observed from Figure \ref{fig3} that the weights of the malicious clients (shown in red) are almost always close to zero, indicating that the DOS method is able to effectively suppress the parameter updates from malicious clients.
2021Equal Loss Train, α=100 proposedAUC0.835split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=male · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Equal Loss Train, α=100 proposedAUC0.819split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=female · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Proposed method (HAM), ResNet50 backbone proposedMean AUC0.888split: test · backbone=ResNet50 · ensemble=no · uncertainty-labels=U-OnesLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021Proposed method (HAM), ResNet152 backbone proposedMean AUC0.895split: test · backbone=ResNet152 · ensemble=no · uncertainty-labels=U-OnesLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.892split: test · disease=Pleural Effusion · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.961split: test · disease=Consolidation · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.924split: test · disease=Edema · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard sliceMicro F1, relation extraction0.725split: test · backbone=PubMedBERT · architecture=DYGIE++RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
Source quote
L179: RadGraph Benchmark │ 0.709 │ 0.779 │ 0.588 │ 0.725 │ 0.692
2021RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard sliceMicro F1, named entity recognition0.905split: test · backbone=PubMedBERT · architecture=DYGIE++RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
Source quote
L161: RadGraph Benchmark │ 0.941 │ 0.884 │ 0.714 │ 0.910 │ 0.905 │ 0.862
2021Any Disease model + Random Forest on the Penultimate Layer proposedmean AUC0.879split: test · features=penultimate-layer · classifier=random-forestCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L256: 0.879 (0.849,0.901)
2021Any Disease model + Random Forest on the Final Prediction Layer proposedmean AUC0.875split: test · features=final-prediction-layer · classifier=random-forestCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L245: 0.875 (0.848,0.899)
2021CheXseg (CAM, p=0.9) proposedmIoU (Avg. IoU across 10 pathologies)0.299split: test · semi-supervised · backbone=ResNet18 · annotated-training-images=200 · pixel-labeled-example-probabilit=0.9CheXseg: Combining Expert Annotations with DNN-generated Saliency Maps for X-ray Segmentation
Source quote
L189: \multirow{2}{*}{Avg. IoU} │ CAM │ 0.163 │ 0.269 │ 0.274 │ 0.273 │ 0.290 │ 0.292 │ 0.299 │ \multirow{2}{*}{0.263}
2021VisualCheXbert (BERT+LogReg on MIMIC-CXR, DenseNet labels) proposedAverage F1 score0.68split: test · evaluation=average across 8 conditions · training-data=MIMIC-CXR · training-labels=DenseNet labelsVisualCheXbert: Addressing the Discrepancy Between Radiology Report Labels and Image Labels
Source quote
L196: Average │ 0.61 │ 0.68 │ 0.61 │ 0.67
2021CheXpert symbol proposedAccuracy77.35%split: test · backbone=ResNet50 · test_samples=234 · vocabulary_size=100Emergent Symbolic Language Based Deep Medical Image Classification
Source quote
L105: 77.35
2021CheXpert symbol proposedF1-score0.697split: test · backbone=ResNet50 · test_samples=234 · vocabulary_size=100Emergent Symbolic Language Based Deep Medical Image Classification
Source quote
L106: 0.697
2020proposed method (deep learning algorithm) proposedmean AUC0.930split: test · subset=independent competition reader-study test set · labeling=consensus of 5 board-certified radiologists · pathologies=5 · sample-size=500 CXR studiesInterpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labels
Source quote
L4: The chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm]
2020MaxAUC proposedAUC0.922split: test · subset=five diseases · evaluation=competition private testing setFast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL Condition
Source quote
L293: It is notable that the current winner~\cite{pham2019interpreting} use all diseases and conditional training that incorporates the hierarchical taxonomy of 14 diseases to train deep networks, and they use an ensemble of 6 networks. In contrast, we only use the 5 diseases and train deep networks for each disease separately without using the domain knowledge. The final results in Table~\ref{table:chexpert} show that our ensemble model by AUC maximization has a better validation AUC than the current winner, and also improves the ensemble of based models trained by Adam by 1% on average. From the table, we also see that our method achieves the highest AUC on Edema, Consolidation, Atelectasis, competitive AUC on Pleural Effusion and slightly worse AUC on Cardiomegaly. On August 4, 2020, we submitted our models (MaxAUC) for evaluation on private testing set and the results ranks 35th on the CheXpert competition with an AUC of 0.922 on private testing set.