CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 6 of 6 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2023CSDA (Ours; full proposed framework with VCQ) proposedAUC0.6792semi-supervised · labeled-samples=500Class-Specific Distribution Alignment for semi-supervised medical image classification
Source quote
L406: Ours │ 0.6499 │ 0.6619 │ 0.6694 │ 0.6762 │ 0.6792
2021S^2MTS^2 proposedMean AUC over 14 disease classes71.58semi-supervised · labeled-data=500 samples per classSelf-supervised Mean Teacher for Semi-supervised Chest X-Ray Classification
Source quote
L219: Ours │ 66.15 │ 67.85 │ 70.83 │ 71.37 │ 71.58 }
2021CheXseg (CAM, p=0.9) proposedmIoU (Avg. IoU across 10 pathologies)0.299split: test · semi-supervised · backbone=ResNet18 · annotated-training-images=200 · pixel-labeled-example-probabilit=0.9CheXseg: Combining Expert Annotations with DNN-generated Saliency Maps for X-ray Segmentation
Source quote
L189: \multirow{2}{*}{Avg. IoU} │ CAM │ 0.163 │ 0.269 │ 0.274 │ 0.273 │ 0.290 │ 0.292 │ 0.299 │ \multirow{2}{*}{0.263}
2021LatentMixing baselineMean AUC over 14 disease classes68.47semi-supervised · labeled-data=500 samples per classSelf-supervised Mean Teacher for Semi-supervised Chest X-Ray Classification
Source quote
L218: LatentMixing \cite{gyawali2020semi} │ 65.12 │ 66.41 │ 67.39 │ 67.96 │ 68.47
2020Input Mixup baselineMean AUROC0.6731split: test · semi-supervised · classes=14 · labeled-samples=300Semi-supervised Medical Image Classification with Global Latent Mixing
Source quote
L359: Input Mixup │ 0.6491 │ 0.6627 │ 0.6731 │ 0.6779 │ 0.6823 │ 0.8504 │ 0.8609 │ 0.9040
2020Latent-space self-ensembling baselineMean AUROC0.6697split: test · semi-supervised · classes=14 · labeled-samples=500Semi-supervised Medical Image Classification with Global Latent Mixing
Source quote
L380: Latent-space self-ensembling │ 0.6200 │ 0.6386 │ 0.6484 │ 0.6637 │ 0.6697