CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 34 of 34 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedCFRT (Classifier Flip Rate along a Trajectory)0.78fine-tuned · trajectory=style · target-attribute=Pleural EffusionLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L101: \multicolumn{1}{c|}{\multirow{2}{*}{CFRT\uparrow}} │ \multirow{2}{*}{0.78} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.89}} │ MEL │ 0.91 │ 0.99 │ 0.59 │ 0.74
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedCFRT (Classifier Flip Rate along a Trajectory)0.89fine-tuned · trajectory=style · target-attribute=Support DevicesLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L101: \multicolumn{1}{c|}{\multirow{2}{*}{CFRT\uparrow}} │ \multirow{2}{*}{0.78} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.89}} │ MEL │ 0.91 │ 0.99 │ 0.59 │ 0.74
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedLPIPS0.24fine-tuned · trajectory=style · target-attribute=Pleural EffusionLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L103: \multicolumn{1}{c|}{\multirow{2}{*}{LPIPS\downarrow}} │ \multirow{2}{*}{0.24} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.05}} │ MEL │ 0.08 │ 0.09 │ 0.12 │ 0.11
2025GLoRIA baselineAverage accuracy50.00%split: test · fine-tuned · tasks=Consolidation; Pleural Effusion · image-view=frontalEnhancing Biomedical Multi-modal Representation Learning with Multi-scale Pre-training and Perturbed Report Discrimination
Source quote
L142: GLoRIA \cite{huang2021gloria} │ 71.11% │ 28.89% │ 50.00%
2025AIMv2 ViT-H baselineROC-AUC0.819fine-tuned · model=AIMv2 · backbone=ViT-HAdvancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation Models
Source quote
L145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815
2025DINOv2 ViT-L baselineROC-AUC0.814fine-tuned · model=DINOv2 · backbone=ViT-LAdvancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation Models
Source quote
L134: ViT-L │ 0.731 │ 0.801 │ 0.814 │ 0.813
2024\imgedit (white-box) proposedEO_p28.5split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024\imgedit (white-box) proposedDI disparity (|1−DI|)25.6split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024\imgedit (white-box) proposedAcc75.1split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024ViT-B baselinemAUC89.3%fine-tuned · backbone=ViT-B/16 · resolution=224×224Learning Low-Rank Feature for Thorax Disease Classification
Source quote
L312: ViT-B \citep{xiao2023delving} │ ViT-B/16 │ 82.7 │ 83.5 │ 89.3
2024BiasAdv baselineEO_p39.0split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L172: BiasAdv~\cite{lim2023biasadv} │ 39.0 │ 54.5 │ 58.2 │ 71.1 │ 36.0 │ 54.0 │ 77.1 │ 61.0 │ 39.0 │ 33.5 │ 36.6 │ 74.9
2024Batch Samp. baselineDI disparity (|1−DI|)51.8split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0
2024Batch Samp. baselineAcc74.3split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC89.24%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023M-FLAG proposedAUC64.4%fine-tuned · labeled-data=1%M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry Optimization
Source quote
L112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7
2023MRM (ViT-B/16) proposedmean AUC88.5%fine-tuned · backbone=ViT-B/16 · labeled-data=1%Advancing Radiograph Representation Learning with Masked Record Modeling
Source quote
L186: Nonetheless, MRM consistently outperforms various baselines on all three datasets under different labeling ratios. Specifically, MRM maintains more advantages over previous pre-training methodologies when fine-tuning with limited annotations, which is quite meaningful for medical image analysis as large amounts of specialist annotations (from radiologists or clinicians) are usually hard to access. It is worth noting that MRM achieves 88.5% when using only 1% labeled data on CheXpert, better than previous counterparts with 100% annotations.
2023Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baselineAUC89.97%split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023Medical-imaging foundation model, CX14 setting baselineRace fairness gap3.09fine-tuned · pretraining-setting=CX14How Fair are Medical Imaging Foundation Models?
Source quote
L196: 3.09
2023Medical-imaging foundation model, CXPT setting baselineRace fairness gap2.85fine-tuned · pretraining-setting=CXPTHow Fair are Medical Imaging Foundation Models?
Source quote
L200: 2.85
2023Medical-imaging foundation model, CX14 + CXPT setting baselineRace fairness gap2.82fine-tuned · pretraining-setting=CX14 + CXPTHow Fair are Medical Imaging Foundation Models?
Source quote
L204: 2.82 mains unclear if this fairness gap stems from the pretraining or fine-tuning stages. In order to decouple the fairness bias from pre-training and fine-tuning, we fine-tune these foundation models on a balanced fine-tuning dataset.
2022MAE-pretrained ViT-S/16 proposedmAUC89.2%split: val · fine-tuned · backbone=ViT-S/16 · resolution=224×224Delving into Masked Autoencoders for Multi-Label Thorax Disease Classification
Source quote
L293: MAE │ ViT-S/16 │ 83.5 │ 81.8 │ 93.5 │ 94.0 │ 93.2 │ 89.2
2022Stable Diffusion fine-tuned for 60k steps at lr 1e-4, with U-Net and text encoder unfrozen (PA training set) proposedPneumothorax class score (Pneux)59.8split: test · fine-tuned · class=Pneumothorax · model=Stable Diffusion · learning-rate=1e-4 · training-steps=60k · unfrozen-components=U-Net and text encoderRoentGen: Vision-Language Foundation Model for Chest X-ray Generation
Source quote
L412: ~ lr 1e-4 │ 50 │ 6.4 │ 59.8 │ 34.4
2022MAE-pretrained DenseNet-121 (DN121)mAUC88.7%split: val · fine-tuned · backbone=DenseNet-121 · resolution=224×224 · source-row-method=MoCo v2Delving into Masked Autoencoders for Multi-Label Thorax Disease Classification
Source quote
L291: \multirow{4}{*}{Ours} │ MoCo v2 │ DN121 │ 78.5 │ 77.9 │ 92.5 │ 92.8 │ 92.7 │ 88.7
2021Equal Loss Train, α=100 proposedAUC0.835split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=male · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Equal Loss Train, α=100 proposedAUC0.819split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=female · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Multi-source model fine-tuned locally proposed non-standard sliceAccuracy94%fine-tuned · class=pneumonia · fine-tuning-samples=80Deep Learning Models May Spuriously Classify Covid-19 from X-ray Images Based on Confounders
Source quote
L195: \multirow{1}{*}{Pneumonia} │ Chexpert │ 12% │ 94%
2020L2TL proposedMean AUC across five classes90.0fine-tuned · backbone=DenseNet-121 · evaluation=ten-crop · ensemble-checkpoints=30Learning to Transfer Learn: Reinforcement Learning-Based Selection for Adaptive Transfer Learning
Source quote
L583: 90.0
2020MoCo-CXR-pretrained end-to-end model (ResNet18) proposedAUC0.813fine-tuned · backbone=ResNet18 · labeled-data-fraction=0.1%MoCo-CXR: MoCo Pretraining Improves Representation and Transferability of Chest X-ray Models
Source quote
L78: We found that MoCo-CXR-pretrained end-to-end models outperform their ImageNet-pretrained counterparts more at small label fractions than at larger label fractions. With the 0.1% label fraction, the ResNet18 MoCo-CXR-pretrained end-to-end model achieved an AUC of 0.813 while the ImageNet-pretrained end-to-end model achieves an AUC of 0.775, yielding a statistically significant AUC improvement of 0.037 (95% CI 0.015, 0.062). The AUC improvement with the 1.0% label fraction was also statistically significant at 0.027 (95% CI 0.006, 0.047). Both pretraining approaches converge to an AUC of 0.942 with the 100% label fraction.
2020C2L (ResNet-18) proposedAverage performance across six classes88.2fine-tuned · backbone=ResNet-18Comparing to Learn: Surpassing ImageNet Pretraining on Radiographs by Comparing Image Representations
Source quote
L199: C2L │ ResNet-18 │ 88.2 │ 81.1 │ 81.4 │ 93.0 │ 92.9 │ 92.6
2020Fine-tuning baselineMean AUC across five classes89.3fine-tuned · backbone=DenseNet-121 · evaluation=ten-crop · ensemble-checkpoints=30Learning to Transfer Learn: Reinforcement Learning-Based Selection for Adaptive Transfer Learning
Source quote
L576: 89.3
2020ImageNet-pretrained end-to-end model (ResNet18) baselineAUC0.775fine-tuned · backbone=ResNet18 · labeled-data-fraction=0.1%MoCo-CXR: MoCo Pretraining Improves Representation and Transferability of Chest X-ray Models
Source quote
L78: We found that MoCo-CXR-pretrained end-to-end models outperform their ImageNet-pretrained counterparts more at small label fractions than at larger label fractions. With the 0.1% label fraction, the ResNet18 MoCo-CXR-pretrained end-to-end model achieved an AUC of 0.813 while the ImageNet-pretrained end-to-end model achieves an AUC of 0.775, yielding a statistically significant AUC improvement of 0.037 (95% CI 0.015, 0.062). The AUC improvement with the 1.0% label fraction was also statistically significant at 0.027 (95% CI 0.006, 0.047). Both pretraining approaches converge to an AUC of 0.942 with the 100% label fraction.
2020ImageNet pretraining (ResNet-18) baselineAverage performance across six classes87.0fine-tuned · backbone=ResNet-18Comparing to Learn: Surpassing ImageNet Pretraining on Radiographs by Comparing Image Representations
Source quote
L197: ImageNet │ ResNet-18 │ 87.0 │ 80.3 │ 79.6 │ 91.9 │ 91.7 │ 91.5
2019Learning to Transfer Learn (L2TL) proposedMean AUC90.0fine-tuned · metric_aggregation=mean AUC over five classes · uncertain_examples=treated as positiveLearning to Transfer Learn
Source quote
L353: Our L2TL │ 86.1 │ 84.4 │ 91.5 │ 94.8 │ 93.2 │ 90.0
2019Fine-tuning baselineMean AUC89.3fine-tuned · metric_aggregation=mean AUC over five classes · uncertain_examples=treated as positiveLearning to Transfer Learn
Source quote
L351: Fine-tuning │ 85.2 │ 83.8 │ 90.0 │ 94.5 │ 92.8 │ 89.3