CheXpert
131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | final model (ensemble of the best performing networks) SOTA frontier | 0.94 | 2021-01-01 | labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensemble · Mean over 5 selected pathologies; validation studies use the majority vote of 3 board… | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteThe chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2 | DenseNet121-MaxAUC | 0.935 | 2023-01-01 | subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGrad · Mean across Cardiomegaly, Edema, Consolidation, Atelectasis, and Pleural Effusion. Ma… | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteDenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935 |
| 3 | FDAM (DenseNet161) (+1 variant) | 0.9333 | 2021-01-01 | K=2; training uses CheXpert and ChestXray8 data. Evaluated on CheXpert validation dat… | Federated Deep AUC Maximization for Hetergeneous Data with a Constant Communication ComplexitySource quote0.9333 |
| 4 | Proposed MARL framework (Ours, ResNet) | 0.925 | 2023-01-01 | backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1 · Validation set; mean over the five competition-task pathologies. Uncertain labels map… | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925 |
| 5 | Proposed instrumental variable learning framework | 0.923 | 2023-01-01 | uncertain-labels=mapped-to-1 · Average across five competition-task pathologies; the evaluation section states uncer… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923 |
Showing 12 of 12 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | GLoRIA baseline | Average accuracy | 50.00% | split: test · fine-tuned · tasks=Consolidation; Pleural Effusion · image-view=frontal | Enhancing Biomedical Multi-modal Representation Learning with Multi-scale Pre-training and Perturbed Report DiscriminationSource quoteL142: GLoRIA \cite{huang2021gloria} │ 71.11% │ 28.89% │ 50.00% |
| 2024 | \imgedit (white-box) proposed | EO_p | 28.5 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | \imgedit (white-box) proposed | DI disparity (|1−DI|) | 25.6 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | \imgedit (white-box) proposed | Acc | 75.1 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | BiasAdv baseline | EO_p | 39.0 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL172: BiasAdv~\cite{lim2023biasadv} │ 39.0 │ 54.5 │ 58.2 │ 71.1 │ 36.0 │ 54.0 │ 77.1 │ 61.0 │ 39.0 │ 33.5 │ 36.6 │ 74.9 |
| 2024 | Batch Samp. baseline | DI disparity (|1−DI|) | 51.8 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0 |
| 2024 | Batch Samp. baseline | Acc | 74.3 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0 |
| 2023 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposed | AUC | 89.24% | split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2023 | Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baseline | AUC | 89.97% | split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2022 | Stable Diffusion fine-tuned for 60k steps at lr 1e-4, with U-Net and text encoder unfrozen (PA training set) proposed | Pneumothorax class score (Pneux) | 59.8 | split: test · fine-tuned · class=Pneumothorax · model=Stable Diffusion · learning-rate=1e-4 · training-steps=60k · unfrozen-components=U-Net and text encoder | RoentGen: Vision-Language Foundation Model for Chest X-ray GenerationSource quoteL412: ~ lr 1e-4 │ 50 │ 6.4 │ 59.8 │ 34.4 |
| 2021 | Equal Loss Train, α=100 proposed | AUC | 0.835 | split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=male · method-setting=Equal Loss Train, α=100 | Technical Challenges for Training Fair Neural NetworksSource quoteL704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016 |
| 2021 | Equal Loss Train, α=100 proposed | AUC | 0.819 | split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=female · method-setting=Equal Loss Train, α=100 | Technical Challenges for Training Fair Neural NetworksSource quoteL704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016 |