CheXpert
131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | final model (ensemble of the best performing networks) SOTA frontier | 0.94 | 2021-01-01 | labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensemble · Mean over 5 selected pathologies; validation studies use the majority vote of 3 board… | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteThe chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2 | DenseNet121-MaxAUC | 0.935 | 2023-01-01 | subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGrad · Mean across Cardiomegaly, Edema, Consolidation, Atelectasis, and Pleural Effusion. Ma… | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteDenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935 |
| 3 | FDAM (DenseNet161) (+1 variant) | 0.9333 | 2021-01-01 | K=2; training uses CheXpert and ChestXray8 data. Evaluated on CheXpert validation dat… | Federated Deep AUC Maximization for Hetergeneous Data with a Constant Communication ComplexitySource quote0.9333 |
| 4 | Proposed MARL framework (Ours, ResNet) | 0.925 | 2023-01-01 | backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1 · Validation set; mean over the five competition-task pathologies. Uncertain labels map… | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925 |
| 5 | Proposed instrumental variable learning framework | 0.923 | 2023-01-01 | uncertain-labels=mapped-to-1 · Average across five competition-task pathologies; the evaluation section states uncer… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923 |
Showing 7 of 7 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2021 | Clustering selection baseline baseline | AUROC | 0.693 | split: test · few-shot · selected-labels=K=10 · condition-subset=non-holdout | MedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement LearningSource quoteL70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}. |
| 2021 | Clustering selection baseline baseline | AUROC | 0.850 | split: test · few-shot · selected-labels=K=10 · condition-subset=holdout: Edema and Atelectasis | MedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement LearningSource quoteL70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}. |
| 2020 | ResNet-18 with weak augmentation, mixup, and confidence tempering (CT) proposed | W-AUC | 0.833 | few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=with | Self-Training with Improved Regularization for Few-Shot Chest X-Ray ClassificationSource quoteL164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations. |
| 2020 | ResNet-18 with weak augmentation, mixup, and confidence tempering (CT) proposed | W-PRC | 0.673 | few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=with | Self-Training with Improved Regularization for Few-Shot Chest X-Ray ClassificationSource quoteL164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations. |
| 2020 | Proposed ResNet-18 with self-training proposed | W-PRC | 0.684 | few-shot · backbone=ResNet-18 · labeled-samples=12500 · unlabeled-samples=15000 | Self-Training with Improved Regularization for Few-Shot Chest X-Ray ClassificationSource quoteL166: Self-training with limited data matches full-shot training. Finally, incorporating the self-training strategy with additional unlabeled data boosts the performance even further. Surprisingly, using less than 10% of the labeled data and 15k unlabeled samples, our approach obtains a W-PRC score of 0.684, outperforming a state-of-the-art ResNet-18 trained on the full 138k set which scores 0.675 (shown by the gray bar versus the first red bar in Fig.~\ref{fig:comparison}). More interestingly, as the number of labeled examples increases, the best performing ResNet-18 model obtained at N-\ell=20000 (\sim 15% of the total labeled data) is comparable to the significantly more complex ResNet-50 and DenseNet-121 models trained on the full data. |
| 2020 | ResNet-18 with weak augmentation and mixup, without confidence tempering ablation | W-AUC | 0.819 | few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=without | Self-Training with Improved Regularization for Few-Shot Chest X-Ray ClassificationSource quoteL164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations. |
| 2020 | ResNet-18 with weak augmentation and mixup, without confidence tempering ablation | W-PRC | 0.64 | few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=without | Self-Training with Improved Regularization for Few-Shot Chest X-Ray ClassificationSource quoteL164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations. |