CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 3 of 3 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2020ResNet-18 with weak augmentation, mixup, and confidence tempering (CT) proposedW-AUC0.833few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=withSelf-Training with Improved Regularization for Few-Shot Chest X-Ray Classification
Source quote
L164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations.
2020ResNet-18 with weak augmentation, mixup, and confidence tempering (CT) proposedW-PRC0.673few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=withSelf-Training with Improved Regularization for Few-Shot Chest X-Ray Classification
Source quote
L164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations.
2020Proposed ResNet-18 with self-training proposedW-PRC0.684few-shot · backbone=ResNet-18 · labeled-samples=12500 · unlabeled-samples=15000Self-Training with Improved Regularization for Few-Shot Chest X-Ray Classification
Source quote
L166: Self-training with limited data matches full-shot training. Finally, incorporating the self-training strategy with additional unlabeled data boosts the performance even further. Surprisingly, using less than 10% of the labeled data and 15k unlabeled samples, our approach obtains a W-PRC score of 0.684, outperforming a state-of-the-art ResNet-18 trained on the full 138k set which scores 0.675 (shown by the gray bar versus the first red bar in Fig.~\ref{fig:comparison}). More interestingly, as the number of labeled examples increases, the best performing ResNet-18 model obtained at N-\ell=20000 (\sim 15% of the total labeled data) is comparable to the significantly more complex ResNet-50 and DenseNet-121 models trained on the full data.