CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 29 of 29 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MedCLIP + GazeWorld proposedAccuracy59.420-shot · subset=5×200A World Model of Radiologist Reading for Medical Image Representation Learning
Source quote
L682: 58.13 │ 59.42 │ 56.85
2026Full (Graph-of-Differences) proposedR1↑ (Rank-1)0.33590-shot · evaluation=external-transferGraph-of-Differences: Anatomy-Structured Difference Alignment for Medical Image Re-Identification
Source quote
L232: 0.9033 │ 0.8294 │ 0.3359 │ 0.3926
2025Autonomous distillation proposedAUC0.920-shotTurning Drift into Constraint: Robust Reasoning Alignment in Non-Stationary Multi-Stream Environments
Source quote
L271: CARZero │ 0.84 │ 0.81 │ 0.92 │ 0.80 {\color[HTML]{FF0000} Ours} │ {\color[HTML]{FF0000} 0.85} │ {\color[HTML]{FF0000} 0.83} │ {\color[HTML]{FF0000} 0.92} │ {\color[HTML]{FF0000} 0.81} }
2025MedImageInsight zero-shot proposedAcc80.5%0-shot · prompt=ImpressionBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62).
2025MedImageInsight zero-shot proposedMCC0.620-shot · prompt=ImpressionBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62).
2025MedImageInsight zero-shot ensemble proposedAbsolute MCC difference across race subgroups10%0-shot · method=zero-shot ensemble · subgroup=raceBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L419: Figure 3 (right) illustrates the absolute MCC differences across the demographic subgroups, sex, age, and race, in the CheXpert dataset. All evaluated methods exhibited varying levels of bias, reflected in performance differences across subgroups. ZS ensembling demonstrated a notable bias reduction compared to linear probing across all variables. For linear probing, differences ranged from 10% for sex, 14% for race, and up to 24% for age. In contrast, the ZS ensemble method achieved considerably lower bias levels, with the highest observed difference of 10% for race, while bias for sex and age remained below 5%. Although the ZS performance method demonstrated improved fairness compared to linear probing, methods such as LORA and KNN exhibited even smaller differences across all variables.
2025ALTA proposedAccuracy56.6%0-shot · subset=5×200 · resolution=224Efficient Medical Vision-Language Alignment Through Adapting Masked Vision Models
Source quote
L286: Our ALTA │ 224 │ 83.2 │ 77.9 │ 91.0 │ 56.6
2025CLIP fine-tuned with Palm2-bison fine-grained captions proposedaverage per-class accuracy (Avg)72.5%0-shot · backbone=CLIP · caption-source=Palm2-bison · caption-granularity=fineEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L116: Palm2-bison~\cite{anil2023palm} │ fine │ 74.6 │ 70.7 │ 72.4 │ 77.6 │ 56.9 │ 84.5 │ 70.3 │ 80.2 │ 93.1 │ 37.1 │ 79.7 │ 72.5
2025CLIP fine-tuned with Zephyr-7b coarse-grained captions proposedaverage per-class accuracy (Avg)53.2%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=coarseEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L127: coarse │ 65.9 │ 41.8 │ 78.9 │ 56.9 │ 42.7 │ 85.8 │ 49.1 │ 71.6 │ 85.8 │ 3.4 │ 3.4 │ 53.2
2025CLIP fine-tuned with Zephyr-7b medium-grained captions proposedaverage per-class accuracy (Avg)56.8%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=mediumEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L126: medium │ 66.4 │ 40.5 │ 82.8 │ 81.5 │ 48.7 │ 85.3 │ 46.1 │ 71.6 │ 85.3 │ 3.9 │ 12.9 │ 56.8
2025CLIP fine-tuned with Zephyr-7b fine-grained captions proposedaverage per-class accuracy (Avg)64.1%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=fineEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L125: \multirow[t]{3}{*}{zephyr-7b~\cite{tunstall2023zephyr}} │ fine │ 67.7 │ 43.1 │ 60.3 │ 60.3 │ 56.5 │ 83.2 │ 78.4 │ 79.3 │ 86.2 │ 62.5 │ 28.0 │ 64.1
2025AdvSimplex (Medical CLIP, CheXzero paradigm, ViT-B) proposed non-standard slicePGD AUC0.7350-shot · attack=PGD-20 · epsilon=1/255 · backbone=ViT-BImproving Zero-Shot Adversarial Robustness in Vision-Language Models by Closed-form Alignment of Adversarial Path Simplices
Source quote
L1165: 0.735
2025CLIP fine-tuned using Human Expert captions baselineaverage per-class accuracy (Avg)49.9%0-shot · backbone=CLIP · caption-source=Human ExpertEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L115: Human Expert~\cite{johnson2019mimiccxrjpg} │ 34.5 │ 29.3 │ 64.2 │ 54.7 │ 54.3 │ 56.0 │ 66.8 │ 65.9 │ 44.8 │ 39.7 │ 39.2 │ 49.9
2024HybridMED proposedAcc0.4480-shot · subset=5×200 · pretraining-dataset=MIMIC-CXRAdvancing Medical Radiograph Representation Learning: A Hybrid Pre-training Paradigm with Multilevel Semantic Granularity
Source quote
L201: Ours │ MIMIC-CXR │ 0.800 │ 0.448
2024EGMA proposedAcc.60.500-shot · subset=5x200Eye-gaze Guided Multi-modal Alignment for Medical Representation Learning
Source quote
L293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46
2024EGMA proposedF158.440-shot · subset=5x200Eye-gaze Guided Multi-modal Alignment for Medical Representation Learning
Source quote
L293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46
2024MedPrompt-ViT proposedzero-shot image classification performance0.62200-shot · prompt=automatically generated · subset=five held-out classes · backbone=ViTExploring Low-Resource Medical Image Classification with Weakly Supervised Prompt Learning
Source quote
L201: MedPrompt-ViT (Ours) │ 0.6220 │ 0.5720 │ 0.7997 │ 0.7284
2024UniMed-CLIP proposed non-standard sliceACC65.900-shot · subset=5x200 · backbone=CLIPUniMed-CLIP: Towards a Unified Image-Text Pretraining Paradigm for Diverse Medical Imaging Modalities
Source quote
L463: UniMed-CLIP │ 65.90 │ 71.65 │ 71.35 │ 66.31 │ 85.82 │ 85.27 │ 37.54 │ 24.43 │ 31.72
2024MMCLIP baselineAUC90.53split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L262: MMCLIP │ 90.53 │ 67.05 │ 86.04 │ 85.79 │ 33.50 │ 91.19 │ 86.16 │ 62.57 │ 80.46
2024MedKlip baselineAUC89.97split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L260: MedKlip \cite{wu2023medklip} │ 89.97 │ 63.67 │ 84.32 │ 84.97 │ 35.17 │ 90.68 │ 86.94 │ 63.42 │ 80.02
2024MedCLIP-ViT baselinezero-shot image classification performance0.59420-shot · prompt=manual prompt ensemble · backbone=ViTExploring Low-Resource Medical Image Classification with Weakly Supervised Prompt Learning
Source quote
L200: MedCLIP-ViT \cite{7} │ 0.5942 │ 0.5024 │ 0.7943 │ 0.7682
2023ELIXR-C proposedMean AUC0.850split: test · 0-shot · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L434: 0.850
2023PRIOR proposedAccuracy34.900-shot · subset=5x200 · ensemble=none · prompting=simple prompt engineeringPRIOR: Prototype Representation Joint Learning from Medical Images and Reports
Source quote
L211: PRIOR (ours) │ \textcolor{red}{\bf{34.90}} │ \textcolor{red}{\bf{30.56}} │ \textcolor{blue}{35.88}
2023KAD proposedMatthews Correlation Coefficient (MCC)0.613split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.666split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.702split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023CheXzero ensemble baselineMean AUC0.838split: test · 0-shot · method=CheXzero ensemble · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L431: 0.838
2023GLoRIA baselineAccuracy23.200-shot · subset=5x200 · ensemble=none · prompting=simple prompt engineeringPRIOR: Prototype Representation Joint Learning from Medical Images and Reports
Source quote
L210: GLoRIA \cite{huang2021gloria} │ \textcolor{blue}{23.20} │ 15.79 │ \textcolor{red}{\bf{44.01}}
2023Three radiologists (mean) baselineMatthews Correlation Coefficient (MCC)0.507split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.