CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024MMCLIP baselineAUC90.53split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L262: MMCLIP │ 90.53 │ 67.05 │ 86.04 │ 85.79 │ 33.50 │ 91.19 │ 86.16 │ 62.57 │ 80.46
2024MedKlip baselineAUC89.97split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L260: MedKlip \cite{wu2023medklip} │ 89.97 │ 63.67 │ 84.32 │ 84.97 │ 35.17 │ 90.68 │ 86.94 │ 63.42 │ 80.02
2023ELIXR-C proposedMean AUC0.850split: test · 0-shot · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L434: 0.850
2023KAD proposedMatthews Correlation Coefficient (MCC)0.613split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.666split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.702split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023CheXzero ensemble baselineMean AUC0.838split: test · 0-shot · method=CheXzero ensemble · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L431: 0.838
2023Three radiologists (mean) baselineMatthews Correlation Coefficient (MCC)0.507split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.