| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | final model (ensemble of the best performing networks) SOTA frontier | 0.94 | 2021-01-01 | labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensemble · Mean over 5 selected pathologies; validation studies use the majority vote of 3 board… | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteThe chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2 | DenseNet121-MaxAUC | 0.935 | 2023-01-01 | subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGrad · Mean across Cardiomegaly, Edema, Consolidation, Atelectasis, and Pleural Effusion. Ma… | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteDenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935 |
| 3 | FDAM (DenseNet161) (+1 variant) | 0.9333 | 2021-01-01 | K=2; training uses CheXpert and ChestXray8 data. Evaluated on CheXpert validation dat… | Federated Deep AUC Maximization for Hetergeneous Data with a Constant Communication ComplexitySource quote0.9333 |
| 4 | Proposed MARL framework (Ours, ResNet) | 0.925 | 2023-01-01 | backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1 · Validation set; mean over the five competition-task pathologies. Uncertain labels map… | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925 |
| 5 | Proposed instrumental variable learning framework | 0.923 | 2023-01-01 | uncertain-labels=mapped-to-1 · Average across five competition-task pathologies; the evaluation section states uncer… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923 |
Showing 56 of 56 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.487 | split: test | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL307: both models (0.487 and 0.536, with intervals including 0.5). |
| 2026 | Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.536 | split: test · backbone=ViT-B/16 | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL307: both models (0.487 and 0.536, with intervals including 0.5). |
| 2026 | No Adapt. baseline | mean AUROC | 76.0 | Main results table; seventh value in the target-domain block (aggregate). | Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray DiagnosisSource quoteL139: No Adapt. │ 56.6 │ 62.3 │ 67.4 │ 67.4 │ 64.1 │ 69.7 │ 64.6 │ 74.3 │ 71.7 │ 79.4 │ 80.8 │ 71.2 │ 78.3 │ 76.0 |
| 2026 | TENT baseline | mean AUROC | 77.4 | split: test · test-time-adaptation | Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray DiagnosisSource quoteL141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4 |
| 2025 | Synthetic+Real mix model proposed | AUROC | 0.730 | split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained · evaluation-view=PA | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733), |
| 2025 | XFMamba-S (frontal and lateral; cross-fusion; CVSM and MVCM enabled) proposed | AUROC | 0.9184 | views=frontal-and-lateral · epochs=100 · fusion=cross-fusion · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL130: 8 │ Frontal \ │ Lateral │ cross-fusion │ \usym{2713} │ \usym{2713} │ 0.9184 |
| 2025 | EWC-Guided Diffusion Replay (DDPM+EWC) proposed | AUROC | 0.851 | split: val | EWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical ImagingSource quoteL4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models. |
| 2025 | XFMamba-S (frontal and lateral; early fusion) ablation | AUROC | 0.9090 | views=frontal-and-lateral · epochs=100 · fusion=early-fusion · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL125: 3 │ Frontal \ │ Lateral │ early-fusion │ \usym{2717} │ \usym{2717} │ 0.9090 |
| 2025 | XFMamba-S (frontal and lateral; late fusion) ablation | AUROC | 0.9092 | views=frontal-and-lateral · epochs=100 · fusion=late-fusion · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL126: 4 │ Frontal \ │ Lateral │ late-fusion │ \usym{2717} │ \usym{2717} │ 0.9092 |
| 2025 | XFMamba-S (lateral view only; no fusion) ablation | AUROC | 0.8961 | views=lateral-only · epochs=100 · fusion=none · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL123: 1 │ Lateral │ no │ \usym{2717} │ \usym{2717} │ 0.8961 |
| 2025 | XFMamba-S (frontal view only; no fusion) ablation | AUROC | 0.9081 | views=frontal-only · epochs=100 · fusion=none · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL124: 2 │ Frontal │ no │ \usym{2717} │ \usym{2717} │ 0.9081 |
| 2025 | Backbone score correlation (ordinary vs. soft metrics) | R² of Pearson correlation between ordinary and soft AUROC scores | 0.465 | label=Pneumothorax · comparison=ordinary-versus-soft AUROC across backbones | Clinical Uncertainty Impacts Machine Learning EvaluationsSource quoteL169: The analysis of the coefficients of determination R^2 in Figure~\ref{fig:DatasetAnalysis} shows that \gls*{ap} often decouples rankings between ordinary and soft settings moderately, and \gls*{auroc} can sometimes decouple them sharply (e.g., CheXpert--Pneumothorax AUROC R (2)\!=\!0.465 vs.\ AP R (2)\!=\!0.983). |
| 2025 | Joint training | AUROC | 0.869 | Macro-averaged across five standard diagnosis labels; 95% CIs across 5 independent runs… | EWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical ImagingSource quoteL4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models. |
| 2025 | Real-only baseline baseline | AUROC | 0.700 | split: test · training-data=66k real MIMIC-CXR images · initialization=ImageNet-pretrained · evaluation-view=PA | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733), |
| 2025 | EfficientNet-b0 baseline | AUROC | 0.752 | label=Cardiomegaly · backbone=EfficientNet-b0 · metric-setting=ordinary | Clinical Uncertainty Impacts Machine Learning EvaluationsSource quoteL358: EfficientNet-b0 │ 0.752 │ 0.531 │ 0.683 │ 0.480 |
| 2025 | VGG-16 baseline | s-AUROC | 0.694 | label=Cardiomegaly · backbone=VGG-16 · metric-setting=soft | Clinical Uncertainty Impacts Machine Learning EvaluationsSource quoteL360: VGG-16 │ 0.717 │ 0.493 │ 0.694 │ 0.491 |
| 2025 | AIMv2 ViT-H baseline | ROC-AUC | 0.819 | fine-tuned · model=AIMv2 · backbone=ViT-H | Advancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation ModelsSource quoteL145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815 |
| 2025 | DINOv2 ViT-L baseline | ROC-AUC | 0.814 | fine-tuned · model=DINOv2 · backbone=ViT-L | Advancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation ModelsSource quoteL134: ViT-L │ 0.731 │ 0.801 │ 0.814 │ 0.813 |
| 2025 | AIMv2 ViT-H baseline | ROC-AUC | 0.731 | linear-probe · model=AIMv2 · backbone=ViT-H | Advancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation ModelsSource quoteL145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815 |
| 2024 | MSN+x-SM | AUROC | 0.766 | split: test · linear-probe · backbone=ViT-T | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL550: MSN+ x-SM │ 0.766 (0.745, 0.786) \color{green}\uparrow\uparrow │ 0.402 (0.387, 0.427) \color{green}\uparrow │ \color{blue}{0.716^* (0.712, 0.719)} \color{green}\uparrow\uparrow │ \color{blue}{0.241^* (0.236, 0.249)} \color{green}\uparrow\uparrow |
| 2024 | MSN baseline | AUROC | 0.740 | split: test · linear-probe · backbone=ViT-T | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL534: MSN │ 0.740 (0.720, 0.763) │ 0.396 (0.382, 0.421) │ 0.676 (0.671, 0.68) │ 0.199 (0.197, 0.203) |
| 2024 | MINE baseline | AUROC | 87.7 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=inverted | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4 |
| 2024 | Rebalance baseline | AUROC | 79.8 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=inverted | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8 |
| 2024 | MINE baseline | AUROC | 92.4 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balanced | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4 |
| 2024 | Rebalance baseline | AUROC | 90.0 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balanced | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8 |
| 2024 | Previous image baseline non-standard slice | macro-average AUROC | 0.572 | split: test · subset=Diff subset | Towards Predicting Temporal Changes in a Patient's Chest X-ray Images based on Electronic Health RecordsSource quoteL482: Previous image │ 0.768 │ 0.846 │ 0.572 |
| 2023 | PTUnifier proposed | AUROC | 90.1 | split: val | Towards Unifying Medical Vision-and-Language Pre-training via Soft PromptsSource quoteL288: \multirow{-3}{*}{Study_2} │ 88.1 │ 88.6 │ 77.8 │ 45.1 │ 10.5 │ 14.5 │ 11.3 │ 72.0 │ 77.9 PTUnifier (ours) │ 90.1 │ 90.6 │ 80.0 │ 46.2 │ 10.7 │ 21.0 │ 20.8 │ 78.3 │ 85.2 │ 79.3 }} |
| 2023 | ShorT (binary race prediction head) proposed | Two-sided Spearman rank correlation (race-prediction AUROC vs equalized odds) | 0.469 | target=cardiomegaly · attribute=binary-race | Detecting shortcut learning for fair medical AI using shortcut testingSource quoteL64: Using the public dataset CheXpert20, we predicted cardiomegaly from chest x-rays as a binary outcome. Following the work in Gichoya et al.13, we investigated whether the representation of race (self-reported binary attribute, Black or White) led to shortcutting in our model. Our results showed that shortcutting was present (⍴=0.469, p<0.001, Figure 5), with fairness (here estimated via equalized odds) depending strongly on the model’s encoding of race (estimated by the AUROC of race prediction). Contrary to the biased dataset for Effusion, we however note that there is no apparent trade-off between the model’s clinical performance and |
| 2023 | Adapter (ConvNeXt-T) baseline | AUROC | 86.77 | epochs=10 · backbone=ConvNeXt-T · pretraining=IN-21k then IN-1k · privacy-delta=10^-5 · privacy-epsilon=1 | Differentially Private Video Activity RecognitionSource quoteL403: Adapter │ 1.7M │ IN-21k \rightarrow IN-1k │ 86.77 │ 87.06 │ 87.78 │ 88.05 |
| 2023 | Selective fine-tune (ConvNeXt-T) baseline | AUROC | 85.06 | epochs=10 · backbone=ConvNeXt-T · pretraining=IN-21k then IN-1k · privacy-delta=10^-5 · privacy-epsilon=1 | Differentially Private Video Activity RecognitionSource quoteL401: Selective fine-tune │ 20.2K │ IN-21k \rightarrow IN-1k │ 85.06 │ 85.29 │ 85.92 │ 86.56 |
| 2022 | HeartSpot MP+HLine with DenseNet121 proposed | ROC AUC | .84 | split: test · backbone=DenseNet121 · resolution=320×320 · compression=MP+HLine | HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly DetectionSource quoteL123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline. |
| 2022 | HeartSpot MP+HLine with DenseNet121 proposed | ROC AUC improvement | +0.01 | split: test · backbone=DenseNet121 · comparison=baseline DenseNet121 · compression=MP+HLine | HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly DetectionSource quoteL123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline. |
| 2022 | Label-Supervised baseline | AUROC | 78.90 | split: val | Breaking with Fixed Set Pathology Recognition through Report-Guided Contrastive TrainingSource quoteL206: Label-Supervised │ 77.26 │ 77.42 │ 78.90 │ 79.70 │ 76.47 |
| 2021 | GAN-based augmentation proposed | AUC (ROC-AUC) | 0.758 | split: val · 1-data · pathology=Lung Lesion | GAN-based Data Augmentation for Chest X-ray ClassificationSource quoteL106: Lung Lesion │ 0.727 │ 0.728 │ 0.758 |
| 2021 | GAN-based augmentation proposed | AUC (ROC-AUC) | 0.594 | split: val · 1-data · pathology=Pleural Other | GAN-based Data Augmentation for Chest X-ray ClassificationSource quoteL107: 1% │ Pleural Other │ 0.566 │ 0.550 │ 0.594 |
| 2021 | GAN-based augmentation proposed | AUC (ROC-AUC) | 0.656 | split: val · 1-data · pathology=Fracture | GAN-based Data Augmentation for Chest X-ray ClassificationSource quoteL108: Fracture │ 0.583 │ 0.601 │ 0.656 |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.892 | split: test · disease=Pleural Effusion · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.961 | split: test · disease=Consolidation · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.924 | split: test · disease=Edema · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | ODIN (pert. only) ablation | OOD AUROC | 0.841 | setting=1 · variant=perturbation-only · backbone=WRN-100x2 · ID-classes=Cardiomegaly, Pneumothorax · OOD-classes=Fracture | Confidence-Based Out-of-Distribution Detection: A Comparative Study and AnalysisSource quoteL147: ODIN (pert. only) │ 0.841 │ 0.819 │ 0.888 │ 0.865 │ 0.856 │ 0.757 |
| 2021 | ODIN (temp. only) ablation | OOD AUROC | 0.678 | setting=1 · variant=temperature-only · backbone=WRN-100x2 · ID-classes=Cardiomegaly, Pneumothorax · OOD-classes=Fracture | Confidence-Based Out-of-Distribution Detection: A Comparative Study and AnalysisSource quoteL148: ODIN (temp. only) │ 0.678 │ 0.695 │ 0.888 │ 0.444 │ 0.575 │ 0.757 |
| 2021 | ODIN (pert. only) ablation | OOD AUROC | 0.865 | setting=2 · variant=perturbation-only · backbone=WRN-100x2 · ID-classes=Lung Opacity, Pleural Effusion · OOD-classes=Fracture, Pneumonia | Confidence-Based Out-of-Distribution Detection: A Comparative Study and AnalysisSource quoteL147: ODIN (pert. only) │ 0.841 │ 0.819 │ 0.888 │ 0.865 │ 0.856 │ 0.757 |
| 2021 | ODIN (temp. only) ablation | OOD AUROC | 0.444 | setting=2 · variant=temperature-only · backbone=WRN-100x2 · ID-classes=Lung Opacity, Pleural Effusion · OOD-classes=Fracture, Pneumonia | Confidence-Based Out-of-Distribution Detection: A Comparative Study and AnalysisSource quoteL148: ODIN (temp. only) │ 0.678 │ 0.695 │ 0.888 │ 0.444 │ 0.575 │ 0.757 |
| 2021 | No augmentation baseline | AUC (ROC-AUC) | 0.727 | split: val · 1-data · pathology=Lung Lesion | GAN-based Data Augmentation for Chest X-ray ClassificationSource quoteL106: Lung Lesion │ 0.727 │ 0.728 │ 0.758 |
| 2021 | No augmentation baseline | AUC (ROC-AUC) | 0.566 | split: val · 1-data · pathology=Pleural Other | GAN-based Data Augmentation for Chest X-ray ClassificationSource quoteL107: 1% │ Pleural Other │ 0.566 │ 0.550 │ 0.594 |
| 2021 | No augmentation baseline | AUC (ROC-AUC) | 0.583 | split: val · 1-data · pathology=Fracture | GAN-based Data Augmentation for Chest X-ray ClassificationSource quoteL108: Fracture │ 0.583 │ 0.601 │ 0.656 |
| 2021 | ODIN baseline | OOD AUROC | 0.841 | setting=1 · backbone=WRN-100x2 · ID-classes=Cardiomegaly, Pneumothorax · OOD-classes=Fracture | Confidence-Based Out-of-Distribution Detection: A Comparative Study and AnalysisSource quoteL146: ODIN │ 0.841 │ 0.819 │ 0.888 │ 0.862 │ 0.856 │ 0.758 |
| 2021 | ODIN baseline | OOD AUROC | 0.862 | setting=2 · backbone=WRN-100x2 · ID-classes=Lung Opacity, Pleural Effusion · OOD-classes=Fracture, Pneumonia | Confidence-Based Out-of-Distribution Detection: A Comparative Study and AnalysisSource quoteL146: ODIN │ 0.841 │ 0.819 │ 0.888 │ 0.862 │ 0.856 │ 0.758 |
| 2021 | Clustering selection baseline baseline | AUROC | 0.693 | split: test · few-shot · selected-labels=K=10 · condition-subset=non-holdout | MedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement LearningSource quoteL70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}. |
| 2021 | Clustering selection baseline baseline | AUROC | 0.850 | split: test · few-shot · selected-labels=K=10 · condition-subset=holdout: Edema and Atelectasis | MedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement LearningSource quoteL70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}. |
| 2020 | CAN proposed | Average AUROC | 0.768 | views=frontal-only · labels=14-label · uncertain-labels=U-Ones | Multi-label Thoracic Disease Image Classification with Cross-Attention NetworksSource quoteL160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775 |
| 2020 | CAN proposed | Average AUROC | 0.775 | views=frontal-and-lateral-equally · labels=14-label · uncertain-labels=U-Ones | Multi-label Thoracic Disease Image Classification with Cross-Attention NetworksSource quoteL160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775 |
| 2020 | Input Mixup baseline | Mean AUROC | 0.6731 | split: test · semi-supervised · classes=14 · labeled-samples=300 | Semi-supervised Medical Image Classification with Global Latent MixingSource quoteL359: Input Mixup │ 0.6491 │ 0.6627 │ 0.6731 │ 0.6779 │ 0.6823 │ 0.8504 │ 0.8609 │ 0.9040 |
| 2020 | Latent-space self-ensembling baseline | Mean AUROC | 0.6697 | split: test · semi-supervised · classes=14 · labeled-samples=500 | Semi-supervised Medical Image Classification with Global Latent MixingSource quoteL380: Latent-space self-ensembling │ 0.6200 │ 0.6386 │ 0.6484 │ 0.6637 │ 0.6697 |
| 2020 | CheXNet baseline | Average AUROC | 0.734 | views=frontal-only · labels=14-label · uncertain-labels=U-Ones | Multi-label Thoracic Disease Image Classification with Cross-Attention NetworksSource quoteL160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775 |
| 2020 | CheXNet baseline | Average AUROC | 0.746 | views=frontal-and-lateral-equally · labels=14-label · uncertain-labels=U-Ones | Multi-label Thoracic Disease Image Classification with Cross-Attention NetworksSource quoteL160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775 |