CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 56 of 56 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard sliceAUROCf (failure-detection AUROC)0.487split: testCan saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L307: both models (0.487 and 0.536, with intervals including 0.5).
2026Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard sliceAUROCf (failure-detection AUROC)0.536split: test · backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L307: both models (0.487 and 0.536, with intervals including 0.5).
2026No Adapt. baselinemean AUROC76.0Main results table; seventh value in the target-domain block (aggregate).Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray Diagnosis
Source quote
L139: No Adapt. │ 56.6 │ 62.3 │ 67.4 │ 67.4 │ 64.1 │ 69.7 │ 64.6 │ 74.3 │ 71.7 │ 79.4 │ 80.8 │ 71.2 │ 78.3 │ 76.0
2026TENT baselinemean AUROC77.4split: test · test-time-adaptationLeveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray Diagnosis
Source quote
L141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4
2025Synthetic+Real mix model proposedAUROC0.730split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained · evaluation-view=PAImproving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic Data
Source quote
L139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733),
2025XFMamba-S (frontal and lateral; cross-fusion; CVSM and MVCM enabled) proposedAUROC0.9184views=frontal-and-lateral · epochs=100 · fusion=cross-fusion · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L130: 8 │ Frontal \ │ Lateral │ cross-fusion │ \usym{2713} │ \usym{2713} │ 0.9184
2025EWC-Guided Diffusion Replay (DDPM+EWC) proposedAUROC0.851split: valEWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical Imaging
Source quote
L4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models.
2025XFMamba-S (frontal and lateral; early fusion) ablationAUROC0.9090views=frontal-and-lateral · epochs=100 · fusion=early-fusion · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L125: 3 │ Frontal \ │ Lateral │ early-fusion │ \usym{2717} │ \usym{2717} │ 0.9090
2025XFMamba-S (frontal and lateral; late fusion) ablationAUROC0.9092views=frontal-and-lateral · epochs=100 · fusion=late-fusion · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L126: 4 │ Frontal \ │ Lateral │ late-fusion │ \usym{2717} │ \usym{2717} │ 0.9092
2025XFMamba-S (lateral view only; no fusion) ablationAUROC0.8961views=lateral-only · epochs=100 · fusion=none · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L123: 1 │ Lateral │ no │ \usym{2717} │ \usym{2717} │ 0.8961
2025XFMamba-S (frontal view only; no fusion) ablationAUROC0.9081views=frontal-only · epochs=100 · fusion=none · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L124: 2 │ Frontal │ no │ \usym{2717} │ \usym{2717} │ 0.9081
2025Backbone score correlation (ordinary vs. soft metrics)R² of Pearson correlation between ordinary and soft AUROC scores0.465label=Pneumothorax · comparison=ordinary-versus-soft AUROC across backbonesClinical Uncertainty Impacts Machine Learning Evaluations
Source quote
L169: The analysis of the coefficients of determination R^2 in Figure~\ref{fig:DatasetAnalysis} shows that \gls*{ap} often decouples rankings between ordinary and soft settings moderately, and \gls*{auroc} can sometimes decouple them sharply (e.g., CheXpert--Pneumothorax AUROC R (2)\!=\!0.465 vs.\ AP R (2)\!=\!0.983).
2025Joint trainingAUROC0.869Macro-averaged across five standard diagnosis labels; 95% CIs across 5 independent runs…EWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical Imaging
Source quote
L4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models.
2025Real-only baseline baselineAUROC0.700split: test · training-data=66k real MIMIC-CXR images · initialization=ImageNet-pretrained · evaluation-view=PAImproving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic Data
Source quote
L139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733),
2025EfficientNet-b0 baselineAUROC0.752label=Cardiomegaly · backbone=EfficientNet-b0 · metric-setting=ordinaryClinical Uncertainty Impacts Machine Learning Evaluations
Source quote
L358: EfficientNet-b0 │ 0.752 │ 0.531 │ 0.683 │ 0.480
2025VGG-16 baselines-AUROC0.694label=Cardiomegaly · backbone=VGG-16 · metric-setting=softClinical Uncertainty Impacts Machine Learning Evaluations
Source quote
L360: VGG-16 │ 0.717 │ 0.493 │ 0.694 │ 0.491
2025AIMv2 ViT-H baselineROC-AUC0.819fine-tuned · model=AIMv2 · backbone=ViT-HAdvancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation Models
Source quote
L145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815
2025DINOv2 ViT-L baselineROC-AUC0.814fine-tuned · model=DINOv2 · backbone=ViT-LAdvancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation Models
Source quote
L134: ViT-L │ 0.731 │ 0.801 │ 0.814 │ 0.813
2025AIMv2 ViT-H baselineROC-AUC0.731linear-probe · model=AIMv2 · backbone=ViT-HAdvancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation Models
Source quote
L145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815
2024MSN+x-SMAUROC0.766split: test · linear-probe · backbone=ViT-TMulti-modal Masked Siamese Network Improves Chest X-Ray Representation Learning
Source quote
L550: MSN+ x-SM │ 0.766 (0.745, 0.786) \color{green}\uparrow\uparrow │ 0.402 (0.387, 0.427) \color{green}\uparrow │ \color{blue}{0.716^* (0.712, 0.719)} \color{green}\uparrow\uparrow │ \color{blue}{0.241^* (0.236, 0.249)} \color{green}\uparrow\uparrow
2024MSN baselineAUROC0.740split: test · linear-probe · backbone=ViT-TMulti-modal Masked Siamese Network Improves Chest X-Ray Representation Learning
Source quote
L534: MSN │ 0.740 (0.720, 0.763) │ 0.396 (0.382, 0.421) │ 0.676 (0.671, 0.68) │ 0.199 (0.197, 0.203)
2024MINE baselineAUROC87.7split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=invertedBenchmarking Dependence Measures to Prevent Shortcut Learning in Medical Imaging
Source quote
L157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4
2024Rebalance baselineAUROC79.8split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=invertedBenchmarking Dependence Measures to Prevent Shortcut Learning in Medical Imaging
Source quote
L156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8
2024MINE baselineAUROC92.4split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balancedBenchmarking Dependence Measures to Prevent Shortcut Learning in Medical Imaging
Source quote
L157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4
2024Rebalance baselineAUROC90.0split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balancedBenchmarking Dependence Measures to Prevent Shortcut Learning in Medical Imaging
Source quote
L156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8
2024Previous image baseline non-standard slicemacro-average AUROC0.572split: test · subset=Diff subsetTowards Predicting Temporal Changes in a Patient's Chest X-ray Images based on Electronic Health Records
Source quote
L482: Previous image │ 0.768 │ 0.846 │ 0.572
2023PTUnifier proposedAUROC90.1split: valTowards Unifying Medical Vision-and-Language Pre-training via Soft Prompts
Source quote
L288: \multirow{-3}{*}{Study_2} │ 88.1 │ 88.6 │ 77.8 │ 45.1 │ 10.5 │ 14.5 │ 11.3 │ 72.0 │ 77.9 PTUnifier (ours) │ 90.1 │ 90.6 │ 80.0 │ 46.2 │ 10.7 │ 21.0 │ 20.8 │ 78.3 │ 85.2 │ 79.3 }}
2023ShorT (binary race prediction head) proposedTwo-sided Spearman rank correlation (race-prediction AUROC vs equalized odds)0.469target=cardiomegaly · attribute=binary-raceDetecting shortcut learning for fair medical AI using shortcut testing
Source quote
L64: Using the public dataset CheXpert20, we predicted cardiomegaly from chest x-rays as a binary outcome. Following the work in Gichoya et al.13, we investigated whether the representation of race (self-reported binary attribute, Black or White) led to shortcutting in our model. Our results showed that shortcutting was present (⍴=0.469, p<0.001, Figure 5), with fairness (here estimated via equalized odds) depending strongly on the model’s encoding of race (estimated by the AUROC of race prediction). Contrary to the biased dataset for Effusion, we however note that there is no apparent trade-off between the model’s clinical performance and
2023Adapter (ConvNeXt-T) baselineAUROC86.77epochs=10 · backbone=ConvNeXt-T · pretraining=IN-21k then IN-1k · privacy-delta=10^-5 · privacy-epsilon=1Differentially Private Video Activity Recognition
Source quote
L403: Adapter │ 1.7M │ IN-21k \rightarrow IN-1k │ 86.77 │ 87.06 │ 87.78 │ 88.05
2023Selective fine-tune (ConvNeXt-T) baselineAUROC85.06epochs=10 · backbone=ConvNeXt-T · pretraining=IN-21k then IN-1k · privacy-delta=10^-5 · privacy-epsilon=1Differentially Private Video Activity Recognition
Source quote
L401: Selective fine-tune │ 20.2K │ IN-21k \rightarrow IN-1k │ 85.06 │ 85.29 │ 85.92 │ 86.56
2022HeartSpot MP+HLine with DenseNet121 proposedROC AUC.84split: test · backbone=DenseNet121 · resolution=320×320 · compression=MP+HLineHeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline.
2022HeartSpot MP+HLine with DenseNet121 proposedROC AUC improvement+0.01split: test · backbone=DenseNet121 · comparison=baseline DenseNet121 · compression=MP+HLineHeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline.
2022Label-Supervised baselineAUROC78.90split: valBreaking with Fixed Set Pathology Recognition through Report-Guided Contrastive Training
Source quote
L206: Label-Supervised │ 77.26 │ 77.42 │ 78.90 │ 79.70 │ 76.47
2021GAN-based augmentation proposedAUC (ROC-AUC)0.758split: val · 1-data · pathology=Lung LesionGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L106: Lung Lesion │ 0.727 │ 0.728 │ 0.758
2021GAN-based augmentation proposedAUC (ROC-AUC)0.594split: val · 1-data · pathology=Pleural OtherGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L107: 1% │ Pleural Other │ 0.566 │ 0.550 │ 0.594
2021GAN-based augmentation proposedAUC (ROC-AUC)0.656split: val · 1-data · pathology=FractureGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L108: Fracture │ 0.583 │ 0.601 │ 0.656
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.892split: test · disease=Pleural Effusion · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.961split: test · disease=Consolidation · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.924split: test · disease=Edema · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021ODIN (pert. only) ablationOOD AUROC0.841setting=1 · variant=perturbation-only · backbone=WRN-100x2 · ID-classes=Cardiomegaly, Pneumothorax · OOD-classes=FractureConfidence-Based Out-of-Distribution Detection: A Comparative Study and Analysis
Source quote
L147: ODIN (pert. only) │ 0.841 │ 0.819 │ 0.888 │ 0.865 │ 0.856 │ 0.757
2021ODIN (temp. only) ablationOOD AUROC0.678setting=1 · variant=temperature-only · backbone=WRN-100x2 · ID-classes=Cardiomegaly, Pneumothorax · OOD-classes=FractureConfidence-Based Out-of-Distribution Detection: A Comparative Study and Analysis
Source quote
L148: ODIN (temp. only) │ 0.678 │ 0.695 │ 0.888 │ 0.444 │ 0.575 │ 0.757
2021ODIN (pert. only) ablationOOD AUROC0.865setting=2 · variant=perturbation-only · backbone=WRN-100x2 · ID-classes=Lung Opacity, Pleural Effusion · OOD-classes=Fracture, PneumoniaConfidence-Based Out-of-Distribution Detection: A Comparative Study and Analysis
Source quote
L147: ODIN (pert. only) │ 0.841 │ 0.819 │ 0.888 │ 0.865 │ 0.856 │ 0.757
2021ODIN (temp. only) ablationOOD AUROC0.444setting=2 · variant=temperature-only · backbone=WRN-100x2 · ID-classes=Lung Opacity, Pleural Effusion · OOD-classes=Fracture, PneumoniaConfidence-Based Out-of-Distribution Detection: A Comparative Study and Analysis
Source quote
L148: ODIN (temp. only) │ 0.678 │ 0.695 │ 0.888 │ 0.444 │ 0.575 │ 0.757
2021No augmentation baselineAUC (ROC-AUC)0.727split: val · 1-data · pathology=Lung LesionGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L106: Lung Lesion │ 0.727 │ 0.728 │ 0.758
2021No augmentation baselineAUC (ROC-AUC)0.566split: val · 1-data · pathology=Pleural OtherGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L107: 1% │ Pleural Other │ 0.566 │ 0.550 │ 0.594
2021No augmentation baselineAUC (ROC-AUC)0.583split: val · 1-data · pathology=FractureGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L108: Fracture │ 0.583 │ 0.601 │ 0.656
2021ODIN baselineOOD AUROC0.841setting=1 · backbone=WRN-100x2 · ID-classes=Cardiomegaly, Pneumothorax · OOD-classes=FractureConfidence-Based Out-of-Distribution Detection: A Comparative Study and Analysis
Source quote
L146: ODIN │ 0.841 │ 0.819 │ 0.888 │ 0.862 │ 0.856 │ 0.758
2021ODIN baselineOOD AUROC0.862setting=2 · backbone=WRN-100x2 · ID-classes=Lung Opacity, Pleural Effusion · OOD-classes=Fracture, PneumoniaConfidence-Based Out-of-Distribution Detection: A Comparative Study and Analysis
Source quote
L146: ODIN │ 0.841 │ 0.819 │ 0.888 │ 0.862 │ 0.856 │ 0.758
2021Clustering selection baseline baselineAUROC0.693split: test · few-shot · selected-labels=K=10 · condition-subset=non-holdoutMedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement Learning
Source quote
L70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}.
2021Clustering selection baseline baselineAUROC0.850split: test · few-shot · selected-labels=K=10 · condition-subset=holdout: Edema and AtelectasisMedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement Learning
Source quote
L70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}.
2020CAN proposedAverage AUROC0.768views=frontal-only · labels=14-label · uncertain-labels=U-OnesMulti-label Thoracic Disease Image Classification with Cross-Attention Networks
Source quote
L160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775
2020CAN proposedAverage AUROC0.775views=frontal-and-lateral-equally · labels=14-label · uncertain-labels=U-OnesMulti-label Thoracic Disease Image Classification with Cross-Attention Networks
Source quote
L160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775
2020Input Mixup baselineMean AUROC0.6731split: test · semi-supervised · classes=14 · labeled-samples=300Semi-supervised Medical Image Classification with Global Latent Mixing
Source quote
L359: Input Mixup │ 0.6491 │ 0.6627 │ 0.6731 │ 0.6779 │ 0.6823 │ 0.8504 │ 0.8609 │ 0.9040
2020Latent-space self-ensembling baselineMean AUROC0.6697split: test · semi-supervised · classes=14 · labeled-samples=500Semi-supervised Medical Image Classification with Global Latent Mixing
Source quote
L380: Latent-space self-ensembling │ 0.6200 │ 0.6386 │ 0.6484 │ 0.6637 │ 0.6697
2020CheXNet baselineAverage AUROC0.734views=frontal-only · labels=14-label · uncertain-labels=U-OnesMulti-label Thoracic Disease Image Classification with Cross-Attention Networks
Source quote
L160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775
2020CheXNet baselineAverage AUROC0.746views=frontal-and-lateral-equally · labels=14-label · uncertain-labels=U-OnesMulti-label Thoracic Disease Image Classification with Cross-Attention Networks
Source quote
L160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775