| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | final model (ensemble of the best performing networks) SOTA frontier | 0.94 | 2021-01-01 | labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensemble · Mean over 5 selected pathologies; validation studies use the majority vote of 3 board… | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteThe chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2 | DenseNet121-MaxAUC | 0.935 | 2023-01-01 | subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGrad · Mean across Cardiomegaly, Edema, Consolidation, Atelectasis, and Pleural Effusion. Ma… | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteDenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935 |
| 3 | FDAM (DenseNet161) (+1 variant) | 0.9333 | 2021-01-01 | K=2; training uses CheXpert and ChestXray8 data. Evaluated on CheXpert validation dat… | Federated Deep AUC Maximization for Hetergeneous Data with a Constant Communication ComplexitySource quote0.9333 |
| 4 | Proposed MARL framework (Ours, ResNet) | 0.925 | 2023-01-01 | backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1 · Validation set; mean over the five competition-task pathologies. Uncertain labels map… | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925 |
| 5 | Proposed instrumental variable learning framework | 0.923 | 2023-01-01 | uncertain-labels=mapped-to-1 · Average across five competition-task pathologies; the evaluation section states uncer… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923 |
Showing 21 of 21 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.487 | split: test | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL307: both models (0.487 and 0.536, with intervals including 0.5). |
| 2026 | Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.536 | split: test · backbone=ViT-B/16 | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL307: both models (0.487 and 0.536, with intervals including 0.5). |
| 2026 | TENT baseline | mean AUROC | 77.4 | split: test · test-time-adaptation | Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray DiagnosisSource quoteL141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4 |
| 2025 | Synthetic+Real mix model proposed | AUROC | 0.730 | split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained · evaluation-view=PA | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733), |
| 2025 | Real-only baseline baseline | AUROC | 0.700 | split: test · training-data=66k real MIMIC-CXR images · initialization=ImageNet-pretrained · evaluation-view=PA | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733), |
| 2024 | MSN+x-SM | AUROC | 0.766 | split: test · linear-probe · backbone=ViT-T | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL550: MSN+ x-SM │ 0.766 (0.745, 0.786) \color{green}\uparrow\uparrow │ 0.402 (0.387, 0.427) \color{green}\uparrow │ \color{blue}{0.716^* (0.712, 0.719)} \color{green}\uparrow\uparrow │ \color{blue}{0.241^* (0.236, 0.249)} \color{green}\uparrow\uparrow |
| 2024 | MSN baseline | AUROC | 0.740 | split: test · linear-probe · backbone=ViT-T | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL534: MSN │ 0.740 (0.720, 0.763) │ 0.396 (0.382, 0.421) │ 0.676 (0.671, 0.68) │ 0.199 (0.197, 0.203) |
| 2024 | MINE baseline | AUROC | 87.7 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=inverted | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4 |
| 2024 | Rebalance baseline | AUROC | 79.8 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=inverted | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8 |
| 2024 | MINE baseline | AUROC | 92.4 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balanced | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4 |
| 2024 | Rebalance baseline | AUROC | 90.0 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balanced | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8 |
| 2024 | Previous image baseline non-standard slice | macro-average AUROC | 0.572 | split: test · subset=Diff subset | Towards Predicting Temporal Changes in a Patient's Chest X-ray Images based on Electronic Health RecordsSource quoteL482: Previous image │ 0.768 │ 0.846 │ 0.572 |
| 2022 | HeartSpot MP+HLine with DenseNet121 proposed | ROC AUC | .84 | split: test · backbone=DenseNet121 · resolution=320×320 · compression=MP+HLine | HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly DetectionSource quoteL123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline. |
| 2022 | HeartSpot MP+HLine with DenseNet121 proposed | ROC AUC improvement | +0.01 | split: test · backbone=DenseNet121 · comparison=baseline DenseNet121 · compression=MP+HLine | HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly DetectionSource quoteL123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline. |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.892 | split: test · disease=Pleural Effusion · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.961 | split: test · disease=Consolidation · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | Same-label misclassification identifier (LightGBM) proposed | AUROC | 0.924 | split: test · disease=Edema · models-averaged=10 | CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-raysSource quoteL123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly. |
| 2021 | Clustering selection baseline baseline | AUROC | 0.693 | split: test · few-shot · selected-labels=K=10 · condition-subset=non-holdout | MedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement LearningSource quoteL70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}. |
| 2021 | Clustering selection baseline baseline | AUROC | 0.850 | split: test · few-shot · selected-labels=K=10 · condition-subset=holdout: Edema and Atelectasis | MedSelect: Selective Labeling for Medical Image Classification Combining Meta-Learning with Deep Reinforcement LearningSource quoteL70: We find that MedSelect is able to significantly outperform random and clustering based selection strategies, as well as a strategy based on clinical metadata. The clustering baseline outperforms the random and clinical baselines, especially for small K. For K=10 on non-holdout conditions, clustering achieves 0.693 AUROC compared to 0.663 for random and 0.666 for clinical. For K=10 on holdout conditions, clustering achieves 0.850 AUROC compared to 0.808 for random and 0.815 for clinical. We show the AUROC scores obtained by the MedSelect and the baseline selectors, as well as the improvements obtained by MedSelect over the clustering baseline, in Figure \ref{fig:raw_results}. |
| 2020 | Input Mixup baseline | Mean AUROC | 0.6731 | split: test · semi-supervised · classes=14 · labeled-samples=300 | Semi-supervised Medical Image Classification with Global Latent MixingSource quoteL359: Input Mixup │ 0.6491 │ 0.6627 │ 0.6731 │ 0.6779 │ 0.6823 │ 0.8504 │ 0.8609 │ 0.9040 |
| 2020 | Latent-space self-ensembling baseline | Mean AUROC | 0.6697 | split: test · semi-supervised · classes=14 · labeled-samples=500 | Semi-supervised Medical Image Classification with Global Latent MixingSource quoteL380: Latent-space self-ensembling │ 0.6200 │ 0.6386 │ 0.6484 │ 0.6637 │ 0.6697 |