CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 89 of 89 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026VIVID-Med proposedmacro-AUC0.8588linear-probeVIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTs
Source quote
L128: Table~\ref{tab:main_combined} summarizes performance on CheXpert and NIH. In-domain, VIVID-Med achieves an exceptional 0.8588 macro-AUC on CheXpert, outperforming BiomedCLIP by {+}6.65 points despite using 500× less pretraining data. Conversely, self-supervised baselines (MAE, DINOv3) show competitive F1s but substantially lower AUCs, highlighting their inability to capture clinical ranking structures without explicit semantic guidance.
2026Causal conditioning (sampling) proposedAUC of pleural effusion predictor82.33generation=sampling · conditioning=causalTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Causal conditioning (counterfactual generation) proposedAUC of pleural effusion predictor81.67generation=counterfactual · conditioning=causalTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Deterministic conditioning (sampling) baselineAUC of pleural effusion predictor80.65generation=sampling · conditioning=deterministicTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Undirected conditioning (sampling) baselineAUC of pleural effusion predictor82.15generation=sampling · conditioning=undirectedTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Deterministic conditioning (counterfactual generation) baselineAUC of pleural effusion predictor79.79generation=counterfactual · conditioning=deterministicTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Undirected conditioning (counterfactual generation) baselineAUC of pleural effusion predictor81.54generation=counterfactual · conditioning=undirectedTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2025Autonomous distillation proposedAUC0.920-shotTurning Drift into Constraint: Robust Reasoning Alignment in Non-Stationary Multi-Stream Environments
Source quote
L271: CARZero │ 0.84 │ 0.81 │ 0.92 │ 0.80 {\color[HTML]{FF0000} Ours} │ {\color[HTML]{FF0000} 0.85} │ {\color[HTML]{FF0000} 0.83} │ {\color[HTML]{FF0000} 0.92} │ {\color[HTML]{FF0000} 0.81} }
2025MV-HFMD proposedAUC-ROC0.775label-setting=average across five uncertain-label scenarios and 13 classification tasksMCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIP
Source quote
L393: 0.775
2025AdvSimplex (Medical CLIP, CheXzero paradigm, ViT-B) proposed non-standard slicePGD AUC0.7350-shot · attack=PGD-20 · epsilon=1/255 · backbone=ViT-BImproving Zero-Shot Adversarial Robustness in Vision-Language Models by Closed-form Alignment of Adversarial Path Simplices
Source quote
L1165: 0.735
2025AGA proposedAUC56.10linear-probe · labeled-data=1%AGA: An adaptive group alignment framework for structured medical cross-modal representation learning
Source quote
L274: AGA │ 56.10 │ 61.31 │ 84.32 │ 68.91 │ 75.78 │ 87.92
2025DualNet baselineAUC-ROC0.738label-setting=average across five uncertain-label scenarios and 13 classification tasksMCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIP
Source quote
L384: 0.738
2025MGCA baselineAUC55.21linear-probe · labeled-data=1%AGA: An adaptive group alignment framework for structured medical cross-modal representation learning
Source quote
L272: MGCA\cite{7} │ 55.21 │ 59.21 │ 83.92 │ 67.28 │ 76.12 │ 87.76
2024RadGazeGen proposedAUC (Avg across 12 pathologies)71.33split: test · classes=12 pathologies · sample-size=500RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion Models
Source quote
L207: RadGazeGen │ 80.71 │ 70.34 │ 77.67 │ 73.47 │ 66.57 │ 88.20 │ 78.31 │ 53.29 │ 77.46 │ 62.74 │ 52.32 │ 74.90 │ 71.33
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC72.24split: test · training-data=10%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L289: 72.24
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC91.02split: test · training-data=40%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L292: 91.02
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC98.21split: test · training-data=100%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L298: 98.21
2024MMCLIP baselineAUC90.53split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L262: MMCLIP │ 90.53 │ 67.05 │ 86.04 │ 85.79 │ 33.50 │ 91.19 │ 86.16 │ 62.57 │ 80.46
2024MedKlip baselineAUC89.97split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L260: MedKlip \cite{wu2023medklip} │ 89.97 │ 63.67 │ 84.32 │ 84.97 │ 35.17 │ 90.68 │ 86.94 │ 63.42 │ 80.02
2024SD baselineAUC (Avg across 12 pathologies)71.12split: test · classes=12 pathologies · sample-size=500RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion Models
Source quote
L204: SD │ 72.57 │ 73.64 │ 73.77 │ 75.28 │ 64.24 │ 83.32 │ 74.59 │ 68.07 │ 59.24 │ 58.36 │ 71.70 │ 78.67 │ 71.12
2024GESTALT baselineAUC70.82split: test · training-data=10%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L277: 70.82
2024GESTALT baselineAUC89.27split: test · training-data=40%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L280: 89.27
2024GESTALT baselineAUC96.71split: test · training-data=100%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L286: 96.71
2023GAT (Gender auxiliary task) proposed non-standard sliceRobust AUC83.00attack=PGD-10 · target=Atelectasis · auxiliary-task=Gender · perturbation-budget=ℓ∞ ε=4/255GAT: Guided Adversarial Training with Pareto-optimal Auxiliary Tasks
Source quote
L887: Atelectasis │ Gender │ 83.00 │ 83.35
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC89.24%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023ELIXR-C proposedMean AUC0.850split: test · 0-shot · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L434: 0.850
2023ELIXR-B linear proposedMean AUC0.893split: test · linear-probe · findings=5 · training-data=1% (~2,200 images)ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L449: 0.893
2023CSDA (Ours; full proposed framework with VCQ) proposedAUC0.6792semi-supervised · labeled-samples=500Class-Specific Distribution Alignment for semi-supervised medical image classification
Source quote
L406: Ours │ 0.6499 │ 0.6619 │ 0.6694 │ 0.6762 │ 0.6792
2023M-FLAG proposedAUC64.4%fine-tuned · labeled-data=1%M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry Optimization
Source quote
L112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7
2023Proposed instrumental variable learning framework proposedMean AUC0.923split: val · uncertain-labels=mapped-to-1Instrumental Variable Learning for Chest X-ray Classification
Source quote
L219: Mean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923
2023Proposed MARL framework (Ours, ResNet) proposedMean AUC0.925split: val · backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidance
Source quote
L319: Mean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925
2023EEEA-Net-C2 student (DenseNet161 teacher) proposedAUC87.1%split: val · student=EEEA-Net-C2 · teacher=DenseNet161Explainable Knowledge Distillation for On-device Chest X-Ray Classification
Source quote
L6: \begin{abstract} Automated multi-label chest X-rays (CXR) image classification has achieved substantial progress in clinical diagnosis via utilizing sophisticated deep learning approaches. However, most deep models have high computational demands, which makes them less feasible for compact devices with low computational requirements. To overcome this problem, we propose a knowledge distillation (KD) strategy to create the compact deep learning model for the real-time multi-label CXR image classification. We study different alternatives of CNNs and Transforms as the teacher to distill the knowledge to a smaller student. Then, we employed explainable artificial intelligence (XAI) to provide the visual explanation for the model decision improved by the KD. Our results on three benchmark CXR datasets show that our KD strategy provides the improved performance on the compact student model, thus being the feasible choice for many limited hardware platforms. For instance, when using DenseNet161 as the teacher network, EEEA-Net-C2 achieved an AUC of 83.7%, 87.1%, and 88.7% on the ChestX-ray14, CheXpert, and PadChest datasets, respectively, with fewer parameters of 4.7 million and computational cost of 0.3 billion FLOPS.
2023MPMA (full configuration: image reconstruction, report reconstruction, GLA, and MA-CMF) proposedAUC90.6Component ablation study; full MPMA configuration. The caption identifies CheXpert AUC …Multi-Task Paired Masking With Alignment Modeling for Medical Vision-Language Pre-Training
Source quote
L230: \surd │ \surd │ \surd │ \surd │ 90.6 │ 0.295 │ 77.6
2023MRM (ViT-B/16) proposedmean AUC88.5%fine-tuned · backbone=ViT-B/16 · labeled-data=1%Advancing Radiograph Representation Learning with Masked Record Modeling
Source quote
L186: Nonetheless, MRM consistently outperforms various baselines on all three datasets under different labeling ratios. Specifically, MRM maintains more advantages over previous pre-training methodologies when fine-tuning with limited annotations, which is quite meaningful for medical image analysis as large amounts of specialist annotations (from radiologists or clinicians) are usually hard to access. It is worth noting that MRM achieves 88.5% when using only 1% labeled data on CheXpert, better than previous counterparts with 100% annotations.
2023Single-task adversarial training (no auxiliary task) ablation non-standard sliceRobust AUC50.00attack=PGD-10 · target=Atelectasis · auxiliary-task=none · perturbation-budget=ℓ∞ ε=4/255GAT: Guided Adversarial Training with Pareto-optimal Auxiliary Tasks
Source quote
L883: Atelectasis │ Single task │ 50.00 │ 58.76
2023Image-reconstruction-only ablation (MIM loss only) ablationAUC84.3Component ablation baseline retaining only image reconstruction loss; medical image cla…Multi-Task Paired Masking With Alignment Modeling for Medical Vision-Language Pre-Training
Source quote
L227: \surd │ 84.3 │ 0.260 │ 70.8
2023Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baselineAUC89.97%split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023CheXzero ensemble baselineMean AUC0.838split: test · 0-shot · method=CheXzero ensemble · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L431: 0.838
2023Xi et al. baselineMean AUC0.917split: valInstrumental Variable Learning for Chest X-ray Classification
Source quote
L219: Mean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923
2023Xi et al. baselineMean AUC0.917split: valDeep reinforcement learning framework for thoracic diseases classification via prior knowledge guidance
Source quote
L319: Mean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925
2022MobileNetV3-Large (MDW; dense convolution with Winograd) proposedAverage AUC0.882split: val · secure-inference · backbone=MobileNetV3-Large · operator=dense convolution with Winograd · patients=200 · label-handling=U-OnesEfficient ML Models for Practical Secure Inference
Source quote
L387: Dense │ \checkmark │ MDW │ 8.30× │ 2.91× │ 0.882
2022HeartSpot (RH)Line+Heart with a two-layer MLP proposedAUC ROC.78split: test · classifier=two-layer MLP · resolution=320×320 · training-iterations=300HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L122: For the MLP, we observe that HeartSpot\xspace (RH)Line+Heart is preferred, giving 17 seconds per epoch (8x faster than DenseNet121) and .78 AUC ROC.
2022Proposed multimorbidity proxy metric learning method (Ours, With Neg. Proxies) proposedAUC0.77disease-labels=9 · negative-proxies=used · training-samples=4096Multimorbidity Content-Based Medical Image Retrieval Using Proxies
Source quote
L254: Ours (With Neg. Proxies) │ 0.77 │ 0.30 │ 0.48 │ 0.82
2022DOS proposedtesting AUC0.65split: test · federated-learning · setting=final-crafted-model-attackSuppressing Poisoning Attacks on Federated Learning for Medical Imaging
Source quote
L126: Figure \ref{fig3} compares all the aggregation rules under six different scenarios on the CheXpert dataset. In the No Attack case, the DOS method outperforms Krum and produces comparable results to the other methods including FedAvg, which was essentially designed for benign settings. When one of the clients was trained by flipping class label 0 to 1, all of the methods performed well with Krum having a marginal advantage. For the mixed attack case, DOS had a faster convergence rate in the beginning with a marginal drop in round 70 whereas FedAvg was compromised. When four clients transmitted random Gaussian noise, FedAvg and Trimmed Mean were compromised, whereas DOS and Coordinate-Wise-Median performed best. In the noise and scaled parameters attack, FedAvg and Trimmed Mean were compromised from the start while the Coordinate-Wise-Median's performance started deteriorating at round 60. The DOS method and Krum performed best in this scenario. In the final crafted model setting, we compared DOS only with Krum as this attack was specifcially designed against Krum. In this attack, we can clearly see that DOS significantly outperforms Krum with a testing AUC of 0.65 vs. 0.50. Table \ref{labcomp} summarizes the average AUC for all rounds and it can be observed that DOS aggregation rule performs consistently well against all attack scenarios. In contrast, all the other aggregation rules had lower accuracy values in one or more scenarios. Furthermore, it can be observed from Figure \ref{fig3} that the weights of the malicious clients (shown in red) are almost always close to zero, indicating that the DOS method is able to effectively suppress the parameter updates from malicious clients.
2022ShuffleNetV2 (SX; X-operator, without Winograd) ablationAverage AUC0.868split: val · secure-inference · backbone=ShuffleNetV2 · operator=X-operator without Winograd · patients=200 · label-handling=U-OnesEfficient ML Models for Practical Secure Inference
Source quote
L397: X-op │ SX │ 30.15× │ 15.35× │ 0.868
2022DenseNet-121 (DD; dense-convolution baseline) baselineAverage AUC0.888split: val · backbone=DenseNet-121 · patients=200 · label-handling=U-OnesEfficient ML Models for Practical Secure Inference
Source quote
L371: Dense │ DD │ 1× │ 1× │ 0.888
2022DAM (deep AUC maximization; specific method not named in the survey table) baselineAUC0.9305split: test · imbalance=naturalAUC Maximization in the Era of Big Data and AI: A Survey
Source quote
L579: CheXpert │ Chest X-ray Image │ 10^5 │ Natural │ \cite{irvin2019chexpert} │ \cite{DBLP:journals/corr/abs-2012-03173,zhubenchmark} │ 0.9305
2021RadKG+ConvE proposedAUC0.835folds=3 random folds · uncertain-label-policy=positiveA Relational-learning Perspective to Multi-label Chest X-ray Classification
Source quote
L100: RadKG+ConvE │ 0.835 \\[0.25ex]
2021RadKG link-prediction formulation (scoring function not specified in this sentence) proposedAUC0.833folds=3 random folds · uncertain-label-policy=unclearA Relational-learning Perspective to Multi-label Chest X-ray Classification
Source quote
L83: Link prediction on RadKG: Assessing the ability of a straightforward relational formulation, wherein we incorporate a KG with just the \texttt{hasFinding} relation, indicating positive annotations. The proposed approach consistently outperforms our baselines and prior work in both Tables~\ref{tab:perf}a and \ref{tab:perf}b, irrespective of the chosen scoring function. ConvE marginally outperforms DistMult, but its significance cannot be ascertained due to lack of sufficient samples. Interestingly, the trend of performances when Uncertain\rightarrowPositive being inferior to Uncertain\rightarrowNegative in the discriminative approaches is flipped in the relational approaches (0.835 vs. 0.833).
2021Equal Loss Train, α=100 proposedAUC0.835split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=male · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Equal Loss Train, α=100 proposedAUC0.819split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=female · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Proposed method (HAM), ResNet50 backbone proposedMean AUC0.888split: test · backbone=ResNet50 · ensemble=no · uncertainty-labels=U-OnesLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021Proposed method (HAM), ResNet152 backbone proposedMean AUC0.895split: test · backbone=ResNet152 · ensemble=no · uncertainty-labels=U-OnesLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021S^2MTS^2 proposedMean AUC over 14 disease classes71.58semi-supervised · labeled-data=500 samples per classSelf-supervised Mean Teacher for Semi-supervised Chest X-Ray Classification
Source quote
L219: Ours │ 66.15 │ 67.85 │ 70.83 │ 71.37 │ 71.58 }
2021Any Disease model + Random Forest on the Penultimate Layer proposedmean AUC0.879split: test · features=penultimate-layer · classifier=random-forestCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L256: 0.879 (0.849,0.901)
2021Any Disease model + Random Forest on the Final Prediction Layer proposedmean AUC0.875split: test · features=final-prediction-layer · classifier=random-forestCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L245: 0.875 (0.848,0.899)
2021Cardiomegaly + 11 diseases from CheXpert proposedAUC of “Card”87.5%target-class=cardiomegaly · label-setting=alternative-class labels · additional-diseases=11Data, Assemble: Leveraging Multiple Datasets with Heterogeneous and Partial Labels
Source quote
L780: + 11 Diseases (\dagger) │ 87.5~\mkgreen{(\uparrow1.6)}
2021All Diseases ablationmean AUC0.851split: test · training-setting=all-images-all-labelsCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L175: 0.851 (0.828,0.871)
2021Subset-Unlabeled ablation non-standard slicemean AUC0.888split: test · training-setting=all-images-unseen-disease-labels-removedCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L181: 0.888 (0.868,0.906)
2021Subset-Unseen ablation non-standard slicemean AUC0.861split: test · training-setting=images-without-unseen-diseasesCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L187: 0.861 (0.839,0.881)
2021FDAM (DenseNet161)AVG (AUC across C0–C4)0.9316split: valFederated Deep AUC Maximization for Hetergeneous Data with a Constant Communication Complexity
Source quote
L660: 0.9316
2021FDAM (DenseNet161)AVG (AUC across C0–C4)0.9333split: valFederated Deep AUC Maximization for Hetergeneous Data with a Constant Communication Complexity
Source quote
L667: 0.9333
2021B+MODLMean AUC91.35%CheXpert AUC comparison; MODL applied to the single target model; reported mean column.Many-to-One Distribution Learning and K-Nearest Neighbor Smoothing for Thoracic Disease Identification
Source quote
L117: B+MODL │ 87.64 │ 87.84 │ 93.34 │ 94.58 │ 93.35 │ 91.35
2021B+KNNSMean AUC91.48%CheXpert AUC comparison; KNNS applied to the single target model; reported mean column.Many-to-One Distribution Learning and K-Nearest Neighbor Smoothing for Thoracic Disease Identification
Source quote
L118: B+KNNS │ 89.15 │ 88.24 │ 92.40 │ 94.92 │ 92.67 │ 91.48
2021B+MODL+KNNSMean AUC92.63%CheXpert AUC comparison; combined MODL and KNNS on the single target model; reported me…Many-to-One Distribution Learning and K-Nearest Neighbor Smoothing for Thoracic Disease Identification
Source quote
L119: B+MODL+KNNS │ 89.46 │ 89.67 │ 93.80 │ 95.87 │ 94.35 │ 92.63
2021Model Ensemble 1Mean AUC92.19%Ensemble of DenseNet-121, DenseNet-169, and DenseNet-201.Many-to-One Distribution Learning and K-Nearest Neighbor Smoothing for Thoracic Disease Identification
Source quote
L166: Model Ensemble 1 │ 92.19 │ 42.13 M
2021Model Ensemble 2Mean AUC93.96%Ensemble of the six reference models used to learn the soft label distribution.Many-to-One Distribution Learning and K-Nearest Neighbor Smoothing for Thoracic Disease Identification
Source quote
L167: Model Ensemble 2 │ 93.96 │ 208.33 M
2021Pham et al. six-model ensemble baselineMean AUC0.930split: test · backbone=DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, NASNetLarge · ensemble=six-modelLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021LatentMixing baselineMean AUC over 14 disease classes68.47semi-supervised · labeled-data=500 samples per classSelf-supervised Mean Teacher for Semi-supervised Chest X-Ray Classification
Source quote
L218: LatentMixing \cite{gyawali2020semi} │ 65.12 │ 66.41 │ 67.39 │ 67.96 │ 68.47
2021Baseline (B; DenseNet-121) baselineMean AUC89.37%CheXpert AUC comparison; single target model; reported mean column.Many-to-One Distribution Learning and K-Nearest Neighbor Smoothing for Thoracic Disease Identification
Source quote
L116: Baseline (B) │ 87.29 │ 84.47 │ 92.09 │ 91.66 │ 91.34 │ 89.37
2021Cardiomegaly-only training baselineAUC of “Card”85.9%target-class=cardiomegaly · training-setting=cardiomegaly-onlyData, Assemble: Leveraging Multiple Datasets with Heterogeneous and Partial Labels
Source quote
L773: Cardiomegaly │ 85.9
2020final model (ensemble of the best performing networks) proposedmean AUC0.940split: val · labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensembleInterpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labels
Source quote
L4: The chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm]
2020proposed method (deep learning algorithm) proposedmean AUC0.930split: test · subset=independent competition reader-study test set · labeling=consensus of 5 board-certified radiologists · pathologies=5 · sample-size=500 CXR studiesInterpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labels
Source quote
L4: The chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm]
2020L2TL proposedMean AUC across five classes90.0fine-tuned · backbone=DenseNet-121 · evaluation=ten-crop · ensemble-checkpoints=30Learning to Transfer Learn: Reinforcement Learning-Based Selection for Adaptive Transfer Learning
Source quote
L583: 90.0
2020DenseNet121-MaxAUC proposedMean AUC (five selected diseases)0.935split: val · subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGradFast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL Condition
Source quote
L302: DenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935
2020MaxAUC proposedAUC0.922split: test · subset=five diseases · evaluation=competition private testing setFast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL Condition
Source quote
L293: It is notable that the current winner~\cite{pham2019interpreting} use all diseases and conditional training that incorporates the hierarchical taxonomy of 14 diseases to train deep networks, and they use an ensemble of 6 networks. In contrast, we only use the 5 diseases and train deep networks for each disease separately without using the domain knowledge. The final results in Table~\ref{table:chexpert} show that our ensemble model by AUC maximization has a better validation AUC than the current winner, and also improves the ensemble of based models trained by Adam by 1% on average. From the table, we also see that our method achieves the highest AUC on Edema, Consolidation, Atelectasis, competitive AUC on Pleural Effusion and slightly worse AUC on Cardiomegaly. On August 4, 2020, we submitted our models (MaxAUC) for evaluation on private testing set and the results ranks 35th on the CheXpert competition with an AUC of 0.922 on private testing set.
2020ChexRadiNet proposedMean AUC0.890Classification; mean column in the CheXpert AUC table.Using Radiomics as Prior Knowledge for Thorax Disease Classification and Localization in Chest X-rays
Source quote
L195: ChexRadiNet │ 0.831 │ 0.848 │ 0.920 │ 0.930 │ 0.921 │ 0.890
2020ResNet-18 with weak augmentation, mixup, and confidence tempering (CT) proposedW-AUC0.833few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=withSelf-Training with Improved Regularization for Few-Shot Chest X-Ray Classification
Source quote
L164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations.
2020MoCo-CXR-pretrained end-to-end model (ResNet18) proposedAUC0.813fine-tuned · backbone=ResNet18 · labeled-data-fraction=0.1%MoCo-CXR: MoCo Pretraining Improves Representation and Transferability of Chest X-ray Models
Source quote
L78: We found that MoCo-CXR-pretrained end-to-end models outperform their ImageNet-pretrained counterparts more at small label fractions than at larger label fractions. With the 0.1% label fraction, the ResNet18 MoCo-CXR-pretrained end-to-end model achieved an AUC of 0.813 while the ImageNet-pretrained end-to-end model achieves an AUC of 0.775, yielding a statistically significant AUC improvement of 0.037 (95% CI 0.015, 0.062). The AUC improvement with the 1.0% label fraction was also statistically significant at 0.027 (95% CI 0.006, 0.047). Both pretraining approaches converge to an AUC of 0.942 with the 100% label fraction.
2020ResNet-18 with weak augmentation and mixup, without confidence tempering ablationW-AUC0.819few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=withoutSelf-Training with Improved Regularization for Few-Shot Chest X-Ray Classification
Source quote
L164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations.
2020ConVIRTAUC85.9split: test · linear-probeContrastive Learning of Medical Visual Representations from Paired Images and Text
Source quote
L368: ConVIRT │ 90.7 │ 85.9 │ 42.9
2020MoCo v2AUC81.3split: test · linear-probeContrastive Learning of Medical Visual Representations from Paired Images and Text
Source quote
L367: MoCo v2 │ 86.6 │ 81.3 │ 20.6
2020Fine-tuning baselineMean AUC across five classes89.3fine-tuned · backbone=DenseNet-121 · evaluation=ten-crop · ensemble-checkpoints=30Learning to Transfer Learn: Reinforcement Learning-Based Selection for Adaptive Transfer Learning
Source quote
L576: 89.3
2020DenseNet121-base baselineMean AUC (five selected diseases)0.928split: val · subset=five selected diseases · backbone=DenseNet121Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL Condition
Source quote
L301: DenseNet121-base │ 0.891 │ 0.950 │ 0.951 │ 0.899 │ 0.950 │ 0.928
2020ImageNet-pretrained end-to-end model (ResNet18) baselineAUC0.775fine-tuned · backbone=ResNet18 · labeled-data-fraction=0.1%MoCo-CXR: MoCo Pretraining Improves Representation and Transferability of Chest X-ray Models
Source quote
L78: We found that MoCo-CXR-pretrained end-to-end models outperform their ImageNet-pretrained counterparts more at small label fractions than at larger label fractions. With the 0.1% label fraction, the ResNet18 MoCo-CXR-pretrained end-to-end model achieved an AUC of 0.813 while the ImageNet-pretrained end-to-end model achieves an AUC of 0.775, yielding a statistically significant AUC improvement of 0.037 (95% CI 0.015, 0.062). The AUC improvement with the 1.0% label fraction was also statistically significant at 0.027 (95% CI 0.006, 0.047). Both pretraining approaches converge to an AUC of 0.942 with the 100% label fraction.
2020Top 10 CheXpert competition models (average) baselineAUC0.916aggregation=average of top 10 CheXpert competition models · image-source=photos of chest x-raysCheXpedition: Investigating Generalization Challenges for Translation of Chest X-Ray Algorithms to the Clinical Setting
Source quote
L12: Although there have been several recent advances in the application of deep learning algorithms to chest x-ray interpretation, we identify three major challenges for the translation of chest x-ray algorithms to the clinical setting. We examine the performance of the top 10 performing models on the CheXpert challenge leaderboard on three tasks: (1) TB detection, (2) pathology detection on photos of chest x-rays, and (3) pathology detection on data from an external institution. First, we find that the top 10 chest x-ray models on the CheXpert competition achieve an average AUC of 0.851 on the task of detecting TB on two public TB datasets without fine-tuning or including the TB labels in training data. Second, we find that the average performance of the models on photos of x-rays (AUC = 0.916) is similar to their performance on the original chest x-ray images (AUC = 0.924). Third, we find that the models tested on an external dataset either perform comparably to or exceed the average performance of radiologists. We believe that our investigation will inform rapid translation of deep learning algorithms to safe and effective clinical decision support tools that can be validated prospectively with large impact studies and clinical trials.
2020Top 10 CheXpert competition models (average) baselineAUC0.924aggregation=average of top 10 CheXpert competition models · image-source=original chest x-ray imagesCheXpedition: Investigating Generalization Challenges for Translation of Chest X-Ray Algorithms to the Clinical Setting
Source quote
L12: Although there have been several recent advances in the application of deep learning algorithms to chest x-ray interpretation, we identify three major challenges for the translation of chest x-ray algorithms to the clinical setting. We examine the performance of the top 10 performing models on the CheXpert challenge leaderboard on three tasks: (1) TB detection, (2) pathology detection on photos of chest x-rays, and (3) pathology detection on data from an external institution. First, we find that the top 10 chest x-ray models on the CheXpert competition achieve an average AUC of 0.851 on the task of detecting TB on two public TB datasets without fine-tuning or including the TB labels in training data. Second, we find that the average performance of the models on photos of x-rays (AUC = 0.916) is similar to their performance on the original chest x-ray images (AUC = 0.924). Third, we find that the models tested on an external dataset either perform comparably to or exceed the average performance of radiologists. We believe that our investigation will inform rapid translation of deep learning algorithms to safe and effective clinical decision support tools that can be validated prospectively with large impact studies and clinical trials.
2019Learning to Transfer Learn (L2TL) proposedMean AUC90.0fine-tuned · metric_aggregation=mean AUC over five classes · uncertain_examples=treated as positiveLearning to Transfer Learn
Source quote
L353: Our L2TL │ 86.1 │ 84.4 │ 91.5 │ 94.8 │ 93.2 │ 90.0
2019Fine-tuning baselineMean AUC89.3fine-tuned · metric_aggregation=mean AUC over five classes · uncertain_examples=treated as positiveLearning to Transfer Learn
Source quote
L351: Fine-tuning │ 85.2 │ 83.8 │ 90.0 │ 94.5 │ 92.8 │ 89.3