CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 32 of 32 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024RadGazeGen proposedAUC (Avg across 12 pathologies)71.33split: test · classes=12 pathologies · sample-size=500RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion Models
Source quote
L207: RadGazeGen │ 80.71 │ 70.34 │ 77.67 │ 73.47 │ 66.57 │ 88.20 │ 78.31 │ 53.29 │ 77.46 │ 62.74 │ 52.32 │ 74.90 │ 71.33
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC72.24split: test · training-data=10%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L289: 72.24
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC91.02split: test · training-data=40%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L292: 91.02
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC98.21split: test · training-data=100%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L298: 98.21
2024MMCLIP baselineAUC90.53split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L262: MMCLIP │ 90.53 │ 67.05 │ 86.04 │ 85.79 │ 33.50 │ 91.19 │ 86.16 │ 62.57 │ 80.46
2024MedKlip baselineAUC89.97split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L260: MedKlip \cite{wu2023medklip} │ 89.97 │ 63.67 │ 84.32 │ 84.97 │ 35.17 │ 90.68 │ 86.94 │ 63.42 │ 80.02
2024SD baselineAUC (Avg across 12 pathologies)71.12split: test · classes=12 pathologies · sample-size=500RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion Models
Source quote
L204: SD │ 72.57 │ 73.64 │ 73.77 │ 75.28 │ 64.24 │ 83.32 │ 74.59 │ 68.07 │ 59.24 │ 58.36 │ 71.70 │ 78.67 │ 71.12
2024GESTALT baselineAUC70.82split: test · training-data=10%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L277: 70.82
2024GESTALT baselineAUC89.27split: test · training-data=40%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L280: 89.27
2024GESTALT baselineAUC96.71split: test · training-data=100%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L286: 96.71
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC89.24%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023ELIXR-C proposedMean AUC0.850split: test · 0-shot · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L434: 0.850
2023ELIXR-B linear proposedMean AUC0.893split: test · linear-probe · findings=5 · training-data=1% (~2,200 images)ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L449: 0.893
2023Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baselineAUC89.97%split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023CheXzero ensemble baselineMean AUC0.838split: test · 0-shot · method=CheXzero ensemble · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L431: 0.838
2022HeartSpot (RH)Line+Heart with a two-layer MLP proposedAUC ROC.78split: test · classifier=two-layer MLP · resolution=320×320 · training-iterations=300HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L122: For the MLP, we observe that HeartSpot\xspace (RH)Line+Heart is preferred, giving 17 seconds per epoch (8x faster than DenseNet121) and .78 AUC ROC.
2022DOS proposedtesting AUC0.65split: test · federated-learning · setting=final-crafted-model-attackSuppressing Poisoning Attacks on Federated Learning for Medical Imaging
Source quote
L126: Figure \ref{fig3} compares all the aggregation rules under six different scenarios on the CheXpert dataset. In the No Attack case, the DOS method outperforms Krum and produces comparable results to the other methods including FedAvg, which was essentially designed for benign settings. When one of the clients was trained by flipping class label 0 to 1, all of the methods performed well with Krum having a marginal advantage. For the mixed attack case, DOS had a faster convergence rate in the beginning with a marginal drop in round 70 whereas FedAvg was compromised. When four clients transmitted random Gaussian noise, FedAvg and Trimmed Mean were compromised, whereas DOS and Coordinate-Wise-Median performed best. In the noise and scaled parameters attack, FedAvg and Trimmed Mean were compromised from the start while the Coordinate-Wise-Median's performance started deteriorating at round 60. The DOS method and Krum performed best in this scenario. In the final crafted model setting, we compared DOS only with Krum as this attack was specifcially designed against Krum. In this attack, we can clearly see that DOS significantly outperforms Krum with a testing AUC of 0.65 vs. 0.50. Table \ref{labcomp} summarizes the average AUC for all rounds and it can be observed that DOS aggregation rule performs consistently well against all attack scenarios. In contrast, all the other aggregation rules had lower accuracy values in one or more scenarios. Furthermore, it can be observed from Figure \ref{fig3} that the weights of the malicious clients (shown in red) are almost always close to zero, indicating that the DOS method is able to effectively suppress the parameter updates from malicious clients.
2022DAM (deep AUC maximization; specific method not named in the survey table) baselineAUC0.9305split: test · imbalance=naturalAUC Maximization in the Era of Big Data and AI: A Survey
Source quote
L579: CheXpert │ Chest X-ray Image │ 10^5 │ Natural │ \cite{irvin2019chexpert} │ \cite{DBLP:journals/corr/abs-2012-03173,zhubenchmark} │ 0.9305
2021Equal Loss Train, α=100 proposedAUC0.835split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=male · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Equal Loss Train, α=100 proposedAUC0.819split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=female · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Proposed method (HAM), ResNet50 backbone proposedMean AUC0.888split: test · backbone=ResNet50 · ensemble=no · uncertainty-labels=U-OnesLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021Proposed method (HAM), ResNet152 backbone proposedMean AUC0.895split: test · backbone=ResNet152 · ensemble=no · uncertainty-labels=U-OnesLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021Any Disease model + Random Forest on the Penultimate Layer proposedmean AUC0.879split: test · features=penultimate-layer · classifier=random-forestCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L256: 0.879 (0.849,0.901)
2021Any Disease model + Random Forest on the Final Prediction Layer proposedmean AUC0.875split: test · features=final-prediction-layer · classifier=random-forestCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L245: 0.875 (0.848,0.899)
2021All Diseases ablationmean AUC0.851split: test · training-setting=all-images-all-labelsCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L175: 0.851 (0.828,0.871)
2021Subset-Unlabeled ablation non-standard slicemean AUC0.888split: test · training-setting=all-images-unseen-disease-labels-removedCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L181: 0.888 (0.868,0.906)
2021Subset-Unseen ablation non-standard slicemean AUC0.861split: test · training-setting=images-without-unseen-diseasesCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L187: 0.861 (0.839,0.881)
2021Pham et al. six-model ensemble baselineMean AUC0.930split: test · backbone=DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, NASNetLarge · ensemble=six-modelLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2020proposed method (deep learning algorithm) proposedmean AUC0.930split: test · subset=independent competition reader-study test set · labeling=consensus of 5 board-certified radiologists · pathologies=5 · sample-size=500 CXR studiesInterpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labels
Source quote
L4: The chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm]
2020MaxAUC proposedAUC0.922split: test · subset=five diseases · evaluation=competition private testing setFast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL Condition
Source quote
L293: It is notable that the current winner~\cite{pham2019interpreting} use all diseases and conditional training that incorporates the hierarchical taxonomy of 14 diseases to train deep networks, and they use an ensemble of 6 networks. In contrast, we only use the 5 diseases and train deep networks for each disease separately without using the domain knowledge. The final results in Table~\ref{table:chexpert} show that our ensemble model by AUC maximization has a better validation AUC than the current winner, and also improves the ensemble of based models trained by Adam by 1% on average. From the table, we also see that our method achieves the highest AUC on Edema, Consolidation, Atelectasis, competitive AUC on Pleural Effusion and slightly worse AUC on Cardiomegaly. On August 4, 2020, we submitted our models (MaxAUC) for evaluation on private testing set and the results ranks 35th on the CheXpert competition with an AUC of 0.922 on private testing set.
2020ConVIRTAUC85.9split: test · linear-probeContrastive Learning of Medical Visual Representations from Paired Images and Text
Source quote
L368: ConVIRT │ 90.7 │ 85.9 │ 42.9
2020MoCo v2AUC81.3split: test · linear-probeContrastive Learning of Medical Visual Representations from Paired Images and Text
Source quote
L367: MoCo v2 │ 86.6 │ 81.3 │ 20.6