CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 12 of 12 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC89.24%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023M-FLAG proposedAUC64.4%fine-tuned · labeled-data=1%M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry Optimization
Source quote
L112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7
2023MRM (ViT-B/16) proposedmean AUC88.5%fine-tuned · backbone=ViT-B/16 · labeled-data=1%Advancing Radiograph Representation Learning with Masked Record Modeling
Source quote
L186: Nonetheless, MRM consistently outperforms various baselines on all three datasets under different labeling ratios. Specifically, MRM maintains more advantages over previous pre-training methodologies when fine-tuning with limited annotations, which is quite meaningful for medical image analysis as large amounts of specialist annotations (from radiologists or clinicians) are usually hard to access. It is worth noting that MRM achieves 88.5% when using only 1% labeled data on CheXpert, better than previous counterparts with 100% annotations.
2023Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baselineAUC89.97%split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2021Equal Loss Train, α=100 proposedAUC0.835split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=male · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Equal Loss Train, α=100 proposedAUC0.819split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=female · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2020L2TL proposedMean AUC across five classes90.0fine-tuned · backbone=DenseNet-121 · evaluation=ten-crop · ensemble-checkpoints=30Learning to Transfer Learn: Reinforcement Learning-Based Selection for Adaptive Transfer Learning
Source quote
L583: 90.0
2020MoCo-CXR-pretrained end-to-end model (ResNet18) proposedAUC0.813fine-tuned · backbone=ResNet18 · labeled-data-fraction=0.1%MoCo-CXR: MoCo Pretraining Improves Representation and Transferability of Chest X-ray Models
Source quote
L78: We found that MoCo-CXR-pretrained end-to-end models outperform their ImageNet-pretrained counterparts more at small label fractions than at larger label fractions. With the 0.1% label fraction, the ResNet18 MoCo-CXR-pretrained end-to-end model achieved an AUC of 0.813 while the ImageNet-pretrained end-to-end model achieves an AUC of 0.775, yielding a statistically significant AUC improvement of 0.037 (95% CI 0.015, 0.062). The AUC improvement with the 1.0% label fraction was also statistically significant at 0.027 (95% CI 0.006, 0.047). Both pretraining approaches converge to an AUC of 0.942 with the 100% label fraction.
2020Fine-tuning baselineMean AUC across five classes89.3fine-tuned · backbone=DenseNet-121 · evaluation=ten-crop · ensemble-checkpoints=30Learning to Transfer Learn: Reinforcement Learning-Based Selection for Adaptive Transfer Learning
Source quote
L576: 89.3
2020ImageNet-pretrained end-to-end model (ResNet18) baselineAUC0.775fine-tuned · backbone=ResNet18 · labeled-data-fraction=0.1%MoCo-CXR: MoCo Pretraining Improves Representation and Transferability of Chest X-ray Models
Source quote
L78: We found that MoCo-CXR-pretrained end-to-end models outperform their ImageNet-pretrained counterparts more at small label fractions than at larger label fractions. With the 0.1% label fraction, the ResNet18 MoCo-CXR-pretrained end-to-end model achieved an AUC of 0.813 while the ImageNet-pretrained end-to-end model achieves an AUC of 0.775, yielding a statistically significant AUC improvement of 0.037 (95% CI 0.015, 0.062). The AUC improvement with the 1.0% label fraction was also statistically significant at 0.027 (95% CI 0.006, 0.047). Both pretraining approaches converge to an AUC of 0.942 with the 100% label fraction.
2019Learning to Transfer Learn (L2TL) proposedMean AUC90.0fine-tuned · metric_aggregation=mean AUC over five classes · uncertain_examples=treated as positiveLearning to Transfer Learn
Source quote
L353: Our L2TL │ 86.1 │ 84.4 │ 91.5 │ 94.8 │ 93.2 │ 90.0
2019Fine-tuning baselineMean AUC89.3fine-tuned · metric_aggregation=mean AUC over five classes · uncertain_examples=treated as positiveLearning to Transfer Learn
Source quote
L351: Fine-tuning │ 85.2 │ 83.8 │ 90.0 │ 94.5 │ 92.8 │ 89.3