CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 2 of 2 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2020ResNet-18 with weak augmentation, mixup, and confidence tempering (CT) proposedW-AUC0.833few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=withSelf-Training with Improved Regularization for Few-Shot Chest X-Ray Classification
Source quote
L164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations.
2020ResNet-18 with weak augmentation and mixup, without confidence tempering ablationW-AUC0.819few-shot · backbone=ResNet-18 · labeled-samples=12500 · confidence-tempering=withoutSelf-Training with Improved Regularization for Few-Shot Chest X-Ray Classification
Source quote
L164: Mixup and confidence tempering provide significant gains. We find that the CT regularization, when combined with mixup and weak augmentation, produces crucial performance gains. For example, when N_\ell=12500, W-AUC increases from 0.819 to 0.833 and W-PRC from 0.64 to 0.673. CT also improves the AUC for classes with low support while not compromising on those with high support. From the saliency maps for detecting different conditions in Figure \ref{fig:gradcam}, we find that the CT regularization leads to non-trivial probabilities even for negative findings, however, the evidences are from irrelevant parts of the image (e.g. organ boundary) thereby avoiding spurious correlations.