CheXpert
131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | final model (ensemble of the best performing networks) SOTA frontier | 0.94 | 2021-01-01 | labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensemble · Mean over 5 selected pathologies; validation studies use the majority vote of 3 board… | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteThe chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2 | DenseNet121-MaxAUC | 0.935 | 2023-01-01 | subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGrad · Mean across Cardiomegaly, Edema, Consolidation, Atelectasis, and Pleural Effusion. Ma… | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteDenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935 |
| 3 | FDAM (DenseNet161) (+1 variant) | 0.9333 | 2021-01-01 | K=2; training uses CheXpert and ChestXray8 data. Evaluated on CheXpert validation dat… | Federated Deep AUC Maximization for Hetergeneous Data with a Constant Communication ComplexitySource quote0.9333 |
| 4 | Proposed MARL framework (Ours, ResNet) | 0.925 | 2023-01-01 | backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1 · Validation set; mean over the five competition-task pathologies. Uncertain labels map… | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925 |
| 5 | Proposed instrumental variable learning framework | 0.923 | 2023-01-01 | uncertain-labels=mapped-to-1 · Average across five competition-task pathologies; the evaluation section states uncer… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923 |
Showing 12 of 12 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | DLDM (disentangled latent diffusion model) proposed | Effectiveness Accuracy | 88.7% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL558: DLDM │ 88.7 │ 91.8 │ 93.3 |
| 2025 | RR-ClArC (ResNet50) proposed | Accuracy (biased) | 0.79 | split: test · artifact=brightness · backbone=ResNet-50 | Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated dataSource quoteL1119: RR-ClArC │ {0.86} \,|\, {0.97} \,|\, {0.82} │ 0.76 \,|\, 0.96 \,|\, 0.79 │ 0.42 \,|\, {0.34} \,|\, - │ 0.00 \,|\, 0.07 \,|\, 0.00 |
| 2025 | U-Net + Text Encoder fine-tuning proposed | Accuracy | 94.8% | split: test · subset=No Finding · resolution=512×512 | Pixels Under Pressure: Exploring Fine-Tuning Paradigms for Foundation Models in High-Resolution Medical ImagingSource quoteL156: When evaluated on real test images after training on synthetic data (Table~\ref{tab:model_accuracy}), models fine-tuned on both U-Net and Text Encoder achieve the highest accuracy across nearly all disease categories (e.g., 77.9% for Cardiomegaly, 94.8% for No Finding), highlighting strong generalization. BitFit also performs surprisingly well in this evaluation, suggesting that while it may underperform in generation quality, its generated images still retain enough semantic structure to be informative for downstream classification. LoRA and DoRA also demonstrate robust cross-domain transfer, particularly in high-signal classes such as Pneumothorax and No Finding, underscoring their utility as efficient yet effective fine-tuning alternatives. |
| 2025 | CLDM (standard conditional latent diffusion model) baseline | Effectiveness Accuracy | 83.5% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL557: CLDM │ 83.5 │ 87.2 │ 89.1 |
| 2025 | GLoRIA baseline | Average accuracy | 50.00% | split: test · fine-tuned · tasks=Consolidation; Pleural Effusion · image-view=frontal | Enhancing Biomedical Multi-modal Representation Learning with Multi-scale Pre-training and Perturbed Report DiscriminationSource quoteL142: GLoRIA \cite{huang2021gloria} │ 71.11% │ 28.89% │ 50.00% |
| 2025 | Vanilla (ResNet50) baseline | Accuracy (biased) | 0.44 | split: test · artifact=brightness · backbone=ResNet-50 | Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated dataSource quoteL1115: Vanilla │ {0.87} \,|\, {0.97} \,|\, {0.81} │ {0.28} \,|\, {0.62} \,|\, {0.44} │ {0.55} \,|\, {0.51} \,|\, - │ {0.17} \,|\, {0.30} \,|\, {0.33} |
| 2025 | Baseline (ResNet50) baseline | Worst-group accuracy (WGAcc) | 25.87% | split: test · folds=4 held-out · backbone=ResNet50 · evaluation=test-time attenuation | Localising Shortcut Learning in Pixel Space via Ordinal Scoring Correlations for Attribution Representations (OSCAR)Source quoteL590: ResNet50 │ CheXpert │ Baseline │ 65.61 │ 25.87 |
| 2024 | Fair Diagnosis (ResNet50) proposed | ACC | 86.40% | split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34 |
| 2024 | \imgedit (white-box) proposed | Acc | 75.1 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | Batch Samp. baseline | Acc | 74.3 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0 |
| 2021 | CheXpert symbol proposed | Accuracy | 77.35% | split: test · backbone=ResNet50 · test_samples=234 · vocabulary_size=100 | Emergent Symbolic Language Based Deep Medical Image ClassificationSource quoteL105: 77.35 |
| 2021 | CheXpert baseline ablation | Accuracy | 73.07% | split: test · test_samples=234 · representation=continuous 2048-dimensional ResNet | Emergent Symbolic Language Based Deep Medical Image ClassificationSource quoteL101: 73.07 |