| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | final model (ensemble of the best performing networks) SOTA frontier | 0.94 | 2021-01-01 | labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensemble · Mean over 5 selected pathologies; validation studies use the majority vote of 3 board… | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteThe chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2 | DenseNet121-MaxAUC | 0.935 | 2023-01-01 | subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGrad · Mean across Cardiomegaly, Edema, Consolidation, Atelectasis, and Pleural Effusion. Ma… | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteDenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935 |
| 3 | FDAM (DenseNet161) (+1 variant) | 0.9333 | 2021-01-01 | K=2; training uses CheXpert and ChestXray8 data. Evaluated on CheXpert validation dat… | Federated Deep AUC Maximization for Hetergeneous Data with a Constant Communication ComplexitySource quote0.9333 |
| 4 | Proposed MARL framework (Ours, ResNet) | 0.925 | 2023-01-01 | backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1 · Validation set; mean over the five competition-task pathologies. Uncertain labels map… | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925 |
| 5 | Proposed instrumental variable learning framework | 0.923 | 2023-01-01 | uncertain-labels=mapped-to-1 · Average across five competition-task pathologies; the evaluation section states uncer… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923 |
Showing 24 of 24 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MedCLIP + GazeWorld proposed | Accuracy | 59.42 | 0-shot · subset=5×200 | A World Model of Radiologist Reading for Medical Image Representation LearningSource quoteL682: 58.13 │ 59.42 │ 56.85 |
| 2025 | DLDM (disentangled latent diffusion model) proposed | Effectiveness Accuracy | 88.7% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL558: DLDM │ 88.7 │ 91.8 │ 93.3 |
| 2025 | MedImageInsight zero-shot proposed | Acc | 80.5% | 0-shot · prompt=Impression | Beyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray PopulationsSource quoteL101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62). |
| 2025 | Pragmatic listener (trained with pragmatic speaker, α=0.2) proposed | Listener accuracy | 98.72% | claims=4 · classes=2 · speaker-gamma=0.4 · candidate-utterances=4 · explanations-per-input=8 | Aligning Explanations with Human CommunicationSource quoteL121: CheXpert │ 2 │ 78.21% │ 4 │ 84.62% │ 98.72% |
| 2025 | ALTA proposed | Accuracy | 56.6% | 0-shot · subset=5×200 · resolution=224 | Efficient Medical Vision-Language Alignment Through Adapting Masked Vision ModelsSource quoteL286: Our ALTA │ 224 │ 83.2 │ 77.9 │ 91.0 │ 56.6 |
| 2025 | Stable Diffusion proposed | classification accuracy | 95% | retained-coverage=55% · uncertainty-filtered=45% of most uncertain samples removed | Conditional Diffusion Models are Medical Image Classifiers that Provide Explainability and Uncertainty for FreeSource quoteL16: In this work, we present a comprehensive evaluation of how conditional diffusion models can be re-purposed and leveraged for image classification, explainability, and uncertainty estimation in the medical domain. First, we propose a novel majority voting-based method that improves the performance of diffusion classifiers in medical imaging. We then demonstrate that classifiers derived from foundation and trained-from-scratch diffusion models perform competitively with state-of-the-art medical image discriminative classifiers through extensive experiments on the publicly available CheXpert~\cite{irvin2019chexpert} and ISIC Melanoma skin cancer~\cite{Rotemberg2020APD} datasets, despite not being trained for classification. Next, we show that diffusion classifiers offer explainability (via counterfactual generation) and uncertainty quantification (via entropy) out-of-the-box. We validate the uncertainty by showing that when the model is confident, it is correct, and vice versa. This is shown as model accuracy drastically improves as its uncertainty threshold increases. For example, Stable Diffusion reaches classification accuracies of 100% and 95% on ISIC and CheXpert, respectively, with only 45% of its most uncertain samples filtered out. |
| 2025 | RR-ClArC (ResNet50) proposed | Accuracy (biased) | 0.79 | split: test · artifact=brightness · backbone=ResNet-50 | Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated dataSource quoteL1119: RR-ClArC │ {0.86} \,|\, {0.97} \,|\, {0.82} │ 0.76 \,|\, 0.96 \,|\, 0.79 │ 0.42 \,|\, {0.34} \,|\, - │ 0.00 \,|\, 0.07 \,|\, 0.00 |
| 2025 | U-Net + Text Encoder fine-tuning proposed | Accuracy | 94.8% | split: test · subset=No Finding · resolution=512×512 | Pixels Under Pressure: Exploring Fine-Tuning Paradigms for Foundation Models in High-Resolution Medical ImagingSource quoteL156: When evaluated on real test images after training on synthetic data (Table~\ref{tab:model_accuracy}), models fine-tuned on both U-Net and Text Encoder achieve the highest accuracy across nearly all disease categories (e.g., 77.9% for Cardiomegaly, 94.8% for No Finding), highlighting strong generalization. BitFit also performs surprisingly well in this evaluation, suggesting that while it may underperform in generation quality, its generated images still retain enough semantic structure to be informative for downstream classification. LoRA and DoRA also demonstrate robust cross-domain transfer, particularly in high-signal classes such as Pneumothorax and No Finding, underscoring their utility as efficient yet effective fine-tuning alternatives. |
| 2025 | CLIP fine-tuned with Palm2-bison fine-grained captions proposed | average per-class accuracy (Avg) | 72.5% | 0-shot · backbone=CLIP · caption-source=Palm2-bison · caption-granularity=fine | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL116: Palm2-bison~\cite{anil2023palm} │ fine │ 74.6 │ 70.7 │ 72.4 │ 77.6 │ 56.9 │ 84.5 │ 70.3 │ 80.2 │ 93.1 │ 37.1 │ 79.7 │ 72.5 |
| 2025 | CLIP fine-tuned with Zephyr-7b coarse-grained captions proposed | average per-class accuracy (Avg) | 53.2% | 0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=coarse | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL127: coarse │ 65.9 │ 41.8 │ 78.9 │ 56.9 │ 42.7 │ 85.8 │ 49.1 │ 71.6 │ 85.8 │ 3.4 │ 3.4 │ 53.2 |
| 2025 | CLIP fine-tuned with Zephyr-7b medium-grained captions proposed | average per-class accuracy (Avg) | 56.8% | 0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=medium | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL126: medium │ 66.4 │ 40.5 │ 82.8 │ 81.5 │ 48.7 │ 85.3 │ 46.1 │ 71.6 │ 85.3 │ 3.9 │ 12.9 │ 56.8 |
| 2025 | CLIP fine-tuned with Zephyr-7b fine-grained captions proposed | average per-class accuracy (Avg) | 64.1% | 0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=fine | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL125: \multirow[t]{3}{*}{zephyr-7b~\cite{tunstall2023zephyr}} │ fine │ 67.7 │ 43.1 │ 60.3 │ 60.3 │ 56.5 │ 83.2 │ 78.4 │ 79.3 │ 86.2 │ 62.5 │ 28.0 │ 64.1 |
| 2024 | HybridMED proposed | Acc | 0.448 | 0-shot · subset=5×200 · pretraining-dataset=MIMIC-CXR | Advancing Medical Radiograph Representation Learning: A Hybrid Pre-training Paradigm with Multilevel Semantic GranularitySource quoteL201: Ours │ MIMIC-CXR │ 0.800 │ 0.448 |
| 2024 | EGMA proposed | Acc. | 60.50 | 0-shot · subset=5x200 | Eye-gaze Guided Multi-modal Alignment for Medical Representation LearningSource quoteL293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46 |
| 2024 | Fair Diagnosis (ResNet50) proposed | ACC | 86.40% | split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34 |
| 2024 | \imgedit (white-box) proposed | Acc | 75.1 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | UniMed-CLIP proposed non-standard slice | ACC | 65.90 | 0-shot · subset=5x200 · backbone=CLIP | UniMed-CLIP: Towards a Unified Image-Text Pretraining Paradigm for Diverse Medical Imaging ModalitiesSource quoteL463: UniMed-CLIP │ 65.90 │ 71.65 │ 71.35 │ 66.31 │ 85.82 │ 85.27 │ 37.54 │ 24.43 │ 31.72 |
| 2023 | MGA(text-level) proposed | Acc | 75.06 | view=frontal · averaged_over=8 diseases | MGA: Medical generalist agent through text-guided knowledge transformationSource quoteL114: MGA(text-level) │ 86.48 │ 81.51 │ 71.01 │ \multicolumn{1}{l}{75.06} │ \multicolumn{1}{l}{69.91} │ \multicolumn{1}{l|}{82.32} |
| 2023 | PRIOR proposed | Accuracy | 34.90 | 0-shot · subset=5x200 · ensemble=none · prompting=simple prompt engineering | PRIOR: Prototype Representation Joint Learning from Medical Images and ReportsSource quoteL211: PRIOR (ours) │ \textcolor{red}{\bf{34.90}} │ \textcolor{red}{\bf{30.56}} │ \textcolor{blue}{35.88} |
| 2022 | UnrealNAS-DARTS-RLGD proposed | accuracy | 85.4% | training-strategy=same as Ke et al. · ImageNet-pretraining=no | UnrealNAS: Can We Search Neural Architectures with Unreal Data?Source quoteL256: UnrealNAS-DARTS-RLGD │ 4.32 │ 85.4 │ 86.1 |
| 2022 | UnrealNAS-DARTS-RLGD proposed | accuracy | 86.1% | training-strategy=same as Ke et al. · ImageNet-pretraining=yes | UnrealNAS: Can We Search Neural Architectures with Unreal Data?Source quoteL256: UnrealNAS-DARTS-RLGD │ 4.32 │ 85.4 │ 86.1 |
| 2021 | Multi-source model fine-tuned locally proposed non-standard slice | Accuracy | 94% | fine-tuned · class=pneumonia · fine-tuning-samples=80 | Deep Learning Models May Spuriously Classify Covid-19 from X-ray Images Based on ConfoundersSource quoteL195: \multirow{1}{*}{Pneumonia} │ Chexpert │ 12% │ 94% |
| 2021 | CheXpert symbol proposed | Accuracy | 77.35% | split: test · backbone=ResNet50 · test_samples=234 · vocabulary_size=100 | Emergent Symbolic Language Based Deep Medical Image ClassificationSource quoteL105: 77.35 |
| 2020 | ReVAE proposed | generation accuracy | 0.516 | supervision-rate=0.004 | Capturing Label Characteristics in VAEsSource quoteL674: \gls{ReVAE} │ 0.513 │ 0.605 │ 0.612 │ 0.596 │ 0.516 │ 0.563 │ 0.549 │ 0.542 |