CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 13 of 13 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MedCLIP + GazeWorld proposedAccuracy59.420-shot · subset=5×200A World Model of Radiologist Reading for Medical Image Representation Learning
Source quote
L682: 58.13 │ 59.42 │ 56.85
2025MedImageInsight zero-shot proposedAcc80.5%0-shot · prompt=ImpressionBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62).
2025ALTA proposedAccuracy56.6%0-shot · subset=5×200 · resolution=224Efficient Medical Vision-Language Alignment Through Adapting Masked Vision Models
Source quote
L286: Our ALTA │ 224 │ 83.2 │ 77.9 │ 91.0 │ 56.6
2025CLIP fine-tuned with Palm2-bison fine-grained captions proposedaverage per-class accuracy (Avg)72.5%0-shot · backbone=CLIP · caption-source=Palm2-bison · caption-granularity=fineEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L116: Palm2-bison~\cite{anil2023palm} │ fine │ 74.6 │ 70.7 │ 72.4 │ 77.6 │ 56.9 │ 84.5 │ 70.3 │ 80.2 │ 93.1 │ 37.1 │ 79.7 │ 72.5
2025CLIP fine-tuned with Zephyr-7b coarse-grained captions proposedaverage per-class accuracy (Avg)53.2%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=coarseEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L127: coarse │ 65.9 │ 41.8 │ 78.9 │ 56.9 │ 42.7 │ 85.8 │ 49.1 │ 71.6 │ 85.8 │ 3.4 │ 3.4 │ 53.2
2025CLIP fine-tuned with Zephyr-7b medium-grained captions proposedaverage per-class accuracy (Avg)56.8%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=mediumEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L126: medium │ 66.4 │ 40.5 │ 82.8 │ 81.5 │ 48.7 │ 85.3 │ 46.1 │ 71.6 │ 85.3 │ 3.9 │ 12.9 │ 56.8
2025CLIP fine-tuned with Zephyr-7b fine-grained captions proposedaverage per-class accuracy (Avg)64.1%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=fineEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L125: \multirow[t]{3}{*}{zephyr-7b~\cite{tunstall2023zephyr}} │ fine │ 67.7 │ 43.1 │ 60.3 │ 60.3 │ 56.5 │ 83.2 │ 78.4 │ 79.3 │ 86.2 │ 62.5 │ 28.0 │ 64.1
2025CLIP fine-tuned using Human Expert captions baselineaverage per-class accuracy (Avg)49.9%0-shot · backbone=CLIP · caption-source=Human ExpertEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L115: Human Expert~\cite{johnson2019mimiccxrjpg} │ 34.5 │ 29.3 │ 64.2 │ 54.7 │ 54.3 │ 56.0 │ 66.8 │ 65.9 │ 44.8 │ 39.7 │ 39.2 │ 49.9
2024HybridMED proposedAcc0.4480-shot · subset=5×200 · pretraining-dataset=MIMIC-CXRAdvancing Medical Radiograph Representation Learning: A Hybrid Pre-training Paradigm with Multilevel Semantic Granularity
Source quote
L201: Ours │ MIMIC-CXR │ 0.800 │ 0.448
2024EGMA proposedAcc.60.500-shot · subset=5x200Eye-gaze Guided Multi-modal Alignment for Medical Representation Learning
Source quote
L293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46
2024UniMed-CLIP proposed non-standard sliceACC65.900-shot · subset=5x200 · backbone=CLIPUniMed-CLIP: Towards a Unified Image-Text Pretraining Paradigm for Diverse Medical Imaging Modalities
Source quote
L463: UniMed-CLIP │ 65.90 │ 71.65 │ 71.35 │ 66.31 │ 85.82 │ 85.27 │ 37.54 │ 24.43 │ 31.72
2023PRIOR proposedAccuracy34.900-shot · subset=5x200 · ensemble=none · prompting=simple prompt engineeringPRIOR: Prototype Representation Joint Learning from Medical Images and Reports
Source quote
L211: PRIOR (ours) │ \textcolor{red}{\bf{34.90}} │ \textcolor{red}{\bf{30.56}} │ \textcolor{blue}{35.88}
2023GLoRIA baselineAccuracy23.200-shot · subset=5x200 · ensemble=none · prompting=simple prompt engineeringPRIOR: Prototype Representation Joint Learning from Medical Images and Reports
Source quote
L210: GLoRIA \cite{huang2021gloria} │ \textcolor{blue}{23.20} │ 15.79 │ \textcolor{red}{\bf{44.01}}