BraTS

93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.91.0201820222025SynNet (Weighted L₂ loss): 0.69 (2018)SynNet (Joint Loss): 0.7 (2018)SynNet (Weighted L₂ loss): 0.77 (2018)SynNet (Joint Loss): 0.86 (2018)ReMIC: 0.9618 (2021)TransCSCN: 0.943 (2022)SyMOT-Flow: 0.83 (2023)MRNet: 0.9411 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 227 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026JiT-L/16 (direct IN transfer) proposedgFID40.17split: test · in-initialized-trainingFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L884: 40.17
2026JiT-B/16 (IN initialization) proposedgFID31.73split: test · fine-tunedFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L865: 31.73
2026MPFlow (full) proposed non-standard sliceDice (\uparrow)0.7400-shot · backbone=Swin-UNet · input-modality=FLAIR · sampling-steps=100 · evaluation-model=Swin-UNetMPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI Reconstruction
Source quote
L290: MPFlow (full) │ \textbf{4.85× 10 (-4)} │ 0.740
2026VariaFlow proposedAUROC0.78split: test · cross-domainVariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection
Source quote
L34: the highest AUROC (0.94, 0.80, 0.78) on each and the high-
2026SynerMedGen (Stage I+II) proposedSSIM90.62modality=FL.→T1SynerMedGen: Synergizing Medical Multimodal Understanding with Generation via Task Alignment
Source quote
L733: 90.62+9.28
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposedMean PSNR27.3 dBsplit: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposedMean SSIM0.95split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2026MRIComp4Flow WFM trained on JPEG2000-compressed data at 200:1 proposedPSNR24.65 dBsplit: val · modality=T1n · compression=JPEG2000 200:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L125: 200 │ 23.25 │ 24.65 │ 23.07 │ 22.63 │ 0.879 │ 0.968 │ 0.937 │ 0.902
2026MRIComp4Flow WFM trained on JPEG2000-compressed data at 400:1 proposedPSNR20.94 dBsplit: val · modality=T1n · compression=JPEG2000 400:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L126: 400 │ 19.30 │ 20.94 │ 21.29 │ 17.18 │ 0.852 │ 0.829 │ 0.814 │ 0.750
2026Transfer-Aware proposedDice55.1%fine-tuned · modality=Brain T1Knowledge Transfer Scaling Laws for 3D Medical Imaging
Source quote
L468: The same trend holds for dense prediction. On AMOS, Transfer-Aware achieves 83.1 Dice on abdominal CT and 69.4 Dice on abdominal MRI, outperforming Data-Proportional by 1.5 and 0.6 points, respectively. The gains are larger on brain and head-and-neck tasks. On BraTS, Transfer-Aware improves over Data-Proportional from 50.4 to 55.1 Dice on Brain T1 and from 61.4 to 65.4 Dice on Brain T2. On head-and-neck CT segmentation, Transfer-Aware improves HECKTOR from 67.8 to 71.1 Dice and BHSD from 57.2 to 61.2 Dice. Across all six segmentation tasks, Transfer-Aware yields the best performance among the compared pretraining strategies.
2026SynerMedGen-UCG (Stage II) ablationSSIM81.34variant=Stage II only · modality=FL.→T1SynerMedGen: Synergizing Medical Multimodal Understanding with Generation via Task Alignment
Source quote
L719: 81.34
2026GALoss[11] (ECCV 2024)Dice83.49%split: testScale-aware adaptive supervised network with limited medical annotations
Source quote
L1314: 83.49
2026SASNetDice85.84%split: testScale-aware adaptive supervised network with limited medical annotations
Source quote
L1321: 85.84
2026JiT-B/16 (random initialization; RADIN-pretrained) baselinegFID36.73split: test · medical-pretrained-then-fine-tunedFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L853: 36.73
2026JiT-L/16 (single-channel BRATS-pretrained) baselinegFID50.90split: test · medical-pretrainedFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L880: 50.90
2026JiT-L/16 (RADIN-pretrained) baselinegFID75.40split: test · medical-pretrainedFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L876: 75.40
2026DynamicDPS baseline non-standard sliceDice (\uparrow)0.6390-shot · backbone=Swin-UNet · input-modality=FLAIR · sampling-steps=100 · evaluation-model=Swin-UNetMPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI Reconstruction
Source quote
L288: DynamicDPS │ 4.51× 10 (-2) │ 0.639
2026REFLECT baselineAUROC0.6828split: test · cross-domainVariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection
Source quote
L680: 0.6828 AUROC on BraTS. IterMask2 shows a similar trend,
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baselineMean PSNR27.0 dBsplit: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressedMRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baselineMean SSIM0.96split: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressedMRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2026Data-Proportional baselineDice50.4%fine-tuned · modality=Brain T1Knowledge Transfer Scaling Laws for 3D Medical Imaging
Source quote
L468: The same trend holds for dense prediction. On AMOS, Transfer-Aware achieves 83.1 Dice on abdominal CT and 69.4 Dice on abdominal MRI, outperforming Data-Proportional by 1.5 and 0.6 points, respectively. The gains are larger on brain and head-and-neck tasks. On BraTS, Transfer-Aware improves over Data-Proportional from 50.4 to 55.1 Dice on Brain T1 and from 61.4 to 65.4 Dice on Brain T2. On head-and-neck CT segmentation, Transfer-Aware improves HECKTOR from 67.8 to 71.1 Dice and BHSD from 57.2 to 61.2 Dice. Across all six segmentation tasks, Transfer-Aware yields the best performance among the compared pretraining strategies.
2025MAD-AD proposedModality (Max Dice)70.3setting=S2 · modalities=FLAIR, T1CE, T2-w, T1-w · aggregation=averageMAD-AD: Masked Diffusion for Unsupervised Brain Anomaly Detection
Source quote
L178: MAD-AD (Ours) │ 76.2\worse{-4.0} │ 68.5\imp{+6.8} │ 73.2\imp{+2.0} │ 63.4\imp{+4.9} │ 70.3\imp{+2.4}
2025fastWDM3D (T=2) proposedAST (average sampling time per volume)1.81 ssplit: test · sampling-steps=2fastWDM3D: Fast and Accurate 3D Healthy Tissue Inpainting
Source quote
L134: Ours (fastWDM3D (T=2)) │ 0.86 ± 0.12 │ 0.0079 ± 0.0063 │ 22.26 ± 3.97 │ \hphantom{0}\SI{1.81}{\second}
2025UniFS proposedPSNR improvement over FSMNet1.06dBacceleration=4× · undersampling-patterns=3UniFS: Unified Multi-Contrast MRI Reconstruction via Frequency-Spatial Fusion
Source quote
L176: As shown in Table \ref{tab1}, UniFS consistently outperforms all competing methods in terms of image reconstruction quality. Compared with the current leading method FSMNet \cite{FSMNet}, which also incorporates frequency feature fusion, UniFS achieves significant PSNR improvements of 1.06dB and 2.00dB under 4× acceleration on the BraTs and HCP datasets. These results highlight the effectiveness of the enhanced frequency fusion design within the CMF module. Furthermore, Fig. \ref{fig2} shows reconstructed images and corresponding error maps from different methods. The zoomed-in views reveal that UniFS achieves more accurate texture recovery, while the noticeably smaller error maps further confirm its superior reconstruction fidelity.
2025IterMask3D proposedDSC69.7split: test · test-time-refinement · tuning=test-set, 3 standard deviations · modality=FLAIR · training-data=cognitively normal ADNI/OASIS · dimensionality=3DIterMask3D: Unsupervised Anomaly Detection and Segmentation with Test-Time Iterative Mask Refinement in 3D Brain MR
Source quote
L534: \multicolumn{1}{l|}{IterMask3D} │ 69.7 │ 99.2 │ 72.7 │ 71.1 │ 56.7 │ 32.2 │ 5.1
2025OAIMS proposedDice74.6clicks=10 · modality=T1 · incorrect-clicks=40%You Point, I Learn: Online Adaptation of Interactive Segmentation Models for Handling Distribution Shifts in Medical Imaging
Source quote
L668: OAIMS │ 67.8 │ 71.8 │ 74.6
2025MTMed3D (Avg.) proposed[email protected]:0.50.9082aggregation=averageMTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging
Source quote
L232: 0.9082 │ 0.9357 │ 0.8955
2025MTMed3D (Avg.) proposed[email protected]:0.50.9357aggregation=averageMTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging
Source quote
L232: 0.9082 │ 0.9357 │ 0.8955
2025AugPaint proposedDice35.19%semi-supervised · analysis=mask-flipping · labeled-cases=1Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image Segmentation
Source quote
L333: AugPaint │ 35.19 │ 62.33 │ 41.85 │ 38.43
2025SIPL proposedDSC83.0%split: test · regions=whole tumor, enhancing tumor, tumor core · train-val-test-split=80:5:15Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype Learning
Source quote
L197: SIPL (ours) │ 83.0 │ --
2025Ours-PL proposedDice (%) average59.37%unsupervised-domain-adaptation · source_domain=T2 · target_domain=FlairBézier Meets Diffusion: Robust Generation Across Domains for Medical Image Segmentation
Source quote
L430: Ours-PL │ 71.70 │ \bf 65.42 │ \bf 41.00 │ \bf 59.37 │ 22.59 │ 19.98 │ 25.89 │ 22.82
2025Ours-AD proposed95HD average18.81unsupervised-domain-adaptation · source_domain=T2 · target_domain=FlairBézier Meets Diffusion: Robust Generation Across Domains for Medical Image Segmentation
Source quote
L428: Ours-AD │ 73.74 │ 62.30 │ 39.80 │ 58.61 │ 12.44 │ \bf 18.58 │ \bf 25.42 │ \bf 18.81
2025VIViT+SSL proposedMean Dice0.883split: test · resolution=128×128×128VIViT: Variable-Input Vision Transformer Framework for 3D MR Image Segmentation
Source quote
L130: VIViT+SSL │ 0.624 │ 0.871 │ 0.893 │ 0.884 │ 0.883
2025Expert-guided explainable few-shot learning (guided model) proposedAccuracy83.61%few-shot · epoch=7 · episodes=60 · explanation-weight-alpha=0.10Expert-Guided Explainable Few-Shot Learning for Medical Image Diagnosis
Source quote
L107: 7 │ 60 │ 83.61 │ 77.09
2025BOGC-MML proposedTop-1 accuracy77.86%available-modality=T1c · missing-modalities=Fl, T1, T2Multi-Modal Learning with Bayesian-Oriented Gradient Calibration
Source quote
L343: 62.02 │ 67.07 │ 72.60 │ 75.65 │ 77.86
2025NAGL proposedaverage AUROC89.5%few-shot · reference_samples=N^2+A^1Normal-Abnormal Guided Generalist Anomaly Detection
Source quote
L228: \paragraph{Generalization.} Our method exhibits superior generalization capabilities compared to ResAD across multiple datasets. On MVTecAD, under the N^1+A^1 setting, our approach achieves 95.7% image F1-max and 58.9% pixel F1-max, outperforming ResAD by 4.5 and 10.7 percentage points, respectively. Similarly, on VisA, we attain 85.4% image F1-max and 41.8% pixel F1-max, exceeding ResAD by 4.1 and 4.0 percentage points. Furthermore, as shown in Tab.~\ref{tab:exp_medical}, our method demonstrates superior cross-domain generalization, achieving 89.5% average AUROC on the BraTS medical dataset with just two normal and one abnormal sample, a 10.6 percentage point improvement over ResAD (78.9% with N^2 setting). Notably, across all other experimental settings, our method consistently outperforms existing approaches in both anomaly detection and segmentation. These results clearly demonstrate the effectiveness of our method in generalist AD.
2025CADD proposed non-standard sliceAverage maximum Dice0.3548fine-tuned · modality=FLAIR · fine-tuning-data=AIBL · clinical-covariates=noneCADD: Context aware disease deviations via restoration of brain images using normative conditional diffusion models
Source quote
L343: Dice (\uparrow) │ 0.3386 │ 0.2619 │ 0.3548
2025Causal-SAM-LLM proposedDice75.7%fine-tuned · evaluation=single-source-domain-generalization · aggregation=three random seeds · training_dataset=BTCV CTCausal-SAM-LLM: Large Language Models as Causal Reasoners for Robust Medical Segmentation
Source quote
L173: Causal-SAM-LLM │ 52.8 │ 83.5 │ 23.4 │ \bfseries 79.5 │ \bfseries 18.9 │ \bfseries 75.7 │ \bfseries 17.6
2025Causal-SAM-LLM proposedHD9517.6 mmfine-tuned · evaluation=single-source-domain-generalization · aggregation=three random seeds · training_dataset=BTCV CTCausal-SAM-LLM: Large Language Models as Causal Reasoners for Robust Medical Segmentation
Source quote
L173: Causal-SAM-LLM │ 52.8 │ 83.5 │ 23.4 │ \bfseries 79.5 │ \bfseries 18.9 │ \bfseries 75.7 │ \bfseries 17.6
2025FgC2F-UDiff (Our method) proposedPSNR26.34 dBsynthesis=many-to-one · target-modality=T1ce · input-modalities=T1,T2FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI Synthesis
Source quote
L312: \multirow{2}{*}{Our method} │ 26.34 │ 0.894 │ 17.45 │ 20.85 │ 27.19 │ 0.937 │ 16.14 │ 18.74
2025SpectMamba proposedmAP75.34split: test · epochs=200 · pretraining=noneSpectMamba: Integrating Frequency and State Space Models for Enhanced Medical Image Detection
Source quote
L275: {SpectMamba} │ 89.83 │ 78.64 │ 57.54 │ 75.34 │ 95.35 │ 85.64 │ 68.24 │ 83.08
2025Single-task (Avg.) ablation[email protected]:0.50.8217aggregation=averageMTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging
Source quote
L237: 0.8217 │ 0.8608 │ 0.8474
2025Single-task (Avg.) ablation[email protected]:0.50.8608aggregation=averageMTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging
Source quote
L237: 0.8217 │ 0.8608 │ 0.8474
2025AugPaint with flipped mask ablationDice36.27%semi-supervised · labeled-cases=1 · mask-condition=randomly flipped vertically and horizontallyInpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image Segmentation
Source quote
L334: + flipping │ 36.27(+1.08) │ 48.38(-13.95) │ 43.11(+1.26) │ 35.22(-3.21)
2025Boundary Blur (σ=3) perturbation ablationEvanyseg score0.845sigma=3 · perturbation=boundary blur · segmentation-model=EvanysegMetrics that matter: Evaluating image quality metrics for medical image generation
Source quote
L315: \quad \sigma=3 │ 0.845
2025Ours-Bézier ablationDice (%) average58.16%unsupervised-domain-adaptation · target_domain=T1CBézier Meets Diffusion: Robust Generation Across Domains for Medical Image Segmentation
Source quote
L330: \bf Ours-Bézier │ \bf 62.47 │ \bf 67.89 │ \bf 44.12 │ \bf 58.16 │ \bf 20.89 │ \bf 23.07 │ \bf 27.84 │ \bf 23.93
2025Non-guided model ablationAccuracy77.09%few-shot · epoch=7 · episodes=60 · explanation-weight-alpha=0.10Expert-Guided Explainable Few-Shot Learning for Medical Image Diagnosis
Source quote
L107: 7 │ 60 │ 83.61 │ 77.09
2025IterMask^2 baselineModality (Max Dice)67.9setting=S2 · modalities=FLAIR, T1CE, T2-w, T1-w · aggregation=averageMAD-AD: Masked Diffusion for Unsupervised Brain Anomaly Detection
Source quote
L176: IterMask^2~\cite{liang2024itermask2}_{\textsl {MICCAI'24}} │ 80.2 │ 61.7 │ 71.2 │ 58.5 │ 67.9
2025WDM3D baselineAST (average sampling time per volume)5 minutesplit: test · loss=MSE on wavelet coefficients · sampling-steps=1000 · variance-schedule=linearfastWDM3D: Fast and Accurate 3D Healthy Tissue Inpainting
Source quote
L133: WDM3D \cite{durrer2024denoising} │ 0.61 ± 0.16 │ 0.1060 ± 0.0757 │ 10.57 ± 3.20 │ \hphantom{0}\SI{5}{\minute}
2025DAE (tuned) baselineDSC66.7split: test · test-time-tuned · tuning=test-set, 3 standard deviations · modality=FLAIR · dimensionality=3DIterMask3D: Unsupervised Anomaly Detection and Segmentation with Test-Time Iterative Mask Refinement in 3D Brain MR
Source quote
L533: \multicolumn{1}{l|}{DAE (tuned)} │ 66.7 │ 99.1 │ 71.1 │ 68.7 │ 52.5 │ 34.5 │ 6.2
2025FullGrad (DeiT-S) baselineDSC33.2%weakly-supervised · target=whole-tumor · backbone=DeiT-S · modality=T2 FLAIRHybrid Transformer-Mamba Architecture for Weakly Supervised Volumetric Medical Segmentation
Source quote
L191: FullGrad \cite{srinivas2019full} │ DeiT-S │ 4.0 │ 33.2 (7) │ 5.1 (7) │ 19.8 (8) │ 20.5 (3) │ 16.3 (3) │ 25.1 (2) │ 37.7 (2) │ 4.3 (2) │ 23.1 (2)
2025ICNN* baselineDice43.9clicks=10 · modality=T1 · incorrect-clicks=40%You Point, I Learn: Online Adaptation of Interactive Segmentation Models for Handling Distribution Shifts in Medical Imaging
Source quote
L667: \multirow{2}{*}{\shortstack[l]{40% clicks\\are wrong}} │ ICNN (*) │ 20.6 │ 32.9 │ 43.9
2025UNETR++ baselineDSC82.8%split: test · regions=whole tumor, enhancing tumor, tumor core · train-val-test-split=80:5:15Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype Learning
Source quote
L196: UNETR++ │ 82.8 │ 0.0297
2025GAN baselineEvanyseg Dice score0.56segmentation-model=EvanysegMetrics that matter: Evaluating image quality metrics for medical image generation
Source quote
L399: GAN │ 0.67 │ 0.56
2025DDPM baselineEvanyseg Dice score0.78segmentation-model=EvanysegMetrics that matter: Evaluating image quality metrics for medical image generation
Source quote
L400: DDPM │ 0.91 │ 0.78
2025ADVENT baselineDice (%) average57.88%unsupervised-domain-adaptation · source_domain=T2 · target_domain=FlairBézier Meets Diffusion: Robust Generation Across Domains for Medical Image Segmentation
Source quote
L421: ADVENT │ 75.95 │ 60.16 │ 37.52 │ 57.88 │ 14.38 │ 22.11 │ 26.44 │ 20.98
2025ADVENT baseline95HD average20.98unsupervised-domain-adaptation · source_domain=T2 · target_domain=FlairBézier Meets Diffusion: Robust Generation Across Domains for Medical Image Segmentation
Source quote
L421: ADVENT │ 75.95 │ 60.16 │ 37.52 │ 57.88 │ 14.38 │ 22.11 │ 26.44 │ 20.98
2025CyCADA baselineDice (%) average48.76%unsupervised-domain-adaptation · target_domain=T1CBézier Meets Diffusion: Robust Generation Across Domains for Medical Image Segmentation
Source quote
L327: CyCADA │ 57.25 │ 58.15 │ 30.89 │ 48.76 │ 29.15 │ 33.90 │ 38.92 │ 33.99
2025SwinUNETR baselineMean Dice0.874split: testVIViT: Variable-Input Vision Transformer Framework for 3D MR Image Segmentation
Source quote
L126: SwinUNETR │ 0.611 │ 0.873 │ 0.883 │ 0.867 │ 0.874
2025ResAD baselineaverage AUROC78.9%few-shot · reference_samples=N^2Normal-Abnormal Guided Generalist Anomaly Detection
Source quote
L228: \paragraph{Generalization.} Our method exhibits superior generalization capabilities compared to ResAD across multiple datasets. On MVTecAD, under the N^1+A^1 setting, our approach achieves 95.7% image F1-max and 58.9% pixel F1-max, outperforming ResAD by 4.5 and 10.7 percentage points, respectively. Similarly, on VisA, we attain 85.4% image F1-max and 41.8% pixel F1-max, exceeding ResAD by 4.1 and 4.0 percentage points. Furthermore, as shown in Tab.~\ref{tab:exp_medical}, our method demonstrates superior cross-domain generalization, achieving 89.5% average AUROC on the BraTS medical dataset with just two normal and one abnormal sample, a 10.6 percentage point improvement over ResAD (78.9% with N^2 setting). Notably, across all other experimental settings, our method consistently outperforms existing approaches in both anomaly detection and segmentation. These results clearly demonstrate the effectiveness of our method in generalist AD.
2025AutoDDPM (3D) baseline non-standard sliceAverage maximum Dice0.3386fine-tuned · model=AutoDDPM (3D) · modality=FLAIR · fine-tuning-data=AIBL · clinical-covariates=noneCADD: Context aware disease deviations via restoration of brain images using normative conditional diffusion models
Source quote
L343: Dice (\uparrow) │ 0.3386 │ 0.2619 │ 0.3548
2025MoME baselineDICE92.10dataset-version=2021Brain Imaging Foundation Models, Are We There Yet? A Systematic Review of Foundation Models for Brain Imaging and Biomedical Research
Source quote
L445: MoME │ 2021 │ 92.10
2025BrainSegFounder baselineDICE91.15dataset-version=2023Brain Imaging Foundation Models, Are We There Yet? A Systematic Review of Foundation Models for Brain Imaging and Biomedical Research
Source quote
L448: BrainSegFounder │ 2023 │ 91.15
2025ShapePU baselineDice0.057scribble-supervised · annotation=scribblesRevisiting 3D Medical Scribble Supervision: Benchmarking Beyond Cardiac Segmentation
Source quote
L113: 0.057
2025Uni-GAN baselinePSNR25.57 dBsynthesis=many-to-one · target-modality=T1ce · input-modalities=T1,T2FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI Synthesis
Source quote
L308: \multirow{2}{*}{Uni-GAN} │ 25.57 │ 0.886 │ 18.13 │ 21.77 │ 26.54 │ 0.930 │ 16.97 │ 20.07
2024QCResUNet proposedPearson r (DSC prediction)0.968split: test · metric-target=DSC · prediction-level=subject-level · segmentation-models=nnUNet, nnFormerQCResUNet: Joint subject-level and voxel-level segmentation quality prediction
Source quote
L279: Specifically, on the BraTS internal testing set with segmentations generated by nnUNet and nnFormer, the proposed method achieved a small mean MAE of 0.056 and 0.064 for NSD and DSC prediction, respectively. The predicted NSD and DSC also showed a strong correlation with the corresponding ground truth, achieving Pearson r values of 0.958 and 0.968, respectively. Importantly, the proposed method generalized well for segmentation produced by different methods (i.e., DeepMedic), which had not been used during training, achieving an average MAE of 0.074 and 0.062 for NSD and DSC prediction. Similarly, the predicted NSD and DSC showed a strong correlation with their ground truth with Pearson r values of 0.937 and 0.962, respectively.
2024Domain-Game proposedDice65.05targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1GdDomain Game
Source quote
L263: \ \ \textBF{65.05 \down{13.42}} \ \ │ \ \textBF{59.53 \down{15.95}}
2024Domain-Game proposedJaccard59.53targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1GdDomain Game
Source quote
L263: \ \ \textBF{65.05 \down{13.42}} \ \ │ \ \textBF{59.53 \down{15.95}}
2024McCaD proposedDice score0.8004split: test · retained-contrasts=T1w, FLAIR · synthetic-contrast=T2w · segmentation-target=whole-tumorMcCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI Synthesis
Source quote
L210: AttGAN │ DDPM │ Hi-Net │ MM-GAN │ McCaD │ Complete T2w │ 0.7692 │ 0.7987 │ 0.7921 │ 0.7991 │ 0.8004 │ 0.8188 T2w + FLAIR │ 0.6974 │ 0.6262 │ 0.7401 │ 0.7449 │ 0.7602 │ 0.8188
2024HF-GAN proposedPSNR30.27aggregation=average across missing-sequence scenarios · architecture=2D slice-basedPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately.
2024HF-GAN proposedSSIM0.9393aggregation=average across missing-sequence scenarios · architecture=2D slice-basedPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately.
2024HF-GAN (ours) imputation proposedDice (ET)0.6438split: test · evaluation=after imputation · architecture=2D slice-based · test-subjects=85 · segmentation-region=ETPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L284: \multicolumn{4}{c|}{Average} │ 0.6196* (0.3202) │ 0.5130* (0.3041) │ 0.4957* (0.3598) │ 0.8436* (0.1279) │ 0.7247* (0.1728) │ 0.6139* (0.3619) │ 0.8405* (0.1356) │ 0.7178* (0.1766) │ 0.6313* (0.3446) │ 0.8632 (0.1033) │ 0.7488 (0.1588) │ 0.6174* (0.3743) │ 0.8618 (0.1071) │ 0.7472 (0.1625) │ 0.6438 (0.3397)
2024MRNet proposedPSNR31.2852split: test · plane=axial · direction=FLAIR-to-T2MRNet: Multifaceted Resilient Networks for Medical Image-to-Image Translation
Source quote
L269: OURS │ 31.2852 │ 0.9411 │ \checkmark
2024MRNet proposedSSIM0.9411split: test · plane=axial · direction=FLAIR-to-T2MRNet: Multifaceted Resilient Networks for Medical Image-to-Image Translation
Source quote
L269: OURS │ 31.2852 │ 0.9411 │ \checkmark
2024Ours (GAN-based semantic segmentation model) proposedPixel Accuracy0.5821Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state…Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic Segmentation
Source quote
L140: Pixel Accuracy and Recall of these models, the performance of each model in the brain tumor segmentation task can be more comprehensively evaluated. First of all, from the perspective of pixel accuracy (Pixel Accuracy), our model performs best, reaching 0.5821, which is significantly improved compared to other models. Specifically, the pixel accuracy of FCNs is
2024Ours (GAN-based semantic segmentation model) proposedRecall0.5523Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state…Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic Segmentation
Source quote
L143: Secondly, from the perspective of recall index, our model also performed well, reaching 0.5523, which is better than all other comparison models. The recall rate of FCNs is 0.5231,
2024Ours (GAN-based semantic segmentation model) proposedDice0.4433Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state…Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic Segmentation
Source quote
L175: From the perspective of Dice coefficient, our model also performs well, reaching 0.4433, which is higher than all other models. The Dice coefficient of FCNs is 0.4119, SegNet is
2024TrIND (per-sample INR) proposed non-standard sliceRel. Error0.039%Table 2: relative percentage error between reconstructed signal and ground truth; repre…TrIND: Representing Anatomical Trees by Denoising Diffusion of Implicit Neural Fields
Source quote
L225: 0.039
2024TrIND (per-sample INR) proposedINR Size0.753 MBTable 2 reports the INR size for this modality alongside input size; the table evaluate…TrIND: Representing Anatomical Trees by Denoising Diffusion of Implicit Neural Fields
Source quote
L227: 0.753↓×90.45
2024VerSe (Mode-3) proposedDice(10)94.492evaluation=out-of-distribution · interaction=10-clickVerSe: Integrating Multiple Queries as Prompts for Versatile Cardiac MRI Segmentation
Source quote
L270: \texttt{VerSe} (Mode-3) │ 69.516 │ 80.631 │ 11.787 │ 94.492 │ 96.811 │ 2.777
2024VerSe (Mode-3) proposedDice(20)96.811evaluation=out-of-distribution · interaction=20-clickVerSe: Integrating Multiple Queries as Prompts for Versatile Cardiac MRI Segmentation
Source quote
L270: \texttt{VerSe} (Mode-3) │ 69.516 │ 80.631 │ 11.787 │ 94.492 │ 96.811 │ 2.777
2024HiDiff proposed non-standard sliceAverage Dice51.77split: test · subset=small tumors; pixel-wise tumor size <100HiDiff: Hybrid Diffusion Framework for Medical Image Segmentation
Source quote
L506: {{HiDiff}\xspace (ours)} │ 51.77 │ 8.76(20.13%) │ 59.00 │ 47.30 │ 49.00
2024PrimGeoSeg (SwinUNETR; FDSL pre-training) proposedAvg. score90.3fine-tuned · backbone=SwinUNETR · pretraining=FDSLPrimitive Geometry Segment Pre-training for 3D Medical Image Segmentation
Source quote
L305: PrimGeoSeg │ FDSL │ 88.7 │ 85.6 │ 91.8 │ 88.9 │ 90.3 │ 87.0 │ 92.9 │ 91.0 \\[0.8pt]
2024MultiUNet (drop mods) proposedDice0.614input=single-modality · evaluation=held-out-unseen-pathology · modalities=Flair-or-T1Feasibility and benefits of joint learning from MRI databases with different brain diseases and modalities for segmentation
Source quote
L165: MultiUNet (drop mods) │ Flair or T1 │ 0.614 │ 0.454 │ 0.324 │ 0.241 │ 0.540
2024NACL proposedDSC0.850backbone=UNet · training=2D slices · evaluation=3D volumesNeighbor-aware calibration of segmentation networks with penalty-based constraints
Source quote
L238: Mean │ 0.789 │ 6.96 │ \und{0.848} │ 9.00 │ 0.808 │ 8.71 │ 0.820 │ 7.78 │ 0.801 │ 8.44 │ 0.838 │ 7.94 │ 0.850 │ 5.78
2024TrIND (INR representation) proposed non-standard sliceRel. Error0.039%INR reconstruction; relative percentage error between the reconstructed signal and grou…Representing Anatomical Trees by Denoising Diffusion of Implicit Neural Fields
Source quote
L201: BraTS~\cite{menze2014multimodal} │ 0.039 │ 68.11-± 0.00 │ 0.753-\downarrow ×90.45
2024Kaggle duplicate audit proposedDuplicates383 duplicatesplatform=Kaggle · data-collected=October 2024Copycats: the many lives of a publicly available medical imaging dataset
Source quote
L188: BraTS~\cite{menze2014multimodal} │ 383 │ \phantom{0}51.5 GB\textsuperscript{\mathsection} │ \phantom{00}7.3 TB │ 30.0 │ 9 │ 92.4
2024X-Diffusion (1-slice input) proposedTest 3D PSNR23.10split: test · sequence=FLAIR T2 · input-slices=1X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
Source quote
L131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01
2024IBN-Net baselineDice58.39targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1GdDomain Game
Source quote
L239: 58.39 \down{19.55} │ 46.89 \down{27.03}
2024BayeSeg baselineJaccard54.24targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1GdDomain Game
Source quote
L257: 57.39 \down{20.89} │ 54.24 \down{20.59}
2024Complete baseline non-standard sliceDice score0.8188split: test · contrast-input=all three ground-truth contrasts · segmentation-target=whole-tumorMcCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI Synthesis
Source quote
L210: AttGAN │ DDPM │ Hi-Net │ MM-GAN │ McCaD │ Complete T2w │ 0.7692 │ 0.7987 │ 0.7921 │ 0.7991 │ 0.8004 │ 0.8188 T2w + FLAIR │ 0.6974 │ 0.6262 │ 0.7401 │ 0.7449 │ 0.7602 │ 0.8188
2024Hyper-GAE (3D) baselinePSNR29.54evaluation=2D slices · aggregation=average across missing-sequence scenarios · architecture=3DPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately.
2024Hyper-GAE (3D) baselineSSIM0.9361evaluation=2D slices · aggregation=average across missing-sequence scenarios · architecture=3DPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately.
2024Hyper-GAE imputation baselineDice (ET)0.6174split: test · evaluation=after imputation · architecture=3D volumetric · test-subjects=85 · segmentation-region=ETPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L284: \multicolumn{4}{c|}{Average} │ 0.6196* (0.3202) │ 0.5130* (0.3041) │ 0.4957* (0.3598) │ 0.8436* (0.1279) │ 0.7247* (0.1728) │ 0.6139* (0.3619) │ 0.8405* (0.1356) │ 0.7178* (0.1766) │ 0.6313* (0.3446) │ 0.8632 (0.1033) │ 0.7488 (0.1588) │ 0.6174* (0.3743) │ 0.8618 (0.1071) │ 0.7472 (0.1625) │ 0.6438 (0.3397)
2024DeepLab V2 baselinePixel Accuracy0.5732Brain-tumor semantic segmentation on BRATS; compared as a segmentation-model baseline. …Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic Segmentation
Source quote
L141: 0.5321, SegNet is 0.5411, U-Net is 0.5531, while DeepLab V1 and DeepLab V2 are 0.5622 and 0.5732 respectively. It can be seen that our model has improved by 0.0089 compared to
2024DeepLab V2 baselineRecall0.5478Brain-tumor semantic segmentation on BRATS; compared as a segmentation-model baseline. …Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic Segmentation
Source quote
L145: DeepLab V1 and DeepLab V2 are 0.5431 and 0.5478 respectively. The improvement in recall indicates that our model has a higher ability to identify and detect actual brain tumor regions. A higher recall rate is crucial for brain tumor segmentation because it directly affects the detection rate of tumor areas, can reduce the risk of missed detection, and improve the overall recognition ability of tumors. Taking pixel accuracy and recall into account, our model shows clear advantages in both metrics. This not only shows the overall performance improvement of the model in the segmentation task, but also shows that our method achieves a good balance between the capture of fine-grained features and the understanding of global context. The improved model is able to provide more accurate and comprehensive segmentation results when dealing with different regions of brain tumors. The success of our method may be due to innovations in network architecture, loss function design, or training strategies, which enhance the model's expressive ability and generalization ability, resulting in excellent performance in experiments on the BRATS dataset. In order to show our experimental results more intuitively, we use a bar chart to show the results, as shown in Figure 3.
2024Scratch (SwinUNETR; no pre-training) baselineAvg. score90.0fine-tuned · backbone=SwinUNETR · pretraining=nonePrimitive Geometry Segment Pre-training for 3D Medical Image Segmentation
Source quote
L304: Scratch │ -- │ 88.1 │ 84.8 │ 91.3 │ 88.1 │ 90.0 │ 86.8 │ 92.9 │ 90.3
2024DinoV2-L with Rein-Lora baselineDG performance score63.49labels=binary lesion/background · backbone=DinoV2-L · adaptation=Rein-Lora · source-modality=T1w · target-modality=FLAIRDo Vision Foundation Models Enhance Domain Generalization in Medical Image Segmentation?
Source quote
L353: Rein-Lora │ DinoV2-L │ 82.95 │ 63.49
2024Vanilla UNet baselineDG performance score54.84model=Vanilla UNet · labels=binary lesion/background · source-modality=T1w · target-modality=FLAIRDo Vision Foundation Models Enhance Domain Generalization in Medical Image Segmentation?
Source quote
L360: N/A │ Vanilla UNet │ 81.86 │ 54.84
2024DinoV2-L with Rein-Lora baselineDG performance score38.19labels=binary lesion/background · backbone=DinoV2-L · adaptation=Rein-Lora · source-modality=FLAIR · target-modality=T1wDo Vision Foundation Models Enhance Domain Generalization in Medical Image Segmentation?
Source quote
L365: Rein-Lora │ DinoV2-L │ 38.19 │ 91.30
2024Vanilla UNet baselineDG performance score19.79model=Vanilla UNet · labels=binary lesion/background · source-modality=FLAIR · target-modality=T1wDo Vision Foundation Models Enhance Domain Generalization in Medical Image Segmentation?
Source quote
L372: N/A │ Vanilla UNet │ 19.79 │ 90.48
2024FL baselineDSC0.848backbone=UNet · training=2D slices · evaluation=3D volumesNeighbor-aware calibration of segmentation networks with penalty-based constraints
Source quote
L238: Mean │ 0.789 │ 6.96 │ \und{0.848} │ 9.00 │ 0.808 │ 8.71 │ 0.820 │ 7.78 │ 0.801 │ 8.44 │ 0.838 │ 7.94 │ 0.850 │ 5.78
2024True Data baselineDice72.90%split: test · training-data=realGenerative Enhancement for 3D Medical Images
Source quote
L321: True Data │ 72.90 │ / │ 8.89 │ /
2024True Data baselineHD958.89 mmsplit: test · training-data=realGenerative Enhancement for 3D Medical Images
Source quote
L321: True Data │ 72.90 │ / │ 8.89 │ /
2024Reconstructed Data of Baseline (Make-A-Volume) baselineDice59.70%split: test · data-method=Make-A-Volume · training-data=reconstructedGenerative Enhancement for 3D Medical Images
Source quote
L323: Reconstructed Data of Baseline │ 59.70 │ -13.20 │ 12.44 │ 3.55
2024Reconstructed Data of Baseline (Make-A-Volume) baselineHD9512.44 mmsplit: test · data-method=Make-A-Volume · training-data=reconstructedGenerative Enhancement for 3D Medical Images
Source quote
L323: Reconstructed Data of Baseline │ 59.70 │ -13.20 │ 12.44 │ 3.55
2024MT baselineDice63.52%semi-supervised · labeled-unlabeled=1/249Concatenate, Fine-tuning, Re-training: A SAM-enabled Framework for Semi-supervised 3D Medical Image Segmentation
Source quote
L461: MT \scalebox{0.7}{[NIPS'17]~\cite{tarvainen2017mean}} │ 63.52 │ 50.59 │ 20.59 │ 47.54
2024TPDM (1-slice input) baselineTest 3D PSNR10.48split: test · sequence=FLAIR T2 · input-slices=1X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
Source quote
L130: TPDM \cite{TPDM} │ 10.48 │ 9.29 │ 10.86 │ 9.99 │ 11.33 │ 11.09 │ 14.13 │ 12.62 │ 16.65 │ 15.88 │ 31.48 │ 21.70
2024HA-GAN baselineMS-SSIM0.999Mean MS-SSIM over 1k generated images; resolution is not specified for this score.WDM: 3D Wavelet Diffusion Models for High-Resolution Medical Image Synthesis
Source quote
L130: \subsubsection{Discussion} (1) Our proposed method outperforms HA-GAN \cite{sun2022hierarchical} on both FID and MS-SSIM metrics. While HA-GAN offers a slightly reduced memory footprint at higher resolutions, we found that it tends to suffer from severe mode collapse, indicated by a high MS-SSIM score of 0.999 on BraTS. As HA-GAN does not require iterative sampling, it is the method with the shortest inference time of \SI{0.4}{\second}/\SI{3}{\second} at the respective resolutions.
2023Proposed equality-constraint linear-penalty method on logits (λ=0.1) proposedECE0.112class=foreground · lambda=0.1 · training=2D slices · evaluation=3D volumesTrust your neighbours: Penalty-based constraints for model calibration
Source quote
L178: Ours (\lambda=0.1) │ 0.868 │ 4.88 │ 0.033 │ 0.031 │ 0.854 │ 2.55 │ 0.048 │ 0.061 │ 0.850 │ 5.78 │ 0.112 │ 0.097
2023coreset lifelong learning model (10x compression) proposedmean pixel error distance12.93 pixelcompression=10xSelective experience replay compression using coresets for lifelong deep reinforcement learning in medical imaging
Source quote
L7: We evaluated the coreset lifelong deep reinforcement learning technique on the brain tumor segmentation (BRATS) dataset for the task of ventricle localization and on the whole-body MRI for localization of left knee cap, left kidney, right trochanter, left lung, and spleen. The coreset lifelong learning models trained on a sequence of 10 different brain MR imaging environments demonstrated excellent performance localizing the ventricle with a mean pixel error distance of 12.93, 13.46, 17.75, and 18.55 for the compression ratios of 10x, 20x, 30x, and 40x, respectively. In comparison, the conventional lifelong learning model localized the ventricle with a mean pixel distance of 10.87. Similarly, the coreset lifelong learning models trained on whole-body MRI demonstrated no significant difference (p=0.28) between the 10x compressed coreset lifelong learning models and conventional lifelong learning models for all the landmarks. The mean pixel distance for the 10x compressed models across all the landmarks was 25.30, compared to 19.24 for the conventional lifelong learning models. Our results demonstrate that the potential of the coreset-based ERB compression method for compressing experiences without a significant drop in performance.
2023coreset lifelong learning model (40x compression) proposedmean pixel error distance18.55 pixelcompression=40xSelective experience replay compression using coresets for lifelong deep reinforcement learning in medical imaging
Source quote
L7: We evaluated the coreset lifelong deep reinforcement learning technique on the brain tumor segmentation (BRATS) dataset for the task of ventricle localization and on the whole-body MRI for localization of left knee cap, left kidney, right trochanter, left lung, and spleen. The coreset lifelong learning models trained on a sequence of 10 different brain MR imaging environments demonstrated excellent performance localizing the ventricle with a mean pixel error distance of 12.93, 13.46, 17.75, and 18.55 for the compression ratios of 10x, 20x, 30x, and 40x, respectively. In comparison, the conventional lifelong learning model localized the ventricle with a mean pixel distance of 10.87. Similarly, the coreset lifelong learning models trained on whole-body MRI demonstrated no significant difference (p=0.28) between the 10x compressed coreset lifelong learning models and conventional lifelong learning models for all the landmarks. The mean pixel distance for the 10x compressed models across all the landmarks was 25.30, compared to 19.24 for the conventional lifelong learning models. Our results demonstrate that the potential of the coreset-based ERB compression method for compressing experiences without a significant drop in performance.
2023CG-CDM proposedinfer time2.78sweakly-supervised · Q=400 · R=10 · s=10 · τ=0.95 · denoising-iterations=10Conditional Diffusion Models for Weakly Supervised Medical Image Segmentation
Source quote
L186: CG-CDM │ 0.563±0.023 │ 0.450±0.012 │ 19.2±3.2 │ 2.78s
2023MMCCD proposedDICE0.6092unsupervised · input-modality=FLAIRModality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRI
Source quote
L191: MMCCD │ 0.6092 │ 0.9409 │ 0.4682 │ 0.6505 │ 0.6336 │ 6.1171
2023MMCCD proposedJac0.4682unsupervised · input-modality=FLAIRModality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRI
Source quote
L191: MMCCD │ 0.6092 │ 0.9409 │ 0.4682 │ 0.6505 │ 0.6336 │ 6.1171
2023Ensemble ResNet-34x50 `and' proposedBest AVG DSC70.3weakly-supervised · backbone=ResNet-34 + ResNet-50 ensemble · resolution=34x50 · supervision=image-level labelsExploring Weakly Supervised Semantic Segmentation Ensembles for Medical Imaging Systems
Source quote
L232: Ensemble ResNet-34x50 `and' │ 70.3 │ 54.2
2023SyMOT-Flow proposedSSIM ↑0.83split: test · encoding=VQ-VAE-2 · subgroup=T2Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal Transport
Source quote
L529: Ours │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27
2023ViT-AE++ proposedAUC0.767backbone=ViT-AE · dimension=3D · training-samples-per-fold=260ViT-AE++: Improving Vision Transformer Autoencoder for Self-supervised Medical Image Representations
Source quote
L146: ViT-AE++(ours) │ {0.767} │ 0.846
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR30.68 dBsplit: test · scale=8x out-of-scale · target-modality=T2 · reference-modality=T1Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L576: 30.68
2023LKA-E proposedHD95 (WT)2.449split: testLarge-kernel Attention for Efficient and Robust Brain Lesion Segmentation
Source quote
L147: LKA-E (Ours) │ \multicolumn{1}{l|}{0.888} │ \multicolumn{1}{l|}{0.932} │ 0.939 │ \multicolumn{1}{l|}{1.414} │ \multicolumn{1}{l|}{2.000} │ 2.449^*
2023Chebyshev confidence guided SFDA framework (full configuration) proposedDice77.10adaptation=source-free domain adaptation · evaluation=average over scenariosA Chebyshev Confidence Guided Source-Free Domain Adaptation Framework for Medical Image Segmentation
Source quote
L316: \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 89.28 │ 6.52 │ 77.10 │ 10.60
2023Chebyshev confidence guided SFDA framework (full configuration) proposedASD10.60adaptation=source-free domain adaptation · evaluation=average over scenariosA Chebyshev Confidence Guided Source-Free Domain Adaptation Framework for Medical Image Segmentation
Source quote
L316: \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 89.28 │ 6.52 │ 77.10 │ 10.60
2023GL-MAE (ViT-T; listed as Ours) proposedAvg Dice score78.31%backbone=ViT-TAdvancing Volumetric Medical Image Segmentation via Global-Local Masked Autoencoder
Source quote
L234: Ours │ ViT-T │ 83.00 │ 91.15 │ 60.46 │ 78.31
2023K-CROSS proposed non-standard sliceInconsistency with radiologist evaluations (lower is better)0.1851subset=1,200 images per generator · generator=CycleGAN · evaluation-study=NIRPSK-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality Assessment
Source quote
L374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147}
2023K-CROSS proposed non-standard sliceInconsistency with radiologist evaluations (lower is better)0.2246subset=1,200 images per generator · generator=MUNIT · evaluation-study=NIRPSK-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality Assessment
Source quote
L374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147}
2023K-CROSS proposed non-standard sliceInconsistency with radiologist evaluations (lower is better)0.2147subset=1,200 images per generator · generator=UNIT · evaluation-study=NIRPSK-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality Assessment
Source quote
L374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147}
2023ProM (2D) proposedDice0.706acceleration=x32 · mask-variant=2DConstrained Probabilistic Mask Learning for Task-specific Undersampled MRI Reconstruction
Source quote
L226: \multirow{2}{*}{\texttt{x32}} │ Dice │ \uparrow \,\, │ 0.644 │ 0.399 │ 0.592 │ 0.587 │ 0.727 │ 0.580 │ 0.315 │ 0.537 │ 0.483 │ 0.706
2023ProM (2D) proposedIoU0.608acceleration=x32 · mask-variant=2DConstrained Probabilistic Mask Learning for Task-specific Undersampled MRI Reconstruction
Source quote
L227: IoU │ \uparrow \,\, │ 0.517 │ 0.301 │ 0.466 │ 0.460 │ 0.606 │ 0.472 │ 0.226 │ 0.428 │ 0.374 │ 0.608
2023Ours ensemble (1/4 train/validation task split) proposedPixel-wise AP (average precision)76.2split: test · ensemble=yes · modality=brain MRI · task-split=1/4 train/validationMany tasks make light work: Learning to localise medical anomalies from multiple synthetic tasks
Source quote
L229: \multicolumn{3}{l}{Ours} │ 87.6/92.2 │ 62.0/84.6 │ 76.2/99.1 │ 45.9/97.9 │ 78.4/76.6 │ 71.2/81.1 │ 21.1/75.6 │ 21.4/81.2
2023E2ENet (DSFF enabled; restricted depth-shift enabled) proposedmDice74.5%split: val · 5-fold-cross-validation · DSFF=enabled · kernel-size=1×3×3 · restricted-depth-shift=enabledE2ENet: Dynamic Sparse Feature Fusion for Accurate and Efficient 3D Medical Image Segmentation
Source quote
L349: \CheckmarkBold │ \CheckmarkBold │ (1×3×3) │ 81.2 │ 62.7 │ 79.5 │ 74.5 │ 11.24 │ 1067.06
2023Cyclic UNet ablationDICE0.5810unsupervised · input-modality=FLAIRModality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRI
Source quote
L190: Cyclic UNet │ 0.5810 │ 0.9409 │ 0.4470 │ 0.6545 │ 0.5823 │ 6.3487
2023Cyclic UNet ablationJac0.4470unsupervised · input-modality=FLAIRModality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRI
Source quote
L190: Cyclic UNet │ 0.5810 │ 0.9409 │ 0.4470 │ 0.6545 │ 0.5823 │ 6.3487
2023Vanilla ViT-AE ablationAUC0.696backbone=ViT-AE · dimension=3D · training-samples-per-fold=260ViT-AE++: Improving Vision Transformer Autoencoder for Self-supervised Medical Image Representations
Source quote
L144: Vallina ViT-AE │ 0.696 │ 0.828
2023MAE3D (ViT-T)Avg Dice score77.29%backbone=ViT-TAdvancing Volumetric Medical Image Segmentation via Global-Local Masked Autoencoder
Source quote
L233: MAE3D │ ViT-T │ 82.34 │ 90.35 │ 59.18 │ 77.29
2023SVLS (σ=2) baselineECE0.146class=foreground · sigma=2 · training=2D slices · evaluation=3D volumesTrust your neighbours: Penalty-based constraints for model calibration
Source quote
L175: SVLS \cite{islam2021spatially} (\sigma=2) │ 0.857 │ 5.72 │ 0.039 │ 0.036 │ 0.824 │ 2.81 │ 0.091 │ 0.083 │ 0.801 │ 8.44 │ 0.146 │ 0.111
2023conventional lifelong learning model baselinemean pixel distance10.87 pixelReported as the conventional lifelong learning comparison to the coreset models.Selective experience replay compression using coresets for lifelong deep reinforcement learning in medical imaging
Source quote
L7: We evaluated the coreset lifelong deep reinforcement learning technique on the brain tumor segmentation (BRATS) dataset for the task of ventricle localization and on the whole-body MRI for localization of left knee cap, left kidney, right trochanter, left lung, and spleen. The coreset lifelong learning models trained on a sequence of 10 different brain MR imaging environments demonstrated excellent performance localizing the ventricle with a mean pixel error distance of 12.93, 13.46, 17.75, and 18.55 for the compression ratios of 10x, 20x, 30x, and 40x, respectively. In comparison, the conventional lifelong learning model localized the ventricle with a mean pixel distance of 10.87. Similarly, the coreset lifelong learning models trained on whole-body MRI demonstrated no significant difference (p=0.28) between the 10x compressed coreset lifelong learning models and conventional lifelong learning models for all the landmarks. The mean pixel distance for the 10x compressed models across all the landmarks was 25.30, compared to 19.24 for the conventional lifelong learning models. Our results demonstrate that the potential of the coreset-based ERB compression method for compressing experiences without a significant drop in performance.
2023DDPM baselineDICE0.5662split: test · unsupervised · input-modality=FLAIRModality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRI
Source quote
L188: \textbf{DDPM\cite{pinaya_fast_2022}} │ 0.5662 │ 0.9267 │ 0.4172 │ 0.5958 │ 0.5949 │ 6.5021
2023DDPM baselineJac0.4172split: test · unsupervised · input-modality=FLAIRModality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRI
Source quote
L188: \textbf{DDPM\cite{pinaya_fast_2022}} │ 0.5662 │ 0.9267 │ 0.4172 │ 0.5958 │ 0.5949 │ 6.5021
2023WSS-CMER baselineBest AVG DSC59.7weakly-supervised · supervision=image-level labelsExploring Weakly Supervised Semantic Segmentation Ensembles for Medical Imaging Systems
Source quote
L225: WSS-CMER │ 59.7 │ 42.6
2023UNIT baselineSSIM ↑0.77split: test · encoding=VQ-VAE-2 · subgroup=T2Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal Transport
Source quote
L527: UNIT \cite{liu2017unsupervised} │ 0.79 │ 111.93 │ 0.77 │ 82.23 │ 0.68 │ 116.32 │ 0.48 │ 105.75
2023MoCO-v3 baselineAUC0.795dimension=3D · training-samples-per-fold=260ViT-AE++: Improving Vision Transformer Autoencoder for Self-supervised Medical Image Representations
Source quote
L142: MoCO-v3 │ 0.795 │ 0.734
2023LTE* [13] (SwinIR backbone; reference and target concatenated) baselinePSNR29.97 dBscale=8x out-of-scale · backbone=SwinIR · target-modality=T2 · reference-modality=T1Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L565: 29.97
2023Swin-UNETR baselineHD95 (WT)3.606split: test · backbone=Swin-UNETRLarge-kernel Attention for Efficient and Robust Brain Lesion Segmentation
Source quote
L146: Swin-UNETR │ \multicolumn{1}{l|}{0.894} │ \multicolumn{1}{l|}{0.932} │ 0.938 │ \multicolumn{1}{l|}{1.414} │ \multicolumn{1}{l|}{2.236} │ 3.606
2023DIST baseline non-standard sliceInconsistency with radiologist evaluations (lower is better)0.1901generator=CycleGAN · evaluation-study=NIRPSK-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality Assessment
Source quote
L372: DIST~\cite{Ding2022ImageQA} │ 0.3012 │ 0.1901 │ 0.1725 │ 0.2291 │ 0.2387 │ 0.2230
2023LPIP baseline non-standard sliceInconsistency with radiologist evaluations (lower is better)0.2285generator=MUNIT · evaluation-study=NIRPSK-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality Assessment
Source quote
L371: LPIP~\cite{Zhang2018TheUE} │ 0.3023 │ 0.1921 │ 0.1786 │ 0.2285 │ 0.2398 │ 0.2327
2023DIST baseline non-standard sliceInconsistency with radiologist evaluations (lower is better)0.2230generator=UNIT · evaluation-study=NIRPSK-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality Assessment
Source quote
L372: DIST~\cite{Ding2022ImageQA} │ 0.3012 │ 0.1901 │ 0.1725 │ 0.2291 │ 0.2387 │ 0.2230
2023Complementary baselineaverage MSE (brain mask)0.04split: test · region=brain mask · normalization=[0,1]MRI Scan Synthesis Methods Based on Clustering and Pix2Pix
Source quote
L206: The second baseline, Complementary\xspace evaluates to reasonable MSEs, e.g., it has 0.04 on average in the brain mask and 0.03 in the tumor area on \texttt{testBraTS\xspace}\xspace. All our methods improve upon these values as can be seen in \cref{fig:test_mse}. The scans generated by Pix2Pix\xspace have a better MSE than BrainClustering\xspace in the brain mask area. In the tumor area, the average MSE of both methods is comparable, and it is overall better, although the median MSE is still below 0.02. The best results are produced by Pix2Pix\xspace ResNet\ with \lambda=500 and \gamma =500, but Pix2Pix\xspace UNet\ with \lambda=100 and \gamma=0 also produces good results. Notably, BrainClustering\xspace with Search\xspace with 10 patients and 5 clusters achieves the best median MSE in the tumor area among all methods we tested. We conclude that it is possible to compute synthesized scans that closely resemble the true scan.
2022DDPM (f=4) (b) [Ours] proposedtheoretically best possible DICE-score (\lceil DICE \rceil)0.469unsupervised · model-variant=DDPM (f=4) (b)Fast Unsupervised Brain Anomaly Detection and Segmentation with Diffusion Models
Source quote
L91: DDPM (f=4) (b) [Ours] │ 0.208^\dagger │ 0.204 │ 0.469^\dagger │ 0.272
2022UNETR+MAE proposedaverage DSC78.91%self-pretraining · backbone=UNETR · mask-ratio=12.5%Self Pre-Training with Masked Autoencoders for Medical Image Classification and Segmentation
Source quote
L124: UNETR+MAE │ 78.91 │ 7.22 │ 90.84 │ 7.04 │ 63.88 │ 7.15 │ 82.00 │ 7.13
2022PseudoClick (C+L, HRNet32) proposedmIoU@364.0%Cross-domain human evaluation; trained on C+L and applied without finetuning; 3 human c…PseudoClick: Interactive Image Segmentation with Click Imitation
Source quote
L230: Ours │ C+L │ N/A │ HRNet32 │ 64.0 │ 80.1