BraTS
93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ReMIC SOTA frontier | 0.9618 | 2021-01-01 | target=T1 · Image-completion result from the extended results table; quantitative test generation… | Multi-Domain Image Completion for Random Missing Input DataSource quote{ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2 | TransCSCN | 0.943 | 2022-01-01 | modality-direction=T1w-to-FLAIR · Table 1 average; 45 BraTS test cases; bias-field-corrected scans; unsupervised method… | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quote0.943 |
| 3 | MRNet | 0.9411 | 2024-12-01 | plane=axial · direction=FLAIR-to-T2 · Paired FLAIR-to-T2 evaluation on axial cross-sections; test set comprises 127 persons… | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteOURS │ 31.2852 │ 0.9411 │ \checkmark |
| 4 | SynNet (Joint Loss) SOTA frontier (+3 variants) | 0.86 | 2018-06-01 | loss=joint · input-modality=T1 · target-modality=T2 · T1 input and T2 output; BRATS dataset description reports 96 training and 24 testing … | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteJoint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 5 | SyMOT-Flow | 0.83 | 2023-08-01 | encoding=VQ-VAE-2 · subgroup=T2 · BraTS MRI slices; 1,000 training and 251 test images per modality; VQ-VAE-2 feature-s… | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteOurs │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
Metricdice (30)psnr (27)ssim (19)dsc (11)inconsistency with radiologist evaluations lower (6)iou (5)
Regimefine-tuned (9)unsupervised (8)unsupervised-domain-adaptation (6)semi-supervised (5)weakly-supervised (4)few-shot (4)
Showing 150 of 227 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | JiT-L/16 (direct IN transfer) proposed | gFID | 40.17 | split: test · in-initialized-training | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL884: 40.17 |
| 2026 | JiT-B/16 (IN initialization) proposed | gFID | 31.73 | split: test · fine-tuned | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL865: 31.73 |
| 2026 | MPFlow (full) proposed non-standard slice | Dice (\uparrow) | 0.740 | 0-shot · backbone=Swin-UNet · input-modality=FLAIR · sampling-steps=100 · evaluation-model=Swin-UNet | MPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI ReconstructionSource quoteL290: MPFlow (full) │ \textbf{4.85× 10 (-4)} │ 0.740 |
| 2026 | VariaFlow proposed | AUROC | 0.78 | split: test · cross-domain | VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly DetectionSource quoteL34: the highest AUROC (0.94, 0.80, 0.78) on each and the high- |
| 2026 | SynerMedGen (Stage I+II) proposed | SSIM | 90.62 | modality=FL.→T1 | SynerMedGen: Synergizing Medical Multimodal Understanding with Generation via Task AlignmentSource quoteL733: 90.62+9.28 |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposed | Mean PSNR | 27.3 dB | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposed | Mean SSIM | 0.95 | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | MRIComp4Flow WFM trained on JPEG2000-compressed data at 200:1 proposed | PSNR | 24.65 dB | split: val · modality=T1n · compression=JPEG2000 200:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL125: 200 │ 23.25 │ 24.65 │ 23.07 │ 22.63 │ 0.879 │ 0.968 │ 0.937 │ 0.902 |
| 2026 | MRIComp4Flow WFM trained on JPEG2000-compressed data at 400:1 proposed | PSNR | 20.94 dB | split: val · modality=T1n · compression=JPEG2000 400:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL126: 400 │ 19.30 │ 20.94 │ 21.29 │ 17.18 │ 0.852 │ 0.829 │ 0.814 │ 0.750 |
| 2026 | Transfer-Aware proposed | Dice | 55.1% | fine-tuned · modality=Brain T1 | Knowledge Transfer Scaling Laws for 3D Medical ImagingSource quoteL468: The same trend holds for dense prediction. On AMOS, Transfer-Aware achieves 83.1 Dice on abdominal CT and 69.4 Dice on abdominal MRI, outperforming Data-Proportional by 1.5 and 0.6 points, respectively. The gains are larger on brain and head-and-neck tasks. On BraTS, Transfer-Aware improves over Data-Proportional from 50.4 to 55.1 Dice on Brain T1 and from 61.4 to 65.4 Dice on Brain T2. On head-and-neck CT segmentation, Transfer-Aware improves HECKTOR from 67.8 to 71.1 Dice and BHSD from 57.2 to 61.2 Dice. Across all six segmentation tasks, Transfer-Aware yields the best performance among the compared pretraining strategies. |
| 2026 | SynerMedGen-UCG (Stage II) ablation | SSIM | 81.34 | variant=Stage II only · modality=FL.→T1 | SynerMedGen: Synergizing Medical Multimodal Understanding with Generation via Task AlignmentSource quoteL719: 81.34 |
| 2026 | GALoss[11] (ECCV 2024) | Dice | 83.49% | split: test | Scale-aware adaptive supervised network with limited medical annotationsSource quoteL1314: 83.49 |
| 2026 | SASNet | Dice | 85.84% | split: test | Scale-aware adaptive supervised network with limited medical annotationsSource quoteL1321: 85.84 |
| 2026 | JiT-B/16 (random initialization; RADIN-pretrained) baseline | gFID | 36.73 | split: test · medical-pretrained-then-fine-tuned | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL853: 36.73 |
| 2026 | JiT-L/16 (single-channel BRATS-pretrained) baseline | gFID | 50.90 | split: test · medical-pretrained | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL880: 50.90 |
| 2026 | JiT-L/16 (RADIN-pretrained) baseline | gFID | 75.40 | split: test · medical-pretrained | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL876: 75.40 |
| 2026 | DynamicDPS baseline non-standard slice | Dice (\uparrow) | 0.639 | 0-shot · backbone=Swin-UNet · input-modality=FLAIR · sampling-steps=100 · evaluation-model=Swin-UNet | MPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI ReconstructionSource quoteL288: DynamicDPS │ 4.51× 10 (-2) │ 0.639 |
| 2026 | REFLECT baseline | AUROC | 0.6828 | split: test · cross-domain | VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly DetectionSource quoteL680: 0.6828 AUROC on BraTS. IterMask2 shows a similar trend, |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baseline | Mean PSNR | 27.0 dB | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressed | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baseline | Mean SSIM | 0.96 | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressed | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | Data-Proportional baseline | Dice | 50.4% | fine-tuned · modality=Brain T1 | Knowledge Transfer Scaling Laws for 3D Medical ImagingSource quoteL468: The same trend holds for dense prediction. On AMOS, Transfer-Aware achieves 83.1 Dice on abdominal CT and 69.4 Dice on abdominal MRI, outperforming Data-Proportional by 1.5 and 0.6 points, respectively. The gains are larger on brain and head-and-neck tasks. On BraTS, Transfer-Aware improves over Data-Proportional from 50.4 to 55.1 Dice on Brain T1 and from 61.4 to 65.4 Dice on Brain T2. On head-and-neck CT segmentation, Transfer-Aware improves HECKTOR from 67.8 to 71.1 Dice and BHSD from 57.2 to 61.2 Dice. Across all six segmentation tasks, Transfer-Aware yields the best performance among the compared pretraining strategies. |
| 2025 | MAD-AD proposed | Modality (Max Dice) | 70.3 | setting=S2 · modalities=FLAIR, T1CE, T2-w, T1-w · aggregation=average | MAD-AD: Masked Diffusion for Unsupervised Brain Anomaly DetectionSource quoteL178: MAD-AD (Ours) │ 76.2\worse{-4.0} │ 68.5\imp{+6.8} │ 73.2\imp{+2.0} │ 63.4\imp{+4.9} │ 70.3\imp{+2.4} |
| 2025 | fastWDM3D (T=2) proposed | AST (average sampling time per volume) | 1.81 s | split: test · sampling-steps=2 | fastWDM3D: Fast and Accurate 3D Healthy Tissue InpaintingSource quoteL134: Ours (fastWDM3D (T=2)) │ 0.86 ± 0.12 │ 0.0079 ± 0.0063 │ 22.26 ± 3.97 │ \hphantom{0}\SI{1.81}{\second} |
| 2025 | UniFS proposed | PSNR improvement over FSMNet | 1.06dB | acceleration=4× · undersampling-patterns=3 | UniFS: Unified Multi-Contrast MRI Reconstruction via Frequency-Spatial FusionSource quoteL176: As shown in Table \ref{tab1}, UniFS consistently outperforms all competing methods in terms of image reconstruction quality. Compared with the current leading method FSMNet \cite{FSMNet}, which also incorporates frequency feature fusion, UniFS achieves significant PSNR improvements of 1.06dB and 2.00dB under 4× acceleration on the BraTs and HCP datasets. These results highlight the effectiveness of the enhanced frequency fusion design within the CMF module. Furthermore, Fig. \ref{fig2} shows reconstructed images and corresponding error maps from different methods. The zoomed-in views reveal that UniFS achieves more accurate texture recovery, while the noticeably smaller error maps further confirm its superior reconstruction fidelity. |
| 2025 | IterMask3D proposed | DSC | 69.7 | split: test · test-time-refinement · tuning=test-set, 3 standard deviations · modality=FLAIR · training-data=cognitively normal ADNI/OASIS · dimensionality=3D | IterMask3D: Unsupervised Anomaly Detection and Segmentation with Test-Time Iterative Mask Refinement in 3D Brain MRSource quoteL534: \multicolumn{1}{l|}{IterMask3D} │ 69.7 │ 99.2 │ 72.7 │ 71.1 │ 56.7 │ 32.2 │ 5.1 |
| 2025 | OAIMS proposed | Dice | 74.6 | clicks=10 · modality=T1 · incorrect-clicks=40% | You Point, I Learn: Online Adaptation of Interactive Segmentation Models for Handling Distribution Shifts in Medical ImagingSource quoteL668: OAIMS │ 67.8 │ 71.8 │ 74.6 |
| 2025 | MTMed3D (Avg.) proposed | [email protected]:0.5 | 0.9082 | aggregation=average | MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical ImagingSource quoteL232: 0.9082 │ 0.9357 │ 0.8955 |
| 2025 | MTMed3D (Avg.) proposed | [email protected]:0.5 | 0.9357 | aggregation=average | MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical ImagingSource quoteL232: 0.9082 │ 0.9357 │ 0.8955 |
| 2025 | AugPaint proposed | Dice | 35.19% | semi-supervised · analysis=mask-flipping · labeled-cases=1 | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quoteL333: AugPaint │ 35.19 │ 62.33 │ 41.85 │ 38.43 |
| 2025 | SIPL proposed | DSC | 83.0% | split: test · regions=whole tumor, enhancing tumor, tumor core · train-val-test-split=80:5:15 | Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype LearningSource quoteL197: SIPL (ours) │ 83.0 │ -- |
| 2025 | Ours-PL proposed | Dice (%) average | 59.37% | unsupervised-domain-adaptation · source_domain=T2 · target_domain=Flair | Bézier Meets Diffusion: Robust Generation Across Domains for Medical Image SegmentationSource quoteL430: Ours-PL │ 71.70 │ \bf 65.42 │ \bf 41.00 │ \bf 59.37 │ 22.59 │ 19.98 │ 25.89 │ 22.82 |
| 2025 | Ours-AD proposed | 95HD average | 18.81 | unsupervised-domain-adaptation · source_domain=T2 · target_domain=Flair | Bézier Meets Diffusion: Robust Generation Across Domains for Medical Image SegmentationSource quoteL428: Ours-AD │ 73.74 │ 62.30 │ 39.80 │ 58.61 │ 12.44 │ \bf 18.58 │ \bf 25.42 │ \bf 18.81 |
| 2025 | VIViT+SSL proposed | Mean Dice | 0.883 | split: test · resolution=128×128×128 | VIViT: Variable-Input Vision Transformer Framework for 3D MR Image SegmentationSource quoteL130: VIViT+SSL │ 0.624 │ 0.871 │ 0.893 │ 0.884 │ 0.883 |
| 2025 | Expert-guided explainable few-shot learning (guided model) proposed | Accuracy | 83.61% | few-shot · epoch=7 · episodes=60 · explanation-weight-alpha=0.10 | Expert-Guided Explainable Few-Shot Learning for Medical Image DiagnosisSource quoteL107: 7 │ 60 │ 83.61 │ 77.09 |
| 2025 | BOGC-MML proposed | Top-1 accuracy | 77.86% | available-modality=T1c · missing-modalities=Fl, T1, T2 | Multi-Modal Learning with Bayesian-Oriented Gradient CalibrationSource quoteL343: 62.02 │ 67.07 │ 72.60 │ 75.65 │ 77.86 |
| 2025 | NAGL proposed | average AUROC | 89.5% | few-shot · reference_samples=N^2+A^1 | Normal-Abnormal Guided Generalist Anomaly DetectionSource quoteL228: \paragraph{Generalization.} Our method exhibits superior generalization capabilities compared to ResAD across multiple datasets. On MVTecAD, under the N^1+A^1 setting, our approach achieves 95.7% image F1-max and 58.9% pixel F1-max, outperforming ResAD by 4.5 and 10.7 percentage points, respectively. Similarly, on VisA, we attain 85.4% image F1-max and 41.8% pixel F1-max, exceeding ResAD by 4.1 and 4.0 percentage points. Furthermore, as shown in Tab.~\ref{tab:exp_medical}, our method demonstrates superior cross-domain generalization, achieving 89.5% average AUROC on the BraTS medical dataset with just two normal and one abnormal sample, a 10.6 percentage point improvement over ResAD (78.9% with N^2 setting). Notably, across all other experimental settings, our method consistently outperforms existing approaches in both anomaly detection and segmentation. These results clearly demonstrate the effectiveness of our method in generalist AD. |
| 2025 | CADD proposed non-standard slice | Average maximum Dice | 0.3548 | fine-tuned · modality=FLAIR · fine-tuning-data=AIBL · clinical-covariates=none | CADD: Context aware disease deviations via restoration of brain images using normative conditional diffusion modelsSource quoteL343: Dice (\uparrow) │ 0.3386 │ 0.2619 │ 0.3548 |
| 2025 | Causal-SAM-LLM proposed | Dice | 75.7% | fine-tuned · evaluation=single-source-domain-generalization · aggregation=three random seeds · training_dataset=BTCV CT | Causal-SAM-LLM: Large Language Models as Causal Reasoners for Robust Medical SegmentationSource quoteL173: Causal-SAM-LLM │ 52.8 │ 83.5 │ 23.4 │ \bfseries 79.5 │ \bfseries 18.9 │ \bfseries 75.7 │ \bfseries 17.6 |
| 2025 | Causal-SAM-LLM proposed | HD95 | 17.6 mm | fine-tuned · evaluation=single-source-domain-generalization · aggregation=three random seeds · training_dataset=BTCV CT | Causal-SAM-LLM: Large Language Models as Causal Reasoners for Robust Medical SegmentationSource quoteL173: Causal-SAM-LLM │ 52.8 │ 83.5 │ 23.4 │ \bfseries 79.5 │ \bfseries 18.9 │ \bfseries 75.7 │ \bfseries 17.6 |
| 2025 | FgC2F-UDiff (Our method) proposed | PSNR | 26.34 dB | synthesis=many-to-one · target-modality=T1ce · input-modalities=T1,T2 | FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI SynthesisSource quoteL312: \multirow{2}{*}{Our method} │ 26.34 │ 0.894 │ 17.45 │ 20.85 │ 27.19 │ 0.937 │ 16.14 │ 18.74 |
| 2025 | SpectMamba proposed | mAP | 75.34 | split: test · epochs=200 · pretraining=none | SpectMamba: Integrating Frequency and State Space Models for Enhanced Medical Image DetectionSource quoteL275: {SpectMamba} │ 89.83 │ 78.64 │ 57.54 │ 75.34 │ 95.35 │ 85.64 │ 68.24 │ 83.08 |
| 2025 | Single-task (Avg.) ablation | [email protected]:0.5 | 0.8217 | aggregation=average | MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical ImagingSource quoteL237: 0.8217 │ 0.8608 │ 0.8474 |
| 2025 | Single-task (Avg.) ablation | [email protected]:0.5 | 0.8608 | aggregation=average | MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical ImagingSource quoteL237: 0.8217 │ 0.8608 │ 0.8474 |
| 2025 | AugPaint with flipped mask ablation | Dice | 36.27% | semi-supervised · labeled-cases=1 · mask-condition=randomly flipped vertically and horizontally | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quoteL334: + flipping │ 36.27(+1.08) │ 48.38(-13.95) │ 43.11(+1.26) │ 35.22(-3.21) |
| 2025 | Boundary Blur (σ=3) perturbation ablation | Evanyseg score | 0.845 | sigma=3 · perturbation=boundary blur · segmentation-model=Evanyseg | Metrics that matter: Evaluating image quality metrics for medical image generationSource quoteL315: \quad \sigma=3 │ 0.845 |
| 2025 | Ours-Bézier ablation | Dice (%) average | 58.16% | unsupervised-domain-adaptation · target_domain=T1C | Bézier Meets Diffusion: Robust Generation Across Domains for Medical Image SegmentationSource quoteL330: \bf Ours-Bézier │ \bf 62.47 │ \bf 67.89 │ \bf 44.12 │ \bf 58.16 │ \bf 20.89 │ \bf 23.07 │ \bf 27.84 │ \bf 23.93 |
| 2025 | Non-guided model ablation | Accuracy | 77.09% | few-shot · epoch=7 · episodes=60 · explanation-weight-alpha=0.10 | Expert-Guided Explainable Few-Shot Learning for Medical Image DiagnosisSource quoteL107: 7 │ 60 │ 83.61 │ 77.09 |
| 2025 | IterMask^2 baseline | Modality (Max Dice) | 67.9 | setting=S2 · modalities=FLAIR, T1CE, T2-w, T1-w · aggregation=average | MAD-AD: Masked Diffusion for Unsupervised Brain Anomaly DetectionSource quoteL176: IterMask^2~\cite{liang2024itermask2}_{\textsl {MICCAI'24}} │ 80.2 │ 61.7 │ 71.2 │ 58.5 │ 67.9 |
| 2025 | WDM3D baseline | AST (average sampling time per volume) | 5 minute | split: test · loss=MSE on wavelet coefficients · sampling-steps=1000 · variance-schedule=linear | fastWDM3D: Fast and Accurate 3D Healthy Tissue InpaintingSource quoteL133: WDM3D \cite{durrer2024denoising} │ 0.61 ± 0.16 │ 0.1060 ± 0.0757 │ 10.57 ± 3.20 │ \hphantom{0}\SI{5}{\minute} |
| 2025 | DAE (tuned) baseline | DSC | 66.7 | split: test · test-time-tuned · tuning=test-set, 3 standard deviations · modality=FLAIR · dimensionality=3D | IterMask3D: Unsupervised Anomaly Detection and Segmentation with Test-Time Iterative Mask Refinement in 3D Brain MRSource quoteL533: \multicolumn{1}{l|}{DAE (tuned)} │ 66.7 │ 99.1 │ 71.1 │ 68.7 │ 52.5 │ 34.5 │ 6.2 |
| 2025 | FullGrad (DeiT-S) baseline | DSC | 33.2% | weakly-supervised · target=whole-tumor · backbone=DeiT-S · modality=T2 FLAIR | Hybrid Transformer-Mamba Architecture for Weakly Supervised Volumetric Medical SegmentationSource quoteL191: FullGrad \cite{srinivas2019full} │ DeiT-S │ 4.0 │ 33.2 (7) │ 5.1 (7) │ 19.8 (8) │ 20.5 (3) │ 16.3 (3) │ 25.1 (2) │ 37.7 (2) │ 4.3 (2) │ 23.1 (2) |
| 2025 | ICNN* baseline | Dice | 43.9 | clicks=10 · modality=T1 · incorrect-clicks=40% | You Point, I Learn: Online Adaptation of Interactive Segmentation Models for Handling Distribution Shifts in Medical ImagingSource quoteL667: \multirow{2}{*}{\shortstack[l]{40% clicks\\are wrong}} │ ICNN (*) │ 20.6 │ 32.9 │ 43.9 |
| 2025 | UNETR++ baseline | DSC | 82.8% | split: test · regions=whole tumor, enhancing tumor, tumor core · train-val-test-split=80:5:15 | Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype LearningSource quoteL196: UNETR++ │ 82.8 │ 0.0297 |
| 2025 | GAN baseline | Evanyseg Dice score | 0.56 | segmentation-model=Evanyseg | Metrics that matter: Evaluating image quality metrics for medical image generationSource quoteL399: GAN │ 0.67 │ 0.56 |
| 2025 | DDPM baseline | Evanyseg Dice score | 0.78 | segmentation-model=Evanyseg | Metrics that matter: Evaluating image quality metrics for medical image generationSource quoteL400: DDPM │ 0.91 │ 0.78 |
| 2025 | ADVENT baseline | Dice (%) average | 57.88% | unsupervised-domain-adaptation · source_domain=T2 · target_domain=Flair | Bézier Meets Diffusion: Robust Generation Across Domains for Medical Image SegmentationSource quoteL421: ADVENT │ 75.95 │ 60.16 │ 37.52 │ 57.88 │ 14.38 │ 22.11 │ 26.44 │ 20.98 |
| 2025 | ADVENT baseline | 95HD average | 20.98 | unsupervised-domain-adaptation · source_domain=T2 · target_domain=Flair | Bézier Meets Diffusion: Robust Generation Across Domains for Medical Image SegmentationSource quoteL421: ADVENT │ 75.95 │ 60.16 │ 37.52 │ 57.88 │ 14.38 │ 22.11 │ 26.44 │ 20.98 |
| 2025 | CyCADA baseline | Dice (%) average | 48.76% | unsupervised-domain-adaptation · target_domain=T1C | Bézier Meets Diffusion: Robust Generation Across Domains for Medical Image SegmentationSource quoteL327: CyCADA │ 57.25 │ 58.15 │ 30.89 │ 48.76 │ 29.15 │ 33.90 │ 38.92 │ 33.99 |
| 2025 | SwinUNETR baseline | Mean Dice | 0.874 | split: test | VIViT: Variable-Input Vision Transformer Framework for 3D MR Image SegmentationSource quoteL126: SwinUNETR │ 0.611 │ 0.873 │ 0.883 │ 0.867 │ 0.874 |
| 2025 | ResAD baseline | average AUROC | 78.9% | few-shot · reference_samples=N^2 | Normal-Abnormal Guided Generalist Anomaly DetectionSource quoteL228: \paragraph{Generalization.} Our method exhibits superior generalization capabilities compared to ResAD across multiple datasets. On MVTecAD, under the N^1+A^1 setting, our approach achieves 95.7% image F1-max and 58.9% pixel F1-max, outperforming ResAD by 4.5 and 10.7 percentage points, respectively. Similarly, on VisA, we attain 85.4% image F1-max and 41.8% pixel F1-max, exceeding ResAD by 4.1 and 4.0 percentage points. Furthermore, as shown in Tab.~\ref{tab:exp_medical}, our method demonstrates superior cross-domain generalization, achieving 89.5% average AUROC on the BraTS medical dataset with just two normal and one abnormal sample, a 10.6 percentage point improvement over ResAD (78.9% with N^2 setting). Notably, across all other experimental settings, our method consistently outperforms existing approaches in both anomaly detection and segmentation. These results clearly demonstrate the effectiveness of our method in generalist AD. |
| 2025 | AutoDDPM (3D) baseline non-standard slice | Average maximum Dice | 0.3386 | fine-tuned · model=AutoDDPM (3D) · modality=FLAIR · fine-tuning-data=AIBL · clinical-covariates=none | CADD: Context aware disease deviations via restoration of brain images using normative conditional diffusion modelsSource quoteL343: Dice (\uparrow) │ 0.3386 │ 0.2619 │ 0.3548 |
| 2025 | MoME baseline | DICE | 92.10 | dataset-version=2021 | Brain Imaging Foundation Models, Are We There Yet? A Systematic Review of Foundation Models for Brain Imaging and Biomedical ResearchSource quoteL445: MoME │ 2021 │ 92.10 |
| 2025 | BrainSegFounder baseline | DICE | 91.15 | dataset-version=2023 | Brain Imaging Foundation Models, Are We There Yet? A Systematic Review of Foundation Models for Brain Imaging and Biomedical ResearchSource quoteL448: BrainSegFounder │ 2023 │ 91.15 |
| 2025 | ShapePU baseline | Dice | 0.057 | scribble-supervised · annotation=scribbles | Revisiting 3D Medical Scribble Supervision: Benchmarking Beyond Cardiac SegmentationSource quoteL113: 0.057 |
| 2025 | Uni-GAN baseline | PSNR | 25.57 dB | synthesis=many-to-one · target-modality=T1ce · input-modalities=T1,T2 | FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI SynthesisSource quoteL308: \multirow{2}{*}{Uni-GAN} │ 25.57 │ 0.886 │ 18.13 │ 21.77 │ 26.54 │ 0.930 │ 16.97 │ 20.07 |
| 2024 | QCResUNet proposed | Pearson r (DSC prediction) | 0.968 | split: test · metric-target=DSC · prediction-level=subject-level · segmentation-models=nnUNet, nnFormer | QCResUNet: Joint subject-level and voxel-level segmentation quality predictionSource quoteL279: Specifically, on the BraTS internal testing set with segmentations generated by nnUNet and nnFormer, the proposed method achieved a small mean MAE of 0.056 and 0.064 for NSD and DSC prediction, respectively. The predicted NSD and DSC also showed a strong correlation with the corresponding ground truth, achieving Pearson r values of 0.958 and 0.968, respectively. Importantly, the proposed method generalized well for segmentation produced by different methods (i.e., DeepMedic), which had not been used during training, achieving an average MAE of 0.074 and 0.062 for NSD and DSC prediction. Similarly, the predicted NSD and DSC showed a strong correlation with their ground truth with Pearson r values of 0.937 and 0.962, respectively. |
| 2024 | Domain-Game proposed | Dice | 65.05 | targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1Gd | Domain GameSource quoteL263: \ \ \textBF{65.05 \down{13.42}} \ \ │ \ \textBF{59.53 \down{15.95}} |
| 2024 | Domain-Game proposed | Jaccard | 59.53 | targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1Gd | Domain GameSource quoteL263: \ \ \textBF{65.05 \down{13.42}} \ \ │ \ \textBF{59.53 \down{15.95}} |
| 2024 | McCaD proposed | Dice score | 0.8004 | split: test · retained-contrasts=T1w, FLAIR · synthetic-contrast=T2w · segmentation-target=whole-tumor | McCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI SynthesisSource quoteL210: AttGAN │ DDPM │ Hi-Net │ MM-GAN │ McCaD │ Complete T2w │ 0.7692 │ 0.7987 │ 0.7921 │ 0.7991 │ 0.8004 │ 0.8188 T2w + FLAIR │ 0.6974 │ 0.6262 │ 0.7401 │ 0.7449 │ 0.7602 │ 0.8188 |
| 2024 | HF-GAN proposed | PSNR | 30.27 | aggregation=average across missing-sequence scenarios · architecture=2D slice-based | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | HF-GAN proposed | SSIM | 0.9393 | aggregation=average across missing-sequence scenarios · architecture=2D slice-based | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | HF-GAN (ours) imputation proposed | Dice (ET) | 0.6438 | split: test · evaluation=after imputation · architecture=2D slice-based · test-subjects=85 · segmentation-region=ET | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL284: \multicolumn{4}{c|}{Average} │ 0.6196* (0.3202) │ 0.5130* (0.3041) │ 0.4957* (0.3598) │ 0.8436* (0.1279) │ 0.7247* (0.1728) │ 0.6139* (0.3619) │ 0.8405* (0.1356) │ 0.7178* (0.1766) │ 0.6313* (0.3446) │ 0.8632 (0.1033) │ 0.7488 (0.1588) │ 0.6174* (0.3743) │ 0.8618 (0.1071) │ 0.7472 (0.1625) │ 0.6438 (0.3397) |
| 2024 | MRNet proposed | PSNR | 31.2852 | split: test · plane=axial · direction=FLAIR-to-T2 | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteL269: OURS │ 31.2852 │ 0.9411 │ \checkmark |
| 2024 | MRNet proposed | SSIM | 0.9411 | split: test · plane=axial · direction=FLAIR-to-T2 | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteL269: OURS │ 31.2852 │ 0.9411 │ \checkmark |
| 2024 | Ours (GAN-based semantic segmentation model) proposed | Pixel Accuracy | 0.5821 | Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state… | Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic SegmentationSource quoteL140: Pixel Accuracy and Recall of these models, the performance of each model in the brain tumor segmentation task can be more comprehensively evaluated. First of all, from the perspective of pixel accuracy (Pixel Accuracy), our model performs best, reaching 0.5821, which is significantly improved compared to other models. Specifically, the pixel accuracy of FCNs is |
| 2024 | Ours (GAN-based semantic segmentation model) proposed | Recall | 0.5523 | Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state… | Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic SegmentationSource quoteL143: Secondly, from the perspective of recall index, our model also performed well, reaching 0.5523, which is better than all other comparison models. The recall rate of FCNs is 0.5231, |
| 2024 | Ours (GAN-based semantic segmentation model) proposed | Dice | 0.4433 | Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state… | Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic SegmentationSource quoteL175: From the perspective of Dice coefficient, our model also performs well, reaching 0.4433, which is higher than all other models. The Dice coefficient of FCNs is 0.4119, SegNet is |
| 2024 | TrIND (per-sample INR) proposed non-standard slice | Rel. Error | 0.039% | Table 2: relative percentage error between reconstructed signal and ground truth; repre… | TrIND: Representing Anatomical Trees by Denoising Diffusion of Implicit Neural FieldsSource quoteL225: 0.039 |
| 2024 | TrIND (per-sample INR) proposed | INR Size | 0.753 MB | Table 2 reports the INR size for this modality alongside input size; the table evaluate… | TrIND: Representing Anatomical Trees by Denoising Diffusion of Implicit Neural FieldsSource quoteL227: 0.753↓×90.45 |
| 2024 | VerSe (Mode-3) proposed | Dice(10) | 94.492 | evaluation=out-of-distribution · interaction=10-click | VerSe: Integrating Multiple Queries as Prompts for Versatile Cardiac MRI SegmentationSource quoteL270: \texttt{VerSe} (Mode-3) │ 69.516 │ 80.631 │ 11.787 │ 94.492 │ 96.811 │ 2.777 |
| 2024 | VerSe (Mode-3) proposed | Dice(20) | 96.811 | evaluation=out-of-distribution · interaction=20-click | VerSe: Integrating Multiple Queries as Prompts for Versatile Cardiac MRI SegmentationSource quoteL270: \texttt{VerSe} (Mode-3) │ 69.516 │ 80.631 │ 11.787 │ 94.492 │ 96.811 │ 2.777 |
| 2024 | HiDiff proposed non-standard slice | Average Dice | 51.77 | split: test · subset=small tumors; pixel-wise tumor size <100 | HiDiff: Hybrid Diffusion Framework for Medical Image SegmentationSource quoteL506: {{HiDiff}\xspace (ours)} │ 51.77 │ 8.76(20.13%) │ 59.00 │ 47.30 │ 49.00 |
| 2024 | PrimGeoSeg (SwinUNETR; FDSL pre-training) proposed | Avg. score | 90.3 | fine-tuned · backbone=SwinUNETR · pretraining=FDSL | Primitive Geometry Segment Pre-training for 3D Medical Image SegmentationSource quoteL305: PrimGeoSeg │ FDSL │ 88.7 │ 85.6 │ 91.8 │ 88.9 │ 90.3 │ 87.0 │ 92.9 │ 91.0 \\[0.8pt] |
| 2024 | MultiUNet (drop mods) proposed | Dice | 0.614 | input=single-modality · evaluation=held-out-unseen-pathology · modalities=Flair-or-T1 | Feasibility and benefits of joint learning from MRI databases with different brain diseases and modalities for segmentationSource quoteL165: MultiUNet (drop mods) │ Flair or T1 │ 0.614 │ 0.454 │ 0.324 │ 0.241 │ 0.540 |
| 2024 | NACL proposed | DSC | 0.850 | backbone=UNet · training=2D slices · evaluation=3D volumes | Neighbor-aware calibration of segmentation networks with penalty-based constraintsSource quoteL238: Mean │ 0.789 │ 6.96 │ \und{0.848} │ 9.00 │ 0.808 │ 8.71 │ 0.820 │ 7.78 │ 0.801 │ 8.44 │ 0.838 │ 7.94 │ 0.850 │ 5.78 |
| 2024 | TrIND (INR representation) proposed non-standard slice | Rel. Error | 0.039% | INR reconstruction; relative percentage error between the reconstructed signal and grou… | Representing Anatomical Trees by Denoising Diffusion of Implicit Neural FieldsSource quoteL201: BraTS~\cite{menze2014multimodal} │ 0.039 │ 68.11-± 0.00 │ 0.753-\downarrow ×90.45 |
| 2024 | Kaggle duplicate audit proposed | Duplicates | 383 duplicates | platform=Kaggle · data-collected=October 2024 | Copycats: the many lives of a publicly available medical imaging datasetSource quoteL188: BraTS~\cite{menze2014multimodal} │ 383 │ \phantom{0}51.5 GB\textsuperscript{\mathsection} │ \phantom{00}7.3 TB │ 30.0 │ 9 │ 92.4 |
| 2024 | X-Diffusion (1-slice input) proposed | Test 3D PSNR | 23.10 | split: test · sequence=FLAIR T2 · input-slices=1 | X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion ModelsSource quoteL131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01 |
| 2024 | IBN-Net baseline | Dice | 58.39 | targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1Gd | Domain GameSource quoteL239: 58.39 \down{19.55} │ 46.89 \down{27.03} |
| 2024 | BayeSeg baseline | Jaccard | 54.24 | targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1Gd | Domain GameSource quoteL257: 57.39 \down{20.89} │ 54.24 \down{20.59} |
| 2024 | Complete baseline non-standard slice | Dice score | 0.8188 | split: test · contrast-input=all three ground-truth contrasts · segmentation-target=whole-tumor | McCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI SynthesisSource quoteL210: AttGAN │ DDPM │ Hi-Net │ MM-GAN │ McCaD │ Complete T2w │ 0.7692 │ 0.7987 │ 0.7921 │ 0.7991 │ 0.8004 │ 0.8188 T2w + FLAIR │ 0.6974 │ 0.6262 │ 0.7401 │ 0.7449 │ 0.7602 │ 0.8188 |
| 2024 | Hyper-GAE (3D) baseline | PSNR | 29.54 | evaluation=2D slices · aggregation=average across missing-sequence scenarios · architecture=3D | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | Hyper-GAE (3D) baseline | SSIM | 0.9361 | evaluation=2D slices · aggregation=average across missing-sequence scenarios · architecture=3D | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | Hyper-GAE imputation baseline | Dice (ET) | 0.6174 | split: test · evaluation=after imputation · architecture=3D volumetric · test-subjects=85 · segmentation-region=ET | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL284: \multicolumn{4}{c|}{Average} │ 0.6196* (0.3202) │ 0.5130* (0.3041) │ 0.4957* (0.3598) │ 0.8436* (0.1279) │ 0.7247* (0.1728) │ 0.6139* (0.3619) │ 0.8405* (0.1356) │ 0.7178* (0.1766) │ 0.6313* (0.3446) │ 0.8632 (0.1033) │ 0.7488 (0.1588) │ 0.6174* (0.3743) │ 0.8618 (0.1071) │ 0.7472 (0.1625) │ 0.6438 (0.3397) |
| 2024 | DeepLab V2 baseline | Pixel Accuracy | 0.5732 | Brain-tumor semantic segmentation on BRATS; compared as a segmentation-model baseline. … | Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic SegmentationSource quoteL141: 0.5321, SegNet is 0.5411, U-Net is 0.5531, while DeepLab V1 and DeepLab V2 are 0.5622 and 0.5732 respectively. It can be seen that our model has improved by 0.0089 compared to |
| 2024 | DeepLab V2 baseline | Recall | 0.5478 | Brain-tumor semantic segmentation on BRATS; compared as a segmentation-model baseline. … | Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic SegmentationSource quoteL145: DeepLab V1 and DeepLab V2 are 0.5431 and 0.5478 respectively. The improvement in recall indicates that our model has a higher ability to identify and detect actual brain tumor regions. A higher recall rate is crucial for brain tumor segmentation because it directly affects the detection rate of tumor areas, can reduce the risk of missed detection, and improve the overall recognition ability of tumors. Taking pixel accuracy and recall into account, our model shows clear advantages in both metrics. This not only shows the overall performance improvement of the model in the segmentation task, but also shows that our method achieves a good balance between the capture of fine-grained features and the understanding of global context. The improved model is able to provide more accurate and comprehensive segmentation results when dealing with different regions of brain tumors. The success of our method may be due to innovations in network architecture, loss function design, or training strategies, which enhance the model's expressive ability and generalization ability, resulting in excellent performance in experiments on the BRATS dataset. In order to show our experimental results more intuitively, we use a bar chart to show the results, as shown in Figure 3. |
| 2024 | Scratch (SwinUNETR; no pre-training) baseline | Avg. score | 90.0 | fine-tuned · backbone=SwinUNETR · pretraining=none | Primitive Geometry Segment Pre-training for 3D Medical Image SegmentationSource quoteL304: Scratch │ -- │ 88.1 │ 84.8 │ 91.3 │ 88.1 │ 90.0 │ 86.8 │ 92.9 │ 90.3 |
| 2024 | DinoV2-L with Rein-Lora baseline | DG performance score | 63.49 | labels=binary lesion/background · backbone=DinoV2-L · adaptation=Rein-Lora · source-modality=T1w · target-modality=FLAIR | Do Vision Foundation Models Enhance Domain Generalization in Medical Image Segmentation?Source quoteL353: Rein-Lora │ DinoV2-L │ 82.95 │ 63.49 |
| 2024 | Vanilla UNet baseline | DG performance score | 54.84 | model=Vanilla UNet · labels=binary lesion/background · source-modality=T1w · target-modality=FLAIR | Do Vision Foundation Models Enhance Domain Generalization in Medical Image Segmentation?Source quoteL360: N/A │ Vanilla UNet │ 81.86 │ 54.84 |
| 2024 | DinoV2-L with Rein-Lora baseline | DG performance score | 38.19 | labels=binary lesion/background · backbone=DinoV2-L · adaptation=Rein-Lora · source-modality=FLAIR · target-modality=T1w | Do Vision Foundation Models Enhance Domain Generalization in Medical Image Segmentation?Source quoteL365: Rein-Lora │ DinoV2-L │ 38.19 │ 91.30 |
| 2024 | Vanilla UNet baseline | DG performance score | 19.79 | model=Vanilla UNet · labels=binary lesion/background · source-modality=FLAIR · target-modality=T1w | Do Vision Foundation Models Enhance Domain Generalization in Medical Image Segmentation?Source quoteL372: N/A │ Vanilla UNet │ 19.79 │ 90.48 |
| 2024 | FL baseline | DSC | 0.848 | backbone=UNet · training=2D slices · evaluation=3D volumes | Neighbor-aware calibration of segmentation networks with penalty-based constraintsSource quoteL238: Mean │ 0.789 │ 6.96 │ \und{0.848} │ 9.00 │ 0.808 │ 8.71 │ 0.820 │ 7.78 │ 0.801 │ 8.44 │ 0.838 │ 7.94 │ 0.850 │ 5.78 |
| 2024 | True Data baseline | Dice | 72.90% | split: test · training-data=real | Generative Enhancement for 3D Medical ImagesSource quoteL321: True Data │ 72.90 │ / │ 8.89 │ / |
| 2024 | True Data baseline | HD95 | 8.89 mm | split: test · training-data=real | Generative Enhancement for 3D Medical ImagesSource quoteL321: True Data │ 72.90 │ / │ 8.89 │ / |
| 2024 | Reconstructed Data of Baseline (Make-A-Volume) baseline | Dice | 59.70% | split: test · data-method=Make-A-Volume · training-data=reconstructed | Generative Enhancement for 3D Medical ImagesSource quoteL323: Reconstructed Data of Baseline │ 59.70 │ -13.20 │ 12.44 │ 3.55 |
| 2024 | Reconstructed Data of Baseline (Make-A-Volume) baseline | HD95 | 12.44 mm | split: test · data-method=Make-A-Volume · training-data=reconstructed | Generative Enhancement for 3D Medical ImagesSource quoteL323: Reconstructed Data of Baseline │ 59.70 │ -13.20 │ 12.44 │ 3.55 |
| 2024 | MT baseline | Dice | 63.52% | semi-supervised · labeled-unlabeled=1/249 | Concatenate, Fine-tuning, Re-training: A SAM-enabled Framework for Semi-supervised 3D Medical Image SegmentationSource quoteL461: MT \scalebox{0.7}{[NIPS'17]~\cite{tarvainen2017mean}} │ 63.52 │ 50.59 │ 20.59 │ 47.54 |
| 2024 | TPDM (1-slice input) baseline | Test 3D PSNR | 10.48 | split: test · sequence=FLAIR T2 · input-slices=1 | X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion ModelsSource quoteL130: TPDM \cite{TPDM} │ 10.48 │ 9.29 │ 10.86 │ 9.99 │ 11.33 │ 11.09 │ 14.13 │ 12.62 │ 16.65 │ 15.88 │ 31.48 │ 21.70 |
| 2024 | HA-GAN baseline | MS-SSIM | 0.999 | Mean MS-SSIM over 1k generated images; resolution is not specified for this score. | WDM: 3D Wavelet Diffusion Models for High-Resolution Medical Image SynthesisSource quoteL130: \subsubsection{Discussion} (1) Our proposed method outperforms HA-GAN \cite{sun2022hierarchical} on both FID and MS-SSIM metrics. While HA-GAN offers a slightly reduced memory footprint at higher resolutions, we found that it tends to suffer from severe mode collapse, indicated by a high MS-SSIM score of 0.999 on BraTS. As HA-GAN does not require iterative sampling, it is the method with the shortest inference time of \SI{0.4}{\second}/\SI{3}{\second} at the respective resolutions. |
| 2023 | Proposed equality-constraint linear-penalty method on logits (λ=0.1) proposed | ECE | 0.112 | class=foreground · lambda=0.1 · training=2D slices · evaluation=3D volumes | Trust your neighbours: Penalty-based constraints for model calibrationSource quoteL178: Ours (\lambda=0.1) │ 0.868 │ 4.88 │ 0.033 │ 0.031 │ 0.854 │ 2.55 │ 0.048 │ 0.061 │ 0.850 │ 5.78 │ 0.112 │ 0.097 |
| 2023 | coreset lifelong learning model (10x compression) proposed | mean pixel error distance | 12.93 pixel | compression=10x | Selective experience replay compression using coresets for lifelong deep reinforcement learning in medical imagingSource quoteL7: We evaluated the coreset lifelong deep reinforcement learning technique on the brain tumor segmentation (BRATS) dataset for the task of ventricle localization and on the whole-body MRI for localization of left knee cap, left kidney, right trochanter, left lung, and spleen. The coreset lifelong learning models trained on a sequence of 10 different brain MR imaging environments demonstrated excellent performance localizing the ventricle with a mean pixel error distance of 12.93, 13.46, 17.75, and 18.55 for the compression ratios of 10x, 20x, 30x, and 40x, respectively. In comparison, the conventional lifelong learning model localized the ventricle with a mean pixel distance of 10.87. Similarly, the coreset lifelong learning models trained on whole-body MRI demonstrated no significant difference (p=0.28) between the 10x compressed coreset lifelong learning models and conventional lifelong learning models for all the landmarks. The mean pixel distance for the 10x compressed models across all the landmarks was 25.30, compared to 19.24 for the conventional lifelong learning models. Our results demonstrate that the potential of the coreset-based ERB compression method for compressing experiences without a significant drop in performance. |
| 2023 | coreset lifelong learning model (40x compression) proposed | mean pixel error distance | 18.55 pixel | compression=40x | Selective experience replay compression using coresets for lifelong deep reinforcement learning in medical imagingSource quoteL7: We evaluated the coreset lifelong deep reinforcement learning technique on the brain tumor segmentation (BRATS) dataset for the task of ventricle localization and on the whole-body MRI for localization of left knee cap, left kidney, right trochanter, left lung, and spleen. The coreset lifelong learning models trained on a sequence of 10 different brain MR imaging environments demonstrated excellent performance localizing the ventricle with a mean pixel error distance of 12.93, 13.46, 17.75, and 18.55 for the compression ratios of 10x, 20x, 30x, and 40x, respectively. In comparison, the conventional lifelong learning model localized the ventricle with a mean pixel distance of 10.87. Similarly, the coreset lifelong learning models trained on whole-body MRI demonstrated no significant difference (p=0.28) between the 10x compressed coreset lifelong learning models and conventional lifelong learning models for all the landmarks. The mean pixel distance for the 10x compressed models across all the landmarks was 25.30, compared to 19.24 for the conventional lifelong learning models. Our results demonstrate that the potential of the coreset-based ERB compression method for compressing experiences without a significant drop in performance. |
| 2023 | CG-CDM proposed | infer time | 2.78s | weakly-supervised · Q=400 · R=10 · s=10 · τ=0.95 · denoising-iterations=10 | Conditional Diffusion Models for Weakly Supervised Medical Image SegmentationSource quoteL186: CG-CDM │ 0.563±0.023 │ 0.450±0.012 │ 19.2±3.2 │ 2.78s |
| 2023 | MMCCD proposed | DICE | 0.6092 | unsupervised · input-modality=FLAIR | Modality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRISource quoteL191: MMCCD │ 0.6092 │ 0.9409 │ 0.4682 │ 0.6505 │ 0.6336 │ 6.1171 |
| 2023 | MMCCD proposed | Jac | 0.4682 | unsupervised · input-modality=FLAIR | Modality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRISource quoteL191: MMCCD │ 0.6092 │ 0.9409 │ 0.4682 │ 0.6505 │ 0.6336 │ 6.1171 |
| 2023 | Ensemble ResNet-34x50 `and' proposed | Best AVG DSC | 70.3 | weakly-supervised · backbone=ResNet-34 + ResNet-50 ensemble · resolution=34x50 · supervision=image-level labels | Exploring Weakly Supervised Semantic Segmentation Ensembles for Medical Imaging SystemsSource quoteL232: Ensemble ResNet-34x50 `and' │ 70.3 │ 54.2 |
| 2023 | SyMOT-Flow proposed | SSIM ↑ | 0.83 | split: test · encoding=VQ-VAE-2 · subgroup=T2 | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteL529: Ours │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
| 2023 | ViT-AE++ proposed | AUC | 0.767 | backbone=ViT-AE · dimension=3D · training-samples-per-fold=260 | ViT-AE++: Improving Vision Transformer Autoencoder for Self-supervised Medical Image RepresentationsSource quoteL146: ViT-AE++(ours) │ {0.767} │ 0.846 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 30.68 dB | split: test · scale=8x out-of-scale · target-modality=T2 · reference-modality=T1 | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL576: 30.68 |
| 2023 | LKA-E proposed | HD95 (WT) | 2.449 | split: test | Large-kernel Attention for Efficient and Robust Brain Lesion SegmentationSource quoteL147: LKA-E (Ours) │ \multicolumn{1}{l|}{0.888} │ \multicolumn{1}{l|}{0.932} │ 0.939 │ \multicolumn{1}{l|}{1.414} │ \multicolumn{1}{l|}{2.000} │ 2.449^* |
| 2023 | Chebyshev confidence guided SFDA framework (full configuration) proposed | Dice | 77.10 | adaptation=source-free domain adaptation · evaluation=average over scenarios | A Chebyshev Confidence Guided Source-Free Domain Adaptation Framework for Medical Image SegmentationSource quoteL316: \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 89.28 │ 6.52 │ 77.10 │ 10.60 |
| 2023 | Chebyshev confidence guided SFDA framework (full configuration) proposed | ASD | 10.60 | adaptation=source-free domain adaptation · evaluation=average over scenarios | A Chebyshev Confidence Guided Source-Free Domain Adaptation Framework for Medical Image SegmentationSource quoteL316: \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 89.28 │ 6.52 │ 77.10 │ 10.60 |
| 2023 | GL-MAE (ViT-T; listed as Ours) proposed | Avg Dice score | 78.31% | backbone=ViT-T | Advancing Volumetric Medical Image Segmentation via Global-Local Masked AutoencoderSource quoteL234: Ours │ ViT-T │ 83.00 │ 91.15 │ 60.46 │ 78.31 |
| 2023 | K-CROSS proposed non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.1851 | subset=1,200 images per generator · generator=CycleGAN · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147} |
| 2023 | K-CROSS proposed non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.2246 | subset=1,200 images per generator · generator=MUNIT · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147} |
| 2023 | K-CROSS proposed non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.2147 | subset=1,200 images per generator · generator=UNIT · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147} |
| 2023 | ProM (2D) proposed | Dice | 0.706 | acceleration=x32 · mask-variant=2D | Constrained Probabilistic Mask Learning for Task-specific Undersampled MRI ReconstructionSource quoteL226: \multirow{2}{*}{\texttt{x32}} │ Dice │ \uparrow \,\, │ 0.644 │ 0.399 │ 0.592 │ 0.587 │ 0.727 │ 0.580 │ 0.315 │ 0.537 │ 0.483 │ 0.706 |
| 2023 | ProM (2D) proposed | IoU | 0.608 | acceleration=x32 · mask-variant=2D | Constrained Probabilistic Mask Learning for Task-specific Undersampled MRI ReconstructionSource quoteL227: IoU │ \uparrow \,\, │ 0.517 │ 0.301 │ 0.466 │ 0.460 │ 0.606 │ 0.472 │ 0.226 │ 0.428 │ 0.374 │ 0.608 |
| 2023 | Ours ensemble (1/4 train/validation task split) proposed | Pixel-wise AP (average precision) | 76.2 | split: test · ensemble=yes · modality=brain MRI · task-split=1/4 train/validation | Many tasks make light work: Learning to localise medical anomalies from multiple synthetic tasksSource quoteL229: \multicolumn{3}{l}{Ours} │ 87.6/92.2 │ 62.0/84.6 │ 76.2/99.1 │ 45.9/97.9 │ 78.4/76.6 │ 71.2/81.1 │ 21.1/75.6 │ 21.4/81.2 |
| 2023 | E2ENet (DSFF enabled; restricted depth-shift enabled) proposed | mDice | 74.5% | split: val · 5-fold-cross-validation · DSFF=enabled · kernel-size=1×3×3 · restricted-depth-shift=enabled | E2ENet: Dynamic Sparse Feature Fusion for Accurate and Efficient 3D Medical Image SegmentationSource quoteL349: \CheckmarkBold │ \CheckmarkBold │ (1×3×3) │ 81.2 │ 62.7 │ 79.5 │ 74.5 │ 11.24 │ 1067.06 |
| 2023 | Cyclic UNet ablation | DICE | 0.5810 | unsupervised · input-modality=FLAIR | Modality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRISource quoteL190: Cyclic UNet │ 0.5810 │ 0.9409 │ 0.4470 │ 0.6545 │ 0.5823 │ 6.3487 |
| 2023 | Cyclic UNet ablation | Jac | 0.4470 | unsupervised · input-modality=FLAIR | Modality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRISource quoteL190: Cyclic UNet │ 0.5810 │ 0.9409 │ 0.4470 │ 0.6545 │ 0.5823 │ 6.3487 |
| 2023 | Vanilla ViT-AE ablation | AUC | 0.696 | backbone=ViT-AE · dimension=3D · training-samples-per-fold=260 | ViT-AE++: Improving Vision Transformer Autoencoder for Self-supervised Medical Image RepresentationsSource quoteL144: Vallina ViT-AE │ 0.696 │ 0.828 |
| 2023 | MAE3D (ViT-T) | Avg Dice score | 77.29% | backbone=ViT-T | Advancing Volumetric Medical Image Segmentation via Global-Local Masked AutoencoderSource quoteL233: MAE3D │ ViT-T │ 82.34 │ 90.35 │ 59.18 │ 77.29 |
| 2023 | SVLS (σ=2) baseline | ECE | 0.146 | class=foreground · sigma=2 · training=2D slices · evaluation=3D volumes | Trust your neighbours: Penalty-based constraints for model calibrationSource quoteL175: SVLS \cite{islam2021spatially} (\sigma=2) │ 0.857 │ 5.72 │ 0.039 │ 0.036 │ 0.824 │ 2.81 │ 0.091 │ 0.083 │ 0.801 │ 8.44 │ 0.146 │ 0.111 |
| 2023 | conventional lifelong learning model baseline | mean pixel distance | 10.87 pixel | Reported as the conventional lifelong learning comparison to the coreset models. | Selective experience replay compression using coresets for lifelong deep reinforcement learning in medical imagingSource quoteL7: We evaluated the coreset lifelong deep reinforcement learning technique on the brain tumor segmentation (BRATS) dataset for the task of ventricle localization and on the whole-body MRI for localization of left knee cap, left kidney, right trochanter, left lung, and spleen. The coreset lifelong learning models trained on a sequence of 10 different brain MR imaging environments demonstrated excellent performance localizing the ventricle with a mean pixel error distance of 12.93, 13.46, 17.75, and 18.55 for the compression ratios of 10x, 20x, 30x, and 40x, respectively. In comparison, the conventional lifelong learning model localized the ventricle with a mean pixel distance of 10.87. Similarly, the coreset lifelong learning models trained on whole-body MRI demonstrated no significant difference (p=0.28) between the 10x compressed coreset lifelong learning models and conventional lifelong learning models for all the landmarks. The mean pixel distance for the 10x compressed models across all the landmarks was 25.30, compared to 19.24 for the conventional lifelong learning models. Our results demonstrate that the potential of the coreset-based ERB compression method for compressing experiences without a significant drop in performance. |
| 2023 | DDPM baseline | DICE | 0.5662 | split: test · unsupervised · input-modality=FLAIR | Modality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRISource quoteL188: \textbf{DDPM\cite{pinaya_fast_2022}} │ 0.5662 │ 0.9267 │ 0.4172 │ 0.5958 │ 0.5949 │ 6.5021 |
| 2023 | DDPM baseline | Jac | 0.4172 | split: test · unsupervised · input-modality=FLAIR | Modality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRISource quoteL188: \textbf{DDPM\cite{pinaya_fast_2022}} │ 0.5662 │ 0.9267 │ 0.4172 │ 0.5958 │ 0.5949 │ 6.5021 |
| 2023 | WSS-CMER baseline | Best AVG DSC | 59.7 | weakly-supervised · supervision=image-level labels | Exploring Weakly Supervised Semantic Segmentation Ensembles for Medical Imaging SystemsSource quoteL225: WSS-CMER │ 59.7 │ 42.6 |
| 2023 | UNIT baseline | SSIM ↑ | 0.77 | split: test · encoding=VQ-VAE-2 · subgroup=T2 | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteL527: UNIT \cite{liu2017unsupervised} │ 0.79 │ 111.93 │ 0.77 │ 82.23 │ 0.68 │ 116.32 │ 0.48 │ 105.75 |
| 2023 | MoCO-v3 baseline | AUC | 0.795 | dimension=3D · training-samples-per-fold=260 | ViT-AE++: Improving Vision Transformer Autoencoder for Self-supervised Medical Image RepresentationsSource quoteL142: MoCO-v3 │ 0.795 │ 0.734 |
| 2023 | LTE* [13] (SwinIR backbone; reference and target concatenated) baseline | PSNR | 29.97 dB | scale=8x out-of-scale · backbone=SwinIR · target-modality=T2 · reference-modality=T1 | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL565: 29.97 |
| 2023 | Swin-UNETR baseline | HD95 (WT) | 3.606 | split: test · backbone=Swin-UNETR | Large-kernel Attention for Efficient and Robust Brain Lesion SegmentationSource quoteL146: Swin-UNETR │ \multicolumn{1}{l|}{0.894} │ \multicolumn{1}{l|}{0.932} │ 0.938 │ \multicolumn{1}{l|}{1.414} │ \multicolumn{1}{l|}{2.236} │ 3.606 |
| 2023 | DIST baseline non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.1901 | generator=CycleGAN · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL372: DIST~\cite{Ding2022ImageQA} │ 0.3012 │ 0.1901 │ 0.1725 │ 0.2291 │ 0.2387 │ 0.2230 |
| 2023 | LPIP baseline non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.2285 | generator=MUNIT · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL371: LPIP~\cite{Zhang2018TheUE} │ 0.3023 │ 0.1921 │ 0.1786 │ 0.2285 │ 0.2398 │ 0.2327 |
| 2023 | DIST baseline non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.2230 | generator=UNIT · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL372: DIST~\cite{Ding2022ImageQA} │ 0.3012 │ 0.1901 │ 0.1725 │ 0.2291 │ 0.2387 │ 0.2230 |
| 2023 | Complementary baseline | average MSE (brain mask) | 0.04 | split: test · region=brain mask · normalization=[0,1] | MRI Scan Synthesis Methods Based on Clustering and Pix2PixSource quoteL206: The second baseline, Complementary\xspace evaluates to reasonable MSEs, e.g., it has 0.04 on average in the brain mask and 0.03 in the tumor area on \texttt{testBraTS\xspace}\xspace. All our methods improve upon these values as can be seen in \cref{fig:test_mse}. The scans generated by Pix2Pix\xspace have a better MSE than BrainClustering\xspace in the brain mask area. In the tumor area, the average MSE of both methods is comparable, and it is overall better, although the median MSE is still below 0.02. The best results are produced by Pix2Pix\xspace ResNet\ with \lambda=500 and \gamma =500, but Pix2Pix\xspace UNet\ with \lambda=100 and \gamma=0 also produces good results. Notably, BrainClustering\xspace with Search\xspace with 10 patients and 5 clusters achieves the best median MSE in the tumor area among all methods we tested. We conclude that it is possible to compute synthesized scans that closely resemble the true scan. |
| 2022 | DDPM (f=4) (b) [Ours] proposed | theoretically best possible DICE-score (\lceil DICE \rceil) | 0.469 | unsupervised · model-variant=DDPM (f=4) (b) | Fast Unsupervised Brain Anomaly Detection and Segmentation with Diffusion ModelsSource quoteL91: DDPM (f=4) (b) [Ours] │ 0.208^\dagger │ 0.204 │ 0.469^\dagger │ 0.272 |
| 2022 | UNETR+MAE proposed | average DSC | 78.91% | self-pretraining · backbone=UNETR · mask-ratio=12.5% | Self Pre-Training with Masked Autoencoders for Medical Image Classification and SegmentationSource quoteL124: UNETR+MAE │ 78.91 │ 7.22 │ 90.84 │ 7.04 │ 63.88 │ 7.15 │ 82.00 │ 7.13 |
| 2022 | PseudoClick (C+L, HRNet32) proposed | mIoU@3 | 64.0% | Cross-domain human evaluation; trained on C+L and applied without finetuning; 3 human c… | PseudoClick: Interactive Image Segmentation with Click ImitationSource quoteL230: Ours │ C+L │ N/A │ HRNet32 │ 64.0 │ 80.1 |