BraTS

93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.91.0201820222025SynNet (Weighted L₂ loss): 0.69 (2018)SynNet (Joint Loss): 0.7 (2018)SynNet (Weighted L₂ loss): 0.77 (2018)SynNet (Joint Loss): 0.86 (2018)ReMIC: 0.9618 (2021)TransCSCN: 0.943 (2022)SyMOT-Flow: 0.83 (2023)MRNet: 0.9411 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 18 of 18 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposedMean PSNR27.3 dBsplit: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposedMean SSIM0.95split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2026MRIComp4Flow WFM trained on JPEG2000-compressed data at 200:1 proposedPSNR24.65 dBsplit: val · modality=T1n · compression=JPEG2000 200:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L125: 200 │ 23.25 │ 24.65 │ 23.07 │ 22.63 │ 0.879 │ 0.968 │ 0.937 │ 0.902
2026MRIComp4Flow WFM trained on JPEG2000-compressed data at 400:1 proposedPSNR20.94 dBsplit: val · modality=T1n · compression=JPEG2000 400:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L126: 400 │ 19.30 │ 20.94 │ 21.29 │ 17.18 │ 0.852 │ 0.829 │ 0.814 │ 0.750
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baselineMean PSNR27.0 dBsplit: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressedMRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baselineMean SSIM0.96split: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressedMRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2023E2ENet (DSFF enabled; restricted depth-shift enabled) proposedmDice74.5%split: val · 5-fold-cross-validation · DSFF=enabled · kernel-size=1×3×3 · restricted-depth-shift=enabledE2ENet: Dynamic Sparse Feature Fusion for Accurate and Efficient 3D Medical Image Segmentation
Source quote
L349: \CheckmarkBold │ \CheckmarkBold │ (1×3×3) │ 81.2 │ 62.7 │ 79.5 │ 74.5 │ 11.24 │ 1067.06
2021IGS-optimized undersampling pattern (table label “Ours”) proposedF1-score0.877split: val · loss=Soft Hinge · backbone=ResNet-18 · validation=5-fold cross-validation · acceleration=×4Optimal MRI Undersampling Patterns for Ultimate Benefit of Medical Vision Tasks
Source quote
L270: Soft Hinge │ 0.834 │ 0.848 │ 0.877
2021Trad.+3DSiam+SE proposedSpecificity0.711split: val · validation=stratified cross-validation · label_fraction=fullImbalance-Aware Self-supervised Learning for 3D Radiomic Representations
Source quote
L139: Trad.+3DSiam+SE │ 0.916/0.711 │ 0.848/0.763 │ 0.538/0.375 │ 0.519/0.350
2021Trad.+3DSiam+SE proposedSpecificity0.763split: val · validation=stratified cross-validation · label_fraction=50%Imbalance-Aware Self-supervised Learning for 3D Radiomic Representations
Source quote
L139: Trad.+3DSiam+SE │ 0.916/0.711 │ 0.848/0.763 │ 0.538/0.375 │ 0.519/0.350
2021Trad.+3DSiam ablationSpecificity0.645split: val · component=SE removed · validation=stratified cross-validation · label_fraction=fullImbalance-Aware Self-supervised Learning for 3D Radiomic Representations
Source quote
L138: Trad.+3DSiam │ 0.904/0.645 │ 0.804/0.566 │ 0.495/0.350 │ 0.486/0.350
2021Center undersampling pattern baselineF1-score0.848split: val · loss=Soft Hinge · backbone=ResNet-18 · validation=5-fold cross-validation · acceleration=×4Optimal MRI Undersampling Patterns for Ultimate Benefit of Medical Vision Tasks
Source quote
L270: Soft Hinge │ 0.834 │ 0.848 │ 0.877
2021Supervised Learning baselineSpecificity0.566split: val · validation=stratified cross-validation · label_fraction=50%Imbalance-Aware Self-supervised Learning for 3D Radiomic Representations
Source quote
L142: Supervised Learning │ {0.888/0.711} │ 0.804/0.566 │ 0.526/0.375 │ 0.467/0.325
2020ConResNet (context residual mapping and context attention mapping) proposedDice score, ET81.87%split: val · subset=35 randomly selected training casesInter-Slice Context Residual Learning for 3D Medical Image Segmentation
Source quote
L276: ConResNet │ \checkmark │ \checkmark │ 81.87 │ 89.77 │ 88.14 │ 3.14 │ 5.08 │ 5.16
2020ConResNet (context residual mapping and context attention mapping) proposedDice score, WT89.77%split: val · subset=35 randomly selected training casesInter-Slice Context Residual Learning for 3D Medical Image Segmentation
Source quote
L276: ConResNet │ \checkmark │ \checkmark │ 81.87 │ 89.77 │ 88.14 │ 3.14 │ 5.08 │ 5.16
2020ConResNet (context residual mapping and context attention mapping) proposedDice score, TC88.14%split: val · subset=35 randomly selected training casesInter-Slice Context Residual Learning for 3D Medical Image Segmentation
Source quote
L276: ConResNet │ \checkmark │ \checkmark │ 81.87 │ 89.77 │ 88.14 │ 3.14 │ 5.08 │ 5.16
2019Modified U-Net + \(\mathcal{L}-MScnn\) proposedDice0.880split: val · semi-supervised · labeled-data=1/4Mumford-Shah Loss Functional for Image Segmentation With Deep Learning
Source quote
L346: \multicolumn{1}{l|}{{Modified U-Net + \boldsymbol{\mathcal{L}-MScnn}}} │ 0.880 │ 0.904 │ 0.858 │ 0.786
2019Modified U-Net ablationDice0.866split: val · semi-supervised · labeled-data=1/4Mumford-Shah Loss Functional for Image Segmentation With Deep Learning
Source quote
L345: \multicolumn{1}{l|}{Modified U-Net} │ 0.866 │ 0.927 │ 0.813 │ 0.764