BraTS

93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.91.0201820222025SynNet (Weighted L₂ loss): 0.69 (2018)SynNet (Joint Loss): 0.7 (2018)SynNet (Weighted L₂ loss): 0.77 (2018)SynNet (Joint Loss): 0.86 (2018)ReMIC: 0.9618 (2021)TransCSCN: 0.943 (2022)SyMOT-Flow: 0.83 (2023)MRNet: 0.9411 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 69 of 69 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026JiT-L/16 (direct IN transfer) proposedgFID40.17split: test · in-initialized-trainingFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L884: 40.17
2026JiT-B/16 (IN initialization) proposedgFID31.73split: test · fine-tunedFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L865: 31.73
2026VariaFlow proposedAUROC0.78split: test · cross-domainVariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection
Source quote
L34: the highest AUROC (0.94, 0.80, 0.78) on each and the high-
2026GALoss[11] (ECCV 2024)Dice83.49%split: testScale-aware adaptive supervised network with limited medical annotations
Source quote
L1314: 83.49
2026SASNetDice85.84%split: testScale-aware adaptive supervised network with limited medical annotations
Source quote
L1321: 85.84
2026JiT-B/16 (random initialization; RADIN-pretrained) baselinegFID36.73split: test · medical-pretrained-then-fine-tunedFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L853: 36.73
2026JiT-L/16 (single-channel BRATS-pretrained) baselinegFID50.90split: test · medical-pretrainedFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L880: 50.90
2026JiT-L/16 (RADIN-pretrained) baselinegFID75.40split: test · medical-pretrainedFrom Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation
Source quote
L876: 75.40
2026REFLECT baselineAUROC0.6828split: test · cross-domainVariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection
Source quote
L680: 0.6828 AUROC on BraTS. IterMask2 shows a similar trend,
2025fastWDM3D (T=2) proposedAST (average sampling time per volume)1.81 ssplit: test · sampling-steps=2fastWDM3D: Fast and Accurate 3D Healthy Tissue Inpainting
Source quote
L134: Ours (fastWDM3D (T=2)) │ 0.86 ± 0.12 │ 0.0079 ± 0.0063 │ 22.26 ± 3.97 │ \hphantom{0}\SI{1.81}{\second}
2025IterMask3D proposedDSC69.7split: test · test-time-refinement · tuning=test-set, 3 standard deviations · modality=FLAIR · training-data=cognitively normal ADNI/OASIS · dimensionality=3DIterMask3D: Unsupervised Anomaly Detection and Segmentation with Test-Time Iterative Mask Refinement in 3D Brain MR
Source quote
L534: \multicolumn{1}{l|}{IterMask3D} │ 69.7 │ 99.2 │ 72.7 │ 71.1 │ 56.7 │ 32.2 │ 5.1
2025SIPL proposedDSC83.0%split: test · regions=whole tumor, enhancing tumor, tumor core · train-val-test-split=80:5:15Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype Learning
Source quote
L197: SIPL (ours) │ 83.0 │ --
2025VIViT+SSL proposedMean Dice0.883split: test · resolution=128×128×128VIViT: Variable-Input Vision Transformer Framework for 3D MR Image Segmentation
Source quote
L130: VIViT+SSL │ 0.624 │ 0.871 │ 0.893 │ 0.884 │ 0.883
2025SpectMamba proposedmAP75.34split: test · epochs=200 · pretraining=noneSpectMamba: Integrating Frequency and State Space Models for Enhanced Medical Image Detection
Source quote
L275: {SpectMamba} │ 89.83 │ 78.64 │ 57.54 │ 75.34 │ 95.35 │ 85.64 │ 68.24 │ 83.08
2025WDM3D baselineAST (average sampling time per volume)5 minutesplit: test · loss=MSE on wavelet coefficients · sampling-steps=1000 · variance-schedule=linearfastWDM3D: Fast and Accurate 3D Healthy Tissue Inpainting
Source quote
L133: WDM3D \cite{durrer2024denoising} │ 0.61 ± 0.16 │ 0.1060 ± 0.0757 │ 10.57 ± 3.20 │ \hphantom{0}\SI{5}{\minute}
2025DAE (tuned) baselineDSC66.7split: test · test-time-tuned · tuning=test-set, 3 standard deviations · modality=FLAIR · dimensionality=3DIterMask3D: Unsupervised Anomaly Detection and Segmentation with Test-Time Iterative Mask Refinement in 3D Brain MR
Source quote
L533: \multicolumn{1}{l|}{DAE (tuned)} │ 66.7 │ 99.1 │ 71.1 │ 68.7 │ 52.5 │ 34.5 │ 6.2
2025UNETR++ baselineDSC82.8%split: test · regions=whole tumor, enhancing tumor, tumor core · train-val-test-split=80:5:15Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype Learning
Source quote
L196: UNETR++ │ 82.8 │ 0.0297
2025SwinUNETR baselineMean Dice0.874split: testVIViT: Variable-Input Vision Transformer Framework for 3D MR Image Segmentation
Source quote
L126: SwinUNETR │ 0.611 │ 0.873 │ 0.883 │ 0.867 │ 0.874
2024QCResUNet proposedPearson r (DSC prediction)0.968split: test · metric-target=DSC · prediction-level=subject-level · segmentation-models=nnUNet, nnFormerQCResUNet: Joint subject-level and voxel-level segmentation quality prediction
Source quote
L279: Specifically, on the BraTS internal testing set with segmentations generated by nnUNet and nnFormer, the proposed method achieved a small mean MAE of 0.056 and 0.064 for NSD and DSC prediction, respectively. The predicted NSD and DSC also showed a strong correlation with the corresponding ground truth, achieving Pearson r values of 0.958 and 0.968, respectively. Importantly, the proposed method generalized well for segmentation produced by different methods (i.e., DeepMedic), which had not been used during training, achieving an average MAE of 0.074 and 0.062 for NSD and DSC prediction. Similarly, the predicted NSD and DSC showed a strong correlation with their ground truth with Pearson r values of 0.937 and 0.962, respectively.
2024McCaD proposedDice score0.8004split: test · retained-contrasts=T1w, FLAIR · synthetic-contrast=T2w · segmentation-target=whole-tumorMcCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI Synthesis
Source quote
L210: AttGAN │ DDPM │ Hi-Net │ MM-GAN │ McCaD │ Complete T2w │ 0.7692 │ 0.7987 │ 0.7921 │ 0.7991 │ 0.8004 │ 0.8188 T2w + FLAIR │ 0.6974 │ 0.6262 │ 0.7401 │ 0.7449 │ 0.7602 │ 0.8188
2024HF-GAN (ours) imputation proposedDice (ET)0.6438split: test · evaluation=after imputation · architecture=2D slice-based · test-subjects=85 · segmentation-region=ETPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L284: \multicolumn{4}{c|}{Average} │ 0.6196* (0.3202) │ 0.5130* (0.3041) │ 0.4957* (0.3598) │ 0.8436* (0.1279) │ 0.7247* (0.1728) │ 0.6139* (0.3619) │ 0.8405* (0.1356) │ 0.7178* (0.1766) │ 0.6313* (0.3446) │ 0.8632 (0.1033) │ 0.7488 (0.1588) │ 0.6174* (0.3743) │ 0.8618 (0.1071) │ 0.7472 (0.1625) │ 0.6438 (0.3397)
2024MRNet proposedPSNR31.2852split: test · plane=axial · direction=FLAIR-to-T2MRNet: Multifaceted Resilient Networks for Medical Image-to-Image Translation
Source quote
L269: OURS │ 31.2852 │ 0.9411 │ \checkmark
2024MRNet proposedSSIM0.9411split: test · plane=axial · direction=FLAIR-to-T2MRNet: Multifaceted Resilient Networks for Medical Image-to-Image Translation
Source quote
L269: OURS │ 31.2852 │ 0.9411 │ \checkmark
2024HiDiff proposed non-standard sliceAverage Dice51.77split: test · subset=small tumors; pixel-wise tumor size <100HiDiff: Hybrid Diffusion Framework for Medical Image Segmentation
Source quote
L506: {{HiDiff}\xspace (ours)} │ 51.77 │ 8.76(20.13%) │ 59.00 │ 47.30 │ 49.00
2024X-Diffusion (1-slice input) proposedTest 3D PSNR23.10split: test · sequence=FLAIR T2 · input-slices=1X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
Source quote
L131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01
2024Complete baseline non-standard sliceDice score0.8188split: test · contrast-input=all three ground-truth contrasts · segmentation-target=whole-tumorMcCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI Synthesis
Source quote
L210: AttGAN │ DDPM │ Hi-Net │ MM-GAN │ McCaD │ Complete T2w │ 0.7692 │ 0.7987 │ 0.7921 │ 0.7991 │ 0.8004 │ 0.8188 T2w + FLAIR │ 0.6974 │ 0.6262 │ 0.7401 │ 0.7449 │ 0.7602 │ 0.8188
2024Hyper-GAE imputation baselineDice (ET)0.6174split: test · evaluation=after imputation · architecture=3D volumetric · test-subjects=85 · segmentation-region=ETPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L284: \multicolumn{4}{c|}{Average} │ 0.6196* (0.3202) │ 0.5130* (0.3041) │ 0.4957* (0.3598) │ 0.8436* (0.1279) │ 0.7247* (0.1728) │ 0.6139* (0.3619) │ 0.8405* (0.1356) │ 0.7178* (0.1766) │ 0.6313* (0.3446) │ 0.8632 (0.1033) │ 0.7488 (0.1588) │ 0.6174* (0.3743) │ 0.8618 (0.1071) │ 0.7472 (0.1625) │ 0.6438 (0.3397)
2024True Data baselineDice72.90%split: test · training-data=realGenerative Enhancement for 3D Medical Images
Source quote
L321: True Data │ 72.90 │ / │ 8.89 │ /
2024True Data baselineHD958.89 mmsplit: test · training-data=realGenerative Enhancement for 3D Medical Images
Source quote
L321: True Data │ 72.90 │ / │ 8.89 │ /
2024Reconstructed Data of Baseline (Make-A-Volume) baselineDice59.70%split: test · data-method=Make-A-Volume · training-data=reconstructedGenerative Enhancement for 3D Medical Images
Source quote
L323: Reconstructed Data of Baseline │ 59.70 │ -13.20 │ 12.44 │ 3.55
2024Reconstructed Data of Baseline (Make-A-Volume) baselineHD9512.44 mmsplit: test · data-method=Make-A-Volume · training-data=reconstructedGenerative Enhancement for 3D Medical Images
Source quote
L323: Reconstructed Data of Baseline │ 59.70 │ -13.20 │ 12.44 │ 3.55
2024TPDM (1-slice input) baselineTest 3D PSNR10.48split: test · sequence=FLAIR T2 · input-slices=1X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
Source quote
L130: TPDM \cite{TPDM} │ 10.48 │ 9.29 │ 10.86 │ 9.99 │ 11.33 │ 11.09 │ 14.13 │ 12.62 │ 16.65 │ 15.88 │ 31.48 │ 21.70
2023SyMOT-Flow proposedSSIM ↑0.83split: test · encoding=VQ-VAE-2 · subgroup=T2Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal Transport
Source quote
L529: Ours │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR30.68 dBsplit: test · scale=8x out-of-scale · target-modality=T2 · reference-modality=T1Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L576: 30.68
2023LKA-E proposedHD95 (WT)2.449split: testLarge-kernel Attention for Efficient and Robust Brain Lesion Segmentation
Source quote
L147: LKA-E (Ours) │ \multicolumn{1}{l|}{0.888} │ \multicolumn{1}{l|}{0.932} │ 0.939 │ \multicolumn{1}{l|}{1.414} │ \multicolumn{1}{l|}{2.000} │ 2.449^*
2023Ours ensemble (1/4 train/validation task split) proposedPixel-wise AP (average precision)76.2split: test · ensemble=yes · modality=brain MRI · task-split=1/4 train/validationMany tasks make light work: Learning to localise medical anomalies from multiple synthetic tasks
Source quote
L229: \multicolumn{3}{l}{Ours} │ 87.6/92.2 │ 62.0/84.6 │ 76.2/99.1 │ 45.9/97.9 │ 78.4/76.6 │ 71.2/81.1 │ 21.1/75.6 │ 21.4/81.2
2023DDPM baselineDICE0.5662split: test · unsupervised · input-modality=FLAIRModality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRI
Source quote
L188: \textbf{DDPM\cite{pinaya_fast_2022}} │ 0.5662 │ 0.9267 │ 0.4172 │ 0.5958 │ 0.5949 │ 6.5021
2023DDPM baselineJac0.4172split: test · unsupervised · input-modality=FLAIRModality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRI
Source quote
L188: \textbf{DDPM\cite{pinaya_fast_2022}} │ 0.5662 │ 0.9267 │ 0.4172 │ 0.5958 │ 0.5949 │ 6.5021
2023UNIT baselineSSIM ↑0.77split: test · encoding=VQ-VAE-2 · subgroup=T2Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal Transport
Source quote
L527: UNIT \cite{liu2017unsupervised} │ 0.79 │ 111.93 │ 0.77 │ 82.23 │ 0.68 │ 116.32 │ 0.48 │ 105.75
2023Swin-UNETR baselineHD95 (WT)3.606split: test · backbone=Swin-UNETRLarge-kernel Attention for Efficient and Robust Brain Lesion Segmentation
Source quote
L146: Swin-UNETR │ \multicolumn{1}{l|}{0.894} │ \multicolumn{1}{l|}{0.932} │ 0.938 │ \multicolumn{1}{l|}{1.414} │ \multicolumn{1}{l|}{2.236} │ 3.606
2023Complementary baselineaverage MSE (brain mask)0.04split: test · region=brain mask · normalization=[0,1]MRI Scan Synthesis Methods Based on Clustering and Pix2Pix
Source quote
L206: The second baseline, Complementary\xspace evaluates to reasonable MSEs, e.g., it has 0.04 on average in the brain mask and 0.03 in the tumor area on \texttt{testBraTS\xspace}\xspace. All our methods improve upon these values as can be seen in \cref{fig:test_mse}. The scans generated by Pix2Pix\xspace have a better MSE than BrainClustering\xspace in the brain mask area. In the tumor area, the average MSE of both methods is comparable, and it is overall better, although the median MSE is still below 0.02. The best results are produced by Pix2Pix\xspace ResNet\ with \lambda=500 and \gamma =500, but Pix2Pix\xspace UNet\ with \lambda=100 and \gamma=0 also produces good results. Notably, BrainClustering\xspace with Search\xspace with 10 patients and 5 clusters achieves the best median MSE in the tumor area among all methods we tested. We conclude that it is possible to compute synthesized scans that closely resemble the true scan.
2022DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposedMAE0.51 starssplit: test · backbone=DenseNet121 · optimizer=Ranger21Deep Quality Estimation: Creating Surrogate Models for Human Quality Ratings
Source quote
L119: 0.51
2022DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposedRMSE0.80 starssplit: test · backbone=DenseNet121 · optimizer=Ranger21Deep Quality Estimation: Creating Surrogate Models for Human Quality Ratings
Source quote
L120: 0.80
2022DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposedPearson r0.66split: test · backbone=DenseNet121 · optimizer=Ranger21Deep Quality Estimation: Creating Surrogate Models for Human Quality Ratings
Source quote
L121: 0.66
2022TransCSCN proposedPSNR (dB)39.12 dBsplit: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L439: 39.12
2022TransCSCN proposedSSIM0.943split: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L448: 0.943
2022TransCSCN proposedDice (in %)85.68%split: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L457: 85.68
2022DiffusionMBIR proposedPSNR ↑41.49split: test · orientation=axial · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953
2022DiffusionMBIR proposedPSNR ↑37.36split: test · orientation=coronal · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953
2022DiffusionMBIR proposedPSNR ↑37.18split: test · orientation=sagittal · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953
2022CSCℓ4Net baselinePSNR (dB)37.36 dBsplit: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L438: 37.36
2022CSCℓ4Net baselineSSIM0.935split: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L447: 0.935
2022CSCℓ4Net baselineDice (in %)84.07%split: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L456: 84.07
2022Score-MRI baselinePSNR ↑40.38split: test · orientation=axial · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L274: Score-MRI\cite{chung2022score} │ 40.38 │ 0.968 │ 33.97 │ 0.925 │ 34.02 │ 0.928
2022Score-MRI baselinePSNR ↑33.97split: test · orientation=coronal · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L274: Score-MRI\cite{chung2022score} │ 40.38 │ 0.968 │ 33.97 │ 0.925 │ 34.02 │ 0.928
2022Score-MRI baselinePSNR ↑34.02split: test · orientation=sagittal · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L274: Score-MRI\cite{chung2022score} │ 40.38 │ 0.968 │ 33.97 │ 0.925 │ 34.02 │ 0.928
2020ReMIC proposedNRMSE (↓)0.2008split: test · target=T1Multi-Domain Image Completion for Random Missing Input Data
Source quote
L357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}}
2020ReMIC proposedPSNR (↑)28.5508split: test · target=T1Multi-Domain Image Completion for Random Missing Input Data
Source quote
L357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}}
2020ReMIC proposedSSIM (↑)0.9618split: test · target=T1Multi-Domain Image Completion for Random Missing Input Data
Source quote
L357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}}
2019HarmonicGAN (Histogram) proposedMSE ↓216.83split: test · variant=Histogram · direction=Flair-to-T1Harmonic Unpaired Image-to-image Translation
Source quote
L269: \quad Histogram │ 6.38 │ 216.83 │ 24.34 │ 0.83 │ 5.04 │ 163.29 │ 26.72 │ 0.75
2019Concatenated two VGGs baselineclassification accuracy94.47%split: test · modalities=Flair and T1c · architecture=two concatenated VGGs · subject-split=154 train, 22 validation, 44 testA Trainable Multiplication Layer for Auto-correlation and Co-occurrence Extraction
Source quote
L479: Concatenated two VGGs │ Flair and T1c │ 94.47
2019CycleGAN baselineMSE ↓674.40split: test · direction=Flair-to-T1Harmonic Unpaired Image-to-image Translation
Source quote
L264: MAE \downarrow │ MSE \downarrow │ PSNR \uparrow │ SSIM \uparrow │ MAE \downarrow │ MSE \downarrow │ PSNR \uparrow │ SSIM \uparrow CycleGAN │ 10.47 │ 674.40 │ 22.35 │ 0.80 │ 11.81 │ 1026.19 │ 18.73 │ 0.74
2019CycleGAN baselineMSE ↓1026.19split: test · direction=T1-to-FlairHarmonic Unpaired Image-to-image Translation
Source quote
L264: MAE \downarrow │ MSE \downarrow │ PSNR \uparrow │ SSIM \uparrow │ MAE \downarrow │ MSE \downarrow │ PSNR \uparrow │ SSIM \uparrow CycleGAN │ 10.47 │ 674.40 │ 22.35 │ 0.80 │ 11.81 │ 1026.19 │ 18.73 │ 0.74
2018SynNet (Joint Loss) proposedSSIM0.86split: test · loss=joint · input-modality=T1 · target-modality=T2SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image Synthesis
Source quote
L198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex]
2018SynNet (Joint Loss) proposedSSIM0.70split: test · loss=joint · input-modality=T2 · target-modality=T1SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image Synthesis
Source quote
L198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex]
2018SynNet (Weighted L₂ loss) ablationSSIM0.77split: test · loss=weighted-L2 · input-modality=T1 · target-modality=T2SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image Synthesis
Source quote
L197: Weighted L-2 │ T1 │ T2 │ 21.80 │ 0.77 │ T2 │ T1 │ 20.61 │ 0.69
2018SynNet (Weighted L₂ loss) ablationSSIM0.69split: test · loss=weighted-L2 · input-modality=T2 · target-modality=T1SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image Synthesis
Source quote
L197: Weighted L-2 │ T1 │ T2 │ 21.80 │ 0.77 │ T2 │ T1 │ 20.61 │ 0.69
2016HeMIS proposedDSC, Complete tumor category71.26%split: test · modalities=FLAIR only · missing-modalities=T1W, T1C, T2WHeMIS: Hetero-Modal Image Segmentation
Source quote
L351: \bullet │ \circ │ \circ │ \circ │ 34.48 │ 9.77 │ 38.46 │ 71.26 │ 72.30 │ 63.81 │ 37.45 │ 0.00 │ 34.26 │ 5.57 │ 6.25 │ 15.90
2016MLP imputation baselineDSC, Complete tumor category63.81%split: test · imputation=MLP · modalities=FLAIR only · missing-modalities=T1W, T1C, T2WHeMIS: Hetero-Modal Image Segmentation
Source quote
L351: \bullet │ \circ │ \circ │ \circ │ 34.48 │ 9.77 │ 38.46 │ 71.26 │ 72.30 │ 63.81 │ 37.45 │ 0.00 │ 34.26 │ 5.57 │ 6.25 │ 15.90