BraTS
93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ReMIC SOTA frontier | 0.9618 | 2021-01-01 | target=T1 · Image-completion result from the extended results table; quantitative test generation… | Multi-Domain Image Completion for Random Missing Input DataSource quote{ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2 | TransCSCN | 0.943 | 2022-01-01 | modality-direction=T1w-to-FLAIR · Table 1 average; 45 BraTS test cases; bias-field-corrected scans; unsupervised method… | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quote0.943 |
| 3 | MRNet | 0.9411 | 2024-12-01 | plane=axial · direction=FLAIR-to-T2 · Paired FLAIR-to-T2 evaluation on axial cross-sections; test set comprises 127 persons… | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteOURS │ 31.2852 │ 0.9411 │ \checkmark |
| 4 | SynNet (Joint Loss) SOTA frontier (+3 variants) | 0.86 | 2018-06-01 | loss=joint · input-modality=T1 · target-modality=T2 · T1 input and T2 output; BRATS dataset description reports 96 training and 24 testing … | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteJoint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 5 | SyMOT-Flow | 0.83 | 2023-08-01 | encoding=VQ-VAE-2 · subgroup=T2 · BraTS MRI slices; 1,000 training and 251 test images per modality; VQ-VAE-2 feature-s… | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteOurs │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
Metricdice (30)psnr (27)ssim (19)dsc (11)inconsistency with radiologist evaluations lower (6)iou (5)
Regimefine-tuned (9)unsupervised (8)unsupervised-domain-adaptation (6)semi-supervised (5)weakly-supervised (4)few-shot (4)
Showing 118 of 118 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | JiT-L/16 (direct IN transfer) proposed | gFID | 40.17 | split: test · in-initialized-training | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL884: 40.17 |
| 2026 | JiT-B/16 (IN initialization) proposed | gFID | 31.73 | split: test · fine-tuned | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL865: 31.73 |
| 2026 | MPFlow (full) proposed non-standard slice | Dice (\uparrow) | 0.740 | 0-shot · backbone=Swin-UNet · input-modality=FLAIR · sampling-steps=100 · evaluation-model=Swin-UNet | MPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI ReconstructionSource quoteL290: MPFlow (full) │ \textbf{4.85× 10 (-4)} │ 0.740 |
| 2026 | VariaFlow proposed | AUROC | 0.78 | split: test · cross-domain | VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly DetectionSource quoteL34: the highest AUROC (0.94, 0.80, 0.78) on each and the high- |
| 2026 | SynerMedGen (Stage I+II) proposed | SSIM | 90.62 | modality=FL.→T1 | SynerMedGen: Synergizing Medical Multimodal Understanding with Generation via Task AlignmentSource quoteL733: 90.62+9.28 |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposed | Mean PSNR | 27.3 dB | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposed | Mean SSIM | 0.95 | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | MRIComp4Flow WFM trained on JPEG2000-compressed data at 200:1 proposed | PSNR | 24.65 dB | split: val · modality=T1n · compression=JPEG2000 200:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL125: 200 │ 23.25 │ 24.65 │ 23.07 │ 22.63 │ 0.879 │ 0.968 │ 0.937 │ 0.902 |
| 2026 | MRIComp4Flow WFM trained on JPEG2000-compressed data at 400:1 proposed | PSNR | 20.94 dB | split: val · modality=T1n · compression=JPEG2000 400:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL126: 400 │ 19.30 │ 20.94 │ 21.29 │ 17.18 │ 0.852 │ 0.829 │ 0.814 │ 0.750 |
| 2026 | Transfer-Aware proposed | Dice | 55.1% | fine-tuned · modality=Brain T1 | Knowledge Transfer Scaling Laws for 3D Medical ImagingSource quoteL468: The same trend holds for dense prediction. On AMOS, Transfer-Aware achieves 83.1 Dice on abdominal CT and 69.4 Dice on abdominal MRI, outperforming Data-Proportional by 1.5 and 0.6 points, respectively. The gains are larger on brain and head-and-neck tasks. On BraTS, Transfer-Aware improves over Data-Proportional from 50.4 to 55.1 Dice on Brain T1 and from 61.4 to 65.4 Dice on Brain T2. On head-and-neck CT segmentation, Transfer-Aware improves HECKTOR from 67.8 to 71.1 Dice and BHSD from 57.2 to 61.2 Dice. Across all six segmentation tasks, Transfer-Aware yields the best performance among the compared pretraining strategies. |
| 2025 | MAD-AD proposed | Modality (Max Dice) | 70.3 | setting=S2 · modalities=FLAIR, T1CE, T2-w, T1-w · aggregation=average | MAD-AD: Masked Diffusion for Unsupervised Brain Anomaly DetectionSource quoteL178: MAD-AD (Ours) │ 76.2\worse{-4.0} │ 68.5\imp{+6.8} │ 73.2\imp{+2.0} │ 63.4\imp{+4.9} │ 70.3\imp{+2.4} |
| 2025 | fastWDM3D (T=2) proposed | AST (average sampling time per volume) | 1.81 s | split: test · sampling-steps=2 | fastWDM3D: Fast and Accurate 3D Healthy Tissue InpaintingSource quoteL134: Ours (fastWDM3D (T=2)) │ 0.86 ± 0.12 │ 0.0079 ± 0.0063 │ 22.26 ± 3.97 │ \hphantom{0}\SI{1.81}{\second} |
| 2025 | UniFS proposed | PSNR improvement over FSMNet | 1.06dB | acceleration=4× · undersampling-patterns=3 | UniFS: Unified Multi-Contrast MRI Reconstruction via Frequency-Spatial FusionSource quoteL176: As shown in Table \ref{tab1}, UniFS consistently outperforms all competing methods in terms of image reconstruction quality. Compared with the current leading method FSMNet \cite{FSMNet}, which also incorporates frequency feature fusion, UniFS achieves significant PSNR improvements of 1.06dB and 2.00dB under 4× acceleration on the BraTs and HCP datasets. These results highlight the effectiveness of the enhanced frequency fusion design within the CMF module. Furthermore, Fig. \ref{fig2} shows reconstructed images and corresponding error maps from different methods. The zoomed-in views reveal that UniFS achieves more accurate texture recovery, while the noticeably smaller error maps further confirm its superior reconstruction fidelity. |
| 2025 | IterMask3D proposed | DSC | 69.7 | split: test · test-time-refinement · tuning=test-set, 3 standard deviations · modality=FLAIR · training-data=cognitively normal ADNI/OASIS · dimensionality=3D | IterMask3D: Unsupervised Anomaly Detection and Segmentation with Test-Time Iterative Mask Refinement in 3D Brain MRSource quoteL534: \multicolumn{1}{l|}{IterMask3D} │ 69.7 │ 99.2 │ 72.7 │ 71.1 │ 56.7 │ 32.2 │ 5.1 |
| 2025 | OAIMS proposed | Dice | 74.6 | clicks=10 · modality=T1 · incorrect-clicks=40% | You Point, I Learn: Online Adaptation of Interactive Segmentation Models for Handling Distribution Shifts in Medical ImagingSource quoteL668: OAIMS │ 67.8 │ 71.8 │ 74.6 |
| 2025 | MTMed3D (Avg.) proposed | [email protected]:0.5 | 0.9082 | aggregation=average | MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical ImagingSource quoteL232: 0.9082 │ 0.9357 │ 0.8955 |
| 2025 | MTMed3D (Avg.) proposed | [email protected]:0.5 | 0.9357 | aggregation=average | MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical ImagingSource quoteL232: 0.9082 │ 0.9357 │ 0.8955 |
| 2025 | AugPaint proposed | Dice | 35.19% | semi-supervised · analysis=mask-flipping · labeled-cases=1 | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quoteL333: AugPaint │ 35.19 │ 62.33 │ 41.85 │ 38.43 |
| 2025 | SIPL proposed | DSC | 83.0% | split: test · regions=whole tumor, enhancing tumor, tumor core · train-val-test-split=80:5:15 | Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype LearningSource quoteL197: SIPL (ours) │ 83.0 │ -- |
| 2025 | Ours-PL proposed | Dice (%) average | 59.37% | unsupervised-domain-adaptation · source_domain=T2 · target_domain=Flair | Bézier Meets Diffusion: Robust Generation Across Domains for Medical Image SegmentationSource quoteL430: Ours-PL │ 71.70 │ \bf 65.42 │ \bf 41.00 │ \bf 59.37 │ 22.59 │ 19.98 │ 25.89 │ 22.82 |
| 2025 | Ours-AD proposed | 95HD average | 18.81 | unsupervised-domain-adaptation · source_domain=T2 · target_domain=Flair | Bézier Meets Diffusion: Robust Generation Across Domains for Medical Image SegmentationSource quoteL428: Ours-AD │ 73.74 │ 62.30 │ 39.80 │ 58.61 │ 12.44 │ \bf 18.58 │ \bf 25.42 │ \bf 18.81 |
| 2025 | VIViT+SSL proposed | Mean Dice | 0.883 | split: test · resolution=128×128×128 | VIViT: Variable-Input Vision Transformer Framework for 3D MR Image SegmentationSource quoteL130: VIViT+SSL │ 0.624 │ 0.871 │ 0.893 │ 0.884 │ 0.883 |
| 2025 | Expert-guided explainable few-shot learning (guided model) proposed | Accuracy | 83.61% | few-shot · epoch=7 · episodes=60 · explanation-weight-alpha=0.10 | Expert-Guided Explainable Few-Shot Learning for Medical Image DiagnosisSource quoteL107: 7 │ 60 │ 83.61 │ 77.09 |
| 2025 | BOGC-MML proposed | Top-1 accuracy | 77.86% | available-modality=T1c · missing-modalities=Fl, T1, T2 | Multi-Modal Learning with Bayesian-Oriented Gradient CalibrationSource quoteL343: 62.02 │ 67.07 │ 72.60 │ 75.65 │ 77.86 |
| 2025 | NAGL proposed | average AUROC | 89.5% | few-shot · reference_samples=N^2+A^1 | Normal-Abnormal Guided Generalist Anomaly DetectionSource quoteL228: \paragraph{Generalization.} Our method exhibits superior generalization capabilities compared to ResAD across multiple datasets. On MVTecAD, under the N^1+A^1 setting, our approach achieves 95.7% image F1-max and 58.9% pixel F1-max, outperforming ResAD by 4.5 and 10.7 percentage points, respectively. Similarly, on VisA, we attain 85.4% image F1-max and 41.8% pixel F1-max, exceeding ResAD by 4.1 and 4.0 percentage points. Furthermore, as shown in Tab.~\ref{tab:exp_medical}, our method demonstrates superior cross-domain generalization, achieving 89.5% average AUROC on the BraTS medical dataset with just two normal and one abnormal sample, a 10.6 percentage point improvement over ResAD (78.9% with N^2 setting). Notably, across all other experimental settings, our method consistently outperforms existing approaches in both anomaly detection and segmentation. These results clearly demonstrate the effectiveness of our method in generalist AD. |
| 2025 | CADD proposed non-standard slice | Average maximum Dice | 0.3548 | fine-tuned · modality=FLAIR · fine-tuning-data=AIBL · clinical-covariates=none | CADD: Context aware disease deviations via restoration of brain images using normative conditional diffusion modelsSource quoteL343: Dice (\uparrow) │ 0.3386 │ 0.2619 │ 0.3548 |
| 2025 | Causal-SAM-LLM proposed | Dice | 75.7% | fine-tuned · evaluation=single-source-domain-generalization · aggregation=three random seeds · training_dataset=BTCV CT | Causal-SAM-LLM: Large Language Models as Causal Reasoners for Robust Medical SegmentationSource quoteL173: Causal-SAM-LLM │ 52.8 │ 83.5 │ 23.4 │ \bfseries 79.5 │ \bfseries 18.9 │ \bfseries 75.7 │ \bfseries 17.6 |
| 2025 | Causal-SAM-LLM proposed | HD95 | 17.6 mm | fine-tuned · evaluation=single-source-domain-generalization · aggregation=three random seeds · training_dataset=BTCV CT | Causal-SAM-LLM: Large Language Models as Causal Reasoners for Robust Medical SegmentationSource quoteL173: Causal-SAM-LLM │ 52.8 │ 83.5 │ 23.4 │ \bfseries 79.5 │ \bfseries 18.9 │ \bfseries 75.7 │ \bfseries 17.6 |
| 2025 | FgC2F-UDiff (Our method) proposed | PSNR | 26.34 dB | synthesis=many-to-one · target-modality=T1ce · input-modalities=T1,T2 | FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI SynthesisSource quoteL312: \multirow{2}{*}{Our method} │ 26.34 │ 0.894 │ 17.45 │ 20.85 │ 27.19 │ 0.937 │ 16.14 │ 18.74 |
| 2025 | SpectMamba proposed | mAP | 75.34 | split: test · epochs=200 · pretraining=none | SpectMamba: Integrating Frequency and State Space Models for Enhanced Medical Image DetectionSource quoteL275: {SpectMamba} │ 89.83 │ 78.64 │ 57.54 │ 75.34 │ 95.35 │ 85.64 │ 68.24 │ 83.08 |
| 2024 | QCResUNet proposed | Pearson r (DSC prediction) | 0.968 | split: test · metric-target=DSC · prediction-level=subject-level · segmentation-models=nnUNet, nnFormer | QCResUNet: Joint subject-level and voxel-level segmentation quality predictionSource quoteL279: Specifically, on the BraTS internal testing set with segmentations generated by nnUNet and nnFormer, the proposed method achieved a small mean MAE of 0.056 and 0.064 for NSD and DSC prediction, respectively. The predicted NSD and DSC also showed a strong correlation with the corresponding ground truth, achieving Pearson r values of 0.958 and 0.968, respectively. Importantly, the proposed method generalized well for segmentation produced by different methods (i.e., DeepMedic), which had not been used during training, achieving an average MAE of 0.074 and 0.062 for NSD and DSC prediction. Similarly, the predicted NSD and DSC showed a strong correlation with their ground truth with Pearson r values of 0.937 and 0.962, respectively. |
| 2024 | Domain-Game proposed | Dice | 65.05 | targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1Gd | Domain GameSource quoteL263: \ \ \textBF{65.05 \down{13.42}} \ \ │ \ \textBF{59.53 \down{15.95}} |
| 2024 | Domain-Game proposed | Jaccard | 59.53 | targets=BraTS-Africa; BraTS-Pediatrics · sequence=T1Gd | Domain GameSource quoteL263: \ \ \textBF{65.05 \down{13.42}} \ \ │ \ \textBF{59.53 \down{15.95}} |
| 2024 | McCaD proposed | Dice score | 0.8004 | split: test · retained-contrasts=T1w, FLAIR · synthetic-contrast=T2w · segmentation-target=whole-tumor | McCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI SynthesisSource quoteL210: AttGAN │ DDPM │ Hi-Net │ MM-GAN │ McCaD │ Complete T2w │ 0.7692 │ 0.7987 │ 0.7921 │ 0.7991 │ 0.8004 │ 0.8188 T2w + FLAIR │ 0.6974 │ 0.6262 │ 0.7401 │ 0.7449 │ 0.7602 │ 0.8188 |
| 2024 | HF-GAN proposed | PSNR | 30.27 | aggregation=average across missing-sequence scenarios · architecture=2D slice-based | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | HF-GAN proposed | SSIM | 0.9393 | aggregation=average across missing-sequence scenarios · architecture=2D slice-based | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | HF-GAN (ours) imputation proposed | Dice (ET) | 0.6438 | split: test · evaluation=after imputation · architecture=2D slice-based · test-subjects=85 · segmentation-region=ET | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL284: \multicolumn{4}{c|}{Average} │ 0.6196* (0.3202) │ 0.5130* (0.3041) │ 0.4957* (0.3598) │ 0.8436* (0.1279) │ 0.7247* (0.1728) │ 0.6139* (0.3619) │ 0.8405* (0.1356) │ 0.7178* (0.1766) │ 0.6313* (0.3446) │ 0.8632 (0.1033) │ 0.7488 (0.1588) │ 0.6174* (0.3743) │ 0.8618 (0.1071) │ 0.7472 (0.1625) │ 0.6438 (0.3397) |
| 2024 | MRNet proposed | PSNR | 31.2852 | split: test · plane=axial · direction=FLAIR-to-T2 | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteL269: OURS │ 31.2852 │ 0.9411 │ \checkmark |
| 2024 | MRNet proposed | SSIM | 0.9411 | split: test · plane=axial · direction=FLAIR-to-T2 | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteL269: OURS │ 31.2852 │ 0.9411 │ \checkmark |
| 2024 | Ours (GAN-based semantic segmentation model) proposed | Pixel Accuracy | 0.5821 | Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state… | Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic SegmentationSource quoteL140: Pixel Accuracy and Recall of these models, the performance of each model in the brain tumor segmentation task can be more comprehensively evaluated. First of all, from the perspective of pixel accuracy (Pixel Accuracy), our model performs best, reaching 0.5821, which is significantly improved compared to other models. Specifically, the pixel accuracy of FCNs is |
| 2024 | Ours (GAN-based semantic segmentation model) proposed | Recall | 0.5523 | Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state… | Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic SegmentationSource quoteL143: Secondly, from the perspective of recall index, our model also performed well, reaching 0.5523, which is better than all other comparison models. The recall rate of FCNs is 0.5231, |
| 2024 | Ours (GAN-based semantic segmentation model) proposed | Dice | 0.4433 | Brain-tumor semantic segmentation on BRATS; split and aggregation details are not state… | Adversarial Neural Networks in Medical Imaging Advancements and Challenges in Semantic SegmentationSource quoteL175: From the perspective of Dice coefficient, our model also performs well, reaching 0.4433, which is higher than all other models. The Dice coefficient of FCNs is 0.4119, SegNet is |
| 2024 | TrIND (per-sample INR) proposed non-standard slice | Rel. Error | 0.039% | Table 2: relative percentage error between reconstructed signal and ground truth; repre… | TrIND: Representing Anatomical Trees by Denoising Diffusion of Implicit Neural FieldsSource quoteL225: 0.039 |
| 2024 | TrIND (per-sample INR) proposed | INR Size | 0.753 MB | Table 2 reports the INR size for this modality alongside input size; the table evaluate… | TrIND: Representing Anatomical Trees by Denoising Diffusion of Implicit Neural FieldsSource quoteL227: 0.753↓×90.45 |
| 2024 | VerSe (Mode-3) proposed | Dice(10) | 94.492 | evaluation=out-of-distribution · interaction=10-click | VerSe: Integrating Multiple Queries as Prompts for Versatile Cardiac MRI SegmentationSource quoteL270: \texttt{VerSe} (Mode-3) │ 69.516 │ 80.631 │ 11.787 │ 94.492 │ 96.811 │ 2.777 |
| 2024 | VerSe (Mode-3) proposed | Dice(20) | 96.811 | evaluation=out-of-distribution · interaction=20-click | VerSe: Integrating Multiple Queries as Prompts for Versatile Cardiac MRI SegmentationSource quoteL270: \texttt{VerSe} (Mode-3) │ 69.516 │ 80.631 │ 11.787 │ 94.492 │ 96.811 │ 2.777 |
| 2024 | HiDiff proposed non-standard slice | Average Dice | 51.77 | split: test · subset=small tumors; pixel-wise tumor size <100 | HiDiff: Hybrid Diffusion Framework for Medical Image SegmentationSource quoteL506: {{HiDiff}\xspace (ours)} │ 51.77 │ 8.76(20.13%) │ 59.00 │ 47.30 │ 49.00 |
| 2024 | PrimGeoSeg (SwinUNETR; FDSL pre-training) proposed | Avg. score | 90.3 | fine-tuned · backbone=SwinUNETR · pretraining=FDSL | Primitive Geometry Segment Pre-training for 3D Medical Image SegmentationSource quoteL305: PrimGeoSeg │ FDSL │ 88.7 │ 85.6 │ 91.8 │ 88.9 │ 90.3 │ 87.0 │ 92.9 │ 91.0 \\[0.8pt] |
| 2024 | MultiUNet (drop mods) proposed | Dice | 0.614 | input=single-modality · evaluation=held-out-unseen-pathology · modalities=Flair-or-T1 | Feasibility and benefits of joint learning from MRI databases with different brain diseases and modalities for segmentationSource quoteL165: MultiUNet (drop mods) │ Flair or T1 │ 0.614 │ 0.454 │ 0.324 │ 0.241 │ 0.540 |
| 2024 | NACL proposed | DSC | 0.850 | backbone=UNet · training=2D slices · evaluation=3D volumes | Neighbor-aware calibration of segmentation networks with penalty-based constraintsSource quoteL238: Mean │ 0.789 │ 6.96 │ \und{0.848} │ 9.00 │ 0.808 │ 8.71 │ 0.820 │ 7.78 │ 0.801 │ 8.44 │ 0.838 │ 7.94 │ 0.850 │ 5.78 |
| 2024 | TrIND (INR representation) proposed non-standard slice | Rel. Error | 0.039% | INR reconstruction; relative percentage error between the reconstructed signal and grou… | Representing Anatomical Trees by Denoising Diffusion of Implicit Neural FieldsSource quoteL201: BraTS~\cite{menze2014multimodal} │ 0.039 │ 68.11-± 0.00 │ 0.753-\downarrow ×90.45 |
| 2024 | Kaggle duplicate audit proposed | Duplicates | 383 duplicates | platform=Kaggle · data-collected=October 2024 | Copycats: the many lives of a publicly available medical imaging datasetSource quoteL188: BraTS~\cite{menze2014multimodal} │ 383 │ \phantom{0}51.5 GB\textsuperscript{\mathsection} │ \phantom{00}7.3 TB │ 30.0 │ 9 │ 92.4 |
| 2024 | X-Diffusion (1-slice input) proposed | Test 3D PSNR | 23.10 | split: test · sequence=FLAIR T2 · input-slices=1 | X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion ModelsSource quoteL131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01 |
| 2023 | Proposed equality-constraint linear-penalty method on logits (λ=0.1) proposed | ECE | 0.112 | class=foreground · lambda=0.1 · training=2D slices · evaluation=3D volumes | Trust your neighbours: Penalty-based constraints for model calibrationSource quoteL178: Ours (\lambda=0.1) │ 0.868 │ 4.88 │ 0.033 │ 0.031 │ 0.854 │ 2.55 │ 0.048 │ 0.061 │ 0.850 │ 5.78 │ 0.112 │ 0.097 |
| 2023 | coreset lifelong learning model (10x compression) proposed | mean pixel error distance | 12.93 pixel | compression=10x | Selective experience replay compression using coresets for lifelong deep reinforcement learning in medical imagingSource quoteL7: We evaluated the coreset lifelong deep reinforcement learning technique on the brain tumor segmentation (BRATS) dataset for the task of ventricle localization and on the whole-body MRI for localization of left knee cap, left kidney, right trochanter, left lung, and spleen. The coreset lifelong learning models trained on a sequence of 10 different brain MR imaging environments demonstrated excellent performance localizing the ventricle with a mean pixel error distance of 12.93, 13.46, 17.75, and 18.55 for the compression ratios of 10x, 20x, 30x, and 40x, respectively. In comparison, the conventional lifelong learning model localized the ventricle with a mean pixel distance of 10.87. Similarly, the coreset lifelong learning models trained on whole-body MRI demonstrated no significant difference (p=0.28) between the 10x compressed coreset lifelong learning models and conventional lifelong learning models for all the landmarks. The mean pixel distance for the 10x compressed models across all the landmarks was 25.30, compared to 19.24 for the conventional lifelong learning models. Our results demonstrate that the potential of the coreset-based ERB compression method for compressing experiences without a significant drop in performance. |
| 2023 | coreset lifelong learning model (40x compression) proposed | mean pixel error distance | 18.55 pixel | compression=40x | Selective experience replay compression using coresets for lifelong deep reinforcement learning in medical imagingSource quoteL7: We evaluated the coreset lifelong deep reinforcement learning technique on the brain tumor segmentation (BRATS) dataset for the task of ventricle localization and on the whole-body MRI for localization of left knee cap, left kidney, right trochanter, left lung, and spleen. The coreset lifelong learning models trained on a sequence of 10 different brain MR imaging environments demonstrated excellent performance localizing the ventricle with a mean pixel error distance of 12.93, 13.46, 17.75, and 18.55 for the compression ratios of 10x, 20x, 30x, and 40x, respectively. In comparison, the conventional lifelong learning model localized the ventricle with a mean pixel distance of 10.87. Similarly, the coreset lifelong learning models trained on whole-body MRI demonstrated no significant difference (p=0.28) between the 10x compressed coreset lifelong learning models and conventional lifelong learning models for all the landmarks. The mean pixel distance for the 10x compressed models across all the landmarks was 25.30, compared to 19.24 for the conventional lifelong learning models. Our results demonstrate that the potential of the coreset-based ERB compression method for compressing experiences without a significant drop in performance. |
| 2023 | CG-CDM proposed | infer time | 2.78s | weakly-supervised · Q=400 · R=10 · s=10 · τ=0.95 · denoising-iterations=10 | Conditional Diffusion Models for Weakly Supervised Medical Image SegmentationSource quoteL186: CG-CDM │ 0.563±0.023 │ 0.450±0.012 │ 19.2±3.2 │ 2.78s |
| 2023 | MMCCD proposed | DICE | 0.6092 | unsupervised · input-modality=FLAIR | Modality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRISource quoteL191: MMCCD │ 0.6092 │ 0.9409 │ 0.4682 │ 0.6505 │ 0.6336 │ 6.1171 |
| 2023 | MMCCD proposed | Jac | 0.4682 | unsupervised · input-modality=FLAIR | Modality Cycles with Masked Conditional Diffusion for Unsupervised Anomaly Segmentation in MRISource quoteL191: MMCCD │ 0.6092 │ 0.9409 │ 0.4682 │ 0.6505 │ 0.6336 │ 6.1171 |
| 2023 | Ensemble ResNet-34x50 `and' proposed | Best AVG DSC | 70.3 | weakly-supervised · backbone=ResNet-34 + ResNet-50 ensemble · resolution=34x50 · supervision=image-level labels | Exploring Weakly Supervised Semantic Segmentation Ensembles for Medical Imaging SystemsSource quoteL232: Ensemble ResNet-34x50 `and' │ 70.3 │ 54.2 |
| 2023 | SyMOT-Flow proposed | SSIM ↑ | 0.83 | split: test · encoding=VQ-VAE-2 · subgroup=T2 | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteL529: Ours │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
| 2023 | ViT-AE++ proposed | AUC | 0.767 | backbone=ViT-AE · dimension=3D · training-samples-per-fold=260 | ViT-AE++: Improving Vision Transformer Autoencoder for Self-supervised Medical Image RepresentationsSource quoteL146: ViT-AE++(ours) │ {0.767} │ 0.846 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 30.68 dB | split: test · scale=8x out-of-scale · target-modality=T2 · reference-modality=T1 | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL576: 30.68 |
| 2023 | LKA-E proposed | HD95 (WT) | 2.449 | split: test | Large-kernel Attention for Efficient and Robust Brain Lesion SegmentationSource quoteL147: LKA-E (Ours) │ \multicolumn{1}{l|}{0.888} │ \multicolumn{1}{l|}{0.932} │ 0.939 │ \multicolumn{1}{l|}{1.414} │ \multicolumn{1}{l|}{2.000} │ 2.449^* |
| 2023 | Chebyshev confidence guided SFDA framework (full configuration) proposed | Dice | 77.10 | adaptation=source-free domain adaptation · evaluation=average over scenarios | A Chebyshev Confidence Guided Source-Free Domain Adaptation Framework for Medical Image SegmentationSource quoteL316: \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 89.28 │ 6.52 │ 77.10 │ 10.60 |
| 2023 | Chebyshev confidence guided SFDA framework (full configuration) proposed | ASD | 10.60 | adaptation=source-free domain adaptation · evaluation=average over scenarios | A Chebyshev Confidence Guided Source-Free Domain Adaptation Framework for Medical Image SegmentationSource quoteL316: \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 89.28 │ 6.52 │ 77.10 │ 10.60 |
| 2023 | GL-MAE (ViT-T; listed as Ours) proposed | Avg Dice score | 78.31% | backbone=ViT-T | Advancing Volumetric Medical Image Segmentation via Global-Local Masked AutoencoderSource quoteL234: Ours │ ViT-T │ 83.00 │ 91.15 │ 60.46 │ 78.31 |
| 2023 | K-CROSS proposed non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.1851 | subset=1,200 images per generator · generator=CycleGAN · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147} |
| 2023 | K-CROSS proposed non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.2246 | subset=1,200 images per generator · generator=MUNIT · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147} |
| 2023 | K-CROSS proposed non-standard slice | Inconsistency with radiologist evaluations (lower is better) | 0.2147 | subset=1,200 images per generator · generator=UNIT · evaluation-study=NIRPS | K-Space-Aware Cross-Modality Score for Synthesized Neuroimage Quality AssessmentSource quoteL374: K-CROSS │ \textcolor{red}{0.2878} │ \textcolor{red}{0.1851} │ \textcolor{red}{0.1650} │ \textcolor{red}{0.2246} │ \textcolor{red}{0.2123} │ \textcolor{red}{0.2147} |
| 2023 | ProM (2D) proposed | Dice | 0.706 | acceleration=x32 · mask-variant=2D | Constrained Probabilistic Mask Learning for Task-specific Undersampled MRI ReconstructionSource quoteL226: \multirow{2}{*}{\texttt{x32}} │ Dice │ \uparrow \,\, │ 0.644 │ 0.399 │ 0.592 │ 0.587 │ 0.727 │ 0.580 │ 0.315 │ 0.537 │ 0.483 │ 0.706 |
| 2023 | ProM (2D) proposed | IoU | 0.608 | acceleration=x32 · mask-variant=2D | Constrained Probabilistic Mask Learning for Task-specific Undersampled MRI ReconstructionSource quoteL227: IoU │ \uparrow \,\, │ 0.517 │ 0.301 │ 0.466 │ 0.460 │ 0.606 │ 0.472 │ 0.226 │ 0.428 │ 0.374 │ 0.608 |
| 2023 | Ours ensemble (1/4 train/validation task split) proposed | Pixel-wise AP (average precision) | 76.2 | split: test · ensemble=yes · modality=brain MRI · task-split=1/4 train/validation | Many tasks make light work: Learning to localise medical anomalies from multiple synthetic tasksSource quoteL229: \multicolumn{3}{l}{Ours} │ 87.6/92.2 │ 62.0/84.6 │ 76.2/99.1 │ 45.9/97.9 │ 78.4/76.6 │ 71.2/81.1 │ 21.1/75.6 │ 21.4/81.2 |
| 2023 | E2ENet (DSFF enabled; restricted depth-shift enabled) proposed | mDice | 74.5% | split: val · 5-fold-cross-validation · DSFF=enabled · kernel-size=1×3×3 · restricted-depth-shift=enabled | E2ENet: Dynamic Sparse Feature Fusion for Accurate and Efficient 3D Medical Image SegmentationSource quoteL349: \CheckmarkBold │ \CheckmarkBold │ (1×3×3) │ 81.2 │ 62.7 │ 79.5 │ 74.5 │ 11.24 │ 1067.06 |
| 2022 | DDPM (f=4) (b) [Ours] proposed | theoretically best possible DICE-score (\lceil DICE \rceil) | 0.469 | unsupervised · model-variant=DDPM (f=4) (b) | Fast Unsupervised Brain Anomaly Detection and Segmentation with Diffusion ModelsSource quoteL91: DDPM (f=4) (b) [Ours] │ 0.208^\dagger │ 0.204 │ 0.469^\dagger │ 0.272 |
| 2022 | UNETR+MAE proposed | average DSC | 78.91% | self-pretraining · backbone=UNETR · mask-ratio=12.5% | Self Pre-Training with Masked Autoencoders for Medical Image Classification and SegmentationSource quoteL124: UNETR+MAE │ 78.91 │ 7.22 │ 90.84 │ 7.04 │ 63.88 │ 7.15 │ 82.00 │ 7.13 |
| 2022 | PseudoClick (C+L, HRNet32) proposed | mIoU@3 | 64.0% | Cross-domain human evaluation; trained on C+L and applied without finetuning; 3 human c… | PseudoClick: Interactive Image Segmentation with Click ImitationSource quoteL230: Ours │ C+L │ N/A │ HRNet32 │ 64.0 │ 80.1 |
| 2022 | SimpleClick ViT-H proposed | mIoU@10 | 88.98 | clicks=10 · backbone=ViT-H · finetuning=none | SimpleClick: Interactive Image Segmentation with Simple Vision TransformersSource quoteL207: \twonotes Ours-ViT-H │ 94.08 │ 88.98 / 91.00 │ 77.50 / 80.10 |
| 2022 | DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposed | MAE | 0.51 stars | split: test · backbone=DenseNet121 · optimizer=Ranger21 | Deep Quality Estimation: Creating Surrogate Models for Human Quality RatingsSource quoteL119: 0.51 |
| 2022 | DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposed | RMSE | 0.80 stars | split: test · backbone=DenseNet121 · optimizer=Ranger21 | Deep Quality Estimation: Creating Surrogate Models for Human Quality RatingsSource quoteL120: 0.80 |
| 2022 | DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposed | Pearson r | 0.66 | split: test · backbone=DenseNet121 · optimizer=Ranger21 | Deep Quality Estimation: Creating Surrogate Models for Human Quality RatingsSource quoteL121: 0.66 |
| 2022 | TransCSCN proposed | PSNR (dB) | 39.12 dB | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL439: 39.12 |
| 2022 | TransCSCN proposed | SSIM | 0.943 | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL448: 0.943 |
| 2022 | TransCSCN proposed | Dice (in %) | 85.68% | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL457: 85.68 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 41.49 | split: test · orientation=axial · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 37.36 | split: test · orientation=coronal · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 37.18 | split: test · orientation=sagittal · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2022 | DistGP-Seg proposed | DICE (FPR=0.5) | 0.571 | threshold=derived from UKBB · evaluation=voxel-level tumor overlap · metric-setting=FPR=0.5 | Distributional Gaussian Processes Layers for Out-of-Distribution DetectionSource quoteL866: DistGP-Seg (ours) │ 0.512 │ 0.571 │ 0.532 │ 0.489 |
| 2022 | UNETR++ proposed | GPU inference time (GPU T.) | 62.4 ms | hardware=Quadro RTX 6000 24 GB · resolution=128x128 · input-resolution=128×128×128 | UNETR++: Delving Into Efficient and Accurate 3D Medical Image SegmentationSource quoteL244: UNETR++ │ 42.6 │ 70.1 │ 2.4 │ 62.4 │ 1497.7 │ 82.8 |
| 2021 | IGS-optimized undersampling pattern (table label “Ours”) proposed | F1-score | 0.877 | split: val · loss=Soft Hinge · backbone=ResNet-18 · validation=5-fold cross-validation · acceleration=×4 | Optimal MRI Undersampling Patterns for Ultimate Benefit of Medical Vision TasksSource quoteL270: Soft Hinge │ 0.834 │ 0.848 │ 0.877 |
| 2021 | Asymmetric combination proposed | DSC | 62.4 | backbone=DeepMedic · training-data=5% · post-processing=none | Analyzing Overfitting under Class Imbalance in Neural Networks for Image SegmentationSource quoteL872: Asymmetric combination │ 62.4 │ 64.7 │ 71.5 │ 27.8 │ 71.4 │ 73.8 │ 74.3 │ 20.8 │ 71.9 │ 74.1 │ 79.2 │ 20.7 │ 72.9 │ 77.0 │ 77.8 │ 19.0 |
| 2021 | MBConv-Base proposed | Dice score | 0.7513 | split: hold-out · channels=30, 60, 120, 180, 240 · resolution=256x256x160 · expand-ratio=2 · memory-budget=14GB | Memory Efficient 3D U-Net with Reversible Mobile Inverted Bottlenecks for Brain Tumor SegmentationSource quoteL81: As seen in Table \ref{tab1}, our best MBConv reversible architecture was found to be the MBConv-Base variant which achieves a mean Dice score (averaged over all classes) above 0.7317 on hold out set after 50 epochs of training and Dice score of 0.7513 after convergence. The rate of convergence is faster than the baseline which only reaches a Dice score of 0.7184 after 50 epochs of training although the final score after convergence is slightly higher (0.7513). In Figure \ref{fig1}, a sample segmentation for an example from the the training set and an example from the holdout set indicate a close match between the prediction and the ground truth. |
| 2021 | Trad.+3DSiam+SE proposed | Specificity | 0.711 | split: val · validation=stratified cross-validation · label_fraction=full | Imbalance-Aware Self-supervised Learning for 3D Radiomic RepresentationsSource quoteL139: Trad.+3DSiam+SE │ 0.916/0.711 │ 0.848/0.763 │ 0.538/0.375 │ 0.519/0.350 |
| 2021 | Trad.+3DSiam+SE proposed | Specificity | 0.763 | split: val · validation=stratified cross-validation · label_fraction=50% | Imbalance-Aware Self-supervised Learning for 3D Radiomic RepresentationsSource quoteL139: Trad.+3DSiam+SE │ 0.916/0.711 │ 0.848/0.763 │ 0.538/0.375 │ 0.519/0.350 |
| 2020 | Meta-SRGAN proposed | SSIM | 0.7279 | scale=x2 | Arbitrary Scale Super-Resolution for Brain MRI ImagesSource quoteL111: mean │ 17.98 │ 0.6091 │ 18.93 │ 0.6885 │ 18.42 │ 0.7295 │ 18.72 │ 0.7279 |
| 2020 | Meta-SRGAN proposed | PSNR | 18.72 dB | scale=x2 | Arbitrary Scale Super-Resolution for Brain MRI ImagesSource quoteL111: mean │ 17.98 │ 0.6091 │ 18.93 │ 0.6885 │ 18.42 │ 0.7295 │ 18.72 │ 0.7279 |
| 2020 | soft Jaccard (sJaccard) proposed | Dice | 0.747 | region=average of WT, TC, and ET | Optimization for Medical Image Segmentation: Theory and Practice When Evaluating With Dice Score or Jaccard IndexSource quoteL539: All │ 0.639 │ 0.665 │ 0.740 │ 0.747 │ 0.716 |
| 2020 | soft Jaccard (sJaccard) proposed | Jaccard | 0.643 | region=average of WT, TC, and ET | Optimization for Medical Image Segmentation: Theory and Practice When Evaluating With Dice Score or Jaccard IndexSource quoteL544: All │ 0.522 │ 0.554 │ 0.632 │ 0.643 │ 0.606 |
| 2020 | ReMIC proposed | NRMSE (↓) | 0.2008 | split: test · target=T1 | Multi-Domain Image Completion for Random Missing Input DataSource quoteL357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2020 | ReMIC proposed | PSNR (↑) | 28.5508 | split: test · target=T1 | Multi-Domain Image Completion for Random Missing Input DataSource quoteL357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2020 | ReMIC proposed | SSIM (↑) | 0.9618 | split: test · target=T1 | Multi-Domain Image Completion for Random Missing Input DataSource quoteL357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2020 | ConResNet (context residual mapping and context attention mapping) proposed | Dice score, ET | 81.87% | split: val · subset=35 randomly selected training cases | Inter-Slice Context Residual Learning for 3D Medical Image SegmentationSource quoteL276: ConResNet │ \checkmark │ \checkmark │ 81.87 │ 89.77 │ 88.14 │ 3.14 │ 5.08 │ 5.16 |
| 2020 | ConResNet (context residual mapping and context attention mapping) proposed | Dice score, WT | 89.77% | split: val · subset=35 randomly selected training cases | Inter-Slice Context Residual Learning for 3D Medical Image SegmentationSource quoteL276: ConResNet │ \checkmark │ \checkmark │ 81.87 │ 89.77 │ 88.14 │ 3.14 │ 5.08 │ 5.16 |
| 2020 | ConResNet (context residual mapping and context attention mapping) proposed | Dice score, TC | 88.14% | split: val · subset=35 randomly selected training cases | Inter-Slice Context Residual Learning for 3D Medical Image SegmentationSource quoteL276: ConResNet │ \checkmark │ \checkmark │ 81.87 │ 89.77 │ 88.14 │ 3.14 │ 5.08 │ 5.16 |
| 2019 | Proposed pathology-factorization method (paired) proposed | Identity | 0.88 | paired · training-pairing=paired | Adversarial Pseudo Healthy Synthesis Needs Pathology FactorizationSource quoteL228: proposed (paired) │ \mathbf{0.88\mathbin{\smash{ |
| 2019 | Proposed pathology-factorization method (paired) proposed | Healthiness | 0.99 | paired · training-pairing=paired | Adversarial Pseudo Healthy Synthesis Needs Pathology FactorizationSource quoteL234: 0.03}^* │ \mathbf{0.99\mathbin{\smash{ |
| 2019 | Proposed pathology-factorization method (unpaired) proposed | Healthiness | 0.98 | unpaired · training-pairing=unpaired | Adversarial Pseudo Healthy Synthesis Needs Pathology FactorizationSource quoteL207: 0.03 │ 0.98\mathbin{\smash{ |
| 2019 | No NewNet + OctConv + SWA + postprocessing (final model) proposed | Dice (whole tumor) | 0.90 | noise=none · components=OctConv, SWA, postprocessing | Robustness of Brain Tumor SegmentationSource quoteL814: 0.90 for the whole tumor and 0.85 for the tumor core our approach is on par |
| 2019 | HarmonicGAN (Histogram) proposed | MSE ↓ | 216.83 | split: test · variant=Histogram · direction=Flair-to-T1 | Harmonic Unpaired Image-to-image TranslationSource quoteL269: \quad Histogram │ 6.38 │ 216.83 │ 24.34 │ 0.83 │ 5.04 │ 163.29 │ 26.72 │ 0.75 |
| 2019 | CPRN proposed | PSNR | 36.500 | scale=×2 · subset=slices 60, 80, 100, 120, 140 · degradation=bicubic downsampling | Coupled-Projection Residual Network for MRI Super-ResolutionSource quoteL156: CPRN │ ×2 │ \textcolor[rgb]{1.00,0.00,0.00}{36.500/0.9911} │ \textcolor[rgb]{1.00,0.00,0.00}{28.324/0.9268} │ \textcolor[rgb]{1.00,0.00,0.00}{26.114/0.9515} SRCNN │ ×4 │ 26.780/0.7034 │ 20.103/0.7831 │ 19.998/0.8142 |
| 2019 | CPRN proposed | PSNR | 29.330 | scale=×4 · subset=slices 60, 80, 100, 120, 140 · degradation=bicubic downsampling | Coupled-Projection Residual Network for MRI Super-ResolutionSource quoteL160: CPRN │ ×4 │ \textcolor[rgb]{1.00,0.00,0.00}{29.330/0.9439} │ \textcolor[rgb]{1.00,0.00,0.00}{22.331/0.8142} │ \textcolor[rgb]{1.00,0.00,0.00}{21.981/0.8687} |
| 2019 | Modified U-Net + \(\mathcal{L}-MScnn\) proposed | Dice | 0.880 | split: val · semi-supervised · labeled-data=1/4 | Mumford-Shah Loss Functional for Image Segmentation With Deep LearningSource quoteL346: \multicolumn{1}{l|}{{Modified U-Net + \boldsymbol{\mathcal{L}-MScnn}}} │ 0.880 │ 0.904 │ 0.858 │ 0.786 |
| 2019 | SCALP proposed | 3D ASA | 0.9848 | Average 3D ASA for supervoxel decomposition on the brain MRI data. | Robust superpixels using color and contour features along linear pathSource quoteL1095: Finally, note that SCALP obtains an average 3D ASA measure of 0.9848, and outperforms |
| 2018 | AAE-128 proposed | AUC | 0.70 | region=whole-tumor · modality=T2w · resolution=128×128 | Deep Generative Models in the Real-World: An Open Challenge from Medical ImagingSource quoteL140: AAE-128 │ (2,2,64) │ 0.70 │ 0.41 │ 0.63 │ 0.06 |
| 2018 | VAE-128 proposed | mDSC | 0.42 | region=whole-tumor · modality=T2w · resolution=128×128 | Deep Generative Models in the Real-World: An Open Challenge from Medical ImagingSource quoteL137: VAE-128 │ (2,2,64) │ 0.69 │ 0.42 │ 0.64 │ 0.08 |
| 2018 | SynNet (Joint Loss) proposed | SSIM | 0.86 | split: test · loss=joint · input-modality=T1 · target-modality=T2 | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteL198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 2018 | SynNet (Joint Loss) proposed | SSIM | 0.70 | split: test · loss=joint · input-modality=T2 · target-modality=T1 | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteL198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 2016 | HeMIS proposed | DSC, Complete tumor category | 71.26% | split: test · modalities=FLAIR only · missing-modalities=T1W, T1C, T2W | HeMIS: Hetero-Modal Image SegmentationSource quoteL351: \bullet │ \circ │ \circ │ \circ │ 34.48 │ 9.77 │ 38.46 │ 71.26 │ 72.30 │ 63.81 │ 37.45 │ 0.00 │ 34.26 │ 5.57 │ 6.25 │ 15.90 |