| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ReMIC SOTA frontier | 0.9618 | 2021-01-01 | target=T1 · Image-completion result from the extended results table; quantitative test generation… | Multi-Domain Image Completion for Random Missing Input DataSource quote{ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2 | TransCSCN | 0.943 | 2022-01-01 | modality-direction=T1w-to-FLAIR · Table 1 average; 45 BraTS test cases; bias-field-corrected scans; unsupervised method… | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quote0.943 |
| 3 | MRNet | 0.9411 | 2024-12-01 | plane=axial · direction=FLAIR-to-T2 · Paired FLAIR-to-T2 evaluation on axial cross-sections; test set comprises 127 persons… | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteOURS │ 31.2852 │ 0.9411 │ \checkmark |
| 4 | SynNet (Joint Loss) SOTA frontier (+3 variants) | 0.86 | 2018-06-01 | loss=joint · input-modality=T1 · target-modality=T2 · T1 input and T2 output; BRATS dataset description reports 96 training and 24 testing … | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteJoint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 5 | SyMOT-Flow | 0.83 | 2023-08-01 | encoding=VQ-VAE-2 · subgroup=T2 · BraTS MRI slices; 1,000 training and 251 test images per modality; VQ-VAE-2 feature-s… | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteOurs │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
Metricdice (30)psnr (27)ssim (19)dsc (11)inconsistency with radiologist evaluations lower (6)iou (5)
Regimefine-tuned (9)unsupervised (8)unsupervised-domain-adaptation (6)semi-supervised (5)weakly-supervised (4)few-shot (4)
Showing 35 of 35 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | JiT-L/16 (direct IN transfer) proposed | gFID | 40.17 | split: test · in-initialized-training | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL884: 40.17 |
| 2026 | JiT-B/16 (IN initialization) proposed | gFID | 31.73 | split: test · fine-tuned | From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image GenerationSource quoteL865: 31.73 |
| 2026 | VariaFlow proposed | AUROC | 0.78 | split: test · cross-domain | VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly DetectionSource quoteL34: the highest AUROC (0.94, 0.80, 0.78) on each and the high- |
| 2025 | fastWDM3D (T=2) proposed | AST (average sampling time per volume) | 1.81 s | split: test · sampling-steps=2 | fastWDM3D: Fast and Accurate 3D Healthy Tissue InpaintingSource quoteL134: Ours (fastWDM3D (T=2)) │ 0.86 ± 0.12 │ 0.0079 ± 0.0063 │ 22.26 ± 3.97 │ \hphantom{0}\SI{1.81}{\second} |
| 2025 | IterMask3D proposed | DSC | 69.7 | split: test · test-time-refinement · tuning=test-set, 3 standard deviations · modality=FLAIR · training-data=cognitively normal ADNI/OASIS · dimensionality=3D | IterMask3D: Unsupervised Anomaly Detection and Segmentation with Test-Time Iterative Mask Refinement in 3D Brain MRSource quoteL534: \multicolumn{1}{l|}{IterMask3D} │ 69.7 │ 99.2 │ 72.7 │ 71.1 │ 56.7 │ 32.2 │ 5.1 |
| 2025 | SIPL proposed | DSC | 83.0% | split: test · regions=whole tumor, enhancing tumor, tumor core · train-val-test-split=80:5:15 | Advancing Medical Image Segmentation via Self-supervised Instance-adaptive Prototype LearningSource quoteL197: SIPL (ours) │ 83.0 │ -- |
| 2025 | VIViT+SSL proposed | Mean Dice | 0.883 | split: test · resolution=128×128×128 | VIViT: Variable-Input Vision Transformer Framework for 3D MR Image SegmentationSource quoteL130: VIViT+SSL │ 0.624 │ 0.871 │ 0.893 │ 0.884 │ 0.883 |
| 2025 | SpectMamba proposed | mAP | 75.34 | split: test · epochs=200 · pretraining=none | SpectMamba: Integrating Frequency and State Space Models for Enhanced Medical Image DetectionSource quoteL275: {SpectMamba} │ 89.83 │ 78.64 │ 57.54 │ 75.34 │ 95.35 │ 85.64 │ 68.24 │ 83.08 |
| 2024 | QCResUNet proposed | Pearson r (DSC prediction) | 0.968 | split: test · metric-target=DSC · prediction-level=subject-level · segmentation-models=nnUNet, nnFormer | QCResUNet: Joint subject-level and voxel-level segmentation quality predictionSource quoteL279: Specifically, on the BraTS internal testing set with segmentations generated by nnUNet and nnFormer, the proposed method achieved a small mean MAE of 0.056 and 0.064 for NSD and DSC prediction, respectively. The predicted NSD and DSC also showed a strong correlation with the corresponding ground truth, achieving Pearson r values of 0.958 and 0.968, respectively. Importantly, the proposed method generalized well for segmentation produced by different methods (i.e., DeepMedic), which had not been used during training, achieving an average MAE of 0.074 and 0.062 for NSD and DSC prediction. Similarly, the predicted NSD and DSC showed a strong correlation with their ground truth with Pearson r values of 0.937 and 0.962, respectively. |
| 2024 | McCaD proposed | Dice score | 0.8004 | split: test · retained-contrasts=T1w, FLAIR · synthetic-contrast=T2w · segmentation-target=whole-tumor | McCaD: Multi-Contrast MRI Conditioned, Adaptive Adversarial Diffusion Model for High-Fidelity MRI SynthesisSource quoteL210: AttGAN │ DDPM │ Hi-Net │ MM-GAN │ McCaD │ Complete T2w │ 0.7692 │ 0.7987 │ 0.7921 │ 0.7991 │ 0.8004 │ 0.8188 T2w + FLAIR │ 0.6974 │ 0.6262 │ 0.7401 │ 0.7449 │ 0.7602 │ 0.8188 |
| 2024 | HF-GAN (ours) imputation proposed | Dice (ET) | 0.6438 | split: test · evaluation=after imputation · architecture=2D slice-based · test-subjects=85 · segmentation-region=ET | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL284: \multicolumn{4}{c|}{Average} │ 0.6196* (0.3202) │ 0.5130* (0.3041) │ 0.4957* (0.3598) │ 0.8436* (0.1279) │ 0.7247* (0.1728) │ 0.6139* (0.3619) │ 0.8405* (0.1356) │ 0.7178* (0.1766) │ 0.6313* (0.3446) │ 0.8632 (0.1033) │ 0.7488 (0.1588) │ 0.6174* (0.3743) │ 0.8618 (0.1071) │ 0.7472 (0.1625) │ 0.6438 (0.3397) |
| 2024 | MRNet proposed | PSNR | 31.2852 | split: test · plane=axial · direction=FLAIR-to-T2 | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteL269: OURS │ 31.2852 │ 0.9411 │ \checkmark |
| 2024 | MRNet proposed | SSIM | 0.9411 | split: test · plane=axial · direction=FLAIR-to-T2 | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteL269: OURS │ 31.2852 │ 0.9411 │ \checkmark |
| 2024 | HiDiff proposed non-standard slice | Average Dice | 51.77 | split: test · subset=small tumors; pixel-wise tumor size <100 | HiDiff: Hybrid Diffusion Framework for Medical Image SegmentationSource quoteL506: {{HiDiff}\xspace (ours)} │ 51.77 │ 8.76(20.13%) │ 59.00 │ 47.30 │ 49.00 |
| 2024 | X-Diffusion (1-slice input) proposed | Test 3D PSNR | 23.10 | split: test · sequence=FLAIR T2 · input-slices=1 | X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion ModelsSource quoteL131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01 |
| 2023 | SyMOT-Flow proposed | SSIM ↑ | 0.83 | split: test · encoding=VQ-VAE-2 · subgroup=T2 | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteL529: Ours │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 30.68 dB | split: test · scale=8x out-of-scale · target-modality=T2 · reference-modality=T1 | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL576: 30.68 |
| 2023 | LKA-E proposed | HD95 (WT) | 2.449 | split: test | Large-kernel Attention for Efficient and Robust Brain Lesion SegmentationSource quoteL147: LKA-E (Ours) │ \multicolumn{1}{l|}{0.888} │ \multicolumn{1}{l|}{0.932} │ 0.939 │ \multicolumn{1}{l|}{1.414} │ \multicolumn{1}{l|}{2.000} │ 2.449^* |
| 2023 | Ours ensemble (1/4 train/validation task split) proposed | Pixel-wise AP (average precision) | 76.2 | split: test · ensemble=yes · modality=brain MRI · task-split=1/4 train/validation | Many tasks make light work: Learning to localise medical anomalies from multiple synthetic tasksSource quoteL229: \multicolumn{3}{l}{Ours} │ 87.6/92.2 │ 62.0/84.6 │ 76.2/99.1 │ 45.9/97.9 │ 78.4/76.6 │ 71.2/81.1 │ 21.1/75.6 │ 21.4/81.2 |
| 2022 | DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposed | MAE | 0.51 stars | split: test · backbone=DenseNet121 · optimizer=Ranger21 | Deep Quality Estimation: Creating Surrogate Models for Human Quality RatingsSource quoteL119: 0.51 |
| 2022 | DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposed | RMSE | 0.80 stars | split: test · backbone=DenseNet121 · optimizer=Ranger21 | Deep Quality Estimation: Creating Surrogate Models for Human Quality RatingsSource quoteL120: 0.80 |
| 2022 | DenseNet121 (Ranger21 optimizer, percentile normalization, BraTS label encoding) proposed | Pearson r | 0.66 | split: test · backbone=DenseNet121 · optimizer=Ranger21 | Deep Quality Estimation: Creating Surrogate Models for Human Quality RatingsSource quoteL121: 0.66 |
| 2022 | TransCSCN proposed | PSNR (dB) | 39.12 dB | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL439: 39.12 |
| 2022 | TransCSCN proposed | SSIM | 0.943 | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL448: 0.943 |
| 2022 | TransCSCN proposed | Dice (in %) | 85.68% | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL457: 85.68 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 41.49 | split: test · orientation=axial · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 37.36 | split: test · orientation=coronal · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 37.18 | split: test · orientation=sagittal · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2020 | ReMIC proposed | NRMSE (↓) | 0.2008 | split: test · target=T1 | Multi-Domain Image Completion for Random Missing Input DataSource quoteL357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2020 | ReMIC proposed | PSNR (↑) | 28.5508 | split: test · target=T1 | Multi-Domain Image Completion for Random Missing Input DataSource quoteL357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2020 | ReMIC proposed | SSIM (↑) | 0.9618 | split: test · target=T1 | Multi-Domain Image Completion for Random Missing Input DataSource quoteL357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2019 | HarmonicGAN (Histogram) proposed | MSE ↓ | 216.83 | split: test · variant=Histogram · direction=Flair-to-T1 | Harmonic Unpaired Image-to-image TranslationSource quoteL269: \quad Histogram │ 6.38 │ 216.83 │ 24.34 │ 0.83 │ 5.04 │ 163.29 │ 26.72 │ 0.75 |
| 2018 | SynNet (Joint Loss) proposed | SSIM | 0.86 | split: test · loss=joint · input-modality=T1 · target-modality=T2 | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteL198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 2018 | SynNet (Joint Loss) proposed | SSIM | 0.70 | split: test · loss=joint · input-modality=T2 · target-modality=T1 | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteL198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 2016 | HeMIS proposed | DSC, Complete tumor category | 71.26% | split: test · modalities=FLAIR only · missing-modalities=T1W, T1C, T2W | HeMIS: Hetero-Modal Image SegmentationSource quoteL351: \bullet │ \circ │ \circ │ \circ │ 34.48 │ 9.77 │ 38.46 │ 71.26 │ 72.30 │ 63.81 │ 37.45 │ 0.00 │ 34.26 │ 5.57 │ 6.25 │ 15.90 |