BraTS

93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.91.0201820222025SynNet (Weighted L₂ loss): 0.69 (2018)SynNet (Joint Loss): 0.7 (2018)SynNet (Weighted L₂ loss): 0.77 (2018)SynNet (Joint Loss): 0.86 (2018)ReMIC: 0.9618 (2021)TransCSCN: 0.943 (2022)SyMOT-Flow: 0.83 (2023)MRNet: 0.9411 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 1 of 1 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2021MBConv-Base proposedDice score0.7513split: hold-out · channels=30, 60, 120, 180, 240 · resolution=256x256x160 · expand-ratio=2 · memory-budget=14GBMemory Efficient 3D U-Net with Reversible Mobile Inverted Bottlenecks for Brain Tumor Segmentation
Source quote
L81: As seen in Table \ref{tab1}, our best MBConv reversible architecture was found to be the MBConv-Base variant which achieves a mean Dice score (averaged over all classes) above 0.7317 on hold out set after 50 epochs of training and Dice score of 0.7513 after convergence. The rate of convergence is faster than the baseline which only reaches a Dice score of 0.7184 after 50 epochs of training although the final score after convergence is slightly higher (0.7513). In Figure \ref{fig1}, a sample segmentation for an example from the the training set and an example from the holdout set indicate a close match between the prediction and the ground truth.