BraTS
93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ReMIC SOTA frontier | 0.9618 | 2021-01-01 | target=T1 · Image-completion result from the extended results table; quantitative test generation… | Multi-Domain Image Completion for Random Missing Input DataSource quote{ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2 | TransCSCN | 0.943 | 2022-01-01 | modality-direction=T1w-to-FLAIR · Table 1 average; 45 BraTS test cases; bias-field-corrected scans; unsupervised method… | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quote0.943 |
| 3 | MRNet | 0.9411 | 2024-12-01 | plane=axial · direction=FLAIR-to-T2 · Paired FLAIR-to-T2 evaluation on axial cross-sections; test set comprises 127 persons… | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteOURS │ 31.2852 │ 0.9411 │ \checkmark |
| 4 | SynNet (Joint Loss) SOTA frontier (+3 variants) | 0.86 | 2018-06-01 | loss=joint · input-modality=T1 · target-modality=T2 · T1 input and T2 output; BRATS dataset description reports 96 training and 24 testing … | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteJoint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 5 | SyMOT-Flow | 0.83 | 2023-08-01 | encoding=VQ-VAE-2 · subgroup=T2 · BraTS MRI slices; 1,000 training and 251 test images per modality; VQ-VAE-2 feature-s… | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteOurs │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
Metricdice (30)psnr (27)ssim (19)dsc (11)inconsistency with radiologist evaluations lower (6)iou (5)
Regimefine-tuned (9)unsupervised (8)unsupervised-domain-adaptation (6)semi-supervised (5)weakly-supervised (4)few-shot (4)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | FullGrad (DeiT-S) baseline | DSC | 33.2% | weakly-supervised · target=whole-tumor · backbone=DeiT-S · modality=T2 FLAIR | Hybrid Transformer-Mamba Architecture for Weakly Supervised Volumetric Medical SegmentationSource quoteL191: FullGrad \cite{srinivas2019full} │ DeiT-S │ 4.0 │ 33.2 (7) │ 5.1 (7) │ 19.8 (8) │ 20.5 (3) │ 16.3 (3) │ 25.1 (2) │ 37.7 (2) │ 4.3 (2) │ 23.1 (2) |
| 2023 | CG-CDM proposed | infer time | 2.78s | weakly-supervised · Q=400 · R=10 · s=10 · τ=0.95 · denoising-iterations=10 | Conditional Diffusion Models for Weakly Supervised Medical Image SegmentationSource quoteL186: CG-CDM │ 0.563±0.023 │ 0.450±0.012 │ 19.2±3.2 │ 2.78s |
| 2023 | Ensemble ResNet-34x50 `and' proposed | Best AVG DSC | 70.3 | weakly-supervised · backbone=ResNet-34 + ResNet-50 ensemble · resolution=34x50 · supervision=image-level labels | Exploring Weakly Supervised Semantic Segmentation Ensembles for Medical Imaging SystemsSource quoteL232: Ensemble ResNet-34x50 `and' │ 70.3 │ 54.2 |
| 2023 | WSS-CMER baseline | Best AVG DSC | 59.7 | weakly-supervised · supervision=image-level labels | Exploring Weakly Supervised Semantic Segmentation Ensembles for Medical Imaging SystemsSource quoteL225: WSS-CMER │ 59.7 │ 42.6 |