BraTS
93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ReMIC SOTA frontier | 0.9618 | 2021-01-01 | target=T1 · Image-completion result from the extended results table; quantitative test generation… | Multi-Domain Image Completion for Random Missing Input DataSource quote{ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2 | TransCSCN | 0.943 | 2022-01-01 | modality-direction=T1w-to-FLAIR · Table 1 average; 45 BraTS test cases; bias-field-corrected scans; unsupervised method… | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quote0.943 |
| 3 | MRNet | 0.9411 | 2024-12-01 | plane=axial · direction=FLAIR-to-T2 · Paired FLAIR-to-T2 evaluation on axial cross-sections; test set comprises 127 persons… | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteOURS │ 31.2852 │ 0.9411 │ \checkmark |
| 4 | SynNet (Joint Loss) SOTA frontier (+3 variants) | 0.86 | 2018-06-01 | loss=joint · input-modality=T1 · target-modality=T2 · T1 input and T2 output; BRATS dataset description reports 96 training and 24 testing … | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteJoint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 5 | SyMOT-Flow | 0.83 | 2023-08-01 | encoding=VQ-VAE-2 · subgroup=T2 · BraTS MRI slices; 1,000 training and 251 test images per modality; VQ-VAE-2 feature-s… | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteOurs │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
Metricdice (30)psnr (27)ssim (19)dsc (11)inconsistency with radiologist evaluations lower (6)iou (5)
Regimefine-tuned (9)unsupervised (8)unsupervised-domain-adaptation (6)semi-supervised (5)weakly-supervised (4)few-shot (4)
Showing 2 of 2 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | Expert-guided explainable few-shot learning (guided model) proposed | Accuracy | 83.61% | few-shot · epoch=7 · episodes=60 · explanation-weight-alpha=0.10 | Expert-Guided Explainable Few-Shot Learning for Medical Image DiagnosisSource quoteL107: 7 │ 60 │ 83.61 │ 77.09 |
| 2025 | NAGL proposed | average AUROC | 89.5% | few-shot · reference_samples=N^2+A^1 | Normal-Abnormal Guided Generalist Anomaly DetectionSource quoteL228: \paragraph{Generalization.} Our method exhibits superior generalization capabilities compared to ResAD across multiple datasets. On MVTecAD, under the N^1+A^1 setting, our approach achieves 95.7% image F1-max and 58.9% pixel F1-max, outperforming ResAD by 4.5 and 10.7 percentage points, respectively. Similarly, on VisA, we attain 85.4% image F1-max and 41.8% pixel F1-max, exceeding ResAD by 4.1 and 4.0 percentage points. Furthermore, as shown in Tab.~\ref{tab:exp_medical}, our method demonstrates superior cross-domain generalization, achieving 89.5% average AUROC on the BraTS medical dataset with just two normal and one abnormal sample, a 10.6 percentage point improvement over ResAD (78.9% with N^2 setting). Notably, across all other experimental settings, our method consistently outperforms existing approaches in both anomaly detection and segmentation. These results clearly demonstrate the effectiveness of our method in generalist AD. |