BraTS
93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ReMIC SOTA frontier | 0.9618 | 2021-01-01 | target=T1 · Image-completion result from the extended results table; quantitative test generation… | Multi-Domain Image Completion for Random Missing Input DataSource quote{ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2 | TransCSCN | 0.943 | 2022-01-01 | modality-direction=T1w-to-FLAIR · Table 1 average; 45 BraTS test cases; bias-field-corrected scans; unsupervised method… | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quote0.943 |
| 3 | MRNet | 0.9411 | 2024-12-01 | plane=axial · direction=FLAIR-to-T2 · Paired FLAIR-to-T2 evaluation on axial cross-sections; test set comprises 127 persons… | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteOURS │ 31.2852 │ 0.9411 │ \checkmark |
| 4 | SynNet (Joint Loss) SOTA frontier (+3 variants) | 0.86 | 2018-06-01 | loss=joint · input-modality=T1 · target-modality=T2 · T1 input and T2 output; BRATS dataset description reports 96 training and 24 testing … | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteJoint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 5 | SyMOT-Flow | 0.83 | 2023-08-01 | encoding=VQ-VAE-2 · subgroup=T2 · BraTS MRI slices; 1,000 training and 251 test images per modality; VQ-VAE-2 feature-s… | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteOurs │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
Metricdice (30)psnr (27)ssim (19)dsc (11)inconsistency with radiologist evaluations lower (6)iou (5)
Regimefine-tuned (9)unsupervised (8)unsupervised-domain-adaptation (6)semi-supervised (5)weakly-supervised (4)few-shot (4)
Showing 19 of 19 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | SynerMedGen (Stage I+II) proposed | SSIM | 90.62 | modality=FL.→T1 | SynerMedGen: Synergizing Medical Multimodal Understanding with Generation via Task AlignmentSource quoteL733: 90.62+9.28 |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposed | Mean SSIM | 0.95 | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | SynerMedGen-UCG (Stage II) ablation | SSIM | 81.34 | variant=Stage II only · modality=FL.→T1 | SynerMedGen: Synergizing Medical Multimodal Understanding with Generation via Task AlignmentSource quoteL719: 81.34 |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baseline | Mean SSIM | 0.96 | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressed | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2024 | HF-GAN proposed | SSIM | 0.9393 | aggregation=average across missing-sequence scenarios · architecture=2D slice-based | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | MRNet proposed | SSIM | 0.9411 | split: test · plane=axial · direction=FLAIR-to-T2 | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteL269: OURS │ 31.2852 │ 0.9411 │ \checkmark |
| 2024 | Hyper-GAE (3D) baseline | SSIM | 0.9361 | evaluation=2D slices · aggregation=average across missing-sequence scenarios · architecture=3D | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | HA-GAN baseline | MS-SSIM | 0.999 | Mean MS-SSIM over 1k generated images; resolution is not specified for this score. | WDM: 3D Wavelet Diffusion Models for High-Resolution Medical Image SynthesisSource quoteL130: \subsubsection{Discussion} (1) Our proposed method outperforms HA-GAN \cite{sun2022hierarchical} on both FID and MS-SSIM metrics. While HA-GAN offers a slightly reduced memory footprint at higher resolutions, we found that it tends to suffer from severe mode collapse, indicated by a high MS-SSIM score of 0.999 on BraTS. As HA-GAN does not require iterative sampling, it is the method with the shortest inference time of \SI{0.4}{\second}/\SI{3}{\second} at the respective resolutions. |
| 2023 | SyMOT-Flow proposed | SSIM ↑ | 0.83 | split: test · encoding=VQ-VAE-2 · subgroup=T2 | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteL529: Ours │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
| 2023 | UNIT baseline | SSIM ↑ | 0.77 | split: test · encoding=VQ-VAE-2 · subgroup=T2 | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteL527: UNIT \cite{liu2017unsupervised} │ 0.79 │ 111.93 │ 0.77 │ 82.23 │ 0.68 │ 116.32 │ 0.48 │ 105.75 |
| 2022 | TransCSCN proposed | SSIM | 0.943 | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL448: 0.943 |
| 2022 | CSCℓ4Net baseline | SSIM | 0.935 | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL447: 0.935 |
| 2020 | Meta-SRGAN proposed | SSIM | 0.7279 | scale=x2 | Arbitrary Scale Super-Resolution for Brain MRI ImagesSource quoteL111: mean │ 17.98 │ 0.6091 │ 18.93 │ 0.6885 │ 18.42 │ 0.7295 │ 18.72 │ 0.7279 |
| 2020 | ReMIC proposed | SSIM (↑) | 0.9618 | split: test · target=T1 | Multi-Domain Image Completion for Random Missing Input DataSource quoteL357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2020 | Bicubic Interpolation baseline | SSIM | 0.6091 | scale=x2 | Arbitrary Scale Super-Resolution for Brain MRI ImagesSource quoteL111: mean │ 17.98 │ 0.6091 │ 18.93 │ 0.6885 │ 18.42 │ 0.7295 │ 18.72 │ 0.7279 |
| 2018 | SynNet (Joint Loss) proposed | SSIM | 0.86 | split: test · loss=joint · input-modality=T1 · target-modality=T2 | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteL198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 2018 | SynNet (Joint Loss) proposed | SSIM | 0.70 | split: test · loss=joint · input-modality=T2 · target-modality=T1 | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteL198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 2018 | SynNet (Weighted L₂ loss) ablation | SSIM | 0.77 | split: test · loss=weighted-L2 · input-modality=T1 · target-modality=T2 | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteL197: Weighted L-2 │ T1 │ T2 │ 21.80 │ 0.77 │ T2 │ T1 │ 20.61 │ 0.69 |
| 2018 | SynNet (Weighted L₂ loss) ablation | SSIM | 0.69 | split: test · loss=weighted-L2 · input-modality=T2 · target-modality=T1 | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteL197: Weighted L-2 │ T1 │ T2 │ 21.80 │ 0.77 │ T2 │ T1 │ 20.61 │ 0.69 |