BraTS

93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.91.0201820222025SynNet (Weighted L₂ loss): 0.69 (2018)SynNet (Joint Loss): 0.7 (2018)SynNet (Weighted L₂ loss): 0.77 (2018)SynNet (Joint Loss): 0.86 (2018)ReMIC: 0.9618 (2021)TransCSCN: 0.943 (2022)SyMOT-Flow: 0.83 (2023)MRNet: 0.9411 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024MRNet proposedSSIM0.9411split: test · plane=axial · direction=FLAIR-to-T2MRNet: Multifaceted Resilient Networks for Medical Image-to-Image Translation
Source quote
L269: OURS │ 31.2852 │ 0.9411 │ \checkmark
2023SyMOT-Flow proposedSSIM ↑0.83split: test · encoding=VQ-VAE-2 · subgroup=T2Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal Transport
Source quote
L529: Ours │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27
2023UNIT baselineSSIM ↑0.77split: test · encoding=VQ-VAE-2 · subgroup=T2Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal Transport
Source quote
L527: UNIT \cite{liu2017unsupervised} │ 0.79 │ 111.93 │ 0.77 │ 82.23 │ 0.68 │ 116.32 │ 0.48 │ 105.75
2022TransCSCN proposedSSIM0.943split: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L448: 0.943
2022CSCℓ4Net baselineSSIM0.935split: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L447: 0.935
2020ReMIC proposedSSIM (↑)0.9618split: test · target=T1Multi-Domain Image Completion for Random Missing Input Data
Source quote
L357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}}
2018SynNet (Joint Loss) proposedSSIM0.86split: test · loss=joint · input-modality=T1 · target-modality=T2SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image Synthesis
Source quote
L198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex]
2018SynNet (Joint Loss) proposedSSIM0.70split: test · loss=joint · input-modality=T2 · target-modality=T1SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image Synthesis
Source quote
L198: Joint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex]
2018SynNet (Weighted L₂ loss) ablationSSIM0.77split: test · loss=weighted-L2 · input-modality=T1 · target-modality=T2SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image Synthesis
Source quote
L197: Weighted L-2 │ T1 │ T2 │ 21.80 │ 0.77 │ T2 │ T1 │ 20.61 │ 0.69
2018SynNet (Weighted L₂ loss) ablationSSIM0.69split: test · loss=weighted-L2 · input-modality=T2 · target-modality=T1SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image Synthesis
Source quote
L197: Weighted L-2 │ T1 │ T2 │ 21.80 │ 0.77 │ T2 │ T1 │ 20.61 │ 0.69