BraTS

93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.91.0201820222025SynNet (Weighted L₂ loss): 0.69 (2018)SynNet (Joint Loss): 0.7 (2018)SynNet (Weighted L₂ loss): 0.77 (2018)SynNet (Joint Loss): 0.86 (2018)ReMIC: 0.9618 (2021)TransCSCN: 0.943 (2022)SyMOT-Flow: 0.83 (2023)MRNet: 0.9411 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 27 of 27 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposedMean PSNR27.3 dBsplit: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2026MRIComp4Flow WFM trained on JPEG2000-compressed data at 200:1 proposedPSNR24.65 dBsplit: val · modality=T1n · compression=JPEG2000 200:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L125: 200 │ 23.25 │ 24.65 │ 23.07 │ 22.63 │ 0.879 │ 0.968 │ 0.937 │ 0.902
2026MRIComp4Flow WFM trained on JPEG2000-compressed data at 400:1 proposedPSNR20.94 dBsplit: val · modality=T1n · compression=JPEG2000 400:1MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L126: 400 │ 19.30 │ 20.94 │ 21.29 │ 17.18 │ 0.852 │ 0.829 │ 0.814 │ 0.750
2026MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baselineMean PSNR27.0 dBsplit: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressedMRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models
Source quote
L4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}.
2025UniFS proposedPSNR improvement over FSMNet1.06dBacceleration=4× · undersampling-patterns=3UniFS: Unified Multi-Contrast MRI Reconstruction via Frequency-Spatial Fusion
Source quote
L176: As shown in Table \ref{tab1}, UniFS consistently outperforms all competing methods in terms of image reconstruction quality. Compared with the current leading method FSMNet \cite{FSMNet}, which also incorporates frequency feature fusion, UniFS achieves significant PSNR improvements of 1.06dB and 2.00dB under 4× acceleration on the BraTs and HCP datasets. These results highlight the effectiveness of the enhanced frequency fusion design within the CMF module. Furthermore, Fig. \ref{fig2} shows reconstructed images and corresponding error maps from different methods. The zoomed-in views reveal that UniFS achieves more accurate texture recovery, while the noticeably smaller error maps further confirm its superior reconstruction fidelity.
2025FgC2F-UDiff (Our method) proposedPSNR26.34 dBsynthesis=many-to-one · target-modality=T1ce · input-modalities=T1,T2FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI Synthesis
Source quote
L312: \multirow{2}{*}{Our method} │ 26.34 │ 0.894 │ 17.45 │ 20.85 │ 27.19 │ 0.937 │ 16.14 │ 18.74
2025Uni-GAN baselinePSNR25.57 dBsynthesis=many-to-one · target-modality=T1ce · input-modalities=T1,T2FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI Synthesis
Source quote
L308: \multirow{2}{*}{Uni-GAN} │ 25.57 │ 0.886 │ 18.13 │ 21.77 │ 26.54 │ 0.930 │ 16.97 │ 20.07
2024HF-GAN proposedPSNR30.27aggregation=average across missing-sequence scenarios · architecture=2D slice-basedPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately.
2024MRNet proposedPSNR31.2852split: test · plane=axial · direction=FLAIR-to-T2MRNet: Multifaceted Resilient Networks for Medical Image-to-Image Translation
Source quote
L269: OURS │ 31.2852 │ 0.9411 │ \checkmark
2024X-Diffusion (1-slice input) proposedTest 3D PSNR23.10split: test · sequence=FLAIR T2 · input-slices=1X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
Source quote
L131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01
2024Hyper-GAE (3D) baselinePSNR29.54evaluation=2D slices · aggregation=average across missing-sequence scenarios · architecture=3DPrincipled Feature Disentanglement for High-Fidelity Unified Brain MRI Synthesis
Source quote
L301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately.
2024TPDM (1-slice input) baselineTest 3D PSNR10.48split: test · sequence=FLAIR T2 · input-slices=1X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
Source quote
L130: TPDM \cite{TPDM} │ 10.48 │ 9.29 │ 10.86 │ 9.99 │ 11.33 │ 11.09 │ 14.13 │ 12.62 │ 16.65 │ 15.88 │ 31.48 │ 21.70
2023McASSR (Ours; rectangle window 4×16/16×4) proposedPSNR30.68 dBsplit: test · scale=8x out-of-scale · target-modality=T2 · reference-modality=T1Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L576: 30.68
2023LTE* [13] (SwinIR backbone; reference and target concatenated) baselinePSNR29.97 dBscale=8x out-of-scale · backbone=SwinIR · target-modality=T2 · reference-modality=T1Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale Upsampling
Source quote
L565: 29.97
2022TransCSCN proposedPSNR (dB)39.12 dBsplit: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L439: 39.12
2022DiffusionMBIR proposedPSNR ↑41.49split: test · orientation=axial · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953
2022DiffusionMBIR proposedPSNR ↑37.36split: test · orientation=coronal · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953
2022DiffusionMBIR proposedPSNR ↑37.18split: test · orientation=sagittal · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953
2022CSCℓ4Net baselinePSNR (dB)37.36 dBsplit: test · modality-direction=T1w-to-FLAIRGeneralized Brain Image Synthesis with Transferable Convolutional Sparse Coding Networks
Source quote
L438: 37.36
2022Score-MRI baselinePSNR ↑40.38split: test · orientation=axial · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L274: Score-MRI\cite{chung2022score} │ 40.38 │ 0.968 │ 33.97 │ 0.925 │ 34.02 │ 0.928
2022Score-MRI baselinePSNR ↑33.97split: test · orientation=coronal · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L274: Score-MRI\cite{chung2022score} │ 40.38 │ 0.968 │ 33.97 │ 0.925 │ 34.02 │ 0.928
2022Score-MRI baselinePSNR ↑34.02split: test · orientation=sagittal · acceleration=2× · training-data=fastMRI 2019 kneeSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Source quote
L274: Score-MRI\cite{chung2022score} │ 40.38 │ 0.968 │ 33.97 │ 0.925 │ 34.02 │ 0.928
2020Meta-SRGAN proposedPSNR18.72 dBscale=x2Arbitrary Scale Super-Resolution for Brain MRI Images
Source quote
L111: mean │ 17.98 │ 0.6091 │ 18.93 │ 0.6885 │ 18.42 │ 0.7295 │ 18.72 │ 0.7279
2020ReMIC proposedPSNR (↑)28.5508split: test · target=T1Multi-Domain Image Completion for Random Missing Input Data
Source quote
L357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}}
2020EDSR baselinePSNR18.93 dBscale=x2Arbitrary Scale Super-Resolution for Brain MRI Images
Source quote
L111: mean │ 17.98 │ 0.6091 │ 18.93 │ 0.6885 │ 18.42 │ 0.7295 │ 18.72 │ 0.7279
2019CPRN proposedPSNR36.500scale=×2 · subset=slices 60, 80, 100, 120, 140 · degradation=bicubic downsamplingCoupled-Projection Residual Network for MRI Super-Resolution
Source quote
L156: CPRN │ ×2 │ \textcolor[rgb]{1.00,0.00,0.00}{36.500/0.9911} │ \textcolor[rgb]{1.00,0.00,0.00}{28.324/0.9268} │ \textcolor[rgb]{1.00,0.00,0.00}{26.114/0.9515} SRCNN │ ×4 │ 26.780/0.7034 │ 20.103/0.7831 │ 19.998/0.8142
2019CPRN proposedPSNR29.330scale=×4 · subset=slices 60, 80, 100, 120, 140 · degradation=bicubic downsamplingCoupled-Projection Residual Network for MRI Super-Resolution
Source quote
L160: CPRN │ ×4 │ \textcolor[rgb]{1.00,0.00,0.00}{29.330/0.9439} │ \textcolor[rgb]{1.00,0.00,0.00}{22.331/0.8142} │ \textcolor[rgb]{1.00,0.00,0.00}{21.981/0.8687}