BraTS
93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ReMIC SOTA frontier | 0.9618 | 2021-01-01 | target=T1 · Image-completion result from the extended results table; quantitative test generation… | Multi-Domain Image Completion for Random Missing Input DataSource quote{ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2 | TransCSCN | 0.943 | 2022-01-01 | modality-direction=T1w-to-FLAIR · Table 1 average; 45 BraTS test cases; bias-field-corrected scans; unsupervised method… | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quote0.943 |
| 3 | MRNet | 0.9411 | 2024-12-01 | plane=axial · direction=FLAIR-to-T2 · Paired FLAIR-to-T2 evaluation on axial cross-sections; test set comprises 127 persons… | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteOURS │ 31.2852 │ 0.9411 │ \checkmark |
| 4 | SynNet (Joint Loss) SOTA frontier (+3 variants) | 0.86 | 2018-06-01 | loss=joint · input-modality=T1 · target-modality=T2 · T1 input and T2 output; BRATS dataset description reports 96 training and 24 testing … | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteJoint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 5 | SyMOT-Flow | 0.83 | 2023-08-01 | encoding=VQ-VAE-2 · subgroup=T2 · BraTS MRI slices; 1,000 training and 251 test images per modality; VQ-VAE-2 feature-s… | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteOurs │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
Metricdice (30)psnr (27)ssim (19)dsc (11)inconsistency with radiologist evaluations lower (6)iou (5)
Regimefine-tuned (9)unsupervised (8)unsupervised-domain-adaptation (6)semi-supervised (5)weakly-supervised (4)few-shot (4)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposed | Mean PSNR | 27.3 dB | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | MRIComp4Flow WFM trained on JPEG2000-compressed data at 200:1 proposed | PSNR | 24.65 dB | split: val · modality=T1n · compression=JPEG2000 200:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL125: 200 │ 23.25 │ 24.65 │ 23.07 │ 22.63 │ 0.879 │ 0.968 │ 0.937 │ 0.902 |
| 2026 | MRIComp4Flow WFM trained on JPEG2000-compressed data at 400:1 proposed | PSNR | 20.94 dB | split: val · modality=T1n · compression=JPEG2000 400:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL126: 400 │ 19.30 │ 20.94 │ 21.29 │ 17.18 │ 0.852 │ 0.829 │ 0.814 │ 0.750 |
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on uncompressed data baseline | Mean PSNR | 27.0 dB | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=uncompressed | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |