BraTS
93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ReMIC SOTA frontier | 0.9618 | 2021-01-01 | target=T1 · Image-completion result from the extended results table; quantitative test generation… | Multi-Domain Image Completion for Random Missing Input DataSource quote{ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2 | TransCSCN | 0.943 | 2022-01-01 | modality-direction=T1w-to-FLAIR · Table 1 average; 45 BraTS test cases; bias-field-corrected scans; unsupervised method… | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quote0.943 |
| 3 | MRNet | 0.9411 | 2024-12-01 | plane=axial · direction=FLAIR-to-T2 · Paired FLAIR-to-T2 evaluation on axial cross-sections; test set comprises 127 persons… | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteOURS │ 31.2852 │ 0.9411 │ \checkmark |
| 4 | SynNet (Joint Loss) SOTA frontier (+3 variants) | 0.86 | 2018-06-01 | loss=joint · input-modality=T1 · target-modality=T2 · T1 input and T2 output; BRATS dataset description reports 96 training and 24 testing … | SynNet: Structure-Preserving Fully Convolutional Networks for Medical Image SynthesisSource quoteJoint Loss │ T1 │ T2 │ 22.80 │ 0.86 │ T2 │ T1 │ 21.65 │ 0.70\\[1ex] |
| 5 | SyMOT-Flow | 0.83 | 2023-08-01 | encoding=VQ-VAE-2 · subgroup=T2 · BraTS MRI slices; 1,000 training and 251 test images per modality; VQ-VAE-2 feature-s… | Arbitrary Distributions Mapping via SyMOT-Flow: A Flow-based Approach Integrating Maximum Mean Discrepancy and Optimal TransportSource quoteOurs │ 0.82 │ 105.64 │ 0.83 │ 74.14 │ 0.83 │ 68.46 │ 0.71 │ 70.27 |
Metricdice (30)psnr (27)ssim (19)dsc (11)inconsistency with radiologist evaluations lower (6)iou (5)
Regimefine-tuned (9)unsupervised (8)unsupervised-domain-adaptation (6)semi-supervised (5)weakly-supervised (4)few-shot (4)
Showing 17 of 17 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MRIComp4Flow Wavelet Flow Matching (WFM), trained on JPEG2000-compressed data at 20:1 proposed | Mean PSNR | 27.3 dB | split: val · modalities=mean across T1n, T1c, T2, T2f · compression=JPEG2000 20:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL4: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (\DeltaPSNR <1\,dB, \DeltaSSIM <0.02; paired TOST p=[[p]]): mean PSNR is 27.3\,dB vs.\ 27.0\,dB and mean SSIM is 0.95 vs.\ 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The code is available at \hyperlink{https://github.com/lisafis/MRIComp4Flow}{https://github.com/lisafis/MRIComp4Flow}. |
| 2026 | MRIComp4Flow WFM trained on JPEG2000-compressed data at 200:1 proposed | PSNR | 24.65 dB | split: val · modality=T1n · compression=JPEG2000 200:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL125: 200 │ 23.25 │ 24.65 │ 23.07 │ 22.63 │ 0.879 │ 0.968 │ 0.937 │ 0.902 |
| 2026 | MRIComp4Flow WFM trained on JPEG2000-compressed data at 400:1 proposed | PSNR | 20.94 dB | split: val · modality=T1n · compression=JPEG2000 400:1 | MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative ModelsSource quoteL126: 400 │ 19.30 │ 20.94 │ 21.29 │ 17.18 │ 0.852 │ 0.829 │ 0.814 │ 0.750 |
| 2025 | UniFS proposed | PSNR improvement over FSMNet | 1.06dB | acceleration=4× · undersampling-patterns=3 | UniFS: Unified Multi-Contrast MRI Reconstruction via Frequency-Spatial FusionSource quoteL176: As shown in Table \ref{tab1}, UniFS consistently outperforms all competing methods in terms of image reconstruction quality. Compared with the current leading method FSMNet \cite{FSMNet}, which also incorporates frequency feature fusion, UniFS achieves significant PSNR improvements of 1.06dB and 2.00dB under 4× acceleration on the BraTs and HCP datasets. These results highlight the effectiveness of the enhanced frequency fusion design within the CMF module. Furthermore, Fig. \ref{fig2} shows reconstructed images and corresponding error maps from different methods. The zoomed-in views reveal that UniFS achieves more accurate texture recovery, while the noticeably smaller error maps further confirm its superior reconstruction fidelity. |
| 2025 | FgC2F-UDiff (Our method) proposed | PSNR | 26.34 dB | synthesis=many-to-one · target-modality=T1ce · input-modalities=T1,T2 | FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI SynthesisSource quoteL312: \multirow{2}{*}{Our method} │ 26.34 │ 0.894 │ 17.45 │ 20.85 │ 27.19 │ 0.937 │ 16.14 │ 18.74 |
| 2024 | HF-GAN proposed | PSNR | 30.27 | aggregation=average across missing-sequence scenarios · architecture=2D slice-based | Principled Feature Disentanglement for High-Fidelity Unified Brain MRI SynthesisSource quoteL301: As detailed in~\autoref{table:quan_brats}, HF-GAN achieves the highest overall average PSNR of 30.27 and SSIM of 0.9393. This represents a notable improvement over the next-best performing methods, the 3D Hyper-GAE (PSNR 29.54, SSIM 0.9361) and our extended baseline TransMI (PSNR 29.45, SSIM 0.9305). This superior performance is a direct result of our hybrid-fusion architecture, which is constructed to extract and integrate the crucial complementary information that defines tumor boundaries and internal structures. This information is often challenging for single-pathway encoders to synthesize accurately. |
| 2024 | MRNet proposed | PSNR | 31.2852 | split: test · plane=axial · direction=FLAIR-to-T2 | MRNet: Multifaceted Resilient Networks for Medical Image-to-Image TranslationSource quoteL269: OURS │ 31.2852 │ 0.9411 │ \checkmark |
| 2024 | X-Diffusion (1-slice input) proposed | Test 3D PSNR | 23.10 | split: test · sequence=FLAIR T2 · input-slices=1 | X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion ModelsSource quoteL131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01 |
| 2023 | McASSR (Ours; rectangle window 4×16/16×4) proposed | PSNR | 30.68 dB | split: test · scale=8x out-of-scale · target-modality=T2 · reference-modality=T1 | Rethinking Multi-Contrast MRI Super-Resolution: Rectangle-Window Cross-Attention Transformer and Arbitrary-Scale UpsamplingSource quoteL576: 30.68 |
| 2022 | TransCSCN proposed | PSNR (dB) | 39.12 dB | split: test · modality-direction=T1w-to-FLAIR | Generalized Brain Image Synthesis with Transferable Convolutional Sparse Coding NetworksSource quoteL439: 39.12 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 41.49 | split: test · orientation=axial · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 37.36 | split: test · orientation=coronal · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2022 | DiffusionMBIR proposed | PSNR ↑ | 37.18 | split: test · orientation=sagittal · acceleration=2× · training-data=fastMRI 2019 knee | Solving 3D Inverse Problems Using Pre-Trained 2D Diffusion ModelsSource quoteL272: DiffusionMBIR~\textcolor{trolleygrey}{(ours)} │ 41.49 │ 0.974 │ 37.36 │ 0.942 │ 37.18 │ 0.953 |
| 2020 | Meta-SRGAN proposed | PSNR | 18.72 dB | scale=x2 | Arbitrary Scale Super-Resolution for Brain MRI ImagesSource quoteL111: mean │ 17.98 │ 0.6091 │ 18.93 │ 0.6885 │ 18.42 │ 0.7295 │ 18.72 │ 0.7279 |
| 2020 | ReMIC proposed | PSNR (↑) | 28.5508 | split: test · target=T1 | Multi-Domain Image Completion for Random Missing Input DataSource quoteL357: {ReMIC} │ {0.0187 / {0.2008} / {28.5508} / {0.9618}} │ {0.0153 / {0.2375} / {29.1628} / {0.9521}} |
| 2019 | CPRN proposed | PSNR | 36.500 | scale=×2 · subset=slices 60, 80, 100, 120, 140 · degradation=bicubic downsampling | Coupled-Projection Residual Network for MRI Super-ResolutionSource quoteL156: CPRN │ ×2 │ \textcolor[rgb]{1.00,0.00,0.00}{36.500/0.9911} │ \textcolor[rgb]{1.00,0.00,0.00}{28.324/0.9268} │ \textcolor[rgb]{1.00,0.00,0.00}{26.114/0.9515} SRCNN │ ×4 │ 26.780/0.7034 │ 20.103/0.7831 │ 19.998/0.8142 |
| 2019 | CPRN proposed | PSNR | 29.330 | scale=×4 · subset=slices 60, 80, 100, 120, 140 · degradation=bicubic downsampling | Coupled-Projection Residual Network for MRI Super-ResolutionSource quoteL160: CPRN │ ×4 │ \textcolor[rgb]{1.00,0.00,0.00}{29.330/0.9439} │ \textcolor[rgb]{1.00,0.00,0.00}{22.331/0.8142} │ \textcolor[rgb]{1.00,0.00,0.00}{21.981/0.8687} |