BraTS

93 papers · 227 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.91.0201820222025SynNet (Weighted L₂ loss): 0.69 (2018)SynNet (Joint Loss): 0.7 (2018)SynNet (Weighted L₂ loss): 0.77 (2018)SynNet (Joint Loss): 0.86 (2018)ReMIC: 0.9618 (2021)TransCSCN: 0.943 (2022)SyMOT-Flow: 0.83 (2023)MRNet: 0.9411 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 3 of 3 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Transfer-Aware proposedDice55.1%fine-tuned · modality=Brain T1Knowledge Transfer Scaling Laws for 3D Medical Imaging
Source quote
L468: The same trend holds for dense prediction. On AMOS, Transfer-Aware achieves 83.1 Dice on abdominal CT and 69.4 Dice on abdominal MRI, outperforming Data-Proportional by 1.5 and 0.6 points, respectively. The gains are larger on brain and head-and-neck tasks. On BraTS, Transfer-Aware improves over Data-Proportional from 50.4 to 55.1 Dice on Brain T1 and from 61.4 to 65.4 Dice on Brain T2. On head-and-neck CT segmentation, Transfer-Aware improves HECKTOR from 67.8 to 71.1 Dice and BHSD from 57.2 to 61.2 Dice. Across all six segmentation tasks, Transfer-Aware yields the best performance among the compared pretraining strategies.
2026Data-Proportional baselineDice50.4%fine-tuned · modality=Brain T1Knowledge Transfer Scaling Laws for 3D Medical Imaging
Source quote
L468: The same trend holds for dense prediction. On AMOS, Transfer-Aware achieves 83.1 Dice on abdominal CT and 69.4 Dice on abdominal MRI, outperforming Data-Proportional by 1.5 and 0.6 points, respectively. The gains are larger on brain and head-and-neck tasks. On BraTS, Transfer-Aware improves over Data-Proportional from 50.4 to 55.1 Dice on Brain T1 and from 61.4 to 65.4 Dice on Brain T2. On head-and-neck CT segmentation, Transfer-Aware improves HECKTOR from 67.8 to 71.1 Dice and BHSD from 57.2 to 61.2 Dice. Across all six segmentation tasks, Transfer-Aware yields the best performance among the compared pretraining strategies.
2025Causal-SAM-LLM proposedDice75.7%fine-tuned · evaluation=single-source-domain-generalization · aggregation=three random seeds · training_dataset=BTCV CTCausal-SAM-LLM: Large Language Models as Causal Reasoners for Robust Medical Segmentation
Source quote
L173: Causal-SAM-LLM │ 52.8 │ 83.5 │ 23.4 │ \bfseries 79.5 │ \bfseries 18.9 │ \bfseries 75.7 │ \bfseries 17.6