Research Overview

Matthew Tivnan focuses on medical image reconstruction, physics-informed machine learning, and the application of generative priors to inverse problems. His trajectory spans from early hardware instrumentation to advanced computational imaging techniques that integrate physical measurement models with diffusion processes. Currently, his work addresses the reliability, safety, and evaluation of generative models in clinical settings, particularly for computed tomography.

Research Trajectory

The trajectory begins with physical instrumentation and hardware-software co-design. Early research demonstrated the feasibility of using low-cost minicomputers for optical spectroscopy, detailed in High Frequency Sampling of TTL Pulses on a Raspberry Pi for Diffuse Correlation Spectroscopy Applications. This interest in measurement systems evolved into complex medical imaging hardware, culminating in the development of spatial-spectral filters for spectral CT. The work Design Optimization of Spatial-Spectral Filters for Cone-Beam CT Material Decomposition introduced a novel device to modulate x-ray beam spectral shapes alongside a direct model-based material decomposition method, utilizing Fisher-information-based metrics to optimize the filter design.

By 2023, the focus expanded significantly into deep learning and generative models for image restoration, particularly addressing the bias-variance trade-offs inherent in traditional and iterative reconstruction. Tunable neural networks for CT image formation proposed a novel loss function to give neural networks the kind of tunable control over output image properties typically found in classical filtered back-projection. Recognizing the statistical risks of applying deep learning to high-stakes medical imaging, subsequent research introduced conformal risk control procedures. How to Trust Your Diffusion Model: A Convex Optimization Approach to Conformal Risk Control framed risk control as a multidimensional convex optimization problem to provide mathematically guaranteed uncertainty intervals for diffusion model outputs. This period also marked a deep engagement with the research direction of Physics-Informed Generative Priors for Imaging Inverse Problems. Diffusion Posterior Sampling for Nonlinear CT Reconstruction introduced a plug-and-play method combining unsupervised diffusion models with nonlinear physical measurement models, advancing the broader area of Preserving Structural Fidelity in Generative Medical Imaging by achieving high-fidelity results in low-dose and sparse-view scenarios without retraining for specific scanner geometries.

In 2024, the methodological toolkit expanded to include Schrödinger Bridges, aiming to improve inference speed and restoration quality. Measurement Embedded Schrödinger Bridge for Inverse Problems directly bridged the gap between corrupted observations and clean image distributions by mathematically embedding measurement constraints into the generative process. Concurrently, the critical issue of generative artifacts in medical imaging was formalized in Hallucination Index: An Image Quality Metric for Generative Reconstruction Models, providing a quantitative basis for evaluating the safety of these advanced reconstruction techniques.

The integration of physical systems into generative models matured further in 2025. Work in the area of Diffusion Priors for Non-linear Inverse Problems led to System-Embedded Diffusion Bridge Models, which baked known measurement system geometries directly into the coefficients of a matrix-valued stochastic differential equation, ensuring robustness even when deployment systems differed from training environments. Similar principles were applied to incomplete data challenges in Projection Embedded Diffusion Bridge for CT Reconstruction from Incomplete Data. To accelerate these processes, Implicit Image-to-Image Schrödinger Bridge for image restoration reformulated the generative process to be non-Markovian, significantly reducing computational steps.

The evaluation and refinement of these models for specific clinical tasks became increasingly rigorous. Fourier Diffusion Models: A Method to Control MTF and NPS in Score-Based Stochastic Image Generation contributed to the area of Informed Priors for Efficient Diffusion Trajectories by incorporating linear shift-invariant systems to explicitly control the Modulation Transfer Function and Noise Power Spectrum. The analysis of artifacts continued with Hallucination Analysis of Score-Based Diffusion Models for CT Denoising Through Spatial Frequency Decomposition and practical applications like Portable head CT motion artifact correction via diffusion-based generative model. The clinical impact of these methods was critically assessed in Task based evaluation of sparse view CT reconstruction techniques for intracranial hemorrhage diagnosis using an AI observer model, which identified a "reconstruction paradox" where traditional iterative methods scored higher on standard image quality metrics but performed worse on actual diagnostic tasks compared to deep learning approaches.

Beyond standard CT reconstruction, generative and foundational models were adapted for diverse medical applications. Prediction of Frozen Region Growth in Kidney Cryoablation Intervention Using a 3D Flow-Matching Model utilized continuous deformation fields learned from intraoperative scans to predict tissue freezing. OWT: A Foundational Organ-Wise Tokenization Framework for Medical Imaging introduced a modular approach to medical AI, explicitly tokenizing images by organ to improve fine-grained clinical tasks. Additionally, Rethinking Visual Counterfactual Explanations Through Region Constraint explored interpretability in visual models.

Most recently, the focus on reliability has extended to auditing state-of-the-art clinical AI systems. Auditing Sybil: Explaining Deep Lung Cancer Risk Prediction Through Generative Interventional Attributions introduced a framework using 3D diffusion models to realistically manipulate lung nodules in CT scans, revealing critical vulnerabilities and biases in existing lung cancer risk prediction models.

Current Directions

Recent work investigates the safety, interpretability, and physical grounding of generative AI in clinical environments. A primary focus is the rigorous auditing of medical AI systems, utilizing generative interventional techniques to uncover hidden biases—such as spatial blind spots or sensitivity to medical artifacts—before deployment. Concurrently, ongoing research addresses the persistent challenge of hallucinations in diffusion models and Schrödinger Bridges. By embedding physical measurement constraints directly into the generative process and developing specialized metrics for spatial frequency decomposition, these efforts aim to guarantee that AI-reconstructed medical images remain faithful to the underlying patient anatomy and are robust across different imaging hardware.