Siyeop yoon
5 previous affiliations
- Massachusetts General Hospital2023–2025
- Postdoc · 2023–2025
- Harvard Medical School2021–2023
- Postdoc · 2021–2023
- Beth Israel Deaconess Medical Center2021–2023
- Postdoc · 2021–2023
- PhD student · 2014–2021
- PhD student · 2014–2021
Research Overview
Siyeop Yoon focuses on the development and application of generative modeling frameworks for medical imaging, with a particular emphasis on solving complex inverse problems through diffusion-based architectures and Schrödinger bridges. Yoon’s work addresses critical challenges in clinical diagnostics, including image denoising, super-resolution, and the synthesis of three-dimensional volumetric data from sparse two-dimensional inputs. By integrating Physics-Informed Generative Priors for Imaging Inverse Problems, Yoon’s research seeks to enhance the fidelity and reliability of medical reconstructions while reducing the computational overhead typically associated with iterative generative processes.
Research Trajectory
Yoon’s research trajectory is defined by a rapid progression from standard score-based generative models toward more sophisticated, accelerated, and physics-constrained frameworks. In the early stages of this observed period (2024), the focus was primarily on the application of volumetric conditional score-based models to specific modalities such as PET/MR and CT. These initial efforts established a foundation in Uncertainty Quantification for Imaging Inverse Problems, where the goal was to reconstruct high-quality medical volumes from noisy or undersampled data.
As the work evolved into 2025, Yoon’s methodological focus shifted toward the optimization of the generative process itself. Recognizing the limitations of standard diffusion models—which often require extensive iterations to refine a sample from pure noise—Yoon began exploring Informed Priors for Efficient Diffusion Trajectories. This led to significant contributions in the area of Schrödinger bridges, which provide a more direct mathematical path for image-to-image translation, thereby bypassing the "blank slate" requirement of traditional diffusion and offering substantial gains in inference speed.
Concurrently, Yoon’s work has expanded to address the socio-technical dimensions of clinical AI. This is evidenced by participation in research regarding Equitable Clinical AI through Demographic Debiasing, which applies optimal control theory to ensure that segmentation and reconstruction models perform consistently across diverse patient populations. This transition reflects a move from purely algorithmic performance toward a broader consideration of model robustness, fairness, and clinical utility.
Methodological Contributions
A central theme in Yoon’s work is the tension between perceptual quality and mathematical accuracy. In generative image restoration, models often face a trade-off where optimizing for pixel-wise metrics results in blurry outputs, while optimizing for realism can introduce artifacts. Yoon has addressed this by Balancing Realism and Accuracy in Generative Image Restoration, developing metrics and frameworks that quantify the reliability of generated content. This includes the development of the "Hallucination Index," a metric designed to detect when a generative model introduces plausible but anatomically incorrect features into a medical reconstruction.
Furthermore, Yoon has contributed to the advancement of The Perceptual Misalignment of Image Quality Metrics. By moving beyond traditional metrics like Peak Signal-to-Noise Ratio (PSNR), the research explores how generative models can produce images that are not only mathematically close to the ground truth but also visually and diagnostically useful for clinicians. This involves the use of conditional score-based models that incorporate structural priors, ensuring that the synthesized images maintain the anatomical integrity required for medical decision-making.
Representative Work
The following papers characterize Yoon’s contributions to the fields of generative modeling and medical imaging, illustrating the evolution from volumetric reconstruction to accelerated bridge models and fairness-aware systems.
In Volumetric Conditional Score-Based Residual Diffusion Model for PET/MR Denoising, Yoon (as first author) addresses the challenge of noise in simultaneous PET/MR imaging. The work utilizes a score-based residual diffusion framework that operates on volumetric data, allowing the model to leverage three-dimensional spatial correlations to improve denoising performance. This approach demonstrates the utility of conditional diffusion in handling the high-dimensional nature of medical volumes, providing a more robust alternative to traditional 2D denoising methods.
The problem of dimensionality is further explored in High-Resolution 3d Ct Synthesis From Bidirectional X-Ray Images Using 3d Diffusion Model. As the lead author, Yoon proposes a method for reconstructing 3D CT volumes from limited 2D X-ray projections. This is a classic ill-posed inverse problem where the goal is to recover lost depth and structural information. The use of a 3D diffusion model allows for the synthesis of high-resolution volumes that are consistent with the input bidirectional views, showcasing the generative model's ability to act as a powerful structural prior.
Yoon’s work on algorithmic efficiency is exemplified by the Implicit Image-to-Image Schrodinger Bridge for CT Super-Resolution and Denoising. Serving as the second author, Yoon contributed to the development of the $I^3SB$ framework, which transforms the generative process into a non-Markovian chain. By re-incorporating the original corrupted image at each step of the denoising process, the model achieves high-quality restoration with significantly fewer computational steps than previous iterations. This work is pivotal for clinical applications where real-time or near-real-time processing is essential.
To address the risks associated with generative models in medicine, Yoon co-authored Hallucination Index: An Image Quality Metric for Generative Reconstruction Models. This research introduces a formal metric to evaluate the tendency of generative models to "hallucinate" details that do not exist in the source data. By providing a quantitative measure of these errors, the work contributes to the safer deployment of generative AI in sensitive diagnostic environments, where the cost of a false positive or an artificial anatomical feature is high.
Yoon also participated in the development of System-Embedded Diffusion Bridge Models. This research integrates the physical parameters of the imaging system—such as the geometry of a CT scanner—directly into the stochastic differential equations (SDEs) that govern the diffusion process. This "system-embedded" approach ensures that the generative model remains grounded in the physics of the acquisition process, improving the model's robustness to variations in hardware or scanning protocols.
Finally, Yoon’s involvement in Distribution-aware Fairness Learning in Medical Image Segmentation From A Control-Theoretic Perspective demonstrates an expansion into the ethics of clinical AI. This work utilizes a Distribution-aware Mixture of Experts (dMoE) framework, reinterpreting neural network layers through optimal control theory to adaptively handle diverse patient demographics. This participation highlights Yoon’s role in collaborative efforts to mitigate algorithmic bias and ensure that high-performance medical imaging tools are equitable across different population groups.
Profile updated
Loading new papers…
Other researchers whose papers cluster into the same research directions — a proxy for overlapping technical interests and shared intellectual neighborhoods.
See something wrong? Report a mistake