Abstract
This study aims to develop a standardized algorithm for gastroesophageal image acquisition and diagnostic assessment using real-time MRI. Patients with GERD symptoms undergoing real-time MRI of the esophagus and esophagogastric junction between 2015 and 2018 were included. A 10 ml bolus of pineapple juice served as an oral contrast agent. Patients performed Valsalva maneuver to provoke reflux and hiatal hernia. Systematic MRI assessment included visual presence of achalasia, fundoplication failure in patients with previous surgical fundoplication, gastroesophageal reflux, and hiatal hernia. A total of 184 patients (n = 92 female [50%], mean age 52.7 ± 15.8 years) completed MRI studies without adverse events at a mean examination time of 15 min. Gastroesophageal reflux was evident in n = 117 (63.6%), hiatal hernia in n = 95 (52.5%), and achalasia in 4 patients (2.2%). Hiatal hernia was observed more frequently in patients with reflux at rest (n = 67 vs. n = 6, p < 0.01) and during Valsalva maneuver (n = 87 vs. n = 8, p < 0.01). Real-time MRI visualized a morphologic correlate for recurring GERD symptoms in 20/22 patients (90%) after fundoplication procedure. In a large-scale single-center cohort of patients with GERD symptoms undergoing real-time MRI, visual correlates for clinical symptoms were evident in most cases. The proposed assessment algorithm could aid in wider-spread utilization of real-time MRI and provides a comprehensive approach to this novel imaging modality.
Introduction
Gastroesophageal reflux disease (GERD) is a highly prevalent condition, yet identifying its underlying structural or functional causes—such as hiatal hernias or motility disorders—can be challenging. Traditional diagnostic methods like barium esophagrams involve ionizing radiation, while 24-hour pH-metry is invasive and uncomfortable for patients.
Real-time MRI (RT-MRI) has emerged as a powerful, radiation-free alternative capable of high-speed imaging (up to 25 frames per second). However, the lack of a standardized protocol has limited its clinical adoption. This paper introduces a reproducible, 15-minute algorithm for both acquiring and interpreting RT-MRI images of the esophagus and esophagogastric junction (EGJ).
Methods
The standardized approach developed by the researchers focuses on three main pillars:
- Specialized Imaging Sequence: The protocol utilizes undersampled radial FLASH (Fast Low Angle Shot) sequences combined with nonlinear inverse reconstruction. This achieves a temporal resolution of 40 ms per frame, sufficient to capture the rapid mechanics of swallowing.
- Natural Contrast: Instead of synthetic agents, patients drink a 10 ml bolus of pineapple juice. The high manganese content in the juice acts as a natural T1 contrast agent, making the liquid bolus appear bright on the MRI.
- Provocation Maneuvers: To identify intermittent issues, patients perform the Valsalva maneuver (straining) during the scan. This increases intra-abdominal pressure, helping to provoke reflux or reveal "sliding" hiatal hernias that might not be visible at rest.
Key Results and Insights
The study, conducted on a cohort of 184 patients with chronic GERD symptoms, demonstrated high efficiency and diagnostic yield:
- Efficiency: The median scan time was only 15 minutes, making it viable for clinical workflows.
- Diagnostic Yield: Gastroesophageal reflux was visualized in 63.6% of patients, and hiatal hernias were found in 52.5%.
- Post-Surgical Utility: RT-MRI was particularly effective at identifying why anti-reflux surgeries fail, finding a morphologic cause in 90% of patients with recurring symptoms after fundoplication.
Using a common grocery item like pineapple juice as a contrast agent is a practical "bio-hack" that avoids regulatory hurdles and costs while ensuring patient safety. Furthermore, the ability of RT-MRI to capture the dynamics of the EGJ provides a more complete diagnostic picture than static imaging.
Limitations and Future Directions
A primary limitation of the study was the lack of a healthy control group to establish a "normal" baseline for reflux. Additionally, the researchers did not use standardized questionnaires to correlate symptom severity with MRI findings. Future work aims to create a standardized, annotated DICOM dataset to serve as a training resource for other institutions looking to implement this real-time imaging protocol.