Abstract
This study explores the feasibility of identifying users through high-frequency eye-movement data captured by Laser Interferometry (LFI) sensors. By leveraging a comprehensive set of time- and frequency-domain features from raw velocity and distance signals, we demonstrate that unique biometric signatures exist in eye kinematics. Our results show that lightweight classifiers can achieve up to 96.74% identification accuracy, presenting both a novel biometric modality and a significant privacy consideration for future wearable technology.
Introduction
Traditional eye-tracking systems in virtual reality (VR) and augmented reality (AR) typically rely on video-oculography (VOG). While effective, VOG systems are computationally intensive, power-hungry, and raise privacy concerns due to the continuous capture of eye images. Laser Interferometry (LFI) offers a more efficient, privacy-preserving alternative by measuring eye surface velocity and sensor-to-eye distance at high frequencies (up to 1000 Hz) without capturing images. However, LFI lacks direct "gaze" information. This research investigates whether raw LFI signals contain sufficient idiosyncratic information to identify individuals based solely on their unique eye movement patterns.
Methodology
The proposed approach focuses on a feature-engineering pipeline designed for resource-constrained wearable devices, avoiding the high computational costs of deep learning.
Signal Processing and Feature Extraction
Raw velocity and distance data are processed to derive secondary kinematics, including acceleration, jerk, and absolute velocity magnitude. From these signals, a diverse set of "handcrafted" features is extracted over 5-second windows. These features are categorized into time-domain and frequency-domain metrics to capture both the temporal dynamics and the spectral characteristics of eye movements.
Classification
The study evaluated several models, identifying LightGBM and Linear Support Vector Machines (SVM) as the most effective for balancing high accuracy with the low latency requirements of wearable hardware.
Experimental Setup
The methodology was validated using a dataset of 10 participants with 12 hours of 1000 Hz LFI recordings. The data encompassed seven distinct activities: reading, watching video, typing, talking, walking, cycling, and solving problems. This variety ensures the robustness of the biometric signature across different cognitive and physical states.
Results and Discussion
The experimental results highlight several key findings regarding the performance and requirements of LFI-based biometrics.
Performance Benchmarks
In a multi-class identification task, the system achieved a baseline accuracy of 93.14% with an Equal Error Rate (EER) of 2.52% using 5-second windows. Performance was further enhanced through "majority voting" across multiple consecutive windows. Specifically, aggregating predictions from five 2-second windows increased accuracy to 96.74% and reduced the EER to 1.01%.
Hardware Requirements and Activity Influence
A critical observation was the relationship between sampling rate and accuracy. While 1000 Hz provides the best results, performance remains stable down to 250 Hz. Below this threshold, accuracy drops significantly (e.g., 72.97% at 100 Hz), suggesting a minimum hardware requirement for reliable biometric identification. Additionally, structured tasks like reading yielded the highest individual accuracies (up to 96.03%), likely because the rhythmic nature of the task emphasizes personal movement quirks.
Conclusion and Future Work
This research demonstrates that LFI-based eye movement data is a viable biometric. However, several challenges remain. The current study is limited by a small sample size (N=10) and lacks longitudinal data to assess "template aging"—how these signatures change over time. Furthermore, while LFI avoids image capture, the ability to identify users from raw signals introduces a "privacy paradox." Future work should focus on developing privacy-preserving techniques that allow for secure authentication without enabling unauthorized tracking.